• Title/Summary/Keyword: indirect comparison

Search Result 366, Processing Time 0.026 seconds

Comparisons of Index Numbers: An Application to Sawmills and Planing Mills Industry of U.S.

  • Ahn, SoEun
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.2 s.159
    • /
    • pp.82-89
    • /
    • 2005
  • The purpose of this paper is to investigate index numbers by conducting various comparisons among the widely used index formulas. The comparison is considered in three ways; 1) divergences in the magnitudes of index numbers due to the use of different formulas (Laspeyres, Paasche, Fisher, and Tornqvist); 2) the effect of selection of base year (fixed-year base vs. chain-type); 3) the degree of approximation of indirect to direct quantity index. The empirical application is to sawmills and planing mills industry of U.S. using a national time series data covering years of 1948-2000. The results show that the differences between Laspeyres and Paasche index can be substantial in some cases while the difference between Fisher and Tornqvist index is minimal. We also confirm that the selection of base year can cause significant divergences, especially when the variables undergo rapid price or quantity changes over time. We find that indirect quantity index approximates direct quantity index reasonably well in U.S. sawmill industry.

Comparison of measurement uncertainty calculation methods on example of indirect tensile strength measurement

  • Tutmez, Bulent
    • Geomechanics and Engineering
    • /
    • v.12 no.6
    • /
    • pp.871-882
    • /
    • 2017
  • Indirect measure of the tensile strength of laboratory samples is an important topic in rock engineering. One of the most important tests, the Brazilian strength test is performed to obtain the tensile strength of rock, concrete and other quasi brittle materials. Because the measurements are provided indirectly and the inspected rock materials may have heterogeneous properties, uncertainty quantification is required for a reliable test evaluation. In addition to the conventional measurement evaluation uncertainty methods recommended by the Guide to the Expression of Uncertainty in Measurement (GUM), such as Taylor's and Monte Carlo Methods, a fuzzy set-based approach is also proposed and resulting uncertainties are discussed. The results showed that when a tensile strength measurement is measured by a laboratory test, its uncertainty can also be expressed by one of the methods presented.

Development of indirect EFBEM for radiating noise analysis including underwater problems

  • Kwon, Hyun-Wung;Hong, Suk-Yoon;Song, Jee-Hun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.3
    • /
    • pp.392-403
    • /
    • 2013
  • For the analysis of radiating noise problems in medium-to-high frequency ranges, the Energy Flow Boundary Element Method (EFBEM) was developed. EFBEM is the analysis technique that applies the Boundary Element Method (BEM) to Energy Flow Analysis (EFA). The fundamental solutions representing spherical wave property for radiating noise problems in open field and considering the free surface effect in underwater are developed. Also the directivity factor is developed to express wave's directivity patterns in medium-to-high frequency ranges. Indirect EFBEM by using fundamental solutions and fictitious source was applied to open field and underwater noise problems successfully. Through numerical applications, the acoustic energy density distributions due to vibration of a simple plate model and a sphere model were compared with those of commercial code, and the comparison showed good agreement in the level and pattern of the energy density distributions.

THE COMPARISON OF SHEAR STRENGTH AND BRACKET PLACEMENT BETWEEN BONDING TECHNIQUES (접착술식에 따른 전단강도 및 Bracket위치의 비교)

  • Pak, Yun-Kyong;Kook, Yoon-A;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.513-520
    • /
    • 1991
  • The purpose of this study was to compare the bracket placement and the shear bond strength of indirect-bonded brackets with those of direct-bonded ones. Forty eight extracted human teeth were collected and attached with brackets and tested on shear bond strength, using Instron. Fourteen patients from Wonkwang University Dental Hospital were selected for direct bonding of brackets and their teeth were measured on bracket angulation and bracket height. The obtained results were as follows: 1. The shear bond strengths of incisors were higher in direct-bonding,group, rather than in-direct-bonding group. But, the shear bond strength of premolars showed no significant differences between groups. 2. The bracket angulations of indirect-bonding group were preciser than those of direct-bonding group, especially in upper first premolars, lower lateral incisors, canines, premolars. 3. In bracket height, there were no significant differences between groups.

  • PDF

Comparison of Collecting Performance according to Contact Types of Heatpipe in Vacuum Tube Type Solar Collector (진공관형 집열기 히트파이프 접촉방식에 따른 집열성능 비교)

  • Yun, Ji-Hun;Jeong, In-Guk;Yi, Chung-Seob;Chung, Kyung-Teak;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.122-127
    • /
    • 2011
  • In this study, it was compared collecting performance according to contact types between heatpipe and manifold of vacuum tube type solar collector. Between two types, direct contact type is better in collecting performance. On the other hand, Indirect type have advantage in maintenance. In the result of numerical analysis, As the temperature of heatpipe and flow rate of working fluid increased, difference of outlet mean temperature of two types became large. Also, it could be confirmed, as contact resistance between heatpipe and copper tube in indirect type increased, the difference increased too. Useful data in selection and design in vacuum tube type solar collector were proposed by the results of numerical analysis.

An Indirect Model Reference Adaptive Fuzzy Control for SISO Takagi-Sugeno Model

  • Cho, Young-Wan;Park, Chang-Woo;Lee, Ki-Chul;Park, Mignon
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.1
    • /
    • pp.32-42
    • /
    • 2001
  • In this paper, a parameter estimator is developed for the plant model whose structure is represented by the Takagi-Sugeno model. The essential idea behind the on-line estimation is the comparison of the measured stated with the state of an estimation model whose structure is the same as that of the parameterized model. Based on the parameter estimation scheme, and indirect Model Reference Adaptive Fuzzy control(MRAFC) scheme is proposed to provide asymptotic tracking of a reference signal for the systems with uncertain for slowly time-varying parameters. The developed control law and adaptive law guarantee the boundedness of all signals in the closed-loop systems. In addition, the plant state tracks the state of the reference model asymptotically with time for any bounded reference input signal.

  • PDF

Comparison of shearbond strength between metal and indirect resin according to the different conditionings (표면처리에 따른 금속과 간접복합레진간의 전단결합강도 비교연구)

  • Choi, Su-Young;Choi, Hyunmin;Moon, Hong-Seok;Shim, June-Sung;Park, Young-Bum;Lee, Geun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.264-271
    • /
    • 2017
  • Purpose: The purpose of this study is to investigate the differences in bond strength of four different indirect composites to the gold alloy and Ni-Cr alloy according to type of metal surface treatment after water storage. Materials and methods: Type IV gold alloy and Ni-Cr alloy were used for casting alloy while four types of indirect composite resins (Gradia, Tescera Sinfony and in;joy) were used in this study. Metal specimens were produced by casting and total of 240 specimens (60 specimens per one indirect composite group) were prepared. After bonding indirect composite resin and undergoing 24 hours of polymerization, customized jig was attached to the metal specimen and shear bond strength were measured using universal testing machine. Also, differences in shear bond strength before and after water storage for 240 hours were also measured. Results: In the measurement of shear bond strength according to the metal surface treatments, bead group showed high strength followed by loop and flatting group (P<.05). After being stored in water bath for 240 hours, Gradia showed statistically significant high bond strength compared to other indirect composite resins in all groups (P<.05). Conclusion: Shearbond strength was found to be different according to type of metal surface treatment and type of metal used after storage in water. Further studies need to be developed for clinical practices as three are still problems of microleakage, stain or wear.

Concentration of Urinary Cotinine and Frequency of Sister Chromatid Exchange in Lymphocytes among Male Adolescents (일부 청소년의 요중 코티닌 농도와 자매염색분체 교환빈도)

  • Paek, Dong-Ki;Lee, Tae-Yong;Roh, Young-Man;Lee, Yeon-Kyeng;Cho, Young-Chae;Lee, Dong-Bae;Chang, Seong-Sil
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.3
    • /
    • pp.269-276
    • /
    • 2001
  • Objectives : To evaluate the internal burden and hazardous effects associated with smoking in middle and high school students. Methods : We analysed urinary cotinine(U-cotinine) concentrations and the frequency of Sister Chromatid Exchanges (SCE). A comparison was done of U-cotinine concentrations and the frequency of SCE in peripheral lymphocytes across school levels (middle vs. high) and smoking types (direct: daily & occasional smoking, indirect; usual indirect & non-smoking), in 122 males. Results : The middle school student group comprised 6.8% daily smokers, 15.9% occasional smokers, 40.9% daily indirect smokers, and 35.4% nonsmokers, while the high school student group comprised 18.0%, 20.5%, 35.7%, and 21.8%, respectively. The U-cotinine concentration and the frequency of SCE among the middle school students were $79.11{\mu}g/l$ and 2.0 per cell, respectively, which were significantly lower than the $146.85{\mu}g/l$ (p=0.078) and 2.6 per cell (p=0.005) of the high school students. Among the 40 direct smokers, these two biomarkers were $236.66{\mu}g/l$ and 2.59 per cell, significantly higher than the $67.33{\mu}g/l$ (p=0.0001) and 2.1 per cell (p=0.003) among indirect smoking groups. The variation in individual U-cotinine concentration ranged widely in both the indirect and direct smoking groups. Conclusion : Urinary cotinine concentrations and the frequency of Sister Chromatid Exchange seem to objectively and effectively evaluate student exposure whether it was direct or indirect smoking. Consequently, these biomarkers may be useful in monitoring the objective efficacy of anti-smoking programs in adolescent populations.

  • PDF

Study on the comparison result of Machine code Program (실행코드 비교 감정에서 주변장치 분석의 유효성)

  • Kim, Do-Hyeun;Lee, Kyu-Tae
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.1
    • /
    • pp.37-44
    • /
    • 2020
  • The similarity of the software is extracted by the verification of comparing with the source code. The source code is the intellectual copyright of the developer written in the programming language. And the source code written in text format contains the contents of the developer's expertise and ideas. The verification for judging the illegal use of software copyright is performed by comparing the structure and contents of files with the source code of the original and the illegal copy. However, there is hard to do the one-to-one comparison in practice. Cause the suspected source code do not submitted Intentionally or unconsciously. It is now increasing practically. In this case, the comparative evaluation with execution code should be performed, and indirect methods such as reverse assembling method, reverse engineering technique, and sequence analysis of function execution are applied. In this paper, we analyzed the effectiveness of indirect comparison results by practical evaluation . It also proposes a method to utilize to the system and executable code files as a verification results.

Comparison procedure in evaluation analysis of source code comparison on Embedded system (정보기기 소스코드 유사성 분석에서 목적물 검증)

  • Nam, SangYep;Kim, Do-Hyeun;Lee, Kyu-Tae
    • Journal of Software Assessment and Valuation
    • /
    • v.17 no.2
    • /
    • pp.31-38
    • /
    • 2021
  • In order to analyze the similarity of the source code object material, the source code on both sides must be able to be compiled and executed. In particular, in the case of hardware-integrated software, it is necessary to check whether the hardware interface matches. However, currently, the source code is provided in an incomplete state which is not original of source code used in developing steps. The complainant confirms that the executing characteristics are similar to their own in the expression and function of the output, and request an evaluation. When a source code compilation error occurs during the evaluation process, the experts draw a flowchart of the source code and applies the method of tracing the code flow for each function as indirect method. However, this method is indirect and the subjective judgment is applied, so there is concern about the contention of objectivity in the similarity evaluation result. In this paper, the problems of unverified source code similarity analysis and improvement directions are dealt with, through the analysis cases of source code disputes applied to embedded systems.