• 제목/요약/키워드: implant vertical position

검색결과 50건 처리시간 0.02초

임플란트 치료 전 CBCT 영상분석 세 증례 (CBCT analysis of three implant cases for treatment planning)

  • 김재덕;김광원;임성훈
    • Imaging Science in Dentistry
    • /
    • 제37권3호
    • /
    • pp.171-180
    • /
    • 2007
  • The role of radiographic imaging in determining the size, numbers and the position of implants is very important. To perform the implant procedure, the dentist needs to evaluate the bone pathology and bone density, and to know the precise height, width, and contour of the alveolar process, as well as its relationship to the maxillary sinus and mandibular canal. The author analyzed 3 implant cases for treatment planning with the cone beam CT. All axial, panoramic, serial and buccolingual-sectioned images of 3 cases with stent including vertical marker were taken by using Mercuray (Hitachi, Japan). When the curved line drawn intentionally did not include dot image of a vertical marker on the axial image of CBCT, the image of the vertical marker was deformed on its buccolingually sectioned image. There was wide discrepancy in inclination between the alveolar bone and tooth on buccolingually sectioned image.

  • PDF

치조골 폭경과 임플랜트 고정체의 직경에 따른 지지조직의 응력분포 (STRESS ANALYSIS OF SUPPORTING TISSUES ACCORDING TO IMPLANT FIXTURE DIAMETER AND RESIDUAL ALVEOLAR BONE WIDTH)

  • 한상운;방몽숙;양홍서;박상원;박하옥;임현필
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.506-521
    • /
    • 2007
  • Statement of problem: The cumulative success rate of wide implant is still controversial. Some previous reports have shown high success rate, and some other reports shown high failure rate. Purpose: The aim of this study was to analyze, and compare the biomechanics in wide implant system embeded in different width of crestal bone under different occlusal forces by finite element approach. Material and methods: Three-dimensional finite element models were created based on tracing of CT image of second premolar section of mandible with one implant embedded. One standard model (6mm-crestal bone width, 4.0mm implant diameter central position) was created. Varied crestal dimension(4, 6, 8 mm), different diameter of implants(3.3, 4.0, 5.5, 6.0mm), and buccal position implant models were generated. A 100-N vertical(L1) and 30 degree oblique load from lingual(L2) and buccal(L3) direction were applied to the occlusal surface of the crown. The analysis was performed for each load by means of the ANSYS V.9.0 program. Conclusion: 1. In all cases, maximum equivalent stress that applied $30^{\circ}$ oblique load around the alveolar bone crest was larger than that of the vertical load. Especially the equivalent stress that loaded obliquely in buccal side was larger. 2. In study of implant fixture diameter, stress around alveolar bone was decreased with the increase of implant diameter. In the vertical load, as the diameter of implant increased the equivalent stress decreased, but equivalent stress increased in case of the wide implant that have a little cortical bone in the buccal side. In the lateral oblique loading condition, the diameter of implant increased the equivalent stress decreased, but in the buccal oblique load, there was not significant difference between the 5.5mm and 6.0mm as the wide diameter implant. 3. In study of alveolar bone width, equivalent stress was decreased with the increase of alveolar bone width. In the vertical and oblique loading condition, the width of alveolar bone increased 6.0mm the equivalent stress decreased. But in the oblique loading condition, there was not a difference equivalent stress at more than 6.0mm of alveolar bone width. 4. In study of insertion position of implant fixture, even though the insertion position of implant fixture move there was not a difference equivalent stress, but in the case of little cortical bone in the buccal side, value of the equivalent stress was most unfavorable. 5. In all cases, it showed high stress around the top of fixture that contact cortical bone, but there was not a portion on the bottom of fixture that concentrate highly stress and play the role of stress dispersion. These results demonstrated that obtaining the more contact from the bucco-lingual cortical bone by installing wide diameter implant plays an important role in biomechanics.

Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

  • Sabban, Hanadi;Mahdian, Mina;Dhingra, Ajay;Lurie, Alan G.;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.73-80
    • /
    • 2015
  • Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.

서지컬 가이드를 이용한 하악 임플란트 피개의치 수복 증례 (Oral rehabilitation of edentulous patient with mandibular implant overdenture using surgical guide)

  • 이동환;류재준
    • 대한치과보철학회지
    • /
    • 제60권4호
    • /
    • pp.339-346
    • /
    • 2022
  • 전통적인 총의치와 비교했을 때 하악 임플란트 피개의치는 2개의 임플란트로도 좋은 지지와 유지를 얻을 수 있다는 장점이 있다. 2개의 임플란트를 이용하여 하악 임플란트 피개의치를 제작할 때는 정확한 위치에 임플란트를 식립하는 것이 중요하다. 2개의 임플란트를 교합평면에 수직 방향으로, 견치 자리에 서로 평행하게 식립해야 피개의치의 장기적인 예후에 좋다. 하지만 무치악 환자에서 2개의 임플란트를 올바른 위치에 식립하는 것은 어려운 일이며, 이 때 서지컬 가이드를 이용한다면 보철적으로 유리한 위치에 임플란트를 식립하는데 도움을 받을 수 있다. 본 증례는 57세 남환으로 치주질환으로 인해 상, 하악의 모든 치아가 발거된 상태로 본원에 내원했다. 이에 상악은 전통적인 총의치, 하악은 2개의 임플란트를 이용한 임플란트 피개의치로 수복하여 기능 및 심미적으로 만족스러운 결과를 얻었으므로 이를 보고하고자 한다.

시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례 (Prosthetic restorations with cementless screw-retained implant systems: a case report)

  • 정영해;김임선
    • 대한치과기공학회지
    • /
    • 제45권4호
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.

A two-short-implant-supported molar restoration in atrophic posterior maxilla: A finite element analysis

  • Song, Ho-Yong;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.304-312
    • /
    • 2016
  • PURPOSE. The aim of this study was to investigate the stress distribution of 2-short implants (2SIs) installed in a severely atrophic maxillary molar site. MATERIALS AND METHODS. Three different diameters of internal connection implants were modeled: narrow platform (NP), regular platform (RP), and wide platform (WP). The maxillary first molars were restored with one implant or two short implants. Three 2SI models (NP-oblique, NP-vertical, and NP-horizontal) and four single implant models (RP and WP in a centered or cantilevered position) were used. Axial and oblique loadings were applied on the occlusal surface of the crown. The von Mises stress values were measured at the bone-implant, peri-implant bone, and implant/abutment complex. RESULTS. The highest stress distribution at the bone-implant interface and the peri-implant bone was noticed in the RP group, and the lowest stress distribution was observed in the 2SI groups. Cantilevered position showed unfavorable stress distribution with axial loading. 2SI types did not affect the stress distribution in oblique loading. The number and installation positions of the implant, rather than the bone level, influenced the stress distribution of 2SIs. The implant/abutment complex of WP presented the highest stress concentration while that of 2SIs showed the lowest stress concentration. CONCLUSION. 2SIs may be useful for achieving stable stress distribution on the surrounding bone and implant-abutment complex in the atrophic posterior maxilla.

하악구치부 피질골 engagement가 임플란트 하중전달에 미치는 영향에 관한 3차원 유한요소법적 응력분석 (THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE EFFECT OF CORTICAL ENGAGEMENT ON IMPLANT LOAD TRANSFER IN POSTERIOR MANDIBLE)

  • 정창모
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.607-619
    • /
    • 1999
  • Cortical support is an important factor, as the engagement of the fixture in strong compact bone offers an increased load-carrying capacity and initial stability. Because of the poor bone quality in the posterior mandible and other anatomic considerations, it has been suggested that implant fixtures be placed in these locations with apical engagement of the lingual cortical plate for so-called bicortication. The purpose of this investigation was to determine the effect of cortical engagements and in addition polyoxymethylene(POM) intramobile connector(IMC) of IMZ implant on implant load transfer in edentulous posterior segment of mandible, using three-dimensional (3D) finite element analysis models composed of cortical and trabecular bone involving single implant. Variables such as (1) the crestal peri-implant defect, (2) the apical engagement of lingual cortical plate, (3) the occlusal contact position (a vertical load at central fossa or buccal cusp tip), and (4) POM IMC were investigated. Stress patterns were compared and interfacial stresses along the bone-implant interface were monitored specially. Within the scope of this study, the following observations were made. 1) Offset load and angulation of fixture led to increase the local interfacial stresses. 2) Stresses were concentrated toward the cortical bones, but the crestal peri-implant defect increased the interfacial stresses in trabecular bone. 3) For the model with bicortication, it was noticed that the crestal cortical bone provided more resistance to the bending moment and the lingual cortical plate provided more support for the vertical load. But Angulation problem of the fixture from the lingual cortical engagement caused the local interfacial stress concentrations. 4) It was not clear that POM IMC had the effect on stress distribution under the present experimental conditions, especially for the cases of crestal peri-implant defect.

  • PDF

Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

  • Kim, Sung-Jun;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.388-394
    • /
    • 2018
  • PURPOSE. To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS. Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at $10N{\cdot}cm$, simulating hand tightening, and then at the manufacturers' recommended torque ($30N{\cdot}cm$) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS. Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION. Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening.

과도한 치아 마모와 다수의 치아 상실을 보이는 환자에서 computer tomography guided implant surgery와 수직고경 회복을 동반한 완전 구강 회복 증례 (Full-mouth rehabilitation with vertical dimension increase and computer tomography guided implant surgery in patient with excessive worn dentition and multiple loss of tooth)

  • 이경섭;임영준;권호범;김명주
    • 대한치과보철학회지
    • /
    • 제57권1호
    • /
    • pp.66-74
    • /
    • 2019
  • 과도한 마모는 치료받지 않을 시 여러 문제점들을 야기시킬 수 있기 때문에, 정확한 분석 및 진단을 바탕으로 예지성 있는 치료계획을 수립하도록 노력해야 하고, 수직고경에 대한 평가 및 그에 따른 단계적인 치료를 통해 안정된 악간 관계를 회복시켜 주어야 한다. 또한 임플란트 치료의 장기적인 성공을 위해서는 이상적인 위치와 각도로 임플란트를 식립하는 것이 중요하며, 다수의 임플란트 치료에서는 그 중요성이 더욱 증가한다. 따라서 철저한 계획 및 진단에 따른 정확한 수술과 보철 과정이 중요하다. 본 증례에서는 다수의 치아 상실 및 전반적인 치아 마모로 인해 수직고경이 상실되어 있는 68세의 남자 환자에게 치료 전 단계에서부터 다양하고 체계적인 분석을 통해 수직고경을 회복하는 치료 계획을 세웠다. 콘빔컴퓨터단층촬영 데이터를 활용하여 새로 설정한 수직고경에 맞춰 가이드 수술을 시행하였고, 임플란트를 포함한 전악 고정성 보철 수복을 통해 기능 및 심미적으로 환자와 술자 모두 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

Implant-assisted Removable Prosthetic Rehabilitation of a Patient with Crossed Occlusion

  • Oh, Hyun-Su;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • Journal of Korean Dental Science
    • /
    • 제14권1호
    • /
    • pp.32-39
    • /
    • 2021
  • 'Crossed occlusion' is the condition in which occlusal intercuspation is lost when several teeth on upper and lower jaw remain. This report describes a clinical case in which a patient had two upper-left posterior teeth and two lower-right posterior teeth; typically known as left-right crossed occlusion. Considering the patient's general condition and financial situation, the treatment plan included placement of two implants on each jaw against the remaining teeth using surgical guide. To find out the ideal position of implants, digital diagnostic wax-up was preceded by superimposing the cast and cone beam computed tomography image, which was aided with radiographic stents. The consequent surveyed implant bridge provided stable vertical stop for fabrication of the implant assisted removable partial dentures. The patient was satisfied with the functionality and esthetics of definitive prosthesis.