• Title/Summary/Keyword: implant type

Search Result 807, Processing Time 0.028 seconds

The Distribution of Implant Patients and the Type of Implant Site (임플란트 환자의 분포 및 식립부 유형)

  • Park, Ji-Eun;Yun, Jeong-Ho;Jung, Ui-Won;Kim, Chang-Seong;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.4
    • /
    • pp.819-836
    • /
    • 2004
  • Nowdays, the awareness of implant treatment has grown rapidly among dentists and patients alike in Korea, as it becomes a widely accepted treatment. The reason is that unlike crown and bridge or denture treatment, implant treatment helps preserve existing bone and improve masticatory functions. So, It is needed understanding about the type, distribution of implant patient. The following results on patient type and implant distribution were compiled from 4433 implant cases of 1596 patients treated at the periodontal dept. of Y University Hospital during 1992 to 2004. 1. There are no dissimilarities between men and women, with patients in their 40, 50s accounting for 52.5% of patients and 57.5% of implant treatments; the largest share of patients and implant treatments. 2. Mn. posterior area accounted for 54.9% of implant treatments followed by Mx. posterior area(27.6%), Mx anterior area(11.9%) and Mn anterior area(5.6%). 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 97.5% and fully edentulous patient accounted for the remaining 2.5%. 4. The major cause of tooth loss is periodontal disease, followed by dental caries, trauma and congenital missing. Also, older people are more likely to suffer from tooth loss due to periodontal disease rather than dental caries. 5. In the distribution of bone quality for maxillae, type III was most, followed by type II, r type IV and r type I. As for mandible, type II was most, followed by type III, type IV and for type I. 6. In the distribution of bone quantity for maxillae, type C was most, followed by type B, type D, type A, and for type E. As for mandible, type B was 52% most, followed by type C, type D, type A and type E. 7. The majority of implants were those of 1O-14mm in length (85.2%) and regular diameter in width (64%). The results provided us with basic data on patient type, implant distribution, bone condition, etc. We wish that our results coupled with other research data helps assist in the further study for better implant success/survival rates, etc.

A Retrospective study of the type of patients, the distribution of implant and the survival rate of $Xive^{(R)}$ implant (($Xive^{(R)}$)임플란트 식립시 환자 유형 및 식립부 분포와 생존율에 대한 후향적 연구)

  • Myung, Woo-Chun;Lee, Jung-Seok;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.523-534
    • /
    • 2007
  • This study is an analysis of types of patients and distribution of implant site and survival rate of $Xive^{(R)}$ implant. The following results on patient type, implant distribution and survival rate were compiled from 324 implant cases of 140 patients treated at the periodontal dept. of Yonsei University Hospital and G dental clinic between February 2003 and April 2006. 1. There are no dissimilarities between men and women, with patients in their 30, 40, 50s accounting for 80% of patients and accounted for 82% of implant treatments; the largest share of patients and implant treatments. 2. Mn, posterior area. accounted for 57% of implant treatments followed by Mx. posterior area(29%), Mx, anterior area(8%) and Mn, anterior area(6%). 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 96% and fully edentulous patient accounted for the remaining 4%. 4. The major cause of tooth loss is periodontal disease, followed by dental canes, trauma and congenital missing. 5, The distribution of bone quality for maxillae was 54,2% for type III, followed by 30.8% for type II, 15% for type IV and 0% for type I. As for mandible, the distribution was 63% for type II, followed by 34% for type III, 2,5% for type I and 0,5% for type IV. 6. The distribution of bone quantity for maxillae was 55% for type C, followed by 35% for type B, 8% for type D and 2% for type A. As for mandible, the distribution was 60% for type B, followed by 32% for type C, 7% for type A and 0% for type D. 7. The majority of implants were those of 9.5-13 mm in length(95%) and regular diameter in width(82%). 8. The total survival rate was 98%. The survival rate was 97% in the maxillae region and 99% in the mandible region. 9. The survival rate in type I was 83%, in type II was 99%, in type III was 97% and in type IV was 100%. As for the bone quantity, the survival rate in type A and D(100%) was most, followed by type B(99%) and type C(96%). The results showed that $Xive^{(R)}$ implant could be used satisfactorily compare for the other implant system. But we most to approach carefully in certain extreme condition especially with poor bone quality and quantity.

The Study of Implant Patient's Type and Implant Distribution (임플란트 환자의 유형 및 분포에 대한 연구)

  • Hong, Sung-Jae;Paik, Jeong-Won;Kim, Chang-Sung;Choi, Seong-Ho;Lee, Keun-Woo;Chai, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.539-554
    • /
    • 2002
  • It has been approximately 40 years since $Br{{\aa}}nemark$ first introduced osseo-integration for implants in the early 1960s. Unlike crown and bridge or denture treatment, implant treatment helps preserve existing bone and improve masticatory functions. Thus, the awareness of implant treatment has grown rapidly among dentists and patients alike in Korea, as it becomes a widely accepted treatment. The following results on patients type and implant distribution were compiled from 1814 implant cases of 640 patients treated at the periodontal dept. of Y University Hospital during 1992 to 2001. 1. There are no dissimilarities between men and women, with patients in their 40,50s accounting for 49% of patients and 56% of implant treatments; the largest share of patients and implant treatments. 2. Mn. posterior area accounted for 59% of implant treatments followed by Mx. posterior area(21%), Mx anterior area(l4%) and Mn anterior area 2%. 3. Partial edentulous patients treated by single crown and bridge-type prosthesis accounted for 98% and fully edentulous patient accounted for the remaining 2% 4. The major cause of tooth loss is periodontal disease, followed by dental caries, trauma and congenital missing. Compared to women, men are more likely to suffer from tooth loss due to periodontal disease. Also, older people are more likely to suffer from tooth loss due to periodontal disease rather than dental caries. 5. The distribution of bone quality for maxillae was 52% for type III, followed by 23% for type II, 20% for type IV and 0% for type I. As for mandible, the distribution was 52% for type II, followed by 37% for type III, 7% for type IV and 4% for type I. 6. The distribution of bone quantity for maxillae was 49% for type C, followed by 34% for type B, 14% for type D, 3% for type A, and 0% for type E. As for mandible, the distribution was 52% for type B, followed by 35% for type C, 6% for type D, 3% for type A and 0% for type E. 7. The majority of implants were those of 10-14mm in length (80%) and regular diameter in width (79%). The results provided us with basic data on patient type, implant distribution, bone condition, etc. We wish that our results coupled with other research data helps assist in the further study for better implant success/survival rates, etc.

Comparison of initial implant stability measured by Resonance Frequency Analysis between different implant systems (Resonance Frequency Analysis(RFA)를 이용한 임플란트 종류간의 초기 안정성 비교)

  • Oh, Jun-Ho;Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.529-534
    • /
    • 2008
  • Purpose: The objective of this study was to compare initial implant stability measured by RFA between different implant systems during the initial healing period. Material and Methods: Fifty-four patients (36 males/18 females) who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital during the period between January and November in 2007 were included in the study. The mean age of the subjects was 49 years old (18 to 77). A total of 104 implants (Type A: 3i $Osseotite^{(R)}$, Type B: $Replace^{(R)}$ select, Type C: ITI implant) were placed following the manufacturer's standard surgical protocols. Implant stability quotient (ISQ) readings were obtained for each implant at the time of surgery, 2-, and 4-month postoperatively. Result: No implant was failed during the observation period. At the baseline, the difference between mean ISQ values of 3 implant systems was statistically significant (p<0.05). However, at 2-, and 4-month following implant surgery, no significant difference was observed between ISQ values of the implant systems. In the same implant, the ISQ values of Type B and C implants increased (p<0.05), but those of Type A implants decreased during the 2-month healing period. The mean ISQ values of Type B and C implants showed a increasing tendency, while those of Type A implants were stable for the 4-month follow-up period. Conclusion: Within limits of this study, it can be concluded that implant design and surface topography of implant might influence the ISQ value and changing pattern during the initial healing period.

EFFECT OF IMPLANT DESIGNS ON INSERTION TORQUE AND IMPLANT STABILITY QUOTIENT (ISQ) VALUE

  • Piao Chun-Mei;Heo Seong-Joo;Koak Jai-Young;Kim Seong-Kyun;Han Chong-Hyun;Fang Xian-Hao
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.325-332
    • /
    • 2006
  • Statement of problem. Primary implant stability has long been identified as a prerequisite to achieve osseointegration. So the application of a simple, clinically applicable noninvasive test to assess implant stability and osseiointegratation are considered highly desirable. Purpose. The purpose of this study was to evaluate the ISQ value and the insertion torque of the 3 different implant system, then to evaluate whether there was a correlation between ISQ value and insertion torque; and to determine whether implant design has an influence on either insertion torque or ISQ value. Material and method. The experiment was composed of 3 groups: depending on the implant fixture design. Group1 was Branemark type parallel implant in $3.75{\times}7mm$. Group2 was Oneplant type straight implant in $4.3{\times}8.5mm$. Group3 was Oneplant type tapered implant in $4.3{\times}8.5mm$. Depending on the density of the bone, 2 types of bone were used in this experiment. Type I bone represented for cortical bone, type II bone represented for cancellous bone. With the insertion of the implant in type I and type II bone, the insertion torque was measured, then the ISQ value was evaluated, and then the correlation between insertion torque and ISQ value was analyzed Result and conclusion. Within the limitations of this study, the following conclusions were drawn. 1. Within the 3 different implants, the insertion torque value and ISQ value were higher in type I bone, when compared with type II bone.(p<0.05) 2. In type I and type II bone, Oneplant type tapered implant has the highest value in insertion torque.(p<0.05) 3. In type I and type II bone, there was no difference in ISQ values among the 3 types of implant. (p>0.05) 4. Significant linear correlation was found in $Br{\aa}nemark$ type parallel implant: $3.75{\times}7mm$ in type II bone.

A THREE DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS OF IMPLANT-SUPPORTED MANDIBULAR OVERDENTURE ACCORDING TO IMPLANT NUMBER AND ATTACHMENT TYPE (임플란트의 수와 어태치먼트의 종류에 따른 하악 임플란트 지지 오버덴춰의 삼차원 광탄성 응력분석)

  • Han, Sang-Hoon;Tae, Yoon-Sup;Jin, Tae-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.577-608
    • /
    • 1997
  • The purpose of this study is to evaluate the stress distribution in the bone around dental implants supporting mandibular overdenture according to the number of implant and the type of attachment. Two or four implants were placed in an edentulous mandibular model and three dimensional photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure and also to calculate principal stress components at cervical area of each implant. The attachments tested were rigid and resilient type of Dolder bar, Round bar, Hader bar and Dal-Ro attchment. The results were as follows ; 1. In 2-implant supported overdenture using Round bar, Hader bar, and Dal-Ro attachment, compressive stress pattern was observed on the supporting structure of implant on loaded side, while tensile stress pattern in unloaded side. 2. In 2-implant supported overdenture using Dolder bar, the rigid Dolder bar shared the occlusal loads between 2 implants in a more favorable manner than was exhibited by the resilient type, while the resilient type placed a more stress on the distocervical area of the implant on the loaded side. But compressive stress pattern was observed in both the loaded and unloaded sides in either case. 3. In 2-implant supported overdenture, rigid and resilient type of Dolder bar exhibited more cross arch involvement than the Round bar, Hader bar, or Dal-Ro attachment. 4. In 4-implant supported overdenture using resilient Dolder bar and Hader bar, stress turned out to be distributed evenly among the implants between loaded and unloaded side, but thor was no reduction in the magnitude of the stress in the surrounding structure of implant contratry to 2-implant supported overdenture. 5. The stress pattern at cervical area of implant was different with the number of implant or the type of attachment but the overload, harmful to surrounding structure of implant, was not observed.

  • PDF

A comparative study of the distribution of implant fixtures according to length and diameter by retained type of implant-supported fixed prosthesis (임플란트 지지 고정성 치과 보철물 유지방식에 따른 고정체의 직경과 길이 분포 비교 연구)

  • Kim, Wook-Tae
    • Journal of Technologic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.347-353
    • /
    • 2006
  • The Purpose of this study was to compare the distribution of implant fixtures according to length and diameter between screw-retained and cement-retained implant-supported fixed prosthesis and to asses whether prosthesis retained types affected the selection of size of implant fixtures. This study presents a follow-up 2,416 implant-supported fixed type prosthesis that have been screw retained or cemented retained for about 10 years in 14 dental clinics. Included in the study were 458 men and 397 women and implant fixtures used in this study were screw retained type 1,057 and 1,359 of cemented retained type. The statistical results among the diameter types of fixture by prosthesis retained type was no significant difference noted (P= 0.809) and there was significant differences was enough to among the lengths of fixture by prosthesis retained type (P= 0.020). However there were no significant difference among the fixture diameter types and length by prosthesis retained type (P= 0.486). So there was not affected to prostheis fixation mechanism for the size of implant fixtures.

  • PDF

Non-submerged type implant stability analysis during initial healing period by resonance frequency analysis (Resonance frequency analysis를 이용한 non-submerged type 임플란트의 초기 안정성 분석)

  • Kim, Deug-Han;Pang, Eun-Kyoung;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.339-348
    • /
    • 2009
  • Purpose: The purpose of the present study was to analyze the implant stability quotient(ISQ) values for Korean non-submerged type implant and determine the factors that affect implant stability. Methods: A total of 49 Korean non-submerged type implants were installed in 24 patients, and their stability was measured by resonance frequency analysis(RFA) at the time of surgery, and 1, 2, 3, 4, 8, 12 weeks postoperatively. The data for implant site, age, sex, implant length and diameter, graft performing, bone type, and insertion torque were analyzed. Results: The lowest mean stability measurement was at 3 weeks. There was significant difference between implant placement and 12 weeks. There was significant difference between implant placement and 12 weeks in diameters of 4.1 mm and 4.8 mm. Also, there were significant differences between diameters of 4.1 mm and 4.8 mm at implant placement and 12 weeks after surgery. This result suggests that the factor related to implant diameter may affect the level of implant stability. No statistically significant relationship was found between the resonance frequency analysis and the variables of maxilla/mandible, sex, anterior/posterior, implant length, age of patient, graft performing, bone type, insertion torque during initial healing period. Conclusions: These findings suggest that the factor related to implant diameter may affect the variance of implant stability, and ISQ value of implant was stable enough for proved stability level during initial healing period.

STRESS ANALYSIS OF SUPPORTING TISSUES AND IMPLANTS ACCORDING TO IMPLANT FIXTURE SHAPES AND IMPLANT-ABUTMENT CONNECTIONS (임플랜트 고정체의 형태와 연결방식에 따른 임플랜트 및 지지조직의 응력분포)

  • Han Sang-Un;Park Ha-Ok;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.226-237
    • /
    • 2004
  • Purpose: Four finite element models were constructed in the mandible having a single implant fixture connected to the first premolar-shaped superstructure, in order to evaluate how the shape of the fixture and the implant-abutment connection would influence the stress level of the supporting tissues fixtures, and prosthethic components. Material and methods : The superstructures were constructed using UCLA type abutment, ADA type III gold alloy was used to fabricate a crown and then connected to the fixture with an abutment screw. The models BRA, END , FRI, ITI were constructed from the mandible implanted with Branemark, Endopore, Frialit-2, I.T.I. systems respectively. In each model, 150 N of vertical load was placed on the central pit of an occlusal plane and 150 N of $40^{\circ}$ oblique load was placed on the buccal cusp. The displacement and stress distribution in the supporting tissues and the other components were analysed using a 2-dimensional finite element analysis . The maximum stress in each reference area was compared. Results : 1. Under $40^{\circ}$ oblique loading, the maximum stress was larger in the implant, superstructure and supporting tissue, compared to the stress pattern under vertical loading. 2. In the implant, prosthesis and supporting tissue, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 3. In the superstructure and implant/abutment interface, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 4. In the implant fixture, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 5 The stress was more evenly distributed in the bone/implant interface through the FRI of trapezoidal step design. Especially Under $40^{\circ}$ oblique loading, The maximum stress was smallest in the bone/implant interface. 6. In the implant and superstructure and supporting tissue, the maximum stress occured at the crown loading point through the ITI. Conclusion: The stress distribution of the supporting tissue was affected by shape of a fixture and implant-abutment connection. The magnitude of maximum stress was reduced with the internal connection type (FRI) and the morse taper type (ITI) in the implant, prosthesis and supporting tissue. Trapezoidal step design of FRI showed evenly distributed the stress at the bone/implant interface.