• Title/Summary/Keyword: in-position

Search Result 26,493, Processing Time 0.048 seconds

Relative Position Estimation using Kalman Filter Based on Inertial Sensor Signals Considering Soft Tissue Artifacts of Human Body Segments (신체 분절의 연조직 변형을 고려한 관성센서신호 기반의 상대위치 추정 칼만필터)

  • Lee, Chang June;Lee, Jung Keun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.237-242
    • /
    • 2020
  • This paper deals with relative position estimation using a Kalman filter (KF) based on inertial sensors that have been widely used in various biomechanics-related outdoor applications. In previous studies, the relative position is determined using relative orientation and predetermined segment-to-joint (S2J) vectors, which are assumed to be constant. However, because body segments are influenced by soft tissue artifacts (STAs), including the deformation and sliding of the skin over the underlying bone structures, they are not constant, resulting in significant errors during relative position estimation. In this study, relative position estimation was performed using a KF, where the S2J vectors were adopted as time-varying states. The joint constraint and the variations of the S2J vectors were used to develop a measurement model of the proposed KF. Accordingly, the covariance matrix corresponding to the variations of the S2J vectors continuously changed within the ranges of the STA-causing flexion angles. The experimental results of the knee flexion tests showed that the proposed KF decreased the estimation errors in the longitudinal and lateral directions by 8.86 and 17.89 mm, respectively, compared with a conventional approach based on the application of constant S2J vectors.

Orbital wall restoring surgery with primary orbital wall fragments in blowout fracture

  • Kang, Dong Hee
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.6
    • /
    • pp.347-353
    • /
    • 2019
  • Most orbital surgeons believe that it's difficult to restore the primary orbital wall to its previous position and that the orbital wall is so thin that cannot be firmly its primary position. Therefore, orbital wall fractures generally have been reconstructed by replacing the bony defect with a synthetic implant. Although synthetic implants have sufficient strength to maintain their shape and position in the orbital cavity, replacement surgery has some drawbacks due to the residual permanent implants. In previous studies, the author has reported an orbital wall restoring technique in which the primary orbital wall fragment was restored to its prior position through a combination of the transorbital and transantral approaches. Simple straight and curved elevators were introduced transnasally to restore the orbital wall and to maintain temporary extraorbital support in the maxillary and ethmoid sinus. A transconjunctival approach provided sufficient space for implant insertion, while the transnasal approach enabled restoration of the herniated soft tissue back into the orbit. Fracture defect was reduced by restoring the primary orbital wall fragment to its primary position, making it possible to use relatively small size implant, furthermore, extraorbital support from both sinuses decreased the incidence of implant displacement. The author could recreate a natural shape of the orbit with the patient's own orbital bone fragments with this dual approach and effectively restored the orbital volume and shape. This procedure has the advantages for retrieving the orbital contents and restoring the primary orbital wall to its prior position.

Pulse Counting Sensorless Detection of the Shaft Speed and Position of DC Motor Based Electromechanical Actuators

  • Testa, Antonio;De Caro, Salvatore;Scimone, Tommaso;Letor, Romeo
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.957-966
    • /
    • 2014
  • Some of DC actuators used in home automation, office automation, medical equipment and automotive systems require a position sensor. In low power applications, the introduction of such a transducer remarkably increases the whole system cost, which justifies the development of sensorless position estimation techniques. The well-known AC motor drive sensorless techniques exploiting the fundamental component of the back electromotive force cannot be used on DC motor drives. In addition, the sophisticated approaches based on current or voltage signal injection cannot be used. Therefore, an effective and inexpensive sensorless position estimation technique suitable for DC motors is presented in this paper. This technique exploits the periodic pulses of the armature current caused by commutation. It is based on a simple pulse counting algorithm, suitable for coping with the rather large variability of the pulse frequency and it leads to the realization of a sensorless position control system for low cost, medium performance systems, like those in the field of automotive applications.

The Study on Three-portion and Nine-position Pulse Taking Diagnosis (삼부구후진단(三部九候診斷)에 대한 고찰(考察);"내경"과 "난경"을 중심으로)

  • Eom, Dong-Myung
    • Journal of Korean Medical classics
    • /
    • v.20 no.3
    • /
    • pp.57-65
    • /
    • 2007
  • This present study tried to observe an each feature that the difference of Neijing(內經) and Nanjing(難經) descriptions about the three-portion and nine-position pulse taking(三部九候脈). It was interpreted and contradistinguished that discrimination of position, diagnosis object, and the perceptions of Earth of the center among the Five Phase of each literature were described in Neijing and Nanjing for the three-portion and nine-position(三部九候). In Neijing, the three-portion and nine-position method divided three parts the whole body. Then the each three parts again divided with Heaven, Earth and Man(天地人). About the corresponding parts of pulse diagnosis, there mentioned for the head and the Zang-Fu organs(臟腑), but not mentioned for the hand and foot. In addition, Earth is assigned to the Earth(土), an each Earth accounted for the source of life. In Nanjing, three-portion divided Chon, Gwan, and Cheok(寸關尺) and each spots separated three stage of pulse taking. For the pulse taking spots and diagnosis, there mentioned the hand and foot instead of the unclear mention of Zang-Fu organs. Then Gwan spot and middle stage of pulse taking were assigned to the Earth, respectively. It was emphasized stomach Qi(胃氣) that the region of Earth, Gwan spot and middle stage among the pulse taking spots each literature were described in Neijing, Nanjing.

  • PDF

Internal Lecturer Management Plan for Effective Information Security Technology Job Training (효과적인 정보보호 기술 직무교육을 위한 사내강사 운영관리 방안)

  • Yang, Jinseok;Chung, Taimyoung;Eom, Jungho
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.4
    • /
    • pp.109-116
    • /
    • 2018
  • This research proposed management plan of internal lecturer who is in charge of job training of researchers working in administrative, researching and developing institutes or public institutions related to information security. The education and training department of the government or public institutions selects and manages lecturers in member of the staff. We applied to the management plan of internal lecturers who are in charge of information security job training by analyzing the way in which internal lecturers are operated by public organizations or corporations. We propose the management plan of internal lecturer according to the position, because the institute of information security is applying the researcher 's position(rank) system. By the proposed circulation management plan by the position, the internal lecturer position is determined according to the position of the employees to be trained and the internal lecturer is selected and operated only at the same position. The proposed management plan includes internal lecturer selection, responsibilities and duties, education, evaluation, and training support.

Optimization of Joint Hole Position Design for Composite Beam Clamping (복합재 빔 체결을 위한 체결 홀 위치 최적화)

  • Cho, Hee-Keun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.2
    • /
    • pp.14-21
    • /
    • 2019
  • In recent years, the use of composite structures has become commonplace in various fields such as aerospace, architecture, and civil engineering. In this study, A method is proposed to find optimal position of bolt hole for fastening of composite structure. In the case of composites, stress distribution is very complicated, and design optimization based on this phenomenon increases difficulty. In selecting the optimum position of the bolt hole, the response surface method(rsm), which is a method of optimization, was applied. A response surface was created based on design points by multiple finite element analyzes. The position of the bolt hole that minimizes the stress when bolting on the response surface was found. The distribution of the stress at the position of the optimal hole was much lower than that of the initial design. Based on the results of this study, it is possible to increase the design safety factor of the structure by appropriately selecting the position of the bolt hole according to various load types when designing the structure and civil structure.

Effects of Semi-Squat Exercise on Joint Position Sense and Balance to the Types of Support Surface in Hemiplegic Patients

  • Oh, Juyeong;Kim, Joong Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.5
    • /
    • pp.242-247
    • /
    • 2022
  • Purpose: This study investigates the effect of 60° semi-squat exercises according to three different types of support surfaces. The effects were examined on joint position sense and balancing ability using stable and unstable surfaces in patients afflicted with post-stroke hemiplegia. Methods: Subjects were instructed to perform three sets of 60° semi-squat exercises according to the characteristics of the support surface conditions. The three ground states were bilateral stable surface (BSS), nonaffected side unstable surface (NUS), and bilateral unstable surface (BUS). The joint position sense, characteristics of body sway, and dynamic balance were analyzed according to floor conditions before and after the experiment. A balance-pad (50 cm W×41 cm L×6 cm H; Alcan Airex AG, Sins, Switzerland) was used for the unstable floor. Results: The 60° semi-squat exercises applied to hemiplegic patients showed the highest statistical significance in joint position sense in the NUS group, and Timed Up and Go test (TUG) in the BUS group (p<0.05). Conclusion: Functional training using an unstable surface can be applied as a meaningful intervention method for improving the balance and joint position sense of stroke patients.

Discrepancies in Soft Tissue Profile of Patients for Orthognathic Surgery between Preoperative Lateral Facial Photograph, Lateral Cephalogram and Supine Position on Operation Table

  • Jung, Young-Eun;Yang, Hoon-Joo;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.3
    • /
    • pp.180-185
    • /
    • 2012
  • Purpose: An accurate preoperative analysis of the patient is essential in orthognathic surgery in order to acquire superior results. In profile, the location of the chin's position may change according to the neck's inclination. This may ultimately affect the amount of surgical movement. During acquisition of cephalometric radiographs, or in supine position, there is a discrepancy in the neck's inclination. This means that there are also various discrepancies between the actual profile and the various preoperative profile images. In the clinical situation, the decision in performing genioplasty usually lies in the analysis of the patient's profile on the operating table at the final stages of orthognathic surgery. This study aims to analyze the different preoperative profile images and to compare their discrepancies. Methods: Fifty eight patients undergoing orthognathic surgery were chosen. These patients were divided into three groups according to angle's classification of malocclusion, as class I, II or III. The right profile of these patients in centric occlusion was taken in natural head position (NHP). This was set as the 'actual profile image.' Another right profile image was taken on the operating table after insertion of the nasotracheal intubation and with muscle relaxants in effect. This was also taken in centric occlusion. The angle (denoted 'A') between the soft tissue glabella-pognion and the true vertical plane was found in the above-mentioned profile images and in the cephalometric radiographs. The differences of these values were analyzed. Results: There were differences in Angle 'A' in all of the preoperative images. These values were however, not statistically significant. Conclusion: In order to gain an esthetic profile during orthognathic surgery, the NHP is shown to be the most reliable position. Images reproducing such head positions should be used in the treatment planning process.

Effect of Patient's Positioning on the Grade of Tendinosis and Visible Range of Infraspinatus Tendon on Ultrasound (초음파 영상에서 극하근 힘줄병의 단계와 관찰가능 범위에 환자의 자세가 미치는 영향)

  • Jee Won Chai;Joo-ho Lee;Dong Hyun Kim;Jina Park;So-Hee Oh;Su-Mi Shin
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.627-637
    • /
    • 2023
  • Purpose To investigate the effect of patient positioning on tendinosis grade, visible range, and infraspinatus tendon (IST) thickness, and to determine the feasibility of internal rotation (IR) position to assess IST on ultrasound (US). Materials and Methods This study included 52 shoulders of 48 subjects who were evaluated for IST in three different positions: neutral position (N), IR, and position with the ipsilateral hand on the contralateral shoulder (HC). Two radiologists retrospectively graded IST tendinosis from grade 0 to grade 3 and the visible range from grade 1 to grade 4. The thickness of the IST was measured by another radiologist with a short-axis view. A generalized estimating equation was used for statistical analysis. Results The tendinosis grades were higher in the HC position than in the IR position, with a cumulative odds ratio of 2.087 (p = 0.004, 95% confidence interval [CI]: 1.268-3.433). The tendinosis grades in the HC position (p = 0.370) and IR position (p = 0.146) were not significantly different from those in the N position. The overall difference in IST thickness was significant (p < 0.001), but the visible range (p = 0.530) was not significantly different according to position. Conclusion Patient positioning significantly affected the grade of tendinosis and thickness but not the visible range of the IST. The IR position is a feasible position for assessing the IST on US.

Control-performance Improvement of Dual EHAs (이중 EHA의 제어 특성 개선)

  • Lee, Seong Ryeol;Hong, Yeh Sun
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.32-38
    • /
    • 2016
  • For this paper, the position-control performances of dual EHA(electro-hydrostatic actuator) systems were investigated according to two cases wherein the double-rod- and single-rod-type hydraulic cylinders were combined. Since the control performance is significantly dependent on the load conditions including external forces such as the inertia load, it is proposed here that the two sub-EHAs are driven by separate position and force controllers, instead of two identical position controllers. According to the simulation results, the best performance was achieved by the position-controlled single-rod-type EHA that was combined with a force-controlled double-rod-type EHA. As the force-controlled double-rod-type EHA compensated for the external loads on the position-controlled single-rod-type EHA, the position-control performance was not influenced by external forces including the inertia load. In addition, the position-controlled single-rod-type EHA contributed to the enhancement of the damping ratio by absorbing the pressure peaks through its internal accumulator. Due to the symmetrical piston areas, the double-rod-type EHA is more suitable for force control than the single-rod- type EHA.