• Title/Summary/Keyword: indoor activity

Search Result 253, Processing Time 0.024 seconds

가청화를 이용한 실내수영장의 음향 성능평가에 관한 연구 (A Study on Valuation of Acoustic Performance for Indoor Swimming Pool utilizing Auralization)

  • 정철운;국정훈;윤재현;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.720-724
    • /
    • 2007
  • Recently, in accordance with increase of the desire for Sports for All(Life Sports), the swimming pools in many areas are under construction. However, since they used many of the reflexible finish-materials on account of the characteristics of hydrophilic space, most of the Indoor Swimming Pools are generating the excessive reverberation. Such reverberation is bringing about the problem that obstructs the oral communication between the coach and the player, and the Clearness of Sound, besides the sport activity. On this viewpoint, on the object of the actually built indoor swimming pool, after the conduct of an optimized acoustics design by the remodeling through a computer simulation, and by carrying out the Psycho-Acoustics Experiment utilizing of Auralization Technique which is able to experience Virtual Sound Field at the stage of designing, then this thesis has attempted to appraise on the acoustic condition after the completion of construction. It is considered that such result of the study could be utilized as the useful data that enables to improve the curtailment effect of construction cost as well as the acoustic capability, by means of the presupposition control on the acoustic problem from the stage of design, for the occasion when the similar indoor swimming pool is planning to build, henceforth.

  • PDF

Changes of Behavioral and Physiological Responses Caused by Color Temperature

  • Lee, Young-Chang;Min, Yoon-Ki;Min, Byung-Chan;Kim, Boseong
    • 감성과학
    • /
    • 제18권2호
    • /
    • pp.37-44
    • /
    • 2015
  • LED lighting has an advantage of adjusting color temperature. This change of color temperature may derive change in behavioral and physiological responses of the visual perception for indoor environments. This research examined the changes of behavioral and physiological responses caused by the color temperature. The environment was configured that the indoor temperature was 20 degrees centigrade or less as the perceived uncomfortable environment in winter. Then, the comfortable sensation vote (CSV) and the results of 3-back working memory test were measured as behavioral responses. In addition, the Electrodermal Activity (EDA) and Electrocardiogram (ECG) were measured as the responses of autonomics nervous system (ANS) in the three conditions of color temperature (red: 3862K, white: 5052K, blue: 11,460K). As a result, behavioral responses were not significant by the condition of color temperature, but the tendency of occupants' physiological relaxation appeared in the blue color temperature condition compared with the white color temperature condition. Although the color temperature of LED lighting might be a small factor in terms of the characteristics of indoor environment, it suggests that the color temperature could have an impact on the physiological changes in the parasympathetic nervous system.

아산지역에 있어서의 $NO_{2}$ 개인 피폭량에 미치는 각종 생활행동 패턴의 영향 (Effects of Human Activity Patterns on Personal Exposure Levels of Nitrogen Dioxide in A-San Area)

  • 손부순;김대선;정문식
    • 환경위생공학
    • /
    • 제11권3호
    • /
    • pp.47-52
    • /
    • 1996
  • Personal exposure levels of $NO_{2}$ for office workers and housewives Living in A-San and neighboring prefectures were measured in two seasons with $NO_{2}$ filter badge. $NO_{2}$ concentrations in indoor and outdoor air in their offices and houses were also measured in the same periods. Personal exposure levels in winter ranged from 13 to 132 ppb and its distribution pattern was remarkably different from the other seasons (15.2-17.9 ppb). This fact suggests that use of heating apparatus affects largely $NO_{2}$ indoor air pollution in winter seasons. Actually, $NO_{2}$ exposure levels of subjects used Kerosene heater (43.6ppb) and gas heater (33.4ppb) were higher than those of subjects unused heating apparatus (18.0ppb). Personal exposure levels of $NO_{2}$ for man and woman Living in the same houses were correlated well each other. The time spent indoors for office workers and housewives were both longer than 22 hour a day. Home staying time was about 60% of total indoor staying time for office workers and 90% or more for housewives. Personal exposure levels were significantly related to indoor exposure levels at home all seasons. Furthermore, personal exposure levels could be estimated from $NO_{2}$ concentrations and staying times in various Living environment.

  • PDF

유비쿼터스 헬스케어를 위한 저비용, 수동형 실내 위치추적 시스템 (Passive and Cost Effective People Indoor Location Tracking System for Ubiquitous Healthcare)

  • 정완영;;임효택
    • 한국정보통신학회논문지
    • /
    • 제10권6호
    • /
    • pp.1119-1123
    • /
    • 2006
  • 유비 쿼터스 헬스케어용 초음파와 RF 기술을 이용한 무선센서네트워크 기반의 실내 위치 추적 시스템을 구현하고 테스트하였다. 개발된 실내 위치인식 시스템은 헬스케어를 위한 홈네트워크 장치의 하나로서 노인이나 만성질환자의 이동성과 활동성을 측정하는데 주안점을 두어 개발되었다. 천장에 설치된 비컨들은 RF신호를 사용하여 위치 정보를 listener에게 전송하게 되며, listener는 삼각측량법을 사용하여 3개의 비컨들로부터 얻어진 좌표 값을 계산하여 실내에서의 사람이나 물체의 위치 측정뿐만 아니라 환자의 활동성측정이 가능하도록 개발되었다. 본 연구에서는 위치에 대한 보안이 가능하도록 수동형식의 위치인식시스템을 구현하고 비용절감을 위해 센서노드 사이의 연결이 무선으로 되도록 ad-hoc 알고리즘을 사용하였다.

한방병원 실내계획에 관한 연구 (A Study on the indoor Plan of chinese Medicine Hospital)

  • 김정진;진용녀
    • 한국실내디자인학회논문집
    • /
    • 제18호
    • /
    • pp.74-80
    • /
    • 1999
  • Chinese medicine hospital enables the users to expect more efficient cure result in the psychological stability and the comfortable indoor environment by supplying the functional and aesthetic cure space with the medical action of good quality Medical activity is to treat the human life. Thus, hospital must be more human-centered-place than other space. Thus study is establishment of space to be able to lead more rational and active participation than the conservative and passive image of the department of diagnosis and treatment for outpatients is desirable. This study is the indoor schedule to suggest the direction about the department of diagnosis and treatment for outpatients of Chinese medicine hospital of native image with more comfortable and positive approach on the basis of above points at issues as the schedule to fulfill the performance of medical function and the emotional and psychological satisfaction of users as the human being-centered-medical institution on the subject of the department of diagnosis and treatment for outpatients in Chinese medicine hospital. And, this researcher progressed as follows by being premised on this 1. Description of Goai, Range and Method of Study and Suggestion of Study Direction 2. Concept introduction as the Basic Approach of Theory which is necessary for Study 3. The Problems were recognized by grasping the present condition in Korea through the questionaines 4. establishment of Concept and direction which are necessary for planning the indoor of the department of Diagnosis and Treatment for Chinese Medicine Hospital 5. Progression of Design Plan attendant upon Concept 6. Analysis of the Conents attendant upon this, and Conclusiov.

  • PDF

아파트단지 경로당의 겨울철 실내환경 실태 (The Actual State of the Indoor Environment in the Elderly Hall at Apartment Complexes during Winter)

  • 최윤정;양현주;양은석;김선희;전은선
    • 한국생활과학회지
    • /
    • 제20권1호
    • /
    • pp.225-241
    • /
    • 2011
  • The purposes of this study were to determine the actual state of the indoor environment, and to analyze the relationship between the architectural or living factors and indoor physical elements in the elderly hall at apartment complexes during winter. The field surveys consisted of measurements of the physical elements, observations of living factors, and interviews with users. The field surveys were carried out at 5 halls in February 2009. The measured elements were air temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, and illumination. The results showed that the averages of indoor temperature for the hall was between $22.7{\sim}25.1^{\circ}C$, relative humidity was 22.0~48.2%, $CO_2$ level was 892.4~2066.7ppm, CO level were 0~0.4ppm, PM10 level were $22.3{\sim}31.4{\mu}g/m^3$, HCHO level was 0.00~0.24ppm, and illumination level was 94~391.6lux. TVOC level was detected at 0.00~0.54ppm in only one hall. The average clothing amount of the users was 1.18clo and activity was 0.7~1.6met. It was evaluated to be a comfortable state at indoor temperature, CO level, PM10 level, and TVOC level, but an uncomfortable state at relative humidity, $CO_2$ level, HCHO level, and illumination level. The main reason seemed to be lack of ventilation.

Exposure Assessments for Children in Homes and in Daycare Centers to NO2, PMs and Black Carbon

  • Lee, Jae Young;Kim, Changhyeok;Kim, Jongbum;Ryu, Sung Hee;Bae, Gwi-Nam
    • Asian Journal of Atmospheric Environment
    • /
    • 제12권3호
    • /
    • pp.204-214
    • /
    • 2018
  • Indoor air quality was investigated in homes and daycares located in areas with heavy traffic in Seoul, South Korea from November 2013 to January 2014. Indoor and outdoor air quality measurements were collected for 48 hours in four children's homes and daycare centers. The I/O ratio (Indoor to outdoor ratio) for each major air pollutant ($NO_2$, black carbon, $PM_{10}$, and $PM_{2.5}$) was calculated, and $NO_2$ and $PM_{10}$ concentration profiles were analyzed based on indoor activity diaries recorded during the 48 hours. Most I/O ratios for $NO_2$, black carbon, $PM_{10}$, and $PM_{2.5}$ at daycare centers were less than one. At homes, I/O ratios for black carbon, $PM_{10}$, and $PM_{2.5}$ were less than one; however, most I/O ratios for $NO_2$ were greater than one due to the usage of gas stoves. The children's exposure to indoor air pollutants was calculated using a time-weighted average exposure method, and the daily intake level for each pollutant was determined.

유아(幼兒)의 특성을 고려한 기능적 실내복 디자인 개발 - 만 3-6세 남아를 중심으로 - (Development of Functional Indoor Apparel Considering Toddlers' Behavioral Characteristics - Focus on 3-6-Year Old Boys -)

  • 남영란;최혜선
    • 복식
    • /
    • 제63권1호
    • /
    • pp.81-96
    • /
    • 2013
  • We interviewed and surveyed parents of 3 to 6-year-old boys in order to determine designs for indoor apparel that appealed to toddlers. In addition, on the basis of the behavioral characteristics of such boys, improvements in the development of indoor apparels were suggested. Parents preferred indoor apparels because it could be worn as underwear when the kid is outdoors and as outerwear when indoors. These apparels were popular with toddlers. Therefore, indoor apparel that gives the impression of outerwear while performing the function of underwear was designed. Underwear fabric was used, but outerwear apparel design was partially adopted. In order to improve the activity, fabric that could be stretched in any direction was used for the sleeves and pant legs, while organic fabric with soft texture was used for the trunk part of the apparel. Dark-colored material was used for the chest and elbow parts of the clothes in order to prevent contamination in these parts. In particular, a bib was used to prevent contamination in the chest part. Given that toddlers engage in many activities, the fabric needed to be durable, so this led to thick materials being used for the knee part. As certain parents complained about the short length for tops, we increased the length of the tops by 5cm. In the survey items that investigated overall wearability, ease, and suitability for toddlers' activities, the test apparel obtained a higher score than existing apparel did. This indicates that the overall suitability of the newly designed apparel was improved.

실내 및 실외 공기중 이산화질소의 개인 노출량 측정을 위한 수동식 시료채취기의 성능평가 (Evaluation of Passive Monitor for the Measuring of Personal Exposure to Nitrogen Dioxide in Indoor and Outdoor Air)

  • 양원호;이기영;백도명
    • 한국대기환경학회지
    • /
    • 제16권6호
    • /
    • pp.625-631
    • /
    • 2000
  • Practical devices for measuring personal exposure to nitrogen dioxide(NO$_2$) have been made for epidemiological studies of the health effects of air pollution Standard methods for NO$_2$ measurement such as the chemiluminescent method and Saltzman method are not suitable for personal exposure because they are heavy, large and complicated to operate. In this study, a passive monitor was tested for the measurements of indoor and outdoor NO$_2$ level. Through a comparative analysis of data sets obtained by on-site chemiluminescence system, we assessed the accuracy and precision of NO$_2$ passive monitors. We also examined the possibility of passive monitor in the study of indoor, outdoor and personal NO$_2$ exposure. The accuracy and precision of NO$_2$ passive monitor were analyzed assuming measurements of on-site chemiluminescence system is reference value and using duplicated measure- ments, respectively. From these analysis the NO$_2$ passive monitor was useful for measuring indoor, outdoor and personal exposure. And NO$_2$ level from on-site chemiluminescence systems could not properly represent the personal NO$_2$ exposure as well as indoor and outdoor level of ones house. Personal exposures were correlated more strongly with indoor NO$_2$ concentrations than with outdoor NO$_2$ concentrations. Since activity pattern of each person is different, it was considered that personal daily behavior and life-style might prevent the air pollutant exposure.

  • PDF

시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정 (Estimation of Ventilation Rates in Korean Homes Using Time-activity Patterns and Carbon Dioxide (CO2) Concentration)

  • 박진현;류현수;허정;조만수;양원호
    • 한국환경보건학회지
    • /
    • 제45권1호
    • /
    • pp.1-8
    • /
    • 2019
  • Objectives: The purpose of this study was to estimate the ventilation rate of residential homes in Korea through tracer gas methods using indoor and outdoor concentrations of carbon dioxide ($CO_2$) and $CO_2$ generation rates from breathing. Methods: In this study, we calculated the number of occupants in a home by time through data on the average number of people per household from the Korean National Statistical Office and also measured the amount of $CO_2$ generation by breathing to estimate the indoor $CO_2$ generation rate. To estimate the ventilation rate, several factors such as the $CO_2$ generation rate and average volume of residential house provided by the Korean National Statistical Office, indoor $CO_2$ concentrations measured by sensors, and outdoor $CO_2$ concentrations provided by the Korea Meteorological Administration, were applied to a mass balance model for residential indoor environments. Results: The average number of people were 2.53 per household and Koreans spend 61.0% of their day at home. The $CO_2$ generation rate from breathing was $13.9{\pm}5.3L/h$ during sleep and $15.1{\pm}5.7L/h$ in a sedentary state. Indoor and outdoor $CO_2$ concentrations were 849 ppm and 407 ppm, respectively. The ventilation rate in Korean residential houses calculated by the mass balance model were $42.1m^3/h$ and 0.71 air change per hour. Conclusions: The estimated ventilation rate tended to increase with an increase in the number of occupants. Since sensor devices were used to collect data, sustainable data could be collected to estimate the ventilation rate of Korean residential homes, which enables further studies such as on changes in the ventilation rate by season resulting from the activities of occupants. The results of this study could be used as a basis for exposure and risk assessment modeling.