• Title/Summary/Keyword: implant supported dental prosthesis

Search Result 150, Processing Time 0.033 seconds

Risk indicators related to periimplant disease: an observational retrospective cohort study

  • Poli, Pier Paolo;Beretta, Mario;Grossi, Giovanni Battista;Maiorana, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.4
    • /
    • pp.266-276
    • /
    • 2016
  • Purpose: The aim of the present study was to retrospectively investigate the influence of potential risk indicators on the development of peri-implant disease. Methods: Overall, 103 patients referred for implant treatment from 2000 to 2012 were randomly enrolled. The study sample consisted of 421 conventional-length (>6 mm) non-turned titanium implants that were evaluated clinically and radiographically according to preestablished clinical and patient-related parameters by a single investigator. A non-parametric Mann-Whitney U test or Kruskal-Wallis rank test and a logistic regression model were used for the statistical analysis of the recorded data at the implant level. Results: The diagnosis of peri-implant mucositis and peri-implantitis was made for 173 (41.1%) and 19 (4.5%) implants, respectively. Age (${\geq}65$ years), patient adherence (professional hygiene recalls <2/year) and the presence of plaque were associated with higher peri-implant probing-depth values and bleeding-on-probing scores. The logistic regression analysis indicated that age (P=0.001), patient adherence (P=0.03), the absence of keratinized tissue (P=0.03), implants placed in pristine bone (P=0.04), and the presence of peri-implant soft-tissue recession (P=0.000) were strongly associated with the event of peri-implantitis. Conclusions: Within the limitations of this study, patients aged ${\geq}65$ years and non-adherent subjects were more prone to develop peri-implant disease. Therefore, early diagnosis and a systematic maintenance-care program are essential for maintaining peri-implant tissue health, especially in older patients.

Clinical study on the comparison of gold and zirconia wear in an implant-supported fixed prosthesis (임플란트 지지 고정성 보철물에서 금과 지르코니아의 마모 비교에 대한 임상 연구)

  • Kim, Jee-Hwan;Yang, Seung-Won;Oh, NamSik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.252-259
    • /
    • 2017
  • Purpose: The purpose of this study was to compare and analyze the wear of a prosthesis for 6 months after restoration with implant-supported fixed dental prosthesis made of either zirconia or gold. Materials and Methods: This study was conducted on patients requiring implant-supported fixed dental prostheses on first or second molar from January, 2015 to January, 2016. A total of 47 prostheses and antagonists were examined. Occlusal surface was recorded by impression of each prosthesis and antagonist 1 week and 6 months after prosthesis delivery. The digital files were created by impression scan. Occlusal shapes of 1 week and 6 months were compared and wear of prostheses and antagonists was analyzed. The Mann-Whitney test was used to analyzed the result data underwent normality test using SPSS (Version 23.0, IBM Corporation) Results: Mann-Whitney test revealed that there was no statistically significant difference in the median amount of mean vertical wear for 6 months in zirconia ($50.84{\mu}m$) and gold ($42.84{\mu}m$) prostheses (P > 0.05). When the opposing teeth were natural, the median amount of mean vertical wear of zirconia and gold prostheses was $47.72{\mu}m$ and $41.97{\mu}m$, respectively, and the median amount of mean vertical wear of enamel was $47.26{\mu}m$ and $44.59{\mu}m$, respectively. Statistical analysis showed no significant difference (P > 0.05). Conclusion: Despite the short study period and the small number of experimental groups, zirconia and gold showed no significant difference in wear during the first 6 months. Opposing natural enamel also showed no significant difference in the wear.

Implant-retained overdenture with CM LOC® Pekkton® in maxillary edentulous patient (상악 완전 무치악 환자에서 CM LOC® Pekkton® attachment를 이용한 임플란트 유지 피개의치 수복 증례)

  • Hong, Mun Gi;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.321-328
    • /
    • 2017
  • Treatment options for edentulous patients are complete denture and implant prosthesis. A two implant-retained overdenture can be considered the first treatment in the edentulous mandible, but there is no clear consensus of treatment for edentulous maxilla. Implant-retention/support overdenture shows better retention and stability than complete denture and is less expensive and more esthetic than implant-supported fixed prosthesis. CM $LOC^{(R)}$ $Pekkton^{(R)}$ attachment is a solitary type attachment and evaluated to have excellent abrasion resistance and retention with a female part made of poly-ether-ketone-ketone. Meanwhile, SR Ivocap system is injection molding method and discussed to show few changes in the vertical dimension of denture and have excellent fracture resistance. In this case, we restored maxillary arch with a four implant-retained overdenture using CM $LOC^{(R)}$ $Pekkton^{(R)}$ and SR Ivocap system, and mandibular arch with a removable partial denture. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Effect of different surface treatments on the shear bond strength of luting cements used with implant-supported prosthesis: An in vitro study

  • Degirmenci, Kubra;Saridag, Serkan
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.75-82
    • /
    • 2020
  • PURPOSE. The aim of this study was to investigate the shear bond strength of luting cements used with implant retained restorations on to titanium specimens after different surface treatments. MATERIALS AND METHODS. One hundred twenty disc shaped specimens were used. They were divided into three groups considering the surface treatments (no treatment, sandblasting, and oxygen plasma treatment). Water contact angle of specimens were determined. The specimens were further divided into four subgroups (n=10) according to applied cement types: polycarboxylate cement (Adhesor Carbofine-AC), temporary zinc oxide free cement (Temporary CementZOC), non eugenol provisional cement for implant retained prosthesis (Premier Implant Cement-PI), and non eugenol acrylic-urethane polymer based provisional cement for implant luting (Cem Implant Cement-CI). Shear bond strength values were evaluated. Two-way ANOVA test and Regression analysis were used to statistical analyze the results. RESULTS. Overall shear bond strength values of luting cements defined in sandblasting groups were considerably higher than other surfaces (P<.05). The cements can be ranked as AC > CI > PI > ZOC according to shear bond strength values for all surface treatment groups (P<.05). Water contact angles of surface treatments (control, sandblasting, and plasma treatment group) were 76.17° ± 3.99, 110.45° ± 1.41, and 73.80° ± 4.79, respectively. Regression analysis revealed that correlation between the contact angle of different surfaces and shear bond strength was not strong (P>.05). CONCLUSION. The retentive strength findings of all luting cements were higher in sandblasting and oxygen plasma groups than in control groups. Oxygen plasma treatment can improve the adhesion ability of titanium surfaces without any mechanical damage to titanium structure.

The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment (변형된 임플란트 임시 지대주의 물성에 대한 연구)

  • Yang, Byung-Duk;Yoon, Tae-Ho;Choi, Un-Jae;Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

Implant supported prosthesis with high performance polymers using a double scanning method (Double Scanning에 의한 고성능 중합체를 이용한 임플란트 지지 고정성 보철물 수복 증례)

  • Kang, Kyeong-Hwan;Park, Jin-Hong;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.305-310
    • /
    • 2017
  • Nowadays, the development of dental scanner and CAD/CAM technology can facilitate the fabrication of hybrid prosthesis. Double scanning technique, scanning a trial prosthesis and master model, made it possible to realize virtual design and simplify the laboratory work. Instead of using the metal or zirconia framework with composite, ceramic or denture tooth, the new high performance polymer Polyetherketoneketone (Pekkton, Cendres+$M{\acute{e}}taux$, Biel, Switzerland) as a framework with Polymethyl methacrylate (PMMA) veneering teeth (Visio-lign, Bredent, Senden, Germany) was used in this case. This case report showed an acceptable treatment outcome and satisfaction of patient using Pekkton and Visio-lign. However, long term clinical evaluation is needed.

Maxillary complete denture with posterior zirconia occlusion and mandibular implant support fixed prostheses in completely edentulous patients with orofacial dystonia (구강안면 근긴장이상을 가진 완전 무치악 환자에서 구치부 지르코니아 교합면을 갖는 상악 총의치와 하악 임플란트 지지 고정성 보철물의 수복)

  • Jong-Min Seo;Chang-Mo Jeong;So-Hyoun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.237-249
    • /
    • 2023
  • Orofacial dystonia is a neuromotor disorder that causes irregular or repetitive movements of the face, lips, tongue, and jaw involuntarily, also called tic disorder. Edentulous patients with these symptoms experience functional and aesthetic problems, including difficulty using complete dentures, speech and swallowing difficulties, and orofacial pain. In this case, for a patient with orofacial dystonia who experienced complete edentulism at a relatively young age, restorative treatment was performed with a maxillary complete denture with bilateral posterior zirconia occlusal surfaces and a mandibular implant-supported fixed prosthesis, and continuous smile training was performed. The aim was to improve the aesthetics of facial muscles. As a result of the treatment, the patient was very satisfied with not only improved chewing function and aesthetics, but also regained psychological stability and was able to lead a normal daily life, so we would like to report this.

Implant-assisted removable partial denture in a maxillary edentulous patient: A case report (상악 무치악 환자에서 전방부 임플란트 지지 고정성 보철물을 이용한 임플란트 보조 국소의치 수복 증례)

  • Kang, Hyun-Mo;Kim, Jee-Hwan;Kim, Jae-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.442-452
    • /
    • 2022
  • Implant-assisted removable partial denture (IAPRD) can be considered as a simple and cost-effective treatment approach for an edentulous patient with anatomical or financial limitations. Recently, it was reported that the application of IARPD with implant supported fixed prostheses covered by the National Health Insurance Service (NHIS) were increasing. This case report describes the treatment of maxillary fully edentulous patient with anterior four-implant-supported fixed prosthesis and distal extension IARPD. This treatment approach may be advantageous over maxillary implant overdentures in some circumstances. The patient was satisfied with improved function and esthetics in the anterior area and financial benefit from the NHIS. Further long-term clinical studies are needed to establish clinical validity of the treatment approach described in this case report.

The incidence of the abutment screw loosening and its affecting factors in posterior implant restorations (구치부 임플란트 고정성 수복물에서의 지대주 나사 풀림 현상과 이에 영향을 미치는 요인)

  • Hong, Su-Jung;Bae, Jung-Yoon;Kim, Hyun-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.212-217
    • /
    • 2018
  • Purpose: This study was to assess clinically the incidence of abutment screw loosening of posterior implant-supported fixed prosthesis and its affecting factors. Materials and methods: 391 implant-supported crowns restored from January 2013 to January 2016 were included in this study. All restorations were fabricated with either a single crowns or a splinted crown, and cemented with temporary cement. The incidence of abutment screw loosening is investigated and gender, restoration position, opposing teeth, restoration type, abutment connection type were assessed as possible factors affecting abutment screw loosening. Results: During the observation period (2 - 5 years), abutment screw loosening was found in 29 restorations (7.4%). It took 3 to 48 months (means 19.5 months) to loose the screw, and three of these implants were fractured. Among the factors considered, there were statistically significant differences at abutment screw loosening rate between molar group (9.4%) and premolar group (2.6%) (P<.019). According to the type of opposing teeth, there were statistically significant differences between nature teeth (74.7%) and implant (25.0%), removable denture (3%) (P<.019). The other possible factors did not have a significant effect on loosening of the abutment. Conclusion: The incidence of abutment screw loosening in posterior restoration was 7.4%. Abutment screw loosening were more likely to occur in molars group than premolar group, and according to the opposing teeth, there were the greatest frequency in nature teeth than implant and removal denture. There was a statistically significant difference.

TREATMENT OF A PATIENT WITH CLEIDOCRANIAL DYSPLASIA USING IMPLANT-SUPPORTED BAR OVERDENTURE: A CASE REPORT (바 피개의치를 이용한 쇄골두개이형성증 환자의 치료: 증례보고)

  • Jang, Jung-Hui;Song, Min-Seok;Kim, Hyeon-Min;Kim, Nam-Hun;Eom, Min-Yong;Koo, Hyun-Mo;Yi, Jun-Kyu;Jeong, Jong-Cheol;Kim, Se-Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.1
    • /
    • pp.80-86
    • /
    • 2006
  • Cleidocranial dysplasia is rare inherited skeletal dysplasia. It was first reported by Martin in 1765. Subsequently, Marie and Sainton independently documented the criteria of the disease. Cleidocranial dysplasia is a bone disorder caused by a defect in the CBFA1 gene of chromosome 6p21. This gene guides osteoblastic differentiation and appropriate bone formation. Patient with cleidocranial dysplasia has maxillary deficiency, high and narrow palate, prolonged retention of primary teeth, unerupted permanent teeth and supernumerary teeth. Therapeutic options in these patients include of autotransplantation of selected impacted teeth, forced eruption of permanent teeth, full denture, overdenture and implant-supported prosthesis. We report a patient with cleidocranial dysplasia. This patient was treated with implant supported bar overdenture. Despite of gene defect that affects osteoblastic activity, bone remodeling and osseointegration occurred in our patient. So, we report this case with review of literature.