• 제목/요약/키워드: implementation stage

검색결과 963건 처리시간 0.033초

VIDEO GAME CULTURE AND INTERACTIVITY -An exploration of digital interactive media through a metaphorical approach to video game culture-

  • 우탁
    • 한국게임학회지
    • /
    • 제6권1호
    • /
    • pp.70-72
    • /
    • 2009
  • This research is focused on defining interaction within the context of digital media and creating a multi cultural definition of interactivity. The concept of multi digital culture and a definition of interaction in digital media have often been overlooked by other researchers and this has caused the emergence of many different notions on this issue. As a result of these varied notions of the concept, public confusion has arisen regarding interactivity. The main purpose of this research is to find a suitable multi definition of interaction through examining local digital culture. In order to analogise multi digital culture, the video game culture is employed as a metaphor to interpret local digital culture. The reason for this is that a specific national culture can be easily identified within the video game culture. Four countries, South Korea, Japan, the U.S. and the UK have been chosen for comparison purposes. Case study, questionnaire and publicly accessible video game related data, such as, video game charts, are used for formalising and analysing unique local digital culture. The Heyri POP UP IMAGE Festival, S. Korea, was also used as a pilot study, with some of the above research methods being employed to analyse South Korean digital culture. In relation to western cases, interview and questionnaire were primarily used. The data from the case countries was carefully compared and analysed and then it became the basis of a theory of multi definition of interaction in digital media. The case study employed the cultural metaphor for this research and in addition video game culture related questionnaires and interviews with experts of interactive art genre, regarding new notions of digital interaction were utilised. The survey was conducted simultaneously in the four different cultural case nations of this research. Twenty respondents from each case nation participated in the survey, in order to investigate firstly, the existence of 'local digital culture' and secondly, the trends and phenomena of 'digital culture' in these four different 'local digital cultural areas'. In terms of interviews with experts of the interactive art genre, these were focused on obtaining their understanding of contemporary digital culture in their research. Using gathered data from the observation of local digital culture, the basic theory of interaction and the terminology of interaction are reformed. Localised definitions of interaction on digital media, control based interaction and communication based interaction are presented, in order to identify a 'locality' in terms of various contemporary digital cultures. As a result of analysing digital culture, new definitions of 'multi definition of digital interaction' were formulated. As mentioned above, 'control' and 'communication' based interaction were initiated, based on 'user to media' relationships. Based on the degree of physical interaction, 'liminal' and 'transitive' interactions were initiated. Less physical digital interaction is named 'liminal' interaction and more physical digital interaction is named' transitive' interaction. These new definitions of interaction were applied to the real world examples of uses of digital interaction, such as, digital interactive installation artworks and video games. The newly defined meaning of digital interaction can be applied to analysing digital interactive installation artworks and possibly indicate their future development and the prospects of future electronic games. Three leading digital interactive artists were selected for this analysis and their works were studied in terms of the implementation of 'multi definition of digital interaction'. Throughout these processes, the meaning of 'communication' in digital interactive media was emphasised. Many of the selected artists' digital installations were focused on 'communication' or 'interaction between each user through digital media', rather than the concept of 'control' in digital interaction, otherwise termed, 'communication with digital media'. In their artworks, interaction between each audience was digitally engaged within the physical interactive environment which was created by the digital media. Both the audience's action and all the reaction throughout the interaction between the audiences, triggered the digital media' s reaction. This audience-audience-media interaction is the key to understanding the concept of 'communication' in physical digital media and it is the main interactive concept upon which the selected digital interactive installation artists for this research and many other artists from similar fields, are concentrating their efforts. In the case of the video game, a similar trend was noticed to that of digital interactive installations. Based on this research's 'multi definition of digital interaction', the video game has evolved from the early stage of being conventional game, which was focused on control based interaction, to the on-line game which was focused on communication based interaction, to physical interactive games, such as, Nintendo Wii, which are focused on more physical interaction and finally, the ubiquitous interactive game, which is mainly concentrated on the concept of 'communication' in physical digital interaction. It is possible that this evolution of the video game concept of interaction is comparable to the progress of digital interactive artworks. This view is based on the fact that both genres show evidence that they are developing in the direction of the concept of 'communication', in terms of physical digital interaction. The important emphasis of this research's results is 'locality' and 'communication' in physical digital interaction. The existence of different digital culture trends, which were assessed by the 'multi definition of digital interaction', can explain the concept of 'locality' in digital interaction. This meaning of 'locality' may assist in understanding contemporary digital culture and can reduce possible misunderstanding as regards 'local' digital culture. In the application of the concept of digital interaction to the field of either artworks or video games, it is possible to form the opinion that an innovative concept of physical digital interaction is 'communication' within this context. This concept and its applications can improve the potential of both digital interactive culture and technology.

  • PDF

의류소매업에서의 RFID 이점에 대한 탐색적 연구 (An Exploratory Study of REID Benefits for Apparel Retailing)

  • 김혜정;김은영
    • 한국의류학회지
    • /
    • 제30권12호
    • /
    • pp.1697-1707
    • /
    • 2006
  • 최근 정보기술 분야에서 새로이 부상하고 있는 RFID는 기존의 노동비용을 절감하고 재고관리를 개선하며, 또한 효율적인 사업모델 창출을 통해 판매를 증가시킬 수 있는 혁신적인 정보기술로 소개되고 있다. 따라서, 이 새로운 정보기술의 채택이 의류소매업에 가져올 수 있는 이점은 무엇이며, 또한 무엇이 RFID 기술을 실용화하는 데에 성공적 요인이 될 것인지를 생각해 볼 시점이다. 본 연구는 RFID기술에 대한 의류소매업자의 현실적 인식수준과 그들이 예측하는 RFID잠재적 이점을 탐색하고자 하였다 또한 이를 통해 의류소매업에서 RFID 실행가능성을 예측해 보고자 하였다. RFID 기술에 대한 경험적 연구가 매우 드문 시점에서, 본 연구는 미국 내 소매업자들을 대상으로 집중집단면접(Focus group interview)를 실시하였다. 질적 내용 분석 결과, 총 150개의 RFID관련 문항이 도출되었고, 이는 다시 다섯 개의 RFID 이점 차원에 따라 31개의 속성으로 분류되었다. RFID 기술과 그의 이점에 대해 소매업자들은 이 기술이 현존하는 유통 공급망 체계를 보다 신속, 효과적으로 만들 것으로 인식하고 있었다. 그러나 실제 이 기술에 대한 채택은 아직까지 소수의 혁신적 기업만이 시도하는 초기 채택단계 이전에 머무르고 있었다. 한편 의류 소매업자들이 인식한 중요한 RFID 이점은 다섯 차원, 즉 (1) 물류 및 재고관리의 가시성과 가속성, (2) 수익률 향상, (3)고객 서비스, (4) 보안성, (5) 고용생산성으로 밝혀졌다. 이러한 결과는 RFID가 신속하고 효율적인 유통 공급망의 관리, 매장 운영 및 관리의 개선, 그리고 고객서비스 강화에 중요한 잠재력을 지닌다고 제시한 선행연구들의 이론적 가설 및 제언을 지지하였다. 따라서 본 연구는 의류소매업에서 RFID 기술에 대한 학문적 연구 및 실무적 접근 방향을 위한 기초자료를 제시하고 있다.2%, Bacillus cereus가 0.0%에서 29.4%, Clostridium perfringens는 0.0%에서 23.1%, Escherichia coli는 0.0%에서 35.0%로 검출되었다. Escherichia coli O157:H7, Salmonella spp., Vibrio parahaemolyticus, Listeria monocytogenes, Yersinia enterocolitica, Campylobacter jejuni는 검출되지 않았다. 이 연구는 신선한 야채에서의 병원체에 대한 기초 자료로 활용 가능할 것이라 기대된다.m}1.82$로서 명도와 황색도가 다소 낮게 나타났다. 청국장은 각각 $35.62{\pm}2.05,\;6.31{\pm}0.37$$13.50{\pm}0.78$로 나타나 명도와 황색도에 있어서 다소 낮게 나타났다.m25$에 9.4%를 나타내었다. 신체발달점수에서 남대생은 68.3%가 $75\sim85$이었고, 86 이상이 25.3%로 나타난 반면, 여대생은 표준범위가 63.6%의 분포를 나타내었다. 여대생의 나트륨 섭취는 연령과 0.082의 유의성을 나타내었고, 남대생의 복부 지방률은 연령과 0.011의 유의적 차이를 나타내었으며, 여대생의 체단백질랑은 나트륨섭취와 -0.276의 음의 상관관계를 나타내었다. 따라서 본 조사에 의하면 탄수화물:단백질:지방 비율이 $46\sim54:16\sim17:30$ 이상의 수준이었고, 섬유소는 권장량의 20%, 칼슘은 권장량의 $77\sim83%$, 나트륨은 권장량의 $2\sim3$배를 섭취하였는데, 이러한 섭취경향은 체성분에서 특히 남대생 94%가 체단백질량이 표준이상인 반면 남대생 86.4%가 체무기질량이 표준이하를 나타내었으며,

KODISA 학술지 성장전략: 2017 개관 및 미래 성장개요 (Future Development Strategies for KODISA Journals : Overview of 2017 and Strategic Plans for the Future)

  • 황희중;신동진;이정완;김동호;이종호;김병구;김태중;이용기;서응교;강민수;서원재;김종진;장범;소수;윤명길
    • 유통과학연구
    • /
    • 제16권5호
    • /
    • pp.83-90
    • /
    • 2018
  • Purpose - Journals of Korea Distribution Science Association (KODISA) made great efforts in responding to the constant shifts in academic paradigms and in producing synergetic effects among KODISA journals to achieve the goal of maintaining their status in the world's reputable scholarly journals. The aim of this study is to analyze the current practice and performance of KODISA journals and develop strategies that will continuously meet and respond to the changes and success in the future. Research design, data, and methodology - This is a case study, an analytical approach, which focuses on analyzing current and previous strategies, practices, and performances of the four major journals of KODISA and the association. The organizational structure, including election and terms of KODISA officers, new membership, and members of editorial board, is discussed and analyzed. The citation, submission, publication, and rejection rates of all four journals are examined, and the progress, including the status of indexing of each journal, is discussed. Results - The analysis indicates that KODISA has significantly invested its resources into improving its journals and attracting new members. The analysis also shows the strategy of the organizational structure, which includes election and terms of officers and editorial board members that implemented over the years, was successful. Both Journal of Distribution Science (JDS) and Journal of Finance, Economics, and Business (JAFEB) are indexed in SCOPUS, with East Asian Journal of Business Management (EAJBM) in the final stage of the SCOPUS indexing evaluation, and International Journal of Industrial Distribution and Business (IJIDB) will complete and submit their indexing evaluation materials to SCOPUS this summer. Conclusions - The success and progress of KODISA and its journals clearly support the need for continuous development, analysis, revision, and implementation of strategies. Based on the analysis, conducting the annual performance reviews of the association and its journals and planning and strategizing based on the reviews since 2011 have greatly contributed to the overall success. In terms of meeting the short term strategy, KODISA has to continue developing relationships with relevant and appropriate scholarly/academic associations to expand the scope of its business, establishing independence of each journal and its respective procedures and practices and improving the quality of the journals and their publications through KODISA's international conferences.

포트폴리오 평가를 적용한 가정과 주생활 교수.학습 과정안 개발 및 실행 -'주거와 거주환경' 단원을 중심으로 - (Development and Implementation of Teaching-Learning Plan for 'Residence and Living Environment' of Home Economics applied with Portfolio Assessment)

  • 이민정;조재순
    • 한국가정과교육학회지
    • /
    • 제24권3호
    • /
    • pp.225-239
    • /
    • 2012
  • 이 연구는 학생 개개인의 수업과정을 종합적으로 평가할 수 있는 포트폴리오 평가를 가정 교과에 활용하고자 2007년 개정 교육과정의 기술 가정 교과의 8학년 '주거와 거주환경' 단원에 적용할 수 있는 교수 학습 과정안과 포트폴리오 평가 자료를 개발하여 실제로 교실 수업에 실행하여 평가가 통합된 수업을 실현하고 효과를 분석하는데 목적을 두고 있다. 이를 위해 ADDIE 교수설계모형에 따라 분석, 설계, 개발, 적용, 평가 단계로 연구를 진행하면서, 조한무의 포트폴리오 개발 단계가 포함되도록 하였다. 분석단계에서 교수 학습목표와 교수 학습내용을 선정하고. 설계단계에서는 교수 학습 과정안과, 포트폴리오 평가 자료 개발, 수업 실행 및 수업 평가에 대한 계획을 세웠다. 개발단계에서는 매 차시 작성한 활동자료를 모아 포트폴리오 결과물이 완성될 수 있도록 8차시 교수 학습 과정안과 포트폴리오 평가자료(읽기자료, 5개, 개인활동지 5개, 모둠활동지 2개, 주제활동지 3개, 자기평가지 8개)와 수업에 활용될 교수 학습자료(동영상 19개, 사진 8세트), 수업 평가용 설문지, 결과물 평가기준을 개발하였다. 이를 경기도 부천시 소재 K중학교 3학년 2학급 학생 74명을 대상으로 2011년 5월 16일~6월 17일에 실행하고 설문지 평가와 수업의 결과물인 포트폴리오에 대한 평가를 실시하였다. 질문지를 통해 알아본 수업에 대한 평가는 전반적인 소감, 평가를 겸한 수업과정, 학습목표달성도가 모두 높았으며, 세 가지 소단원 주제활동지를 포함한 포트폴리오 결과물도 평균 92점 정도로 우수하였다. 이러한 결과를 바탕으로 이 연구에서 포트폴리오 평가를 적용하여 개발한 교수 학습 과정안은 평가가 통합된 수업으로서 적정하고 효과적이었다고 결론내릴 수 있다. 이 연구에서 다루지 못한 통제집단과의 수업효과 비교, 포트폴리오 적용수업의 전후비교, 소수 어려움을 표시한 학생 지도방안, 개별학생의 지속적인 변화와 발달과정을 분석하는 후속연구를 제안한다.

  • PDF

창의.인성 교육을 위한 가정과 프로젝트 교수.학습안 개발 및 효과 - '주거 공간 활용' 단원을 중심으로- (Development and implementation of project teaching-learning plan for 'residential space utilization' of home economics for creativity and character education)

  • 최경수;조재순
    • 한국가정과교육학회지
    • /
    • 제25권2호
    • /
    • pp.1-19
    • /
    • 2013
  • 이 연구는 2007년 개정 교육과정 기술 가정 교과의 8학년 '주거 공간 활용' 단원에서 '다양한 가족의 특성을 고려한 주거 공간 디자인'을 주제로 프로젝트 학습을 적용한 교수 학습 과정안과 학습 자료를 개발하고 실제 교실 수업으로 실행하여 수업 후의 창의성과 인성 요소를 측정하고, 그 효과를 분석하는데 목적이 있다. 이러한 연구 목적을 달성하기 위하여 분석, 설계, 개발, 실행, 평가 단계로 연구를 진행하면서 이춘식과 이수정(2003)의 프로젝트 학습 단계를 적용하였다. 분석단계에서는 교육과정, 교과서, 선행연구를 분석하여 교수 학습 과정안의 단원과 총괄목표를 선정하고, 설계단계에서는 프로젝트 학습 단계, 창의성과 인성의 평가 요소에 대한 계획을 세웠다. 개발 단계에서는 매 차시 창의 인성 기법을 적용한 15차 시 교수 학습 과정안, 프로젝트 학습을 위한 수업 자료(개별 활동지 7개, 모둠 활동지 1개, 동영상자료 4개, ppt자료 2세트, 학습 자료 1개, 주택 도면집 1개), 수행평가 기준안, 창의 인성 검사 도구, 프로젝트 학습의 흥미도 및 만족도 평가 도구를 개발하였다. 이를 광주광역시 소재 G중학교 2학년 5학급 163명을 대상으로 2011년 10월 17일부터 11월 18일까지 5주간 실행한 후, 창의 인성 검사지, 수행평가 결과물, 프로젝트 학습의 흥미도 및 만족도 설문조사, 교사의 수업평가를 분석하였다. 주거 공간 디자인 프로젝트 학습은 창의성의 요소인 유창성, 융통성, 독창성, 정교성과 인성의 요소인 배려심과 협동심을 교육시키는데 효과적이었다. 또한 다양한 형태의 가족을 고려한 주거 디자인 작품이 완성되어 학습목표의 달성에 효과적이었으며, 학습자로 하여금 성취감을 느끼게 하여 수업의 흥미도와 만족도가 높았다. 후속연구에서는 비교집단을 두어 사전사후 뿐만 아니라 두 집단간의 차이분석을 통해 정밀한 효과 분석을 시도해 볼 것을 제언한다. 또한 창의 인성 교육의 효과를 분석하기 위한 신뢰도 높은 검사 도구 개발과 현 교육과정을 기본으로 한 실제적인 프로젝트 학습 모형을 개발하는 후속연구를 제안한다.

  • PDF

DMB에서의 양방향 데어터방송 서비스도입에 관한 연구 (Research for Application of Interactive Data Broadcasting Service in DMB)

  • 김종근;최성진;이선희
    • 방송과미디어
    • /
    • 제11권4호
    • /
    • pp.104-117
    • /
    • 2006
  • 디지털 융합과 유비쿼터스 시대의 시작은 디지털 미디어 기술의 발전과 방송 통신 사업의 융합을 가속화시켰으며, 그 결과 DMB(Digital Multimedia Broadcasting), WCDMA(Wide-band code division multiple access), Wibro(Wireless Broadband Internet), IP-TV(Internet protocol TV), HSDPA(High speed downlink packet access)등의 새로운 형태의 휴대형방송통신융합서비스들이 멀티미디어 매체의 핵심으로 등장하고 있다. 국내에서 방송 통신 융합의 빠른 진행은 세계 최초로 디지털멀티미디어방송(DMB)을 가능하게 하였다. DMB는 멀티미디어와 양방향 데이터방송 서비스가 핵심이다. 데이터 방송은 현재 지상파 DMB 방송사업자자인 KBS, MBC, SBS, YTN DMB가 본 방송을 위한 막바지 준비단계를 마쳤다. [1] 데이터 방송은 뉴스, 날씨, 프로그램 정보 등의 단순 정보서비스 수준에 그치지 않고, 리턴 채널을 이용한 양방향 정보서비스 및 SMS, 전화 걸기 등 휴대전화 단말의 고유기능과의 연계을 통한 다양한 멀티미디어 서비스가 제공될 것이다. 더 나아가 향후 T-Commerce와 개인 광고 등 새로운 서비스 모델과 사업영역을 확산시켜 나아갈 수 있을 것이다. 그러나 아직까지 휴대형방송통신융합서비스는 초기 진입 단계로 표준 기술의 규격 작업, 이론적 논의들, 융합 모델의 전개, 그리고 관련 사업자들의 서비스 준비 등이 실제 이용자들을 대상으로 한 연구 분석이 사전에 검토되어 이루어지지 않았다는 연구의 한계를 가지고 있다. 본격적으로 휴대형방송통신융합서비스가 시작되면서 사용자들에 초점을 맞춘 연구가 이루어지길 바라며, 이러한 연구 분석을 통해 또 다른 새로운 서비스와 기술 발전의 기회를 마련할 수 있기를 기대해 본다.록 한 반면, 한국의 경우에는 정해진 세부사항 없이 크게 ABCD체제의 방식과 출석상황, 중간고사, 기말고사, 과제물 완성도 등을 퍼센티지로 나누어 평가하고 있었다. 학생들에게 주어지는 균등한 기회나 평등의 문제도 학생들의 자격, 신분 등이 거의 다르지 않은 한국에서는 그리 중요한 사항은 아니었으나 다민족 국민으로 이루어진 영국의 학생들에게는 아주 민감한 사항임을 알 수 있었다.서 시베리아 연안을 따라 남부 연안까지 남하하는 한 줄기가 있음을 알 수 있었다. 점차 수심이 깊어지면서 동해 남 북부 전체를 ESPW로 채우고 있어 어떤 흐름의 특징보다는 동해 전체의 상당한 부피를 차지함을 알 수 있었다(Fig. 7d). 동해 북부해역에서 생성되는 냉수들이 연안을 따라서 동해 남부해역으로 이동하는 흐름을 보여주었다. 따라서 동해 내부 순환의 큰 줄기는 연안을 따라 흐르는 냉수들의 흐름이며, 매년 동해남부 해역에 발생하는 용승 현상도 이러한 흐름의 연장선에 있음을 짐작할 수 있다(Lee and Kim 2003).지고 1990년부터는 본격적인 양산 시대에 접어들게 되었다. 1990년대 초에는 STN LCD의 Color화 및 대형화(大型化) 고(高)품위화에 힘입어 Note-Book PC에 LCD가 본격적으로 적용이 되었고, 1990년대 후반에는TFT LCD의 표시품질 대비 가격경쟁력 확보로 인하여 Note-Book PC 시장을 독점하기에 이르렀다. 이후로는 TFT LCD의 대형화가 중요한 쟁점으로 부각되고 있고, 1995년 삼성전자는 당시 세계최대 크기의 22' TFT LCD를 개발하였다. 또한 LCD의 고정세(高情細)화를 위해 Poly Si TFT LCD의 개발이 이루어졌고, 디지타이져 일체형 LCD의 상품화가 그 응용의 폭을 넓혔으며, LCD의 대형화를 위해 1994년 Canon에 의해 14.8', 21' 등의 FLCD가 개발되었다.

BRM기반 국정과제와 정책정보콘텐츠 연계 및 구축방안에 관한 연구 (A Study on the Linkage and Development of the BRM Based National Tasks and the Policy Information Contents)

  • 노영희;장인호;심효정;곽우정
    • 정보관리학회지
    • /
    • 제39권4호
    • /
    • pp.191-213
    • /
    • 2022
  • 기존 국립세종도서관 정책정보포털(POINT)의 국정과제 서비스를 뛰어넘는 고품질 정책정보서비스 제공을 위하여, 새로운 국정과제 이행에 필요한 정책자료를 효과적으로 서비스할 수 있는 방안이 필요하다고 생각된다. 이에 본 연구에서는 BRM기반 국정과제와 정책정보콘텐츠 연계 및 구축방안을 모색하고자 하였다. 이를 위해, 첫째, 신(新)정부 120대 국정과제를 중심으로 국정과제 유형과 정부기능분류체계 분야·영역별 콘텐츠를 분석하였다. 또 이전 정부의 국정과제와 현 정보의 국정과제를 비교·분석하여 국정과제 관련 콘텐츠 구축 시 중점적으로 반영해야 할 내용을 파악하였다. 둘째, 정책정보 및 국가 정보 포털의 현황 분석 등을 통해 정책 정보의 연계 및 수집 방안을 모색하였다. 연구 결과, 첫째, 국정과제의 1단계 BRM을 보면, 사회복지 21개, 통일외교 14개, 산업통상중소기업 17개, 일반공공행정 12개, 재정세제금융이 8개, 문화체육관광과 과학기술, 교육이 각 6개, 통신과 공공질서및안전이 5개, 보건, 교통및물류, 환경이 각 4개, 농림 3개, 국방, 지역개발이 각 2개, 해양수산이 각 1개 등의 순으로 나타났다. 신(新)정부의 경우 과학기술과 IT를 중시하는 것을 알 수 있어 핵심 국정과제 정보서비스 구축 시에도 이를 고려할 필요가 있다. 둘째, 외부 기관과의 데이터베이스 연계를 위해서는 연계운영협의회를 구성하고, 국정과제 정보의 연계 및 수집, 국정과제 관련 정보 POINT 연계 및 제공이 필요하다.

초등 과학 수업에서 가상현실과 증강현실 콘텐츠 활용을 위한 교사 교육 모델의 개발과 적용 사례 (Development and Application of the Teacher Education Model for Using Virtual and Augmented Reality Contents in Elementary Science Class)

  • 차현정;가석현;윤혜경
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제43권3호
    • /
    • pp.415-432
    • /
    • 2024
  • 이 연구에서는 가상현실과 증강현실(Virtual and Augmented Reality: VR/AR) 콘텐츠 활용 과학 수업을 위한 교사 교육 모델과 원리를 개발 및 적용하고, 적용 과정에 참여한 초등 예비 교사의 교사 교육 모델에 대한 의견과 VR/AR 콘텐츠 활용에 대한 인식 변화를 분석하였다. 이를 위하여 첫째, 기존의 테크놀로지 교수학적 내용지식(Technological Pedagogical Content Knowledge: TPACK) 함양 교사 교육 모델 및 VR/AR 콘텐츠 활용과 관련된 선행연구를 탐색하여 VR/AR-TPACK 함양을 위한 교사 교육 모델과 각 단계의 주요 원리를 도출하였다. 개발된 교사 교육 모델은 '탐색/경험'-'맵핑'-'협력적 설계'-'실행'-'성찰 및 개선' 총 5단계로 구성되었다. 둘째, 개발된 모델의 단계와 원리의 적절성을 탐색하기 위해 25명의 초등 예비 교사가 수강하는 교육대학교 정규 강좌에 적용하였다. 수업 전후 VR/AR 활용에 대한 인식 조사 설문 결과, 예비 교사들이 작성한 그룹별 수업지도안, 교사 교육 모델에 대한 예비교사들의 의견 및 피드백 내용, 교수자/연구자가 작성한 연구 일지를 연구 자료로 수집하였다. 초등 예비 교사들이 작성한 교사 교육 모델에 대한 의견과 연구 참여 전후 인식 조사 설문 내용은 개방 코딩과 범주화 과정을 통해 분석되었다. 연구 결과, 초등 예비 교사들은 교사 교육 모델의 각 단계에서 이루어진 활동과 경험에 대해 대부분 긍정적인 의견을 제시하였다. VR/AR 콘텐츠 활용에 관한 인식은 세 가지 측면에서 변화를 보였다. 첫째, VR/AR 콘텐츠에 대한 막연한 긍정적 인식이 구체적인 교육적 어포던스에 기반한 긍정적 인식으로 변화하였다. 둘째, VR/AR 콘텐츠를 활용할 때 겪을 만한 문제 상황을 경험함으로써 이에 대한 대비가 필요함을 인식하였다. 셋째, VR/AR 콘텐츠를 교사가 활용할 수 있는 유용한 교수 자원으로 인식하게 되었다. 이러한 연구 결과에 기반하여 VR/ARTPACK 교사 교육 모델에 대한 시사점과 연구의 한계를 논의하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF