• Title/Summary/Keyword: impurity elements

Search Result 68, Processing Time 0.023 seconds

Analysis of $Si_3N_4$ Ultra Fine Powder Using High-pressure Acid Digestion and Slurry Injection in Inductively Coupled Plasma Atomic Emission Spectrometry

  • Kim, K.H.;Kim, H.Y.;Im, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.159-163
    • /
    • 2001
  • Si3N4 powder has been analyzed by inductively coupled plasma atomic emission spectrometry (ICP-AES). The sample was dissolved by high-pressure acid digestion with HF, H2SO4 (1+1), and HNO3 mix ture. This technique is well suited for the impurity analysis of Si3N4 because the matrix interference is eliminated. A round-robin samples trace elements, such as Ca, W, Co, Al, Fe, Mg, and Na, were determined. For the direct analysis, slurry nebulization of 0.96 mm Si3N4 powder also has been studied by ICP-AES. Emission intensities of Fe were measured as ICP operational conditions were changed. Significant signal difference between slurry particles and aqueous solution was observed in the present experiment. Analytical results of slurry injection and high-pressure acid digestion were compared. For the use of aqueous standard solution for calibration, k-factor was determined to be 1.71 for further application.

Impurity variation in high purity silica mineral with different leaching methods (실리카광물의 산침출 정제방법에 따른 불순물 변화 연구)

  • Yoon, Yoon Yeol;Lee, Kil Yong;Cho, Soo Young;Chung, Soo Bok;Chae, Young Bae
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.332-337
    • /
    • 2008
  • Purification of silica mineral was compared with various leaching methods such as shaking, stirring, ultrasonic with 2.5% HF/HCl solution. Among them, ultrasonic method showed a best leaching effect. From the leaching experiment, Na, K, Fe, Al exist as the major impurity elements. The removal rate of Al, Fe showed little difference with various leaching methods but Ca, Mn, Na were very different. Four kinds of silica mineral (>99% purity) after physical purification treatment were used for ultrasonic leaching experiment. Among them IN-Si had a highest impurity removal rate. Ca, Cr, K, Zn were removed above 80% using ultrasonic leaching method and Fe was also removed above 60%. But Al showed 10~60% removal rate with different samples.

Reactor Neutron Activation Analysis by a Single Comparator Method

  • Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.137-149
    • /
    • 1973
  • A method of activation analysis, based on the irradiation and counting of an iron wire which contains manganese impurity as the single comparator. has been elaborated by critical evaluation of nuclear data involved in activation and activity measurement. The variation of effective cross section is investigated as a function of the spectral index and other parameters such as a measure of the proportion of epithermal neutrons in the reactor spectrum. The errors induced by shifts in the neutron spectrum in the irradiation positions are discussed. The known amount of each element is irradiated simultaneously together with the single comparator, and the obtained values are compared with the known amount of each element. The results show that en general the random errors are not greater than those obtained by using the conventional relative method, but the systematic errors were up to about 20%. This method is applied to the determinations of fourteen rare earth elements in monazite as well as other seven elements in the standard kale powder. The satisfactory reproducibility of the present method makes possible the determination of the elements with an accuracy attainable with the conventional relative method.

  • PDF

Variations of Mechanical Properties and Corrosion Rate with Melting Conditions and Alloying Elements in High Silicon Cast Irons (용해조건 및 합금원소 첨가에 따른 고규소 내산주철의 기계적 성질 및 부식속도의 변화)

  • Kim, Jung-Chul;Han, Dong-Woon;Baik, Jin-Hyun;Baik, Seung-Han;Moon, Byung-Moon;Shin, Je-Sik;Lee, Young-Kuk
    • Journal of Korea Foundry Society
    • /
    • v.24 no.4
    • /
    • pp.209-216
    • /
    • 2004
  • High silicon cast irons(HSCI) with the high acid resistance have been used for the prevention of acid corrosion occurring in various structures under acid conditions. However, the HSCI is only known as one of materials which have high acid resistance, but few work has dealt with this material in domestic. Therefore, in this study, the acid resistance of various cast irons with alloying elements and melting conditions have been examined, and studied the influences of the matrix structures, mechanical properties and morphologies of graphite. The results obtained in this study are as follows : In case of melting temperature, the mechanical properties of specimen manufactured with high temperature of $1650^{\circ}C$ showed higher value because the inclusion and impurity were removed. In case of pouring temperature, the mechanical properties of specimen fabricated below $1350^{\circ}C$ of pouring temperature showed higher value because the amount of gas absorption from atmosphere decreased during the solidification time. The corrosion rate decreased with increase in Si content. On the other hand, Mn addition appeared an opposite trend with Si.

Study on the Separation and Determination of Pure Rare Earth Oxides by Anion Exchange Resin (음이온 교환수지에 의한 고순도 희토류산화물의 분리 및 정량에 관한 연구)

  • Cha, Gi Won;Ham, Yun Beom
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.606-615
    • /
    • 1990
  • The purity of CeO$_2$, Sm$_2$O$^{3+}$ and La2O$^{3+}$ have been determinated by separating the impurity of rare earth-elements in those oxides with anion exchange resin and measuring the absorbance of the separated element with MTB. 1 ml of the mixture solution containing each 1 mg/ml of Y$^{3+}$, Yb$^{3+}$, Eu$^{3+}$, Sm$^{3+}$, Nd$^{3+}$, Pr$^{3+}$, Ce$^{4+}$and La$^{3+}$ is loaded in top layer of anion exchange resin column, Amberlite CG400 and separated with the mixture solution of the various concentration of methyl alcohol and nitric acid as an eluent. Using the result, the impure rare earth elements in pure CeO$_2$, Sm$_2$O$^{3+}$ and La$_2$O$^{3+}$ are determinated.

  • PDF

A Suitability Study on the Indicator Isotopes for Graphite Isotope Ratio Method (GIRM) (흑연 동위원소 비율법의 지표 동위 원소 적합성 연구)

  • Han, Jinseok;Jang, Junkyung;Lee, Hyun Chul
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.1
    • /
    • pp.83-90
    • /
    • 2020
  • The Graphite Isotope Ratio Method (GIRM) can verify non-proliferation of nuclear weapon by estimating the total plutonium production in a graphite-moderated reactor. Using the reactor, plutonium is generated and accumulated through the 238U neutron capture reaction, and impurities in the graphite are converted to nuclides due to the nuclear reaction. Therefore, the amount of plutonium production and concentration of the impurities are correlated. However, the plutonium production cannot be predicted using only the absolute concentration of the impurities. It can only be predicted when the initial concentration of the impurities is obtained because the concentration, at a certain time, depends on it. Nevertheless, the ratios of the isotopes in an element are known regardless of the impurity of an element in the graphite moderator. Thus, the correlation between the isotope ratio and amount of plutonium produced helps predict plutonium production in a graphite-moderated reactor. Boron, Lithium, Chlorine, Titanium, and Uranium are known as indicator elements in the GIRM. To assess whether the correlation between the indicator isotope and amount of plutonium produced is independent of the initial concentration of the impurities, four different impurity compositions of graphite were used. 10B/11B, 36Cl/35Cl, 48Ti/49Ti, and 235U/238U had a consistent correlation with the cumulative plutonium production, regardless of the initial impurity concentration of the graphite, because these isotopes were not generated through the nuclear reaction of other elements. On the other hand, the correlation between 6Li/7Li and plutonium production depended on the initial concentration of the impurities in graphite. Although 7Li can be produced through the neutron capture reaction of 6Li, the (n, α) reaction of 10B was the major source of 7Li. Therefore, the initial concentration of 10B affected the production of 7Li, making Li unsuitable as an indicator element for the GIRM.

Effects of Fe and Si Additions on the Ageing Behaviors for High Strength Al-Cu-Mn-Ti-Zr-Cd Casting Alloys (Fe과 Si의 첨가가 주조용 고강도 Al-Cu-Mn-Ti-Zr-Cd 합금의 시효경화거동에 미치는 영향)

  • Kim, Chul-Hyo;Lee, Jeong-Moo;Kim, Kyung-Hyun;Kim, In-Bae
    • Journal of Korea Foundry Society
    • /
    • v.24 no.1
    • /
    • pp.45-51
    • /
    • 2004
  • Fe and Si are common impurity elements in the aluminum alloys. In this investigation, the effects of the addition of Fe and Si on the age-hardening behaviors of the Al-Cu-Mn-Ti-Zr-Cd casting alloys were examined through hardness measurements, calorimetric techniques and observation of the transmission electron microscopy. The addition of Fe depresses the formation of GPII and ${\theta}'$, and thus retards the peak aging time and reduces the peak hardness of the Al-Cu-Mn-Ti-Zr-Cd alloys. On the contrary, the addition of Si accelerates the formation of GPII and ${\theta}'$ and thus accelerates age-hardening behaviors of the Al-Cu-Mn-Ti-Zr-Cd alloys.

Recent Developments in Nuclear Forensic and Nuclear Safeguards Analysis Using Mass Spectrometry

  • Song, Kyuseok;Park, Jong-Ho;Lee, Chi-Gyu;Han, Sun-Ho
    • Mass Spectrometry Letters
    • /
    • v.7 no.2
    • /
    • pp.31-40
    • /
    • 2016
  • The analysis of nuclear materials and environmental samples is an important issue in nuclear safeguards and nuclear forensics. An analysis technique for safeguard samples has been developed for the detection of undeclared nuclear activities and verification of declared nuclear activities, while nuclear forensics has been developed to trace the origins and intended use of illicitly trafficked nuclear or radioactive materials. In these two analytical techniques, mass spectrometry has played an important role in determining the isotope ratio of various nuclides, contents of trace elements, and production dates. These two techniques typically use similar analytical instruments, but the analytical procedure and the interpretation of analytical results differ depending on the analytical purpose. The isotopic ratio of the samples is considered the most important result in an environmental sample analysis, while age dating and impurity analysis may also be important for nuclear forensics. In this review, important aspects of these techniques are compared and the role of mass spectrometry, along with recent progress in related technologies, are discussed.

Evaluation of Elastic-Plastic Fracture Toughness of Aged AISI 316 Steel Using DC-electric Potential Method (직류전위차법을 이용한 AISI 316강 시효재의 탄소성 파괴인성 평가)

  • Lim, Jae-Kyoo;Chang, Jin-Sang;Lino, Y.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.519-527
    • /
    • 1997
  • AISI 316 steel has been used extensively for heater and boiler tube of the structural plants such as power, chemical and petroleum plants under severe operating conditions. Usually, material degradation due to microcrack or precipitation of carbides and segregation of impurity elements, is occured by damage accumulated for long-term service at high temperature in this material. In this study, the effect of aging time on fracture toughness was investigated to evaluate the measurement of material degradation. The elastic-plastic fracture toughness behaviour of AISI 316 steel pipe aged at $550^{\circ}C$for 1h-10000h (the aged material) was characterized using the single specimen J-R curve technique and eletric potential drop method at normal loading rate(load-line displacement speed of 0.2mm/min) in room temperature and air environment. The fracture toughness data from above experiments is compared with the $J_{in}$ obtained from predicted values of crack initiation point using potential drop method.

Study on Reliability of Vapor Cell by Laser Packaging with Au/Au-Sn Heterojunction (Au/Au-Sn 이종접합 적용 레이저 패키징을 통한 Vapor Cell 신뢰성 연구)

  • Kwon, Jin Gu;Jeon, Yong Min;Kim, Ji Young;Lee, Eun Byeol;Lee, Seong Eui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.5
    • /
    • pp.367-372
    • /
    • 2020
  • As packaging processes for atomic gyroscope vapor cells, the glass tube tip-off process, anodic bonding, and paste sealing have been widely studied. However, there are stability issues in the alkali metal which are caused by impurity elements and leakage during high-temperature processes. In this study, we investigated the applicability of a vapor cell low-temperature packaging process by depositing Au on a Pyrex cell in addition to forming an Au-Sn thin film on a cap to cover the cell, followed by laser irradiation of the Au/Au-Sn interface. The mechanism of the thin film bonding was evaluated by XRD, while the packaging reliability of an Ne gas-filled vapor cell was characterized by variation of plasma discharge behavior with time. Furthermore, we confirmed that the Rb alkaline metal inside the vapor cell showed no color change, indicating no oxidation occurred during the process.