Inchworm-Like Robotic Colonoscope UsingLegs for Clamping (다리를 이용한 클램핑 방식의 자벌레 이동방식 대장내시경로봇)

  • Park, Hyun-Jun;Leem, Sang-Hyuck;Kim, Byung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.789-795
    • /
    • 2010
  • For the reliable clamping of a robotic colonoscope inside the colon, we propose a clamping module consisting of six legs at the front and a trigger at the rear. In addition, a pneumatic-line based locomotive mechanism, which was developed previously for in-pipe inspection, is adopted to reduce the friction force between the pneumatic lines and the locomotion environment. In order to evaluate locomotion performance, a robot with a diameter of 15 mm and a length of 110.250 mm is used. Based on control signal from LabVIEW, it is tested in acrylic pipe and pig's colon. The proposed robot is able to move in the curved path which has a radius of over 25 mm. The speed of the robot is 33 mm/s in a straight path and 12.1 mm/s on a vertical path. The proposed robot, which has one pneumatic line and two clamping modules, conclusively shows reliable locomotion performance under in vitro condition.

Precise Position Control of a Linear Stage with I/Q heterodyne Interferometer Feedback

  • Moon, Chan-Woo;Lee, Sung-Ho;Chung, J.K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1142-1146
    • /
    • 2004
  • The ultra precision linear stage is an essential device in the fields of MEMS and Bio technology. A piezo electric motor is widely used for its better linear characteristics, faster response time, and smaller size than conventional electro-magnetic actuator. We develop a new inchworm type motor to implement an actuator-integrated a long stroke linear stage which can move fast. To implement a servo system, we use a heterodyne interferometer as a position sensor, and we propose a new measurement technique using I/Q demodulator, and we propose a counting method to measure the position of fast moving object with low cost circuitry. The characteristics of the actuator and servo system are evaluated by measuring its displacement with a commercial laser interferometer.

  • PDF

Design and Control of 3DOF High Precision Positioning System With Double L Type Flexure Hinge Module

  • Kim, Ki-Beom;Jeon, Seung-Jin;Hwang, Dal-Yeon;Choi, Young-Jun;Park, Suk-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2524-2528
    • /
    • 2003
  • High-precision position system is widely used in lots of fields such as semiconductor industry, biotechnology, display and other up-to-date industry field. One of the main issues is to have a long traveling range with precision. There are a few solutions. For instance, there are inchworm methods, lever principle. In this study, we use lever principle to amplify output displacement with a new mechanical amplification structure. We designed new type 3DOF stage with PZT actuator and capacitive sensor. Non-monolithic structure is suggested to obtain the convenience of assembly and modification. Driving parts are designed as modules that generate displacement amplification of each axis. Designed motion module consists of 3 flexure hinges and a PZT actuator with double L lever structure.

  • PDF

Analysis for Movement Characteristics of Pneumatic Impulsive Actuator for Robotic Colonoscope (내시경용 로봇을 위한 공압구동기의 운동특성 해석)

  • Lee, Jin-Hui;Jeong, Yeon-Gu;Gang, Byeong-Gyu;Park, Jong-O
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1638-1644
    • /
    • 2002
  • A novel locomotion using the pneumatic impulsive actuator was proposed for robotic colonoscope. This locomotion showed good moving performance in the environment of rigid pipe, however, the displacement per one impact(step displacement) is greatly reduced due to the low stiffness and high damping characteristics of the colon. Therefore, the modeling technique based on spring and damping system is studied to predict the step displacement and some parametric studies are carried out to investigate main parameters that influence the step displacement of locomotion. Based on simulation result, a new locomotion to control the resistance force is suggested and fabricated. Through the experiment on the colon, the usefulness of modeling technique is confirmed and successful improvement of moving characteristics is achieved.

Research on the machinability in Micro Machining (초미세가공에서 절삭성 고찰)

  • 정종운;김재건;고태조;김희술;박종권
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.99-104
    • /
    • 2004
  • Micro/meso cutting is getting more important in the fields of precision machining technology. A micro-turning lathe is one of parts to consist the Micro Factory. It accepts stepwise motion actuators that are used for feeding system instead of the conventional mechanism. It is consisted of two Piezoelectric ceramics; one is for feeding the slider, and the other is for clamping the slider in the guide way of the body. The linearity and positional accuracy of the actuators are good enough for high precision motion. The spindle unit is operated with DC motor on the top of the slider. The motion is communicated with miniaturized linear encoder attached on each side of axis. A mono crystal diamond tool is used for cutting tool. This micro-lathe has been made a machining experiment to see the characteristics of micro-machining.

  • PDF

Improvement of circular cutting using adaptive control in micro milling with piezo-actuator (피에조 구동기의 마이크로 밀링에서 적응제어를 이용한 원주가공의 성능향상)

  • Chung B. M.;Ko T. J.;Seok J. W.;Kim H. S.;Park J. K.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.1 s.178
    • /
    • pp.201-208
    • /
    • 2006
  • Recently, there are many studies for the micro-machining using Piezo actuator. However, because of its step-by-step motion, it is nearly impossible to increase the machining accuracy for a circular path. To increase the accuracy, it is well known that it is necessary the finer and synchronous movement for x-y axes. Therefore, this paper proposes an adaptive control for finer movement of the actuator, and realizes a synchronous control for the x-y axes. The experimental results show that the machining accuracy is remarkably improved.

Magnetic Impact Actuator for Robotic Endoscope (대장내시경을 위한 자기 충격 액츄에이터)

  • 민현진;임형준;김병규;김수현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.839-843
    • /
    • 2001
  • For robotic endoscope, some researchers suggest pneumatic actuators based on inchworm motion. But, the existing endoscopes are not seemed to be replaced completely because human intestine is very sensitive and susceptible to damage. We design and test a new locomotion of robotic endoscope able to maneuver safely in the human intestine. The actuating mechanism is composed of two solenoids at each side and a single permanent magnet. When the current direction is reversed, repulsive force and attractive at the opposition side propels permanent magnet. Impact force against robotic endoscope transfer momentum from moving magnet to endoscope capsule. The direction and moving speed of the actuator can be controlled by adjusting impact force. Modeling and simulation experiments are carried out to predict the performance of the actuator. Simulation experiments show that force profile of permanent magnet is the dominant factor for the characteristic of the actuator. The results of simulations are verified by comparing with the experimental results.

  • PDF

Micro robot using actuators based on dielectric elastomer (고분자 구동기를 이용한 마이크로 로봇)

  • 최혁렬;정광목;남재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.334-337
    • /
    • 2003
  • In this paper. we introduce a novel actuation method based on dielectric elastomer. Along with basic principles of actuation using dielectric elastomer a new design of actuator is discussed. The proposed design has advantageous features in reduction in size, speed of response, ease and ruggedness of operation. Using the actuator. a three-degree-of-freedom actuator module is developed, which can provide up-down. and two rotational degree-of-freedom motion. In the application of the proposed actuation method, a micro-robot mimicking the motion of an inchworm is developed.

  • PDF

A Study on the Micro Machining Using Micro Machine (초소형 밀링머신을 이용한 미세절삭 가공)

  • 배영호;고태조;김희술;정병묵;김재건
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1203-1206
    • /
    • 2003
  • After the micro turning lathe was developed in the last year by AMR Laboratory, a micro-milling machine is developed for micro machining. This machine is integrated with PZT-driven micro-sliders, micro-linear encoders, air turbine spindle which has maximum 150.000 rpm. It is applicable to milling and drilling machining. This paper shows the possibility of micro machining and characteristics of micro end milling process by using micro machine. A machining of micro barrier ribs using 0.2 mm flat type end mill was achieved by micro-milling machine. As experimental results show the machining capability and positional accuracy of this machine is good enough for machining micro parts.

  • PDF

Development of a Rotating Device Using Piezoelectric and Micro Displacement System (압전소자와 미소변위 기구를 이용한 회전장치 개발)

  • 강시홍;엄태봉
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.494-497
    • /
    • 2003
  • A rotating device driven by an Inchworm motor was designed and fabricated to be used as an angie standard system. 1. PZT was adopted as a driving source, while the movement of PZT was guided by the leaf spring employing the elastic transformation of metals. 2. The device could rotate in a 360-degree arc. continuously Performance test of the device showed about 0.02 sec. of the minimum revolution angle and 1/15 rpm of the maimum revolution speed. 3. To improve its performance requires further studies on realizing a shifting device with faster response time, on increasing the output current (capacity) of the power amplifier used to drive PZT, on the dynamic motion of clamping. and on determining the optimum clamping condition

  • PDF