• 제목/요약/키워드: incisor teeth

검색결과 501건 처리시간 0.027초

상아질과 접착제 간의 계면양상 (INTERFACIAL MORPHOLOGY BETWEEN DENTIN AND ADHESIVES)

  • 강지영;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.183-192
    • /
    • 1995
  • The purpose of this study was to evaluate the effect of smear layer management on the interfacial morphology between dentin bonding system and dentin. Clearfil New Bond, Scotchbond Multipurpose, Prisma Universal Bond 3 and X-R Bond were used on the cervical dentinal surfaces of bovine incisor teeth. All of the dentin bonding systems were labeled with fluorescene in primer and rhodamine B in adhesive. Specimens of 2~3mm thichness were prepared by longitudinal and labiolingual sectioning. The interface between dentin bonding system and dentin was observed by flouresence imaging with a confocal laser scanning microscope. Following results were obtained. 1. In the specimen of Clearfil New Bond, dentinal tubules were widened by destruction of peritubular dentin in the course of treatment with phosphoric acid of high concentration. 2. Hybrid layer was observed in the specimen of Scotchbond Multipurpose and X-R Bond. 3. In the specimen of Prisma Universal Bond 3, the penetraton of adhesive was not observed clearly.

  • PDF

Effects of Dipping in Tooth Reserving Solution on Bond Strength of 4-META/MMA-TBB Dentin Bonding System.

  • Kubota, M.;Yanagidani, T.;Hashimoto, M.;Kudou, Y.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.569.1-569
    • /
    • 2001
  • The purpose of this investigation was to determine the effect of dipping in tooth reserving solution on bond strength of 4-META/MMA-TBB dentin bonding system. The flattened dentin surface of bovine lower incisor was used for this investigation. The tooth were dipped in the tooth reserving solution (ViaSpan; Du Pont Pharmatical / Teeth Server "NEO";Neo Dental Chemical products CO/LTD, Japan/ Saline, Fuso Chemical CO, LTD, Japan) for 30 min.(omitted)

  • PDF

치과용 부식제가 백서 법랑질 표면에 미치는 영향에 대한 주사전자현미경적 관찰 (OBSERVATION WITH SCANNING ELECTRON MICROSCOPE ON THE EFFECT OF THREE DENTAL ETCHANTS IN THE ENAMEL SURFACE OF ALBINO RATS)

  • 권택견
    • Restorative Dentistry and Endodontics
    • /
    • 제6권1호
    • /
    • pp.133-139
    • /
    • 1980
  • In this experiment, etching was performed on the incisor enamel surfaces of 13 Albino rats, weighted about 130gm, with both 30% and 50% concentrations of the phosphoric, citric acids, and EDTA solution for 60 seconds. Immediately after extraction of the animal teeth, laboratory procedures for scanning electron microscopic observations were made and the author derived the following conclusions: 1. On the enamel surface treated with 30% and 50% phosphoric acids, all of the periphery, center of the enamel rods, and the enamel matrices were severely etched. 2. In the etched with 30% citric acid group, only the small part of the enamel rods were etched out. In case of 50% citric acid the periphery, center of enamel rods were partially or entirely etched, and the intermatrix spaces were widened. 3. In the 30% and 50% of the EDTA etched groups, the periphery of the enamel rods explicitely were etched, and the spaces between matrices were widened.

  • PDF

Maxillary space closure using a digital manufactured Mesialslider in a single appointment workflow

  • Wilhelmy, Lynn;Willmann, Jan H.;Tarraf, Nour Eldin;Wilmes, Benedict;Drescher, Dieter
    • 대한치과교정학회지
    • /
    • 제52권3호
    • /
    • pp.236-245
    • /
    • 2022
  • New digital technologies, many involving three-dimensional printing, bring benefits for clinical applications. This article reports on the clinical procedure and fabrication of a skeletally anchored mesialization appliance (Mesialslider) using computer-aided design/computer-aided manufacturing (CAD/CAM) for space closure of a congenitally missing lateral incisor in a 12-year-old female patient. The insertion of the mini-implants and appliance was performed in a single appointment. Bodily movement of the molars was achieved using the Mesialslider. Anchorage loss, such as deviation of the anterior midline or palatal tilting of the anterior teeth, was completely avoided. CAD/CAM facilitates safe and precise insertion of mini-implants. Further, mini-implants can improve patient comfort by reducing the number of office visits and eliminating the need for orthodontic bands and physical impressions.

Effect of Stafne bone defect on the adjacent tooth: A review of the literature

  • Niknami, Mahdi;Parsa, Azin;Khodadadi, Zahra
    • Imaging Science in Dentistry
    • /
    • 제52권2호
    • /
    • pp.165-170
    • /
    • 2022
  • Purpose: This report presents a case of an unusual and rare presentation of Stafne bone defect (SBD) with apical resorption extending from the lower right lateral incisor to the right first premolar. A systematic search of the current literature on cases where SBD affected the adjacent teeth was conducted. Materials and Methods: From 259 identified articles, 114 studies were examined, containing 12 individuals with a mean age of 41.58 years. Ten cases in the anterior mandible and 2 in the posterior mandible were found. Results: The results of SBD varied from apical blunting to severe root resorption, and some cases showed close apical contact with the lesion or involvement of the root without any effect. Conclusion: SBD is an unusual incidental finding in the anterior region of the mandible, and unexpected behavior of the lesion, such as root resorption, must be considered.

Persistent Gingival Swelling and Fistula Obscured Horizontal Root Fracture: A Case Report

  • Juyeon, Cho
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.147-151
    • /
    • 2022
  • Horizontal root fracture (HRF) is a result of trauma to teeth and periodontium, which implies severe injury to cementum, dentin, and pulp. This is a rare case of HRF in the maxillary lateral incisor of a 62-year-old male who only presented persistent gingival swelling, fistula, and dull pain at first. An apical radiolucency of unknown origin turned out to be a result of hidden HRF at the coronal third level that was later visualized radiographically during endodontic treatment. The tooth was scheduled to be extracted upon the patient's agreement. The purpose of this report is to alert clinicians about the importance of diagnosing HRF through thorough clinical and radiographic examinations. Where there is persistent fistula without proper cause, HRF should be considered as a causative factor, and the diagnosis could be effective with aid of cone beam computed tomography, electronic root apex locator, as well as other clinical signs.

Recurrent odontogenic fibroma in a Formosan rock macaque (Macaca cyclopis)

  • Yeonsu Oh;Jongwoog Choi;Ho-Seong Cho
    • 한국동물위생학회지
    • /
    • 제47권1호
    • /
    • pp.49-53
    • /
    • 2024
  • The animal in this case report was a 10-year-old male Taiwanese monkey (Macaca cyclopis) kept at a zoo of South Korea. Over the last three years, a cauliflower-shaped masses have been noted on the gingiva near the incisor and molar teeth on right maxilla. Consequently, this monkey have undergone surgical removal of the mass annually. Grossly masses showed pinkish color. Histopathological findings, typical spindle cell tumor composed of collagen fibers. Infiltration by plasma cells and lymphocytes is found unrelated to ulceration of the surface epithelium. This is the first report of peripheral odontogenic fibroma in a Formosan rock macaque.

골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석 (Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage)

  • 김찬년;성재현;경희문
    • 대한치과교정학회지
    • /
    • 제33권5호
    • /
    • pp.339-350
    • /
    • 2003
  • 본 연구에서는 활주법을 이용한 전치부 후방 견인시 micro-implant의 다양한 수직적 위치와 전치부에서 힘의 적용점에 따른 치아 이동 양상을 관찰하여 공간 폐쇄시 전치부의 설측 경사와 정출력을 방지할 수 있는 micro-implant의 위치와 전치부 힘의 적용점의 위치를 알아보고자 하였다. 유한 요소 모델을 이용하여 제1소구치가 발거된 상악 치열궁 형태를 제작하고 $.022"{\times}.028"$ 슬롯 브라켓을 모형화하여 치아에 부착시켰다. $.019"{\times}.025"$ stainless steel 선재를 3차원 beam모형으로 제작하고 상악 측절치와 견치 브라켓 사이의 선재 상에 $.032"{\times}.032"$ 크기의 stainless steel hook을 수직으로 8mm의 높이로 형성하였으며, 선재로부터 2mm높이에서 1mm간격으로 8mm까지 힘 적용점을 설정하였다. 지름 1.2mm,길이 6mm의 micro-implant를 제2소구치와 제1대구치 사이의 치조골에 선재로부터 4mm에서 10mm까지 2mm간격으로 4개를 위치시켰다 각각의 micro-implant와 전치부 hook에 150gm의 힘을 적용시켜 다양한 힘 적용점에 따른 치아의 초기 변위를 분석하여 다음의 결과를 얻을 수 있었다. 1. Micro-implant 높이가 4m일 경우 5mm이하의 전치부 hook 높이에서는 전치부 설측 경사 이동이 일어났으며 전치부 hook 높이가 6m이상 되었을 때 전치부 순측 경사 이동이 일어났다. 2. Micro-implant높이가 6mm일 경우 5mm이하의 전치부 hook높이에서 전치부 설측 경사 이동이 일어났으며 전치부 hook 높이가 6mm 이상 되었을 때 전치부 순측 경사 이동이 일어났다 이것은 4mm micro-implant에서의 실험결과와 유사한 이동 양상을 나타내었지만, micro-implant높이가 6mm일 때 전치부 설측 경사 이동이 좀더 감소하였다. 3. Micro-implant높이가 8m일 경우 전치부 hook높이가 2mm일 때 전치의 설측 경사 이동이 일어났으며 3mm이상의 전치부 hook 높이에서 순측 경사 이동이 비례적으로 증가하였다. 4. Micro-implant높이가 10mm일 경우 전치부 hook 높이가 2mm 이상에서 전치의 순측 경사 이동이 비례적ㅇ로 증가하였다. 5. 전치부 hook 높이가 증가할수록 전치의 순측 경사 이동이 증가되지만 선재의 뒤틀림에 의한 변형이 증가되므로 견치와 소구치 부위에서 정출력이 발생하는 바람직하지 못한 치아 이동 양상이 일어났다. 6. Micro-implant를 이용한 상악 5전치 후방 견인시 구치부의 이동은 선재와 브라켓 사이의 마찰력에 의해서 원심경사 이동이 발생하였다.

유치열과 혼합치열기 어린이의 상악 절치부 외상 (TRAUMATIC INJURIES TO THE UPPER INCISORS IN PRIMARY AND MIXED DENTITION)

  • 정주현;이제호;김성오;최병재
    • 대한소아치과학회지
    • /
    • 제31권2호
    • /
    • pp.290-298
    • /
    • 2004
  • 현대인의 생활양식과 환경이 도시화 및 인공화되고 취미활동이 다양화됨에 따라 외상을 받을 수 있는 요인들이 증가하고 특히 어린이 활동량이 많아져 외상의 기회가 잦아지고 있다. 어린이에서 외상이 발생하는 경우, 어린이의 일상적인 활동 뿐 아니라, 사회성 및 정서 발달에도 영향을 미칠 수 있으며 그 보호자에게도 부정적인 영향을 미칠 수 있기에 외상의 발생 빈도를 줄이고 예방하는 것이 중요하다. 본 연구는 유치열과 혼합치열기에 발생하는 치아 외상을 예방하기 위한 기초 자료를 얻기 위하여, 특히 구강악안면부의 외상시 치아 외상을 가장 많이 받는 상악 유절치와 영구절치를 연구하기 위하여, 2002년 6월부터 2003년 5월까지 연세대학교 치과대학병원 소아치과에 내원한 유치열과 혼합치열기의 신환 8,799명중 상악 절치부 외상을 주소로 내원한 어린이 487명(남자 316명, 여자 171명 )의 상악 절치 955개(유절치 543개, 영구절치 412개)를 조사하여 다음과 같은 결과를 얻었다. 1. 상악 절치부 외상이 호발하는 나이는 유절치에서 $1{\sim}3$세, 영구절치에서 7세였으며 남자대 여자의 비율은 1.85:1이었다. 2. 상악 절치부 외상은 유절치와 영구절치 모두 오후 시간에 많이 발생하였으며, 유절치는 외상 장소로 집이 가장 많았고(44.1%), 영구절치는 길에서 다치는 경우가 가장 많았다(17.5%). 3. 외상의 원인으로 유절치와 영구절치 모두 넘어져 다치는 경우가 가장 많았으며(39.8%, 12.9%), 다음으로 부딪히는 경우가 많았다(22.2%, 6.0%). 유절치에서는 다음으로 떨어져 다치는 경우 교통사고, 폭력과 운동에 의한 외상 순이었으며, 영구절치에서는 폭력, 운동, 교통사고, 떨어져 다치는 순이었다. 4. 조사대상 어린이 1명당 유절치는 1.6개, 영구절치는 2.8개에 외상을 입었다. 5. 유절치와 영구절치 모두에서, 치관 파절 양상은 치수미노출 치관 파절이 많았고, 치주조직 외상 양상은 아탈구가 가장 많았다. 최근 어린이의 단체 생활이나 운동과 취미 활동에 참여하는 나이가 예전에 비하여 점차 낮아지고 있어, 이번 연구 결과와 같이, 외상이 발생하는 나이 역시 지속적으로 낮아질 수 있다. 나이에 따른 어린이의 외상을 받는 장소는 특별한 곳이 아닌, 집이나 학교와 같은 일상의 생활공간이기 때문에 단순한 주의만으로도 외상의 발생을 예방할 수 있을 것으로 사료된다.

  • PDF

합지증 수술 병력이 있는 어린이에서 하악 거대 협소대의 외과적 처치 (SURGICAL TREATMENT OF HEAVY MANDIBULAR LABIAL FRENUM IN PRE-SCHOOL CHILD WITH A HISTORY OF SYNDACTYLY SURGERY : A CASE REPORT)

  • 박지원;정의원;송제선
    • 대한장애인치과학회지
    • /
    • 제9권2호
    • /
    • pp.103-106
    • /
    • 2013
  • 본 증례에서는 하악 거대 협소대가 하악 양측 유측절치에 높게 위치하여 치은 퇴축과 유치 조기 상실 및 입술의 운동 제한을 야기한 경우로, 근단변위부분층 판막술을 동반한 협소대절제술을 시행하였다. 부착치은의 양은 인접치와 유사하게 회복되었고, 제거된 소대는 정상위치에 부착되어 있었고, 해당 부위의 영구치는 정상적으로 맹출하였다.