• Title/Summary/Keyword: in vivo imaging

Search Result 387, Processing Time 0.025 seconds

A Noise Reduction Technique for Enhancing Pituitary Adenoma Diagnostic on Magnetic Resonance Image (개선된 뇌하수체 선종 진단을 위한 자기공명영상 노이즈 제거 기법)

  • Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.285-290
    • /
    • 2019
  • Magnetic resonance imaging is a technique specialized in soft tissue imaging with high contrast resolution without in vivo ionization and has been widely used in various clinical settings. In particular, the recent increase in social stress factors has been used in the diagnosis of pituitary adenoma, the incidence increases rapidly. Recently, due to the development of magnetic resonance imaging, it is possible to diagnose micro pituitary adenoma, but despite the use of contrast medium, there has been a difficulty in diagnosing the pituitary adenoma due to its small size and noise. In order to solve this problem, a proposed method of separating signal components image and noise components image from a measured image is applied, and the improvement of diagnostic efficiency is attempted by removing noise. As a result, it was confirmed that the image quality was improved as a whole by applying SNR for 30 subjects data. It is expected that this study will be useful as a pre-processing method for improving the image quality and developing diagnostic indicators of pituitary adenoma.

Performance prediction of gamma electron vertex imaging (GEVI) system for interfractional range shift detection in spot scanning proton therapy

  • Kim, Sung Hun;Jeong, Jong Hwi;Ku, Youngmo;Jung, Jaerin;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2213-2220
    • /
    • 2022
  • The maximum dose delivery at the end of the beam range provides the main advantage of using proton therapy. The range of the proton beam, however, is subject to uncertainties, which limit the clinical benefits of proton therapy and, therefore, accurate in vivo verification of the beam range is desirable. For the beam range verification in spot scanning proton therapy, a prompt gamma detection system, called as gamma electron vertex imaging (GEVI) system, is under development and, in the present study, the performance of the GEVI system in spot scanning proton therapy was predicted with Geant4 Monte Carlo simulations in terms of shift detection sensitivity, accuracy and precision. The simulation results indicated that the GEVI system can detect the interfractional range shifts down to 1 mm shift for the cases considered in the present study. The results also showed that both the evaluated accuracy and precision were less than 1-2 mm, except for the scenarios where we consider all spots in the energy layer for a local shifting. It was very encouraging results that the accuracy and precision satisfied the smallest distal safety margin of the investigated beam energy (i.e., 4.88 mm for 134.9 MeV).

In-Vivo Heat Transfer Measurement using Proton Resonance Frequency Method of Magnetic Resonance Imaging (자기 공명영상 시스템의 수소원자 공명 주파수법을 이용한 생체 내 열 전달 관찰)

  • 조지연;조종운;이현용;신운재;은충기;문치웅
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.172-180
    • /
    • 2003
  • The purpose of this study is to observe the heat transfer process in in-vivo human muscle based on Proton Resonance Frequency(PRF) method in Magnetic Resonance Imaging(MRI). MRI was obtained to measure the temperature variation according to the heat transfer in phantom and in-vivo human calf muscle. A phantom(2% agarose gel) was used in this experiment. MR temperature measurement was compared with the direct temperature measurement using a T-type thermocouple. After heating agarose gel to more than 5$0^{\circ}C$ in boiling hot water, raw data were acquired every 3 minutes during one hour cooling period for a phantom case. For human study heat was forced to deliver into volunteer's calf muscle using hot pack. Reference data were once acquired before a hot pack emits heat and raw data were acquired every 2 minutes during 30minutes. Acquired raw data were reconstructed to phase-difference images with reference image to observe the temperature change. Phase-difference of the phantom was linearly proportional to the temperature change in the range of 34.2$^{\circ}C$ and 50.2$^{\circ}C$. Temperature resolution was 0.0457 radian /$^{\circ}C$(0.0038 ppm/$^{\circ}C$) in phantom case. In vivo-case, mean phase-difference in near region from the hot pack is smaller than that in far region. Different temperature distribution was observed in proportion to a distance from heat source.

Medial Longitudinal Fasciculus on MRI in a Patient with Internuclear Ophthalmoparesis: A Case Report (신경핵사이 눈근육마비환자에서 자기공명영상에서의 내측세로다발: 증례 보고)

  • Kim, Sung Min;Kim, Ho Kyun;Lee, Hui Joong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.167-170
    • /
    • 2014
  • The medial longitudinal fasciculus (MLF) is myelinated composite tract, lying near the midline, ventral to periaqueductal grey matter that plays a key role in coordinating eye movements. A lesion of the MLF results in an ipsilateral adduction deficit and a contralateral abducting nystagmus, referred to as an internuclear ophthalmoparesis. The blended tract with adjacent white matter in pons and midbrain is indistinguishable on brain imaging such as CT and MRI. Until now, to the best of our knowledge, MLF is not delineated on in vivo MRI. We present a case showing the whole connecting courses of MLF lesion on MRI in a patient with inflammatory demyelinating disorder.

Characterization of PEG-conjugated AuNPs by Using ToF-SIMS Imaging, Spectroscopic and Statistical Techniques

  • Shon, Hyun-Kyong;Son, Mi-Yong;Park, Hyun-Min;Moon, Dae-Won;Song, Nam-Woong;Lee, Tae-Geol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.73-73
    • /
    • 2010
  • Various organic- and bio-conjugated nanoparticles have been studied extensively for biological applications in medical diagnoses and drug delivery systems. Gold nanoparticles (AuNP) and poly(ethylene glycol) (PEG) are known biocompatible materials to be used in vivo and are becoming increasingly important in biomedical applications. In this work, we investigated the stability of PEG-conjugated AuNPs, dialysis and centrifuge effects after synthesis or pegylation of AuNPs as a function of elapsed time by using ToF-SIMS imaging technique along with dynamic light scattering (DLS), UV-visible absorption spectroscopic and statistical analyses. Roughly 15-nm-sized AuNPs were synthesized in a citrate-conjugated form, and then converted into the thiol-terminated PEG (O-[2-(3-Mercaptopropionylamino)ethyl]-O'-methylpolyethyleneglycol, M.W.=5 kDa) form. Based on our data, we will show that ToF-SIMS imaging analysis along with DLS, UV-visible absorption and statistical analyses would be a useful method to evaluate stability of PEG-conjugated AuNPs in various environmental conditions.

  • PDF

PREPARATION OF N-(3-BROMO-2,4,6-TRIMETHYLACETANILIDE)IMINODIACETIC ACID AND ITS ${99M}^TC$-COMPLEX FOR HEPATOBILIARY IMAGING

  • CHOI OK-JA;HONG YOUNG-DON;GWON HUI-JEONG;CHOI SANG-MU;CHOI SUN-JU
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.391-394
    • /
    • 2005
  • N-(3-bromo-2,4,6-trimethylacetanilide)iminodiacetic acid (BrTIDA) was synthesized using nitrilotriacetic anhydride prepared in situ, and lyophilized vials were prepared which contained 20 mg of BrTIDA and 0.4 mg of $SnCl_2$. To evaluate the clinical efficacy of the in-house prepared lyophilized kit, a technetium-99m complex of BrTIDA was prepared; its in vivo pharmacokinetic behavior was evaluated via animal studies to assess the hepatocytic function and the functional status of the cystic duct and the gallbladder. Serial static image scans of rabbits and the biodistribution in mice injected with $^{99m}Tc-BrTIDA$ revealed that none of the tissues except for the hepatobiliary system showed radioactivity concentrations, and a rapid clearance from the organs was observed. In conclusion, a lyophilized kit and its prepared $^{99m}Tc-BrTIDA$ can be applied as a hepatobiliary imaging agent for the evaluation of the functional status of the hepatocytes and the patency of the biliary duct.

Complex Conjugate Resolved Retinal Imaging by One-micrometer Spectral Domain Optical Coherence Tomography Using an Electro-optical Phase Modulator

  • Fabritius, Tapio E.J.;Makita, Shuichi;Yamanari, Masahiro;Myllyla, Risto A.;Yasuno, Yoshiaki
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Full-range spectral domain optical coherence tomography (SD-OCT) with a 1-${\mu}m$ band light source is shown here. The phase of the reference beam is continuously stepped while the probing beam scans the sample laterally (B-scan). The two dimensional spectral interferogram obtained is processed by a Fourier transform method to obtain a complex spectrum leading to a full-range OCT image. A detailed mathematical explanation of the complex conjugate resolving method utilized is provided. The system's measurement speed was 7.96 kHz, the measured axial resolution was $9.6{\mu}m$ in air and the maximum sensitivity 99.4 dB. To demonstrate the effect of mirror image elimination, In vivo human eye pathology was measured.

Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement (경식도 심초음파 검사를 이용한 판막대치술 환자의 평가)

  • 조건현
    • Journal of Chest Surgery
    • /
    • v.24 no.3
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF

Algorithm to Shorten Imaging Time in Fluorescent X-ray Computed Tomogrpahy (형광 X선 CT에서 촬상 시간의 단축화 알고리즘)

  • 정남채
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.4
    • /
    • pp.46-52
    • /
    • 2001
  • In this paper it was examined both imaging system and processing algorithm for imaging's high speedization of fluorescent X-ray computed tomography using synchrotron radiation, The electronic system was used for dead time by about 6% but shortening of measure time was achieved by 2 seconds per 1 point. Also efficiency of reconstruction algorithm was proved, and memory and calculation amount was decreased by about 1/100 The fixed quantity was confirmed by physical phantom, and iodine distribution was presumed from image of thyroid gland in vitro These result shows realization possibility of fluorescent X-ray computed tomography measure in vivo.

  • PDF

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.