• Title/Summary/Keyword: in-place tests

Search Result 387, Processing Time 0.028 seconds

Geological Characteristics of a Wetland in Mt. Geumjeong (금정산 산지습지의 지질학적 특성)

  • Cha, Eun-Jee;Hamm, Se-Yeong;Kim, Hyun-Ji;Lee, Jeong-Hwan;Cheong, Jae-Yeol;Ok, Soon-Il
    • Journal of Wetlands Research
    • /
    • v.12 no.2
    • /
    • pp.1-12
    • /
    • 2010
  • This study examined geological characteristics of a wetland in Mountain Geumjeong in Busan Metropolitan City. Field survey and laboratory tests were performed to identify topographic features, geological and structural geological characteristics, rock strength along the distance from the wetland, soil profile in the wetland, and chemical property of the wetland soil. The bedrock of the wetland consists of hornblende granite. Hornblende granite and rhyolitic rock around the wetland have the joints with strikes of N-S, E-W, and NE-SW directions and with higher dips greater than $60^{\circ}$. Lower rock strength and higher weathering grades take place towards the wetlands. According to X-ray diffraction analysis of wetland soil samples, kaolinite, montmorillonite, and gibbsite appear which demonstrate weathered products of feldspars in the hornblende granite. The soil profile in the wetland comprises O, A, B, and C horizons from the land surface. The contents of the organic matters decrease from shallow parts to deeper parts of the soil profile. In addition, $K^+$ and $Na^+$ originating from the weathering of feldspars are dominant components among inorganic ions in the wetland soil.

CATHARE simulation results of the natural circulation characterisation test of the PKL test facility

  • Salah, Anis Bousbia
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1446-1453
    • /
    • 2021
  • In the past, several experimental investigations aiming at characterizing the natural circulation (NC) behavior in test facilities were carried out. They showed a variety of flow patterns characterized by an inverted U-shape of the NC flow curve versus primary mass inventory. On the other hand, attempts to reproduce such curves using thermal-hydraulic system codes, showed 10-30% differences between the measured and calculated NC mass flow rate. Actually, the used computer codes are generally based upon nodalization using single U-tube representation. Such model may not allow getting accurate simulation of most of the NC phenomena occurring during such tests (like flow redistribution and flow reversal in some SG U-tubes). Simulations based on multi-U-tubes model, showed better agreement with the overall behavior, but remain unable to predict NC phenomena taking place in the steam generator (SG) during the experiment. In the current study, the CATHARE code is considered in order to assess a NC characterization test performed in the four loops PKL facility. For this purpose, four different SG nodalizations including, single and multi-U-tubes, 1D and 3D SG inlet/outlet zones are considered. In general, it is shown that the 1D and 3D models exhibit similar prediction results up to a certain point of the rising part of the inverted U-shape of the NC flow curve. After that, the results bifurcate with, on the one hand, a tendency of the 1D models to over-predict the measured NC mass flow rate and on the other hand, a tendency of the 3D models to under-predict the NC flow rate.

Chemical Resistance and Field Trial of 3D-Printed Plastic Ball Bearing Used in Electric Motors for Chemical Processes (화학공정용 전동기에 사용된 3D 프린팅 플라스틱 볼베어링의 내화학성 평가 및 현장적용 연구)

  • Youngjun Kwon;Myounggyu Noh
    • Tribology and Lubricants
    • /
    • v.39 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • Fluid pumps in chemical processes are typically driven by electric motors. Even if the motor is separated from the pump with seals, wear resulting from friction and misalignment can lead to leakage of chemical fluid, causing corrosion in the bearing supporting the motor, and, eventually, failure of the motor. It is thus a standard procedure to replace bearings at regular intervals. In this article, we propose 3D-printed plastic ball bearings for use as an alternative to commercial stainless-steel ball bearings. The plastic bearings are easy to manufacture, require less time to replace, and are chemically resistant. To validate the applicability of the plastic bearings, we first conducted chemical resistance tests. Bearings were immersed in 30 caustic acid and 30 nitric acid for 30 min and 24 h, respectively. The test results showed no corrosive damage to the bearings. A test rig was set up to compare the performance of the plastic bearings with that of the commercially equivalent deep-groove ball bearings. Loading test results showed that the plastic bearings performed as well as the commercial bearing in terms of vibration level and load-handling capability. Finally, a plastic bearing was subjected to a clean-in-place process for three months. It actually outperformed the commercial bearing in terms of chemical resistance. Thus, 3D-printed plastic bearings are a viable alternative to stainless-steel ball bearings.

The effects of gingival blood flow on pulpal blood flow detection using ultrasound Doppler flowmetry: animal study

  • Dohyun Kim ;Hyoung-Seok Ko;Soo-Yeon Park ;Seung-Yeon Ryu ;Sung-ho Park
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.9.1-9.11
    • /
    • 2023
  • Objectives: This study evaluated the effect of adjacent gingival blood flow on detection of pulpal blood flow (PBF) using ultrasound Doppler flowmetry (UDF) through animal study. Materials and Methods: The study included 36 right and left maxillary the third incisors and canines in 9 experimental dogs. The study included 2 main steps: In the first step, the pulse sound level (PSL) was recorded on the cervical part of each tooth without flap elevation (Group 1), with flap elevation (Group 2), and after it was repositioned in place (Group 3). In the second step, the PSL was recorded on the cervical part of each tooth (Group 4), after pulpotomy (Group 5), after partial pulp extirpation (Group 6), after complete extirpation (Group 7), and after canal filling (Group 8). In Groups 5-8, the study was performed with and without flap elevation in the left and right teeth, respectively. The PSL was graded as follows: 0, inaudible; 1, heard faintly; and 2, heard well. The difference between each group was analyzed using Friedman's test with Wilcoxon signed-rank tests (α = 0.05). Results: In step 1, the PSL results were Group 1 > 2 and 3. In step 2, there was no significant difference between the groups when the flap was not elevated, while PSL results were Group 4 > 5 ≥ 6 and 7 ≥ 8 when the flap was elevated. Conclusions: PBF is affected by gingival blood flow when measured with UDF. UDF measurements require isolation of gingiva from the tooth.

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust and Wind Velocity (분진 및 풍속에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Chun-Ha;Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • The present article discusses the response characteristics of smoke detector chamber due to dust and wind velocity. Although situations have improved in terms of early sensing of fires as the smoke detectors are applied indoors, studies tend to place insufficient focus on the side effects and malfunction that can be caused by diversified life dust produced indoors and environmental requirements, etc. Therefore, in the present study, 4 types of photoelectric smoke detectors with different forms and structures of smoke chamber were selected as the experimental objects, and dust test was conducted with fly ash, talcum powder and fiber dust as experiment samples to study indoor applicability of the smoke detectors in terms of their response to diversified dust and wind velocity. Also, to observe response characteristics due to pollution level inside the smoke chamber, wind velocity for dust test were set additionally at 0.25 m/s, 0.5 m/s, and 1.0 m/s. Based to the experimental results, fly ash, talcum powder, and fiber dust (black hair powder) were found to be suitable at the dust test reference wind velocity conditions of 0.25 m/s for both operation test and non-operation test after dust application. On the other hand, under the harsh wind velocity conditions of 0.5 m/s and 1.0 m/s, malfunction of unwanted alarm was observed in non-operation tests in the case of fly ash and talcum powder, and non-operation was confirmed to occur in the case of fiber dust as the alarm failed to operate normally in operation tests.

The Comparative Study of Effect on Speech before and after Orthognathic Surgery of Patients (악교정 환자의 악교정 수술전후 발음양상에 대한 비교연구)

  • Kwon, Kyung-Hwan;Kim, Soo-Nam;Lee, Dong-Keun;Cho, Yong-Min;Lee, Suk-Hyang
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.2
    • /
    • pp.191-205
    • /
    • 2000
  • The purpose of this study was undertaken to determine the effects of orthognathic surgery on speech. The hyposis stated herein is that functional behaviors of the dentofacial complex, such as speech production, may be adversely affected by deviations of a structural nature(especially, Class III malocclusion). Twenty adults with Class III malocclusion(13 female and 7 male) were studied preoperative, immediate postoperative and either 6 or 12 months postoperative lateral cephalograms. They had mandibular prognathism and had undergone mandible setback operation. The position of tongue, soft palate(Uvula), hyoid bone, respiratory track width, and pharyngeal depth were assessed on lateral cephalograms with 23 cephalometric variables, ANOVA, Paired t-tests and Pearson's product-moment correlation coefficient tests were used to evalute the operative changes in all cephalometric parameters. A experienced speech and language pathologists performed narrow phonetic transcriptions of tape-recorded words and sentences produced by each of the ninth patients and the recording tapes were analyzed by phonetic computer program(Computerized Speech Lab(CSL) Model 4300BI(U.S.A.)) These judges also recorded their ratings of each patient's overall consonants, hypernasality, hyponasality, and articulation proficiency. The results obtained are as follows; 1. There were significant changes in distance of posterior pharyngeal wall to tongue (TI-TW2, TS-TW3) after the surgery at 6 months postoperatively(each p<0.01 p<0.05). 2. The posterior tongue point(TI, TS, PPT) moved posteriorly after surgery and remained to its changed position at 6 months postoperatively(p<0.05). The displacement of tongue was correlated with the movement of mandibular setback amount(p<0.05). The hyoid bone moved posteriorly superiorly after immediate postoperative period. There was significant changes in hyoid bone movement after immediated postoperative period(p<0.05), but returned to its original position during the follow-up period(p>0.05) 3. The soft palate was displaced posteriorly superiorly after immediated operative period and remained to its changed position at 6 months postoperatively(p<0.05). ANS-PNS-SPT angle increasing, PPU-PPPo distance narrowing was showed after surgery, and remained its appearance 6 months postoperatively(p<0.05). 4. There were significant changes in formant value and squre diagram of vowel sound after the orthognathic surgery and the follow-up period. There were significant changes in /ㅅ/sound and posterior tongue sound. 5. The posterior movement of tongue and the posteriosuperior movement of soft palate was correlated with mandibular setback amount after orthognathic surgery. On the vowel squre diagram, the author found that the place of articulation after operation moved downward, backward, upward. 6. In assessing speech abnormalities, dental occlusion should be considered as a contributing factor. The vast majority of subjects with preoperative misarticulations eliminated or reduced their errors following orthognathic surgery. There was significant difference in speech impovement between pre- and postoperation.

  • PDF

Evaluation on Immunogenicity and Safety of Avian Influenza Isolate(ADL0401) as a Candidate for the Killed Vaccine against tow-Pathogenic Avian Influenza (약병원성 조류인플루엔자 사독백신개발을 위한 후보주(ADL0401)의 면역 원성 및 안전성 평가)

  • Lee J. S.;Ha D. H.;Kim J. E.;Ha B. D.;Mo I. P.
    • Korean Journal of Poultry Science
    • /
    • v.32 no.2
    • /
    • pp.113-123
    • /
    • 2005
  • Avian influenza (AI) virus (AIV) is distributed worldwide and it has been isolated from various species of wild and domestic birds. AI transfers with high speed and shows diverse pathogenicity syndroms. In Korea, several low Pathogenic AIV, H9N2, have been isolated from the commercial farms with severe decrease of egg production and mortality resulted in severe economic loss since 1996. Therefore, it has been requested to develop AI vaccines to prevent clinical signs and economic losses from the field infection of AIV. To develop a killed vaccine that efficiently prevents low pathogenic AIV (H9N2), evaluation on the pathogenicity and selection of an inactivator for H9N2 is taking place and is being tested safety and immunogenicity of vaccine produced. Based on the pathogenicity test and viral reisolation test, the ADL0401 isolate is the characteristic low pathogenic AIVs and has fairly similar biologic functions compared with MS96 which is the official low pathogenic AIV (H9N2) and one of the predominant AIV isolated from poultry farms in Korea. In antigenicity tests, the ADL0401 and MS96 virus have no significant antigenic difference. In inactivation tests, the ADL0401 isolates can be easily inactivated with $0.1\%$ Formalin at $37^{\circ}C$ within 1 hour with a little decrease of HA titer. The vaccine developed in the present report has no harmful effect on bird and forms good immune capability. Therefore, the isolates, ADL0401 can be used for a killed vaccine which can reduce the clinical signs and viral shedding in the birds infected with H9N2 low pathogenic AIVs.

Analysis of Solute Transport based on Electrical Resistance Measurements from Laboratory Column Tests (전기저항센서가 부착된 주상실험기에서 측정된 전기저항값을 이용한 용질의 이동해석)

  • Kim, Yong-Sung;Kim, Jae-Jin;Park, Junboum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4C
    • /
    • pp.231-238
    • /
    • 2008
  • A column testing device capable of measuring the electrical resistivity of soil at 3 different locations was developed to verify applicability of bulk electrical conductivity (BEC) breakthrough curves in monitoring contaminant transport. Tracer injection tests were conducted with three different types of saturated sands to obtain average linear velocities and longitudinal hydrodynamic dispersion coefficients based on BEC breakthrough curves and effluent solute breakthrough curves. Comparative analysis of transport parameters obtained from curve fitting the results into the analytical solutions confirmed the validity of resistance measurements in estimating time-continuous resident solute concentration. Under the assumption that a linear relationship exists between ${\sigma}_{sat}-{\sigma}_w-C$, the BEC breakthrough curves are able to effectively reduce the laborious and time-consuming processes involved in the conventional method of sampling and analysis. In order to reduce possible uncertainties in analyzing the BEC breakthrough curves, it was recommended that resistance measurements take place nearby the effluent boundary. In addition, a sufficient electrical contrast or difference in the electrical conductivity of the influent and the saturating solution is required to conduct reliable analysis.

The Moderating Effects of Band Circuit Training for the Mortality Improvement of Elderly Women (노인여성의 사망률 개선을 위한 밴드 서킷 트레이닝의 중재 효과)

  • Lee, Hyang-Beum
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.6
    • /
    • pp.165-173
    • /
    • 2019
  • This study aims to examine the moderating effects of band circuit training for the mortality improvement of elderly women to provide an effective exercise moderating program for the enhanced quality of life of the elderly. To achieve the purpose of this study, the moderating effects of 8 weeks of band circuit training in the Senior Fitness Tests (SFT) and Sitting Rising Tests (SRT) of elderly women ages 65 and older in Y city were examined and the following results were gained. The functional fitness of elderly women according to the moderating effects of band circuit training (sitting down in a chair and standing up, lifting 2 kg dumbbells, walking in place for 2 minutes, sitting in a chair and bending forward, hand holding behind one's back, walking back and forth for 2.44 m) and the Sitting Rising Test (SRT) displayed statistically significant interaction effects among measurement times and groups and positive improvements were shown in the test group after band circuit training moderation. These research results show that band circuit training moderation has a positive effect on functional fitness and SRT, which are associated with the mortality rate of the elderly, and thus it can be applied as an effective exercise moderation program for the improvement of quality of life through the mortality improvement of the elderly.

Is Transradial Cerebral Angiography Feasible and Safe? A Single Center's Experience

  • Jo, Kwang-Wook;Park, Sung-Man;Kim, Sang-Don;Kim, Seong-Rim;Baik, Min-Woo;Kim, Young-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.332-337
    • /
    • 2010
  • Objective : Although a transradial angiography is accepted as the gold standard for cardiovascular procedures, cerebral angiography has been performed via transfemoral approach in most institutions. The purpose of this study is to present our experience concerning the feasibility, efficacy, and safety of a transradial approach to cerebral angiography as an alternative to a transfemoral approach. Methods : Between February 2007 and October 2009, a total of 1,240 cerebral angiographies were performed via a transradial approach in a single center. The right radial approach was used as an initial access route. The procedure continued only after the ulnar artery was proven to provide satisfactory collateral perfusion according to two tests (a modified Allen's test and forearm angiography). Results : The procedural success rate was 94.8% with a mean duration of 28 minutes. All supra-aortic vessels were successfully catheterized with a success rate of 100%. The success rates of selective catheterization to the right vertebral artery, right internal carotid artery, left internal carotid artery, and left vertebral artery were 96.1%, 98.6%, 82.6% and 52.2%, respectively. The procedure was performed more than twice in 73 patients (5.9%), including up to 4 times in 2 patients. The radial artery occlusion was found in 4 patients (5.4%) on follow-up cerebral angiography, but no ischemic symptoms were observed in any of the cases. Conclusion : This study suggests that cerebral angiography using a transradial approach can be performed with minimal risk of morbidity. In particular, this procedure might be useful for follow-up angiographies and place less stress on patients.