• Title/Summary/Keyword: implant supported dental prosthesis

검색결과 150건 처리시간 0.232초

임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구 (An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level)

  • 신동환;조규성;박광호;문익상
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

치과용 주조 합금의 방전가공에 따른 표면 성분 변화 (Elemental alteration of the surface of dental casting alloys induced by electro discharge machining)

  • 장용철;이명곤
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.55-61
    • /
    • 2009
  • Passive fitting of meso-structure and super-structures is a predominant requirement for the longevity and clinical success of osseointegrated dental implants. However, precision and passive fitting has been unpredictable with conventional methods of casting as well as for corrective techniques. Alternative to conventional techniques, electro discharge machining(EDM) is an advanced method introduced to dental technology to improve the passive fitting of implant prosthesis. In this technique material is removed by melting and vaporization in electric sparks. Regarding the efficacy of EDM, the application of this technique induces severe surface morphological and elemental alterations due to the high temperatures developed during machining, which vary between $10,000{\sim}20,000^{\circ}C$. The aim of this study was to investigate the morphological and elemental alterations induced by EDM process of casting dental gold alloy and non-precious alloy used for the production of implant-supported prosthesis. A conventional clinical dental casting alloys were used for experimental specimens patterns, which were divided in three groups, high fineness gold alloy(Au 75%, HG group), low fineness gold alloy(Au 55%, LG group) and nonprecious metal alloy(Ni-Cr, NP group). The UCLA type plastic abutment patterns were invested with conventional investment material and were cast in a centrifugal casting machine. Castings were sandblasted with $50{\mu}m\;Al_2O_3$. One casting specimen of each group was polished by conventional finishing(HGCON, LGCON, NPCON) and one specimen of each group was subjected to EDM in a system using Cu electrodes, kerosene as dielectric fluid in 10 min for gold alloy and 20 min for Ni-Cr alloy(HGEDM. LGEDM, NOEDM). The surface morphology of all specimens was studied under an energy dispersive X-ray spectrometer (EDS). The quantitative results from EDS analysis are presented on the HGEDM and LGEDM specimens a significant increase in C and Cu concentrations was found after EDM finishing. The different result was documented for C on the NPEDM with a significant uptake of O after EDM finishing, whereas Al, Si showed a significant decrease in their concentrations. EDS analysis showed a serious uptake of C and Cu after the EDM procedure in the alloys studied. The C uptake after the EDM process is a common finding and it is attributed to the decomposition of the dielectric fluid in the plasma column, probably due to the development of extremely high temperatures. The Cu uptake is readily explained from the decomposition of Cu electrodes, something which is also a common finding after the EDM procedure. However, all the aforementioned mechanisms require further research. The clinical implication of these findings is related with the biological and corrosion resistance of surfaces prepared by the EDM process.

  • PDF

만성 치주염 환자에서 다수치 발거 후 디지털 임시 즉시 의치 제작 및 임플란트 지지 가철성 국소의치 수복 증례 (Digital interim immediate denture fabrication and implant-supported removable partial denture fabrication after multiple teeth extraction in patient with chronic periodontitis: a case report)

  • 박민재;방지원;방주혁;임선영;이용상;이근우;김성용
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.104-112
    • /
    • 2024
  • 다수 치아를 발치하면 환자는 사회적, 심리적, 심미적인 문제를 마주하게 된다. 이때, 치아를 발치하기 전 임시 즉시 의치를 제작하는 것을 통해 이러한 문제를 최소화할 수 있다. 특히, 디지털 기술을 활용해 임시 즉시 의치를 제작한다면 기공과정이 단순해 지고 환자의 적은 내원 횟수로 임시 즉시 의치를 완성할 수 있다. 한편, 소수의 잔존치가 남은 환자에서 고정성 임플란트 보철수복이 어렵고, 가철성 국소의치의 지지 및 유지가 불량할 것으로 예상되는 경우에 임플란트 지지 가철성 국소의치(Implant-supported removable partial denture)가 대체 치료 옵션으로 주목되며, 임플란트 보철물을 이용해 추가적인 지지 및 유지가 가능하다. 본 증례에서는 다수치아 발거 후 소수 잔존치 상황에서 디지털 기술을 활용해 임시 즉시 의치를 제작하였다. 이후 임플란트를 식립하고 서베이드 크라운을 제작해 가철성 국소의치의 지지, 안정, 유지를 제공하여 임상적으로 만족스러운 결과를 얻었기에 이를 보고하고자 한다.

임플란트 주위염이 발생한 고정성보철 환자에 상악 Milled-bar와 부착장치를 이용한 피개의치로 수복한 증례 (Rehabilitation using milled-bar with attachment maxilla overdenture in a patient with peri-implantitis fixed prosthesis: A case report)

  • 이준명;김소연;이두형;이규복;이청희
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.123-130
    • /
    • 2024
  • 완전 무치악 환자의 보철 수복에는 다양한 방법이 있지만, 환자의 개별적인 상황과 요구사항에 따라 적절한 방법을 선택하는 것이 중요하다. 가철성 총의치는 비교적 경제적인 장점이 있지만, 불편한 착용감과 낮은 저작효율이 문제가 될 수 있다. 반면 임플란트를 이용한 고정성 보철물은 안정성이 높지만 다수의 임플란트가 필요하고 수술적인 위험이 있으며 경제적인 부담이 크다는 단점이 있다. 임플란트 보철학이 도입되면서 임플란트를 이용한 임플란트 지지 국소의치, 피개의치 등 다양한 선택이 가능해졌다. 잔존 치조골이 충분한 경우 임플란트를 이용한 고정성 보철물이 가장 효과적인 선택일 수 있다. 하지만 잔존 치조골이 부족하여 임플란트 식립이 불가능하거나 경제적인 여유가 없는 경우에 소수의 임플란트를 이용한 피개의치는 임플란트를 통해 지지를 얻고 부가적인 부착장치로 유지를 얻을 수 있으며 의치로 안모를 회복하는데 적합할 수 있다. 본 증례는 하악 양쪽 구치부 임플란트 통증 및 저작시 불편감으로 내원하였으며, 심한 임플란트 주위염으로 다수의 임플란트를 발거 후 상악은 양쪽 구치부에 임플란트를 재식립하여 milled-bar에 부착장치로 유지력을 얻은 피개의치를 제작하였고, 하악은 임플란트를 추가 식립 후 고정성 보철물을 이용하여 수복하였다. 치료가 완료된 후 10개월간 경과관찰 결과 의치의 파절, 유지력 상실 등 임상적으로 이상이 없었으며 방사선학적으로도 초진시와 유사한 골 소실상태를 보였다. 또한 구강위생이 잘 유지되었고 환자도 심미적 기능적 결과에 만족하였다.

치과의료관광에 대한 인식과 활성화 방안 (Awareness and activation towards dental medical tourism)

  • 최유리;장선옥;조윤정;심연수
    • 한국치위생학회지
    • /
    • 제15권5호
    • /
    • pp.857-863
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate the awareness and activation towards dental medical tourism. Methods: A self-reported questionnaire was completed by 195 dental hygienists in Seoul from January 30 to September 15, 2014. Data were analyzed by one way ANOVA, chi square and t test using SPSS 19.0 program. the questionnaire consisted of general characteristics of the subjects, awareness towards medical tourism, medical tourism related hospitals, activation of Korean medical tourism, fields of medical tourism, and improvement of medical tourism. The questionnaire was adapted and modified from Kim and Kim by Likert scale. Results: Dental hygienists gave the high perception and possibility towards medical tourism (94.1%). Those carrying out medical tourism accounted for 39.5 percent. The most difficult problem was communication with foreigners (80.5%). The performance of prosthesis and anesthesia was the most specialized area that supported the medical tourism (84.1%). In order to improve the medical tourism implementation, dental medical technology must be strengthened (39.8%). Conclusion: The desirable dental medical tourism must be carried out by proficient dental medical manpower, higher technology, active participation and financial support by the government. This dental medical tourism will provide job opening for the dental hygienists.

양측성 단일 임플란트 지지 서베이드 크라운을 이용한 하악 임플 란트 보조 국소의치 수복 증례 (Implant assisted removable partial denture using bilateral single implant-supported surveyed crown: a case report)

  • 최서준;문홍석;김재영
    • 대한치과보철학회지
    • /
    • 제62권2호
    • /
    • pp.146-156
    • /
    • 2024
  • 임플란트 보조 국소의치의 치료는 오래전부터 여러 형태로 시도되어 왔으며, 이 중 임플란트 서베이드 크라운 국소의치의 경우 점차 예지성을 얻고 있으며, 특히 경제적, 해부학적으로 불리한 부분 무치악 환자에게 한 가지 치료 방법이 될 수 있다. 이때 임플란트의 식립 위치는 치료 목적에 따라 전방 식립과 후방 식립으로 분류될 수 있는데, 이는 환자의 치조제, 잔존치 예후, 대합치 등 여러 상황을 고려하여 결정되어야 한다. 본 증례에서는 하악 Kennedy 1급 부분 무치악 환자에게 두 개의 임플란트 서베이드 크라운을 활용한 하악 임플란트 보조 국소의치를 통해 수복하였다. 본 환자에게 후방 식립이 어렵다는 점과 잔존치의 예후를 고려하여 임플란트를 잔존치에 근접한 부위에 두 개를 식립하는 것이 계획되었으며, 가이드 수술을 통해 계획한 위치, 각도, 깊이에 식립되었다. 고정성 보철물 제작 과정은 상악 무치악 치아 배열 과정과 병행하여 예지성을 높였고, 국소의치를 제작 시에는 임플란트가 최후방 지대치로서 과도한 하중이 가하지 않도록 기능 운동을 허용하는 형태로 디자인되고, 이차 인상 과정을 거쳐 제작되었다. 각 치료 과정을 계획한대로 진행하여 환자와 술자 모두 심미적, 기능적으로 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

THE EFFECT OF ABUTMENT HEIGHT ON SCREW LOOSENING IN SINGLE IMPLANT-SUPPORTED PROSTHESES AFTER DYNAMIC CYCLIC LOADING

  • Kim Nam-Gun;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.664-670
    • /
    • 2004
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection. Purpose. The purpose of this study was to examine the changes of detorque values of abutment screws with external connection in different abutment heights. Materials and methods. After cyclic loading on three different abutment heights, detorque values were measured. Abutments were retained with titanium abutment screws tightened to 30 Ncm (30.5 kgmm) with digital torque gauge as recommended by the manufacturer. Replacing abutments, implants and titanium abutment screws with new ones at every measurement, initial detorque values were measured six times. In measuring de torque values after cyclic loading, Avana Cemented Abutments of 4.0 mm collar, 7.0 mm height (Osstem Co., Ltd., Seoul, Korea) were used with three different lengths of 5.0, 8.0, 11.0 mm. Shorter abutments were made by milling of 11.0 mm abutment to have the same force-exercised area of 4.5 mm diameter. Sine curve force (20N-320N, 14Hz) was applied, and detorque values were measured after cyclic loading of 2 million times by loading machine. Detorque values of initial and after-loading were measured by digital torque gauge. One-way ANOVA was employed to see if there was any influence from different abutment heights. Results. The results were as follows: 1. The initial detorque value was 27.8$\pm$0.93 kgmm, and the ratio of the initial detorque value to the tightening torque was 0.91(27.8/30.5). 2. Measured detorque values after cyclic loading were declined as the height of the abutment increased, that was, 5.0 mm; 22.3$\pm$0.82 kgmm, 8.0 mm; 21.8$\pm$0.93 kgmm, and 11.0 mm; 21.3$\pm$0.94 kgmm. 3. One-way ANOVA showed no statistically significant differences among these (p>0.05). 4. Noticeable mobility at the implant-abutment interface was not observed in any case after cyclic loading at all.

임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO PLATFORM WIDTH OF FIXTURE)

  • 정경민;정재헌;정승미
    • 대한치과보철학회지
    • /
    • 제41권5호
    • /
    • pp.674-688
    • /
    • 2003
  • Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.

심한 치조골 소실이 있는 상악 무치악 환자에서 Pekkton telescopic attachment를 이용한 임플란트 피개의치 증례 (A case of maxilla implant overdenture using Pekkton telescopic attachment with severe alveolar bone resorption)

  • 박하은;이원섭;이철원;이수영
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.189-194
    • /
    • 2019
  • 심한 치조골 흡수를 동반한 편악 무치악 환자의 보철 수복시 대합치열의 상태를 고려하여 올바른 교합평면을 설정하고, 교합력이 균일하게 분산될 수 있는 치료가 제공되어야 한다. 임플란트 유지 피개의치는 소수의 임플란트로 치조골 흡수가 심한 완전 무치악 환자에게 총의치보다 우수한 유지와 안정성을 주는 치료이다. 최근 치과 영역에서 소개된 신소재 polyaryletherketone (PAEK) 기반의 폴리머(Pekkton ivory, Cendres + $M{\acute{e}}taux$ SA, Biel / Bienne, Switzerland)를 사용한 telescopic 어태치먼트는 전형적인 telescopic 코핑의 이점을 가지며, 내마모성이 뛰어나며, 기존의 임플란트 피개의치에 비해 가볍고 경제적인 장점이 있다. 본 증례에서는 상악 완전 무치악 환자에 임플란트를 5개 식립하여, Pekkton으로 내 외관이 제작된 텔레스코픽 어태치먼트를 활용한 임플란트 유지 피개의치를 제작하고, 하악은 임플란트 고정성 보철로 수복하였다. 심미적 및 기능적으로 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

상악 완전무치악에서 지르코니아 framework을 이용한 임플란트 지지형 고정성 보철 수복 증례 (The rehabilitation of an edentulous maxilla with an implant-supported fixed prosthesis using a zirconia framework: A case report)

  • 변재준;장은선;공대룡;송주헌;이경제
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.342-348
    • /
    • 2020
  • 우식 및 치주질환등의 여러원인으로 다수의 치아를 발거 후 안면 및 치조골의 해부학적인 변화가 일어난다. 상악의 경우 치조골이 치근의 방향과 경사로 흡수되고 잔존치조골이 짧아지면서 악궁의 직경이 감소하게 된다. 또한 비순각(Nasolabial angle)이 커지면서 입술의 지지를 상실하게 되어 안면의 심미성을 상실하게 된다. 이를 재건하기 위해 다양한 수복 치료가 제안될 수 있다. 무치악 환자에게 보철적 재건 방법 중 전통적인 총의치 치료가 선택될 수 있지만 환자의 대부분은 의치에 의한 통증과 불편감, 안정성 부족으로 자연치를 갖는 사람들보다 저작능력이 20%미만이다. 또한 의치가 신체의 일부가 아님을 인지하고 심리적으로 만족하지 못하는 경우가 종종 있으며 이를 위해 저작기능 향상과 유지, 안정 그리고 치조골을 보존 할 수 있는 임플란트를 이용한 가철성과 고정성 보철 치료가 다른 대안이 될 수 있다. 상악 무치악 부위를 위한 임플란트 치료방법 선택 시 심미성을 위해 보철물의 변연을 원치 않거나 적절한 입술 지지, 발음의 향상, 구개를 덮지 않아 환자에게 편안함을 주는 방법으로 임플란트를 이용한 fixed detachable prosthesis 치료를 선택할 수 있다. 본 증례는 상악 잔존치조골 흡수로 부적절한 악간관계와 입술지지를 잃은 무치악 환자를 대상으로 지르코니아 framework을 이용한 임플란트 지지형 고정성 보철 치료를 진행하였고 기능적, 심미적으로 만족할 만한 결과를 얻었기에 이를 보고 하고자 한다.