• Title/Summary/Keyword: in pipe

Search Result 5,779, Processing Time 0.033 seconds

A Study on the highly efficient ondol system combined the strengthen polyethylene pipe with pulsating heat pipe (강화폴리에스테르튜브(XL 튜브)에 진동형 히트 파이프를 결합한 고성능 난방 패널의 성능에 관한 연구)

  • Kim, Chang-Hee;Kim, Jong-Su;Woo, Jae-Ho;Kong, Sang-Wun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.578-583
    • /
    • 2008
  • Korea which has change of clear season is using unique heater by the name of On-dol being invented since ancient times. Floor-heating device has no radiator, and generates no noise and dust. It can obtain satisfied heating sense than other heating system in low room temperature. And also it is a pleasant system that equals bottom and top temperature in a room. The purpose of this study is to develop the Floor-heating device using pulsating heat pipe. It propose floor-heating device using pulsating heat pipe of the dry process which alternative polyethylene pipe(low XL pipe) that is used widely to existent floor heating system and produce pilot Experiment and analyzed operation condition and performance of most suitable. In this study, main purpose is to develop floor-heating system using pulsating heat pipe by finding an optimum working condition according to changing ratio and evaluating a performance.

  • PDF

Evaluation and Application of Prediction Models for the Daylight Performance of a Light-Pipe System (광파이프 시스템의 채광성능 예측모델의 검증 및 적용)

  • Yun, Geun Young;Shin, Ju Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • The use of natural light has the potential for improving both the energy efficiency and indoor environmental quality in buildings. A light-pipe system can introduce daylight to spaces that would otherwise not be able to benefit from the advantages of daylight penetration. For the light-pipe system to be widely used in Korea, it is important to quantify its daylighting performance with due consideration regarding the effects imposed by the local climate conditions. This paper presents the evaluation results of existing semi-empirical models to predict daylighting performance of a light-pipe system. The evaluation of the existing models was based on the monitoring data obtained from a underground parking lot in which the light-pipe system was installed. Comparisons were made between the predicted and the monitored data obtained from the study. The results indicated that semi-empirical models which was developed using the experimental data obtained under the Korean climatic conditions had a good prediction performance. We also quantified the effects caused by sky conditions, solar altitudes, room dimensions, and the aspect ratio of a light-pipe system on both the daylighting performance of the light-pipe system and the indoor illuminance distributions of the space using the semi-empirical model. Finally, this paper provides the design guideline of the light-pipe system for its application to an underground parking lot space.

The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance (에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구)

  • Yun, Hiwon;Ryu, Hyung Kyou
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.

The Influence of Moving Masses on Dynamic Behavior of a Cantilever Pipe Subuected to Uniformly Distributed Follower Forces (이동질량과 등분포접선종동력이 외팔보의 동특성에 미치는 영향)

  • Son, In-Soo;Yoon, Han-Ik;Kim, Hyun-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.80-85
    • /
    • 2002
  • A conveying fluid cantilever pipe system subjected to an uniformly distributed tangential follower force and three moving masses upon it constitute this vibrational system. The influences of the velocities of moving masses, the distance between two moving masses. and the uniformly distributed tangential follower force have been studied on the dynamic behavior of a cantilever pipe system by numerical mettled. The uniformly distributed tangential follower force is considered within its ciritical value of a cantilever pipe without moving masses, and three constant velocities and three constant distance between two moving masses are also chosen. When the moving masses exist on pipe, As the velocity of the moving mass and distributed tangental force increases, the deflection of cantilever pipe conveying fluid is decreased, respectively. Increasing of the velocity of fluid flow make the amplitude of cantilever pipe conveying fluid decrease. After the moving mass passed upon the pipe, the tip displacement of pipe is influenced by the potential energy of cantilever pipe.

  • PDF

Dynamic Behavior of a Simply Supported Fluid Flow Pipe with Moving Masses (이동질량들을 가진 단순지지된 유체유동 파이프의 동특성)

  • 윤한익;임순홍
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.2
    • /
    • pp.132-140
    • /
    • 2002
  • A simply supported pipe conveying fluid and the moving masses upon it constitute this vibrational system. The equation of motion is derived by using Lagrange's equation. The influence of the velocity and the inertia force of the moving masses and the velocities of fluid flow in the pipe have been studied on the dynamic behavior of a simply supported pipw by numerical method. The velocities of fluid flow are considered within its critical values of the simply supported pipe without the moving masses upon it. Their coupling effects on the transverse vibration of a simply supported pipe are inspected too. The dynamic deflection of the simply supported pipe conveying fluid is increased by a coupling of the moving masses and the velocities of the moving masses and the fluid flow. When four or five regular interval masses move on the simply supported pipe conveying fluid, the amplitude of the simply supported pipe conveying fluid is small at low velocity of the masses, but at high velocity of the masses the deflection of midspan of the pipe is increased by coupling with the numbers and magnitude of the masses. The time which produce the maximum dynamic deflection of the simply supported pipe is delayed according to the increment of the number of moving masses.

A study on the stress and strain during welding of plate-to-pipe joint (평판-관 구조물 용접시 발생하는 응력 및 변형율에 관한 연구)

  • 나석주;김형완
    • Journal of Welding and Joining
    • /
    • v.4 no.2
    • /
    • pp.30-39
    • /
    • 1986
  • In manufacturing of pipe walls for boiler units, distortion can result in pipe-web-pipe joints from the nonuniform expansion and contraction of the weld metal and the adjacent base metal during heating and cooling cycle of the welding process. In this study, the stresses and strains during longitudinal welding of the plate-to-pipe joint were investigated. Using the method of successive elastic solution, longitudinal stresses and strains during and after welding were calculated from the information of temperature distributions obtained by Rosenthal's equations. In order to confirm the validity of the numerical results, the temperature and residual stress distributions were measured and compared with the calculated results. In spite of some assumptions, the one-dimensional analytical results of residual stresses were in fairly good agreement with the experimental ones. The residual stresses due to welding of plate-to-pipe joints are tensile near the weld line and compressive in the base metal as in the welding of plates. the amount and distribution of residual stresses were deeply dependent on the heat input ratio of the plate and pipe.

  • PDF

A Study on the Status and Improvement of Double Pipe System in Apartment Buildings (공동주택 이중관 공법의 현안 분석 및 개선 연구)

  • Kim, Myoung-Seok;Kim, Youngil;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.37-42
    • /
    • 2013
  • Double pipe system in which PB pipe is inserted in CD pipe buried in the concrete slab is widely used for cold and hot water supplies in apartment housings. The system, however becomes complicated and the overlaying pipes in the concrete slab weaken the compressive strength of the slab. Also, insufficient insulation increases energy loss. In this work, the problems of the double pipe system are studied and plans A, B, and C are suggested for improvement. In terms of compressive strength of the concrete slab, plan A(total pipe length 73 m) was the weakest and plan B(2 m) was the strongest. Energy loss of plan A was the largest with 558.9 W and plan B was the lowest with 220.7 W. However, considering the combined effect of strength and heat loss, plan C becomes the best choice, which retains the advantage of the double pipe system.

Analysis of the Correlation between the Thickness of Support Pin of Pipe Support and the Compressive Load (파이프 서포트의 지지핀 두께와 압축하중의 상관관계 분석)

  • Choi, Myeong Ki;Park, Jongkeun
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.36-43
    • /
    • 2022
  • Generally, in construction sites, the pipe support installation workers often use support pins of 9~10 mm which are much smaller than the safety standard sizes for work convenience. Although the safety certification standard thickness of the support pins is 11 mm, and the supervisors are often indifferent to this. Hence, products with far lower performance than the pipe support safety certification value of 40,000 N, which is applied in the supporting post-structural review, are used. Accordingly, this acts as a factor causing collapse accidents in the process of pouring concrete at the construction site. Therefore, this study performed compression experiments on new and reused pipe supports to determine how the thickness of the support pins affects the structural compression performance of the pipe support by considering the thickness of the support pins as a critical variable among various factors affecting the pipe support performance. In the course of the study, the compression test of the pipe support (V2, V4) for the new products showed that only 14 (58.3%) of the total 24 samples satisfied the safety certification standard value of 40,000 N, which indicates that more thorough quality control is required in the manufacturing process. Additionally, comparing the thickness of the support pins and their fracture shape shows that the pipes with support length of 4.0 m or longer are much more affected by the buckling of the entire length than the thickness of the support pins. Of the several factors affecting the performance of reused pipe supports, it was found that, similar to the new products, the use of support pins, with thickness of 12 mm rather than 11 mm, can satisfy the safety certification value more appropriately. Therefore, regardless of the state of usage, it could be concluded that it is necessary to use 12 mm products, whose thickness is larger than that of the safety certification standard value of 11 mm, to improve the performance of the pipe supports.

Prediction of Flow Behavior and Pressure Drop of Spirally Corrugated Steel Pipe (나선형 파형강관에서의 유동특성 및 압력강하 예측)

  • Park Jong-Hark
    • Journal of computational fluids engineering
    • /
    • v.9 no.2
    • /
    • pp.18-22
    • /
    • 2004
  • Numerical investigation has been conducted to figure out flow behavior and pressure drop characteristics of spirally corrugated steel pipe which is widely used in civil, industrial and agricultural field owing to many advantages such as good corrosion resistance and durability, strength, easy and quick installation. Also the poly-ethylene coating spirally corrugated steel pipe has the long life under condition of sea water immerged. In the present study, flow behavior in the spirally corrugated pipe and influence of P/d/sub h/(ratio of wave pitch to hydraulic diameter) to pressure drop are investigated by CFD with various Reynolds number. And also friction factor is estimated by pressure drop obtained by flow analysis. According to computation results, the flow runs spirally up and down along the spiral corrugation in the vicinity of wall, but the effect of spiral corrugation disappears in core region of pipe. As P/d/sub h/ becomes small, more pressure drop occurs in spirally corrugated Pipe. Besides, friction factor augmentation becomes much larger as Re increases. In case of p/d/sub h/=0.38, Pressure drop and friction factor of spirally corrugated pipe are about four times larger than smooth pipe at Re: 1.46×10/sup 6/.

Evaluation of Local Allowable Wall Thickness of Thinned Pipe Subjected to Internal Pressure and Bending Moment (내압과 굽힘하중하에서 감육배관의 국부허용두께 평가)

  • Kim, Jin-Won;Park, Chi-Yong;Kim, Beom-Nyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.1
    • /
    • pp.81-88
    • /
    • 2001
  • This study proposed an analytical method to evaluate a local allowable wall thickness (LAWT) for locally thinned pipe subjected to internal pressure and bending moment. In this method, the stresses in the thinned region were calculated by finite element analysis and plastic collapse was applied as a failure criterion of thinned pipe. Using this method, LAWT for a simplified thinned pipe was evaluated with variation in axial extent of thinned area, and it was compared with allowable wall thickness provided by previous pipe wall thickness criteria. The results showed that the LAWT was lower, about 50%, than that calculated by construction code or ASME Code N-597, and it was higher, about 2 times, than that estimated by evaluation model based on pipe experiments. In addition, LAWT was decreased with increasing axial extent of thinned area and saturated with further increase in axial extent. And, the variation in LAWT with axial extent of thinned area depended on type of load, especially a magnitude of bending moment, considering in the evaluation.