• 제목/요약/키워드: incidence angle of X-ray

검색결과 29건 처리시간 0.027초

Initial Growth and Surface Stability of 1,4,5,8,9,11-Hexaazatriphenylene-exanitrile (HATCN) Thin Film on an Organic Layer

  • Kim, Hyo Jung;Lee, Jeong-Hwan;Kim, Jang-Joo;Lee, Hyun Hwi
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.192.2-192.2
    • /
    • 2013
  • Crystalline order and surface stability of 1,4,5,8,9,11-hexaazatriphenylene-hexanitrile (HATCN) thin films on organic surface were investigated using grazing incidence wide angle x-ray scattering and x-ray reflectivity measurements. In the initial growth regime (less than 20 nm), HATCN molecules were stacked to low crystalline order with substantial amorphous phase. Meanwhile, a thicker film with 50 nm thickness showed high crystalline order of hexagonal phase with three different orientational domains. The domain distribution was quantitatively obtained as a function of tilted angle. By an organic-inorganic interface formation of IZO/HATCN thin film from an indium zinc oxide (IZO) electrode deposition, the surface stability of HATCN film was investigated and the sharp interface was confirmed by the x-ray reflectivity measurement.

  • PDF

Real-time X-ray Scattering as a Nanostructure Probe for Organic Photovoltaic Thin Films

  • 이현휘;김효정;김장주
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.181-181
    • /
    • 2013
  • Recently, nanostructure and the molecular orientation of organic thin films have been largely paid attention due to its importance in organic electronics such as organic thin film transistors (OTFTs), organic light emitting diodes (OLEDs), and organic photovoltaics (OPVs). Among various methods, the diffraction and scattering techniques based on synchrotron x-rays have shown powerful results in organic thin film systems. In this work, we introduce the in-situ annealing system installed at PLS-II (Pohang Light Source II) for organic thin films by simultaneously conducting various x-ray scattering measurements of x-ray reflectivity, conventional x-ray scattering, grazing incidence wide angle x-ray scattering (GI-WAXS) and so on. Using the in-situ measurement, we could obtain real time variation of nanostructure as well as molecular orientation during thermal annealing in metal-phthalocyanine thin films. The variation of surface and interface also could be simultaneously investigated by the x-ray reflectivity measurement.

  • PDF

Circularly polarized soft X-ray generation by Co/Pt thin film polarizer with perpendicular magnetic anisotropy

  • Lee, Sang-Hyuk;Huang, Lin;Lee, Jae-Woong;Kim, Namdong;Shin, Hyun-Joon;Jeong, Jong-Ryul;Hwang, Chanyong;Kim, Dong-Hyun
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1196-1200
    • /
    • 2018
  • We have experimentally demonstrated circular polarization generation from linear polarized soft X-ray at synchrotron by adopting a thin magnetic film polarizer. Polarizer is composed of Co/Pt multilayer with a perpendicular magnetic anisotropy, which allows us to easily accommodate without needing any tilting angle into the measurement setup since the circular polarization is generated for the X-ray with normal incidence and transmission. Generated circular polarization is examined by observing magnetic domain features based on the X-ray magnetic circular dichroism, where~11% of circular component is estimated compared to the case of full circular polarization.

열형광선량계(도시메터타입 : PB-3)의 방향의존성에 관한 연구 (A Study on the Angular Dependence of the PB-3 Dosimeter Using Teledyne 9150 TLD Reader System)

  • 손중권;김종경;윤석철
    • Journal of Radiation Protection and Research
    • /
    • 제19권3호
    • /
    • pp.189-198
    • /
    • 1994
  • Teledyne 9150 판독장치에서 사용되는 PB-3 열형광선량계의 방향의존성에 관한 실험을 실시하였고 ANSI N13.11-1992에 의거하여 성능실험을 실시하였다. 조사선원은 $^{137}Cs$과 X선이었다. Teledyne 9150 선량판독장치는 $0^{\circ}$에서는 모든 경우에 방향의존성에 대한 성능시험범주를 만족하였다. 그러나 저에너지 X선의 경우, ${\pm}60^{\circ}$에서는 방향의존성에 대한 성능시험범주를 만족할 수 없었으며 $^{137}Cs$은 모든 경우에 방향의존성에 대한 성능시험범주를 만족하였다.

  • PDF

S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구 (The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function)

  • 박명주;주영철;김민석;육정원;김한용;김동환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

Small-Angle X-ray Scattering Station 4C2 BL of Pohang Accelerator Laboratory for Advance in Korean Polymer Science

  • Yoon, Jin-Hwan;Kim, Kwang-Woo;Kim, Je-Han;Heo, Kyu-Young;Jin, Kyeong-Sik;Jin, Sang-Woo;Shin, Tae-Joo;Lee, Byeong-Du;Rho, Ye-Cheol;Ahn, Byung-Cheol;Ree, Moon-Hor
    • Macromolecular Research
    • /
    • 제16권7호
    • /
    • pp.575-585
    • /
    • 2008
  • There are two beamlines (BLs), 4C1 and 4C2, at the Pohang Accelerator Laboratory that are dedicated to small angle X-ray scattering (SAXS). The 4C1 BL was constructed in early 2000 and is open to public users, including both domestic and foreign researchers. In 2003, construction of the second SAXS BL, 4C2, was complete and commissioning and user support were started. The 4C2 BL uses the same bending magnet as its light source as the 4C1 BL. The 4C1 BL uses a synthetic double multilayer monochromator, whereas the 4C2 BL uses a Si(111) double crystal monochromator for both small angle and wide angle X-ray scattering. In the 4C2 BL, the collimating mirror is positioned behind the monochromator in order to enhance the beam flux and energy resolution. A toroidal focusing mirror is positioned in front of the monochromator to increase the beam flux and eliminate higher harmonics. The 4C2 BL also contains a digital cooled charge coupled detector, which has a wide dynamic range and good sensitivity to weak scattering, thereby making it suitable for a range of SAXS and wide angle X-ray scattering experiments. The general performance of the 4C2 BL was initially tested using standard samples and further confirmed by the experience of users during three years of operation. In addition, several grazing incidence X-ray scattering measurements were carried out at the 4C2 BL.

경추 정면 검사에서 방사선 입사각에 관한 연구 (A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination)

  • 정성운;임청환;한범희;정홍량;주영철;박미자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.83-92
    • /
    • 2012
  • 경추 정면 방사선검사시 하악골, 후두골의 겹침방지, 경추 추체의 배열 및 관절의 형태 등을 관찰하기 위하여 X선 입사각을 머리 방향으로 $15{\sim}20^{\circ}$를 주고 있는 것이 보편적이다. 하지만 한국인의 체형에 맞는 입사각에 대한 연구는 거의 이루어지지 않고 있다. 이에 본 연구에서는 한국인에 적합한 입사각을 찾고, 방법을 제시하는데 목적이 있다. 입사각을 측정하기 위하여 서산에 위치한 S병원을 내원한 환자 1,044명을 대상으로 하였으며, 제 2번~제 5번 경추의 길이, 피사체-영상판 거리(OID), 제2번경추(axis)의경사도, 초점-영상판 간거리(FID)를 측정하였으며, 연령대 성별에 대한 평균값을 측정하여 적용공식에 의하여 입사각을 산출하였다. 경추 제2번~제5번의 평균길이는 6cm 이였으며, 10대부터 20대까지는 경추의 길이가 커지고 30대 이후로는 경추의 길이가 작아졌으며, 남성과 여성의 차이는 약 1cm 차이가 나타났다(p<.001). OFD는 연령대, 성별과 상관없이 거의 같은 값이 측정이 되었다. 제2번 경추(axis)의 경사도는 10대와 20대는 경사도가 증가하였지만, 30대 이후로는 작게 나타났다. 또한 남성과 여성은 약 $2^{\circ}$차이가 났다(p<.001). FID의 측정 결과, 연령대, 성별과 상관없이 거의 같은 값이 측정되었으며, 이 값으로 입사각을 측정한 결과, 10대는 $15.9^{\circ}$, 20대 $16.9^{\circ}$, 30대 $16.6^{\circ}$, 40대 $16.2^{\circ}$, 50대 $15.9^{\circ}$, 60대 $14.5^{\circ}$로 측정되었다. 10대와 20대까지 입사각이 증가하였지만, 30대 부터는 입사각이 작게 나타났다. 또한 10대는 남성과 여성이 같은 값으로 측정이 되었고, 20대부터는 남성과 여성이 $2^{\circ}$ 차이가 나타났다. 입사각과 제 2번~제 5번 경추의 길이측정, OID, 제 2번 경추의 경사도, FID와의 상관관계를 실시하였고, 입사각과 모두 유의한 상관관계가 나타났다(p<.001). 본 연구에서 경추의 평균 길이, OID, FID, 제2번 경추(axis)의 경사도에 따라서 입사각이 다르게 나타났고, 성별과 연령에 따라 입사각이 다른 것을 알 수 있었다. 그러므로 경추 정면검사 시 연령, 성별을 고려하여 입사각을 설정하면서 검사를 시행하여야 함이 사료되며, 향후 경추검사의 입사각을 설정할 때 참고 자료로 이용될 것으로 기대된다.

Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가 (The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View)

  • 고예원;주영철;김민석;고유림
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권3호
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

무릎뼈의 변형된 접선방향 검사 시 최적의 입사각에 관한 연구 (A Study on the Optimal Angle as Modified Tangential Projection of Knee Bones)

  • 오왕균;김상현
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.919-926
    • /
    • 2021
  • 본 연구는 무릎뼈의 변형된 접선 방향 검사 시 최적의 입사각에 대해 알아보고자 하였다. 실험은 Kyoto Kagaku사의 PBU-50 phantom을 이용하여 바로 누운 자세에서 넙다리뼈-정강뼈 각도(Femur-tibia angle, F-T angle)를 95°, 105°, 115°, 125°, 135°, 145°로 각각에서 X선 중심선과 정강뼈가 이루는 각도가 5~20° 되도록 5°씩 변경하여(62.5°, 67.5°, 72.5°, 77.5°, 82.5°, 87°, 87.5°) 무릎뼈 접선 방향 영상을 획득하였다. 영상분석을 위해 Image J를 이용하여 Congruence angle, Lateral patellofemoral angle, Patellofemoral index, 대조도 잡음비(Contrast to noise ratio, CNR)를 측정하였다. 통계 분석은 SPSS 22를 이용하여 일원배치분산분석과 대응표본 t-검정으로 Merchant method와 비교하였다. 연구 결과 Congruence angle의 경우 무릎 각도-X선 중심선의 입사각도가 105°-72.5°(20° 접선조사), 115°-72.5°, 77.5°(15, 20° 접선조사), 125°-82.5°(20° 접선조사), Lateral patellofemoral angle은 115°-72.5°, 77.5°(15, 20° 접선조사), 125°-72.5°(10° 접선조사), Patellofemoral index는 115°-72.5°(15° 접선조사), 125°-72.5°(10° 접선조사)에서 Merchant method와 유의한 차이가 없었다(p>.05). CNR의 경우 105°-67.5°, 72.5°(15, 20° 접선조사), 115°-67.5°, 72.5°, 77.5°(10, 15, 20°접선 조사)일 때 Merchant method와 차이가 없는 것으로 나타났다(p>.05). 본 연구의 결과를 통해 무릎뼈의 변형된 접선방향 검사 시 무릎 각도와 X선관의 입사각도를 각각 115°-72.5°(15° 접선 조사)로 설정함으로써 진단적 가치가 높은 영상을 획득할 수 있음을 확인하였다.

Graded 다층박막거울을 이용한 단색 엑스선 획득 (Acquisition of Monochromatic X-ray using Graded Multilayer Mirror)

  • 유철우;최병정;손현화;권영만;김병욱;김영주;천권수
    • 한국방사선학회논문지
    • /
    • 제9권4호
    • /
    • pp.205-211
    • /
    • 2015
  • 최근 의료영상기술에서 유방암 엑스선 진단기술의 주요 이슈는 정확한 조기암 진단과 환자의 피폭선량의 감소에 있다. 엑스선 영상대비도를 높이고 피폭선량을 줄이는 기술 중 하나로써 다층박막거울을 이용한 단색 엑스선을 획득하는 연구가 선행되어 왔다. 그러나 기존의 Uniform 다층박막거울은 거울면의 일부 반사영역에서만 원하는 파장대역의 단색 엑스선을 얻을 수 있어서 엑스선 영상기술 응용에 한계가 있다. 본 연구에서는 다층박막거울의 전 영역에 걸쳐 동일한 단색엑스선을 얻기 위해 거울에 입사하는 백색 엑스선의 입사각에 상응하는 선형적 기울기의 박막두께를 갖는 Graded 다층박막거울을 설계하였고, 기존 이온빔 스퍼터링 장치에 마스크 제어 장치를 추가 제작하여 $100{\times}100mm^2$ 크기로 제작하였다. 제작된 Graded 다층박막거울은 17.5keV의 단색 엑스선을 획득할 수 있도록 설계하였으며 박막두께주기는 2.88nm~4.62nm(Center 3.87nm)이다. 엑스선 반사율은 60% 이상이며, 단색 엑스선의 FWHM은 1.4keV 이하이고 엑스선 빔 폭은 3mm정도이다. 유방촬영에 적합한 몰리브덴 특성엑스선에 해당하는 17.5keV의 단색 엑스선을 얻음으로써 저선량 고감도 유방암 진단장치 개발에 응용할 수 있을 것으로 기대된다.