• 제목/요약/키워드: implant structure

검색결과 255건 처리시간 0.025초

하향식(Top-down)방식을 적용한 치과 임플란트 원가산정 (Dental implant cost by top-down approach)

  • 신호성;김민영
    • 대한치과의사협회지
    • /
    • 제52권7호
    • /
    • pp.416-424
    • /
    • 2014
  • The purpose of this study is to analyze the cost of dental implant by top-down method and, on that basis, to provide salient information for the suitable standard of dental insurance fee. A survey data and accounting documents from 36 samples of dental clinics secured with the organisation authority are used and analysed for extracting the representative sample of dental clinic. A researcher visited the dental clinics in person and conducted additional interviews in the omitted case of accounting documents. A dental implant cost by top-down method was estimated to 1,430,000 won. Labor cost accounted for 43% of the total cost structure, ranking it 1st and, management cost, material cost and interest cost on investment cost in order are investigated. Labor cost counts of the total cost that shows the similar aspect to the existing result. Cost in cost accounting of medical care would be used for the judge that cost pursed value for dental service, not price or fee.

하악골의 치조골 골삭제를 위한 동적 제약 기구부의 성능에 관한 연구 (A Study on the Performance of Dynamic Restraint Manipulator for Drilling Alveolar Bone in Mandible)

  • 김광호;이동운;정상화
    • 한국기계가공학회지
    • /
    • 제19권12호
    • /
    • pp.105-112
    • /
    • 2020
  • The increase in the edentulous jaw which occurs in the aged population has led to personal dental health concerns. In the case of dental implant surgery, the duration of a patient's recovery depends on the surgical plan and their physicical ability. A device may be required to assist a physician in controlling vibration reduction of free-hand drilling and prescribing a good treatment plan that is suitable for the patient's condition. In this work, an artificial tooth-root implant assistant manipulator was studied. The structure and the vibration analysis of the dynamic restraint manipulator that is for drilling the alveolar bone in the mandible bone were performed, and the structural stability was analyzed. Further, a virtual prototype of an artificial tooth-root implant assisted manipulator was fabricated and tested. Hence, the state of the Remote Center of Motion (RCM) point and the driving state of the manipulator were confirmed. Furthermore, the drilling experiments were performed by using materials similar to a human jawbone in order to evaluate the performance of the drilling process that is operated using the assistant manipulator.

무치악 환자에서 로케이터 부착장치를 이용한 임플란트 피개의치 수복 증례 (Implant overdenture treatment using Locator attachment system on edentulous patient)

  • 김수엽;신수연
    • 구강회복응용과학지
    • /
    • 제30권2호
    • /
    • pp.176-183
    • /
    • 2014
  • 심하게 흡수된 치조제는 기능적인 하중을 견디기 어렵고 구강 조직의 유해 변화와 더불어 환자의 의치 적응을 어렵게 한다. 환자의 불편감을 해소하고 의치의 안정성과 유지력을 증가시키기 위해 임플란트를 이용한 피개의치가 치료 방법으로 선택될 수 있다. 로케이터 부착장치는 사용상의 편리성이 높으며 다양한 유지력을 갖는 남자부를 보유함으로써 임상에서 볼 형태 부착장치대용으로 많이 사용되고 있다. 본 증례는 77세 여자환자로서 낮은 수직고경과 심한 치조제 흡수를 보이는 상하악 무치악 상태였다. 이에 하악에 4개의 임플란트를 식립하고, 상악은 총의치, 하악은 로케이터 부착장치를 이용한 임플란트 피개의치로 수복하여 기능 및 심미적으로 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

3D Printed Titanium Implant for the Skull Reconstruction: A Preliminary Case Study

  • Choi, Jong-Woo;Ahn, Jae-Sung
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권2호
    • /
    • pp.99-102
    • /
    • 2014
  • The skull defect can be made after the trauma, oncologic problems or neurosurgery. The skull reconstruction has been the challenging issue in craniofacial fields for a long time. So far the skull reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for skull reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile various types of allogenic and alloplastic materials have been also used. However, skull reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original skull anatomy as possible using the 3D printed titanium implant, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we fabricated Titanium implant to reconstruct three-dimensional orbital structure in advance, using the 3D printer. This prefabricated Titanium-implant was then inserted onto the defected skull and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

골결손부가 있는 발치직후 매식 임플란트에서 탈회동결건조골과 GTAM차단막이 골재생에 미치는 영향 (EFFECT OF DFDB AND GTAM BARRIERS ON BONE REGENERATION AROUND IMMEDIATE IMPLANTS PLACED IN SURGICALLY DFFECTIVE SOCKET)

  • 김형수;양홍서
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.43-66
    • /
    • 1997
  • Dental implant may be immediately placed in postextraction socket which has alveolar bone defect. The purpose of this study was to compare the bone regeneration and bone quality around defects adjacent to implants that were placed into extraction sockets according to EFEB, GTAM barrier and GTAM barrier with DFDB. Mandibular P2, P3 and P4 were extracted bilaterally in dogs, and buccal defects were created about 4mm in depth and 3.3mm in width. Screwed pure titanium implants, 3.8mm in diameter and 10mm in length, were placed into the extraction sockets. The experimental groups were divided into four groups : the G group was covered with a GTAM barrier on the defective area, the D+G group was filled with DFEB and covered with a GTAM barrier, the D group was filled with DFDB only and the control group was sutured without any special treatment on the defective area. The experimental animals were killed after 12 weeks and specimens were prepared for light microscopic evaluation and fluorescent dyes were administered daily for 2 weeks after implantation, and injected on the 4th and 11th week for fluorescent microscopic examination to observe new bone formation and bone remodeling. The new Bone height of the buccal defect was measured and compared with the another for bone gain and the removal torque for the implant was measured for the comparison of bone density and bone-implant osseointegration. Results obtained were as follows : 1. Experimental groups showed bone regeneration in oder from D+G, G, D group and control. D+G and G group was significantly from D group and control(P<0.01). 2. In the defective area of control the regenerated alveolar bone showed poorly developed lamellated structure and fibrous tissue intervention into the bone-implant interface but the others showed well developed lamellated structure and osseointegration. 3. All implant groups showed no significaant difference in the removal torque for implant(P>0.05) These results suggest that immediate implants placed in defective sockets were successfully osseointegrated and utilizing placed in defective sockets were successfully osseointegrated and utilizing not only the combination of GTAM and DFDB but also only the GTAM was favorable for the predictable regeneration of the defective area.

  • PDF

변형된 임플란트 임시 지대주의 물성에 대한 연구 (The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment)

  • 양병덕;윤태호;최운재;박주미
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

단일 임플랜트 보철물의 Hex-lock 형태에 따른 3차원 유한요소법적 응력분석 (A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT PROSTHESES ACCORDING TO THE HEX-LOCK TYPE)

  • 황영필;계기성;조규종
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.385-402
    • /
    • 1996
  • The purpose of this study was to analyze how the stability of the implant prostheses and the loosening of the fastening screw was affected when the various types of Hex structure provided for the effect of anti-rotation of the single prostheses were given. Three dimensional finite element model was designed with which the implants with the external hex type of 0.75mm, 1.5mm and the implant with the internal hex type of 0.75mm, 1.5mm and the implant with the external hex type of $15^{\circ}$ tapered shape of 0.75mm were supposed to completely osseointegrate to the mandible. After fininshing the finite element model, the preload of 10N at the fastening screw was applied and then the vertical and $30^{\circ}$ lateral load of 200N was applied respectively at the cusp tips of the prostheses. The following results were obtained : 1. In case of displacement, the amount of displacement was increased at the internal hex type(model C, D) than at the external hex type(model A, B, E) when the vertical and lateral load was applied. 2. Less equivalent stress was represented at the model B with increased external hex height than at the model A when the vertical and lateral load was applied. 3. Much stress was represented at the model E with increased hex angle than at the model A in case of the stress happened to the implant body and the fastening screw when the vertical and lateral load was applied. 4. Much equivalent stress was represented at the model D with deepened internal hex height than at the model C when vertical and lateral load was applied. 5. The least stress was taken at the model B and the most stress was taken at the model D in case of the stress happened to the implant when the vertical and lateral load was applied. 6. The least stress was taken at the model C at the vertical load. And the least stress was taken at the model B at lateral load in case of the stress happened to the fastening screw. As a results of this study, the good lateral stability of prostheses and less stress of the component of implant was taken when the external hex height was increased, and the risk of neck fracture of implant and fastening screw was increased when the internal hex height was deepned because of long screw neck portion and thin implant neck portion.

  • PDF

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography

  • Kang, Se-Ryong;Bok, Sung-Chul;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • 제46권2호
    • /
    • pp.116-127
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. Methods: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. Results: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). Conclusions: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.

하중 후 임프란트와 지르코니아 지대주 사이의 표면 변화 (Surface Changes between Implant and Zircoina Abutment after Loading)

  • 김문수;조영범;김희중
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.185-195
    • /
    • 2011
  • 본 연구는 외부연결방식(external type)의 임프란트에서 기존의 타이타늄 지대주와 지르코니아 지대주를 각각의 임플란트와 연결하여 하중을 가한 후 임플란트 외부육각기둥(external hexgon)부분 및 platform 표면변화를 FESEM 상으로 관찰하고, 임프란트와 타이타늄 지대주 및 지르코니아 지대주의 Viker's 경도를 측정하였다. 1. 임프란트, 타이타늄 지대주 및 지르코니아 지대주의 Viker's 경도는 각각 평균 $309.80{\pm}11.78$ HV, $318.40{\pm}11.82$ HV, $1495.30{\pm}16.21$ HV였다. 임프란트와 타이타늄 지대주 사이에는 통계학적으로 유의성이 존재하지 않았지만(P>0.05, Anova), 임프란트와 지르코니아 사이에는 통계학적으로 유의성이 관찰되었다(P<0.05, Anova). 2. 10,000번 하중을 가한 후 임플란트 표면변화 관찰에서 타이타늄 지대주 그룹과 지르코니아 지대주 그룹 모두에서 마모가 관찰 되었으며, 지르코니아 지대주에서 보다 현저한 마모양상을 나타내었다. 본 연구에서 표면경도의 차이로 인하여 타이타늄 지대주를 사용할 때보다 지르코니아 지대주를 사용한 경우 임플란트의 external hexagon부분 및 플랫폼의 마모도가 현저하였다.

교정력이 골유착성 티타니움 임프란트의 초기 고정에 미치는 영향에 관한 실험적 연구 (The effect of early loading on the direct bone-to-implant surface contact of the orthodontic osseointegrated titanium implant)

  • 정규림;이성자
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.173-185
    • /
    • 2001
  • 본 연구는 경희대학교 치과대학 교정과와 Biosstech$^{\circledR)$이 개발한 교정용 골유착성 티타니움 임프란트를 이용하여 임프란트 매식 후 가해지는 교정력이 임프란트의 골유착에 미치는 영향과 임프란트 제거 후 손상된 치조골의 치유를 알아보기 위해 시행되었다. acid-etched type, sand-blasted type, sand-blasted & acid-etched type, 3종류의 교정용 임프란트 24개를 2마리 실험 동물의 구강 내에 식립하였다. dog1의 상하악 좌측에 식립한 6개 임프란트에는 식립 후 교정력을 주지 않았고, 우측에 식립한 6개 임프란트에는 식립 즉시 200-300gm의 교정력을 가하였다. dog2에서는 임프란트 식립후 4주의 치유기간을 기다린 후, 골 내에 고정되어 있는 모든 임프란트에 4주 동안 200-300gm의 교정력을 가하였다. 4주, 8주의 관찰 기간이 지난 후 실험 동물을 각각 희생시켜 임프란트와 주위 조직을 포함하는 비탈회 표본을 제작하여 광학 현미경하에서 검경하였다. 이 실험을 통해 다음과 같은 결과를 얻었다. 1. 골내 고정에 성공한 임프란트들의 식립 4주 후 조직 소견에서, 식립 즉시 교정력을 가한 임프란트와 교정력을 가하지 않은 임프란트 사이에 조직학적 차이가 없었다. 두 군 모두에서 미성숙 소주골이 임프란트 식립시 손상된 부위로 생성되고 있었으며 부분적인 골유착이 보였다. 2. 임프란트 식립 부위의 골손상이 완전히 치유되기 전에 가해진 교정력은 골유착의 진행을 방해하지 않았다. 4주의 치유기간 후 4주간 교정력을 가한 임프란트의 조직소견에서 골조직과 임프란트 계면 사이의 접촉은 더 넓은 부위로 진행되었고 나사골을 채우고 있는 신생골은 기저골의 구조와 형태를 닮은 층판골로 성숙되어 있었다. 3. 식립 후 임프란트 주위 연조직 염증이 심했던 임프란트는 대부분 탈락되거나 동요가 있었으며, 실험 동물 희생시 동요가 있었던 임프란트의 조직 소견에서 임프란트 주위는 연조직으로 둘러 쌓여 골조직과 분리되어 있었다. 4. 골내 고정에 실패한 임프란트의 식립 부위에서는 임프란트 제거 2주 후 염증 소견없이 왕성한 골형성을 나타내는 조직학적 소견이 관찰되었다.

  • PDF