• Title/Summary/Keyword: implant surgery

Search Result 1,675, Processing Time 0.09 seconds

A population-based study of breast implant illness

  • Magno-Padron, David A.;Luo, Jessica;Jessop, Terry C.;Garlick, Jared W.;Manum, Joanna S.;Carter, Gentry C.;Agarwal, Jayant P.;Kwok, Alvin C.
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.353-360
    • /
    • 2021
  • Background Despite evidence supporting the safety of breast implants, some women associate their implants with adverse health effects and have called this syndrome "breast implant illness." We sought to characterize breast implant illness symptoms and to report how implant removal affects their symptoms. Methods An anonymous 20 question survey was administered to the Facebook group: "UTAH Breast Implant Illness" to characterize the symptoms these women attributed to their breast implants. Several questions allowed us to evaluate how implant removal affected women's symptoms. Results Of the 182 respondents, 97% report that implants negatively affect their health and 95% identify these symptoms with breast implant illness. Ninety-six percent of respondents had implants placed for cosmetic reasons and 51% had silicone implants. The most common symptoms associated with breast implant illness are brain fog (95%), fatigue (92%), joint pain (80%), and hair loss (74%). Sixty percent of respondents learned about breast implant illness from family/friends and/or social media platforms (56%), 40% of respondents had their implants removed, and 97% report relief of their symptoms post-removal (23% complete, 74% partial). Following explantation, there was a significant improvement in all but one reported symptom. An association was found between the number of symptoms reported prior to explantation and the number of symptoms resolving following explantation. Conclusions Breast implant illness is a syndrome characterized by fatigue, decreased focus, hair loss, and joint pain after the placement of breast implants. Nearly all patients report improvement of symptoms after implant removal. Significant efforts should be made to better understand breast implant illness and its etiology.

A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template

  • Youk, Shin-Young;Lee, Jee-Ho;Park, Ji-Man;Heo, Seong-Joo;Roh, Hyun-Ki;Park, Eun-Jin;Shin, Im Hee
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.395-405
    • /
    • 2014
  • PURPOSE. This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS. A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computerguided template during the period of 2012 and 2013 in university hospitals, dental hospitals and dental clinics that practiced implant surgery using the computer-guided template. Likert scale and VAS score were used in the survey questions, and the independent t-test and One-Way ANOVA were performed (${\alpha}=.05$). RESULTS. The route that the subjects were introduced to the computer-guided implant surgery using a surgical template was mostly advices by dentists, and the most common reason for which they chose to undergo such surgery was that it was accurate and safe. Most of them gave an answer that they were willing to recommend it to others. The patients who have undergone the computer-guided implant surgery felt less pain during the operation and showed higher satisfaction than those who have undergone conventional implant surgery. Among the patients who have undergone computer-guided implant surgery, those who also had prior experience of surgery without a computer-guided template expressed higher satisfaction with the former (P<.05). CONCLUSION. In this study, it could be seen that the patients who have undergone computer-guided implant surgery employing a surgical template felt less pain and had higher satisfaction than those with the conventional one, and the dentist's description could provide the confidence about the safety of surgery.

The rate and stability of mandibular block bone graft in recent 5 years

  • Park, Jong-Cheol;Kim, Yun-Ho;Choi, Hong-Seok;Oh, Jong-Shik;Shin, Sang-Hun;Kim, Yong-Deok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.21.1-21.6
    • /
    • 2017
  • Background: The purposes of the present study were to compare implant stabilities of mandibular block bone graft and bovine bone graft and to evaluate influencing factors for implant stability in mandibular block bone (MBB) graft. Methods: This retrospective study investigated 1224 cases and 389 patients treated by one surgeon in the Department of Oral and Maxillofacial Surgery of Pusan National University Dental Hospital (Yangsan, Korea) between January 2010 and December 2014. Proportions that MBB graft cases constitute in all implant restoration cases and in all bone graft cases were measured. Implant stability quotient (ISQ) values were achieved by the same surgeon before loading. The average ISQ values of the experimental groups were compared. In addition, ISQ values of influencing factors, such as age, sex, implant size, and implant placement site, were compared within the MBB group using $Osstell^{TM}$ Mentor ($Osstell^{(R)}$, $G{\ddot{o}}teborg$, Sweden). Paired t test and ANOVA were conducted for statistical analysis with a significance level of 0.05. Results: Fifty-five percent of all implant restoration cases performed bone graft while MBB cases constituted 34% of all implant restoration cases and 61% of all bone graft cases. Comparing ISQ values according to bone graft materials, the MBB group manifested sufficient implant stability by presenting comparable ISQ value to that of the experimental group without bone graft. Among the reviewed factors, females, mandibular molar regions, and implants in larger diameter displayed greater implant stabilities. Conclusions: Satisfactory implant stability was accomplished upon administration of MBB graft. Within the limitation of this study, gender, implant site, and implant diameter were speculated to influence on implant stability in MBB graft.

Nontuberculous Mycobacterial Infection after Breast Reconstruction with an Implant: A Case Report (보형물을 이용한 유방재건 수술 후발생한비정형 마이코박테리아감염1례: 증례 보고)

  • Lee, Hyuck-Jae;Pyon, Jai-Kyong;Lim, So-Young;Mun, Goo-Hyun;Bang, Sa-Ik;Oh, Kap-Sung
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.519-522
    • /
    • 2011
  • Purpose: Breast implant surgery is increasing in Korea. NTM (non tuberculous mycobacteria) infection after breast implant surgery is rare, but it has been there reported in several foreign countries. However, no report has been issued on NTM infection after breast reconstruction surgery with an implant in Korea. The purpose of this article is to report a case of NTM infection after breast reconstruction surgery with an implant. Methods: A female patient who underwent total mastectomy and immediate breast reconstruction with a latissimus dorsi myocutaneous flap and an implant exhibited signs of inflammation after the surgery. Fluid cultures taken at the time of wound exploration were initially negative, but NTM was isolated by culture 10 days later. Results: The implant was removed. M. fortuitum was identified by acid-fast culture and NTM-PCR. The patient was treated with combined antibiotic therapy. Conclusion: Although it is difficult to diagnose NTM infection after breast surgery, it is important that surgeons include NTM infection in the differential diagnosis of a post mammoplasty infection after breast implant surgery.

Rupture and Intrapleural Migration of a Cohesive Silicone Gel Implant after Augmentation Mammoplasty: A Case Report (코헤시브 실리콘 젤 유방삽입물을 이용한 유방확대술 후 발생한 유방삽입물의 흉강내로의 이탈 및 파열 증례보고)

  • Lee, Jun-Yong;Kim, Han-Koo;Kim, Woo-Seob;Park, Bo-Young;Bae, Tae-Hui;Choe, Ju-Won
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.323-325
    • /
    • 2011
  • Purpose: Breast implant ruptures and displacement are problematic complications after augmentation mammoplasty. The authors report a patient whose cohesive silicone gel implant ruptured and migrated into the pleural cavity after augmentation mammoplasty. Methods: A 23-year-old female had received augmentation mammoplasty at a local clinic a week before visiting our hospital. When the patient's doctor performed a breast massage on the sixth postoperative day, the left breast became flattened. The doctor suspected a breast implant rupture and performed revision surgery. The implant, however, was not found in the submuscular pocket and no definite chest wall defect was found in the operative field. The doctor suspected implant migration into the pleural cavity, and after inserting a new breast implant, the doctor referred the patient to our hospital for further evaluation. The patient's vital signs were stable and she showed no specific symptoms except mild, intermittent pain in the left chest. A CT scan revealed the ruptured implant in the left pleural cavity and passive atelectasis. Results: The intrapleurally migrated ruptured implant was removed by video-assisted thoracic surgery (VATS). There were no adhesions but there was mild inflammation of the pleura. No definite laceration of the pleura was found. The patient was discharged on the first day after the operation without any complications. Conclusion: Surgeons should be aware that breast implants can rupture anytime and the injury to the chest wall, which may displace the breast implant into the pleural cavity, can happen during submuscular pocket dissection and implant insertion.

Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

  • Kim, Sung-Eun;Jung, Dong-Woo;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha;Lee, Soo Jung;Kang, Su Hwan;Choi, Jung Eun
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.529-534
    • /
    • 2014
  • Background In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. Methods From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. Results The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. Conclusions By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

Anterior implant case report using digital guided implant template (임플란트 가이드를 활용한 전치부 수복증례)

  • Kim, Taeeun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.41-50
    • /
    • 2018
  • Guided implant surgery is useful in anterior implant case in terms of fixture installation and temporary crown delivery. For the aesthetic prosthetics in anterior implant, the position of the implant fixture is crucial. Guided surgery is the top-down procedure and we designed prosthetics first and then determine the position of the fixture. Guided surgery can reduce the stress of dentist with difficult anterior implant case.

Functional Endoscopic Sinus Surgery for a Patient with Maxillary Sinusitis Occurring after Implant Placement

  • You, Jae-Seek;Kim, Su-Gwan;Oh, Ji-Su;Jeong, Gyeong-Dal;Mah, Deuk-Hyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.5
    • /
    • pp.331-336
    • /
    • 2013
  • Maxillary sinus membrane elevation and bone graft have been performed routinely in alveolar bone with insufficient residual bone height. There are a number of causes for development of maxillary sinusitis after these procedures. When maxillary sinusitis is caused by sinus membrane elevation, bone graft, and implant placement, various treatment such as medication, incision and drainage (I&D), implant removal, and the Caldwell-Luc procedure can be considered. Removal of an implant or the Caldwell-Luc procedure can be harmful if inflammation is not present in the oral cavity and survival of grafted bone and implant osseointegration can be expected despite the presence of maxillary sinusitis. In this case, functional endoscopic sinus surgery, which was often used in the otorhinolaryngology department, was performed without removal of the implant for a patient with maxillary sinusitis after one month following implant placement. Thus, we report on this case with a review of the literature.

An assessment of template-guided implant surgery in terms of accuracy and related factors

  • Lee, Jee-Ho;Park, Ji-Man;Kim, Soung-Min;Kim, Myung-Joo;Lee, Jong-Ho;Kim, Myung-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.440-447
    • /
    • 2013
  • PURPOSE. Template-guided implant therapy has developed hand-in-hand with computed tomography (CT) to improve the accuracy of implant surgery and future prosthodontic treatment. In our present study, the accuracy and causative factors for computer-assisted implant surgery were assessed to further validate the stable clinical application of this technique. MATERIALS AND METHODS. A total of 102 implants in 48 patients were included in this study. Implant surgery was performed with a stereolithographic template. Pre- and post-operative CTs were used to compare the planned and placed implants. Accuracy and related factors were statistically analyzed with the Spearman correlation method and the linear mixed model. Differences were considered to be statistically significant at $P{\leq}.05$. RESULTS. The mean errors of computer-assisted implant surgery were 1.09 mm at the coronal center, 1.56 mm at the apical center, and the axis deviation was $3.80^{\circ}$. The coronal and apical errors of the implants were found to be strongly correlated. The errors developed at the coronal center were magnified at the apical center by the fixture length. The case of anterior edentulous area and longer fixtures affected the accuracy of the implant template. CONCLUSION. The control of errors at the coronal center and stabilization of the anterior part of the template are needed for safe implant surgery and future prosthodontic treatment.

Mechanical irritation by protruding bone: A possible cause of breast implant rupture

  • Aitzetmuller, Matthias Michael;Haslhofer, David Johannes;Wenny, Raphael;Schmidt, Manfred;Duscher, Dominik;Huemer, Georg Michael
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.470-473
    • /
    • 2018
  • Although breast implants have been in clinical use for almost 6 decades and have undergone considerable development during this time, implant rupture is still a dreaded long-term complication. Some obvious external factors, such as trauma, can lead to implant rupture, but many studies have reported a high rate of "spontaneous" implant rupture. Herein, we present two cases with the aim of raising awareness of a new possible cause of "spontaneous" implant rupture: mechanical irritation by bony protrusions.