Surface Changes between Implant and Zircoina Abutment after Loading  

Kim, Moon-Soo (Department of prosthodontics, college of Dentistry, Chosun University)
Cho, Young-Bum (Department of prosthodontics, college of Dentistry, Chosun University)
Kim, Hee-Jung (Department of prosthodontics, college of Dentistry, Chosun University)
Publication Information
Journal of Dental Rehabilitation and Applied Science / v.27, no.2, 2011 , pp. 185-195 More about this Journal
Abstract
In this study, titanium abutments and zirconia abutments were connected to each implant in external type implants. After that they were loaded 10000 times with 20Kg as occlusal force. The surface changes of external hexgon part and platform were observed in FESEM image. Viker's hardness of an implant, a titanium abutment and a zirconia abutment were measured respectively. 1. Viker's hardness of an implants, a titanium abutment and a zirconia abutment was $309.80{\pm}11.78$ HV, $318.40{\pm}11.82$ HV, and $1495.30{\pm}16.21$ HV respectively. There was no statistical significance between an implant and a titanium abutment (P>0.05, Anova). However, there was statistical significance between an implant and a zirconia abutment(P<0.05, Anova). 2. The wear was observed at the joint of implant and abutment in both a titanium abutment group and a zirconia abutment group after loading 10,000 times. The zirconia abutment showed more remarkable wear than the titanium one. In conclusion, the wear of external hexagon and platform was much more notable in a zirconia abutment group than a titanium one. It was suggested that it could result from the difference of surface hardness between titanium and zirconia. The wear of junction between an implant and a zirconia abutment becomes more severe, the connection of an implant and an abutment is much more unfit. This is likely to cause loosening and fracture of the abutment screw. so it is considered that the possibility of implant supra-structure failure can be increased.
Keywords
Zirconia abutment; Viker's hardness; surface changes;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Brodbeck U. The ZiReal Post: A new ceramic implant abutment. J Esthet Restor Dent 2003;15(1): 10-23   DOI   ScienceOn
2 Nguyen HQ, Tan KB, Nicholls JI. Load fatigue performance of implant-ceramic abutment combinations. Int J Oral Maxillofac Implants 2009;24(4): 636-646.
3 Gomes AL, Montero J. Zirconia implant abutments: A review. Med Oral Patol Oral Cir Bucal. 2010: 1.
4 Zembic A, Sailer I, Jung RE, Hämmerle CH. Randomized-controlled clinical trial of cual mized zirconia and titanium implant abutments for single- tooth implants in canine and posterior regions: 3-year results. Clin Oral Implants Res 2009;20(8):802-808.   DOI   ScienceOn
5 Yuzugullu B, Avci M. The implant-abutment interface of alumina and zirconia abutments. Clin Implant Dent Relat Res 2008;10(2):113-121.   DOI   ScienceOn
6 Brodbeck U. The ZiReal Post: A new ceramic implant abutment. J Esthet Restor Dent 2003;15(1): 10-23.   DOI   ScienceOn
7 Adatia ND, Bayne SC, Cooper LF, Thompson JY. Fracture resistance of yttria-stabilized zirconia dental implant abutments. J Prosthodont 2009;18(1):17-22.   DOI   ScienceOn
8 Cho HW, Dong JK, Jin TH, Oh SC, Lee HH, Lee JW. A study on the fracture strength of implant-supported restorations using milled ceramic abutments and all-ceramic crowns. Int J Prothodont 2002;15:9-13.
9 Sailer I, Sailer T, Stawarczyk B, Jung RE, Hämmerle CH. In vitro study of the influence of the type of connection on the fracture load of zirconia abutments with internal and external implant-abutment connections. Int J Oral Maxillofac Implants 2009;24 (5):850-858.
10 Scherrer SS, Kelly JR, Quinn GD, Xu K. Fracture toughness(KIc) of a dental porcelain determined by fractographic analysis. Dent Mater 1999;15:342-348.   DOI   ScienceOn
11 Yildirim M,Fischer H,Marx R, Edelhoff D. In vivo fracture resistance of implant-supported all-ceramic restorations. J Prothet Dent 2003;90:325-331.   DOI   ScienceOn
12 Nothdurft FP, Doppler KE, Erdelt KJ, Knauber AW, Pospiech PR. Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crowns. Clin Oral Investig 2010:19.
13 Lee MS, Suh KW, Ryu JJ. Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments. J Korea Aca Prosthodont 2009;47:164-173.   DOI   ScienceOn
14 Binon PP. Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs. Int J Prothodont 1995;8: 162-178.