• 제목/요약/키워드: indoor

검색결과 6,768건 처리시간 0.035초

물질수지를 이용한 학교 실내환경의 포름알데히드(HCHO) 배출량 산정에 의한 실내공기질 개선 평가 (Evaluation of Indoor Air Quality Improvement by Formaldehyde Emission Rate in School Indoor Environment Using Mass Balance)

  • 양원호;손부순;김대원;김영희;변재철;정순원
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.160-165
    • /
    • 2005
  • Schools have significant and serious indoor environmental health problem, of which indoor air quality (IAQ) in school building may affect the health of the students and indirectly affect learning performance. Schools are of special concern when regarding indoor exposure to air pollutants, because students are particularly sensitive to pollutants and spend a significant amount of time in that environment. Therefore researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide(TiO2) coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde emission rate in school indoor environments by far-Infrared ray coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor air quality.

실내공기질 개선 시스템의 서버 구성 방식에 따른 응답 시간의 차이 비교 (Comparison of the Difference in Response Time According to the Server Configuration Type of the Indoor Air Quality Improvement System)

  • 국중진
    • 반도체디스플레이기술학회지
    • /
    • 제22권1호
    • /
    • pp.59-63
    • /
    • 2023
  • Various devices have been emerging as a means of measuring indoor air quality, and among them, there are devices that support real-time remote monitoring through IoT technology and a cloud environment. To improve indoor air quality, based on the results determined by measuring devices, air purifiers or ventilation systems may need to be operated, and temperature and humidity control may be required. In this paper, we propose a design of indoor air quality measuring devices required for indoor air quality evaluation, and of the system needed to control relevant devices to improve indoor air quality through the interaction with the measuring devices. Currently, the servers for the interaction of indoor air quality devices and IoT devices are divided into conventional server type and serverless type, comparing the differences in response time of IoT devices to changes of indoor air quality.

  • PDF

Comparison of 3D Reconstruction Methods to Create 3D Indoor Models with Different LODs

  • Hong, Sungchul;Choi, Hyunsang
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.674-675
    • /
    • 2015
  • A 3D indoor model becomes an indiscernible component of BIM (Building Information Modeling) and GIS (Geographic Information System). However, a huge amount of time and human resources are inevitable for collecting spatial measurements and creating such a 3D indoor model. Also, a varied forms of 3D indoor models exist depending on their purpose of use. Thus, in this study, three different 3D indoor models are defined as 1) omnidirectional images, 2) a 3D realistic model, and 3) 3D indoor as-built model. A series of reconstruction methods is then introduced to construct each type of 3D indoor models: they are an omnidirectional image acquisition method, a hybrid surveying method, and a terrestrial LiDAR-based method. The reconstruction methods are applied to a large and complex atrium, and their 3D modeling results are compared and analyzed.

  • PDF

가을철 도심지역 학교교사의 실내환경 측정연구 (Measurement of Classroom Air Quality in large cities in autumn)

  • 김윤덕;서동연
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.37-42
    • /
    • 2010
  • Together with the concern about the indoor air quality as sick house syndrome, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. The law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. School also have its own indoor air quality guideline. Indoor air quality in school is very important because, children who very weak to indoor pollutants reside long time in there. The purpose of this paper is to to survey indoor air quality in school by field measurement. Field measurements were performed in 11 schools which were selected from 3 major cities(Incheon, Dae-jeon, chuncheon) in korea, Totally concentration of indoor pollutants were determined in 32 classroom. Target air pollutants were TVOC, formaldehyde, dust, CO, CO2. For the result of this investigation, Indoor air quality in classroom was very poor and it was found that some pollutants(TVOC, float bacteria) exceed the guideline.

온도 및 습도 조건에 따른 침실 공기환경에 관한 연구 (A Study on the Indoor Air Quality in the bedroom with respect to Temperature and Humidity conditions)

  • 김동규;김세환
    • KIEAE Journal
    • /
    • 제11권3호
    • /
    • pp.31-36
    • /
    • 2011
  • People spend most of their time inside buildings recently, so the indoor air quality is one of the most important factors to human health. Furthermore, minimum energy use with proper ventilation systems for pleasant indoor environment is necessary because of energy shortage over the world. The concern to maintain proper indoor air quality at home has been increased, and a proper indoor air quality is continuously requested by the residents. By measuring and analyzing the density fluctuation of $CO_2$ through indoor humidity and testing personal reactions regarding comfort condition, we can obtain a way to effective ventilation. Heat and carbon dioxide emissions from resident's metabolism and construction materials could be the causes of indoor air pollution. If these materials stay indoors for a long time, it could directly influence the resident's health condition with diseases. It also leads massive energy use. Therefore, the way to save energy and to have effective control of indoor ventilation is needed. This study presented the control method of bedroom ventilation by $CO_2$ concentration change and subjective evaluation.

Towards Quantitative Assessment of Human Exposures to Indoor Radon Pollution from Groundwater

  • Donghan Yu;Lee, Han-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제17권E2호
    • /
    • pp.43-51
    • /
    • 2001
  • A report by the national research council in the United States suggested that many lung cancer deaths each year be associated with breathing radon in indoor air. Most of the indoor radon comes directly from soil beneath the basement of foundations. Recently, radon released from groundwater is found to contribute to the total inhalation risk from indoor air. This study presents the quantitative assessment of human exposures to radon released from the groundwater into indoor air. At first, a three-compartment model is developed to describe the transfer and distribution of radon released from groundwater in a house through showering, washing clothes, and flushing toilets. Then, to estimate a daily human exposure through inhalation of such radon for an adult. a physiologically-based pharmacokinetic(PBPK) model is developed. The use of a PBPK model for the inhaled radon could provide useful information regarding the distribution of radon among the organs of the human body. Indoor exposure patterns as input to the PBPK model are a more realistic situation associated with indoor radon pollution generated from a three-compartment model describing volatilization of radon from domestic water into household air. Combining the two models for inhaled radon in indoor air can be used to estimate a quantitative human exposure through the inhalation of indoor radon for adults based on two sets of exposure scenarios. The results obtained from the present study would help increase the quantitative understanding of risk assessment issues associated with the indoor radon released from groundwater.

  • PDF

공단지역과 시골지역 주택 실내, 실외 및 개인의 이산화질소 노출평가 (Indoor, Outdoor, and Personal Exposure to Nitrogen Dioxide Comparing Industrial Complex Area with Country Area)

  • 양원호;임성국;손부선
    • 한국환경보건학회지
    • /
    • 제34권3호
    • /
    • pp.183-187
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay, and outdoor levels. Various indoor and out-door combustion sources produce nitrogen dioxide ($NO_2$), which is a by-product of high temperature fossil fuel combustion. Especially, the presence of gas ranges and smoking have been identified as major factors contributing to indoor $NO_2$ exposures. In this study, we compared an industrial complex area with a country area by assessing the personal exposure to $NO_2$with measurements of indoor and outdoor $NO_2$ levels in residences and by house characteristics and questionnaire. Personal exposure concentrations were significantly correlated with indoor $NO_2$ concentrations of residences in both the industrial complex area and the country area with correlation coefficients of 0.561 and 0.664, respectively, compared to outdoors. Multiple regression analysis, indicated that indoor $NO_2$ levels in residences were only affected by outdoor levels (p = 0.000) in spite of higher indoor sources such as smoking. Therefore, it is suggested that outdoor air quality as well as indoor air quality should be considered in the reduction of the personal exposure to air pollutants.

여름철 대도심 학교교실의 실내공기환경 측정연구 (Measurement of Classroom Air Quality in large cities in summer)

  • 김윤덕
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.63-74
    • /
    • 2007
  • Together with the concern about the indoor all quality as sick house syndrome, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. In Dec 2005, the law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. School also have its own indoor air quality guideline, Indoor air quality in school is very important because, children who very weak to indoor pollutants reside long time in there. The purpose of this paper is to survey indoor air qualify in school by field measurement. Field measurements were performed in 11 schools which were selected from 3 major cities(Incheon, Dae-jeon, chuncheon) in korea, during July, 2004. Totally concentration of Indoor pollutants were determined in 27 classroom. Target air pollutants were TVOC, formaldehyde, dust, CO, CO2 and NO2. For the result of this investigation, Indoor air quality in classroom was very poor and it was found that some pollutants (TVOC, float bacteria) exceed the guideline.

Analysis on Indoor Garden Technology Trends Based on Patent Search

  • Hong, Kwang-pyo;LEE, Hyuk-jae
    • International Journal of Advanced Culture Technology
    • /
    • 제7권4호
    • /
    • pp.40-48
    • /
    • 2019
  • Indoor gardens tailored to suit individual tastes offer a place to enjoy plants and to relax to city dwellers to relieve stress from city life. However, there are technical issues to build such indoor gardens. To offer solutions to technical issues, this study aims to analyze development phases of indoor garden-related technologies by studying available patents in detail. Also, the study aims to understand current status and future direction of technologies by examining technological trends for introduction of indoor gardens. Brainstorming method was used to understand technology trends and as a result, two groups were identified for technical features of indoor gardens: indoor greening technology and rest area for users. An analysis on selected patents showed that the number of patents increased until 2010 and declined gradually afterwards. Korea ranked the highest in the number of patents grant followed by USA, Japan and Europe. Similar order was observed with the number of patents granted by nationality of applicants. The number of patents granted by nationality was the highest for Korean nationals. For indoor greening technologies, patents related to structure from 2007 were mostly concentrated in the areas of irrigation control and environment control for plants and vegetation. For rest area related technologies, patent related to structure showed a repetitive pattern of increasing and decreasing, but overall, on downtrend. For further development and dissemination of indoor gardening technology, more R&D work is needed with focus on environmental control technology for designing suitable environment for both human and plant.

지하상가 실내외 및 지하철의 온도와 습도에 따른 Formaldehyde 거동(II) (Behavior of Formaldehyde Concentration by Temperature and Humidity of Indoor and Outdoor in Underground Shopping Center and Subway(II))

  • 권우택
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.67-75
    • /
    • 1994
  • Formaldehyde has been in widespread industrial use since World War II . Numerous sources of formaldehyde are present in the indoor environment. Additionally, the current trend toward tighter, more energy efficient buildings with lower ventilation rates has led to increase concentrations of this and other pollutants generated indoors. In this paper, the field survey was carried out once a month from January to MarctL 1994 to measure indoor and outdoor formaldehyde concentration in several underground locations in Seoul. The results could be summarized as follows : 1. At Yang- jae underground shopping center, the mean formaldehyde concentration was 77.8ppb for indoor and 68.4ppb for outdoor. At Ban- po underground shopping center, it was 175.8ppb for indoor and 127.3ppb for outdoor. At Jam- shil underground shop ping center, it was 135.2ppd for indoor and 34.6ppb for outdoor. Indoor the No.2 sub way line, it was 105.6ppb. The formaldehyde concentration using Berge equation was as follows : At Yang- jae underground shopping center, the mean formaldehyde concentration was 85.99ppb for indoor and 72.75ppb for outdoor At Ban- po underground shopping center, it was 254. 17ppb for indoor and 138.14ppb for outdoor. At Jam- shil underground shopping center, it was 249.13ppb for indoor and 36.87ppb for outdoor. Indoor the No.2 subway line, it was 131.73ppb. 3, The result of correlation analysis indicated that the relationship between temperature and formaldehyde concentration is very high( $\gamma $= 0.831 ∼ 0.974). 4. Also, the relationship between humidity and formaldehyde concentration is variant ($\gamma $ = 0.246 ∼0.999). 5. The mean formaldehyde concentration indoor and outdoor Ban- po underground shop ping center and indoor Jam- shil underground shopping center and indoor the No.2 sub way line exceed the American Society of Heating, Refrigeration, Air- conditioning Engineers( ASHRAE) stflndard of 100ppb(120 $\mu $g/m$^{3}$).

  • PDF