• 제목/요약/키워드: implant failure

검색결과 302건 처리시간 0.022초

A STUDY ON SURFACE ALTERATION OF IMPLANT SCREWS AFTER FUNCTION

  • Han, Myung-Ju;Chung, Chae-Heon;Choi, Han-Cheol
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.275-286
    • /
    • 2002
  • Statement of problem. Surface alteration of the implant screws after function may be associated with mechanical failure. Theses metal fatigue appears to be the most common cause of structural failure. Purpose. The purpose of this study was to evaluate surface alteration of the implant screws after function through the examination of used and unused implant screws in SEM(scanning electron microscope). Materials and methods. In this study, abutment screws(Steri-oss, 3i), gold retaining screw(3i) and titanium retaining screw(3i) were retrieved from patients. New, unused abutment and retaining screws were prepared for control group. Each of the old, used screws was retrieved with a screwdriver. And retrieved implant complex of Steri-oss system was prepared for this study. Then, SEM investigation and EDS analysis of abutment and retaining screws were performed. And SEM investigation of cross-sectioned sample of retrieved implant complex was performed. Results. In the case of new, unused implant screws, as maunfactured circumferential grooves are regularly examined and screw thread are sharply remained. Before ultrasonic cleansing of old, used implant screw, a lot of accumulation and corrosion products were existed. After ultrasonic cleansing of old, used implant screws, circumferential grooves as examined before function were randomly deepened and scratches increased. Also, dull screw thread was examined. More surface alterations after function were examined in titanium screw than gold screw. And more surface alteration was examined when retrieved with driver than retrieved without driver. Conclusions. These surface alteration after function may result in the screw instability. Regularly cleansing and exchange of screws was recommended. We recommend the use of gold screw rather than titanium screw, and careful manipulation of the driver.

측방 접근법을 이용하여 상악동 거상술을 시행한 부위에 식립한 임플란트의 생존율에 대한 후향적 연구 (Survival rate of implant placement in the maxilla treated with sinus elevation by the lateral approach : A retrospective study)

  • 이은선;안용범;이원진;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제38권4호
    • /
    • pp.589-594
    • /
    • 2008
  • Purpose: Osseointegration of implants in patients with pneumatized maxillary sinuses is difficult to achieve due to the deficiency of available bone in the posterior maxilla after loss of teeth. Maxillary sinus elevation is a method to overcome this problem. In this study, we evaluated the implant survival rate and the relationship between implant survival in patients with sinus elevation by the lateral approach. Materials and Methods: A total of 48 patients were consecutively treated with sinus elevation by the lateral approach between February 2003 & August 2006 at the dental hospital of Chonbuk National university. A total of 113 implants were placed. The mean healing period was 7.1 months and implants were placed after a mean period of 5.6 months. The mean observation period was 21.8 months. Results: Out of the 113 implants placed, fifteen failed, resulting in a survival rate of 86.7%, 18 cases of sinus membrane perforation were observed out of 65 sinuses treated. 33 implants were placed in a perforated site and 10 failed, representing a 60.7% implant survival. 80 implants were placed in a nonperforated site and 5 failed, representing a 92.6% implant survival. Conclusions: Implant placement with sinus elevation is an acceptable treatment for short term results. Sinus membrane perforation and postoperative complications, however, may have an effect on implant failure.

Influence of the connection design and titanium grades of the implant complex on resistance under static loading

  • Park, Su-Jung;Lee, Suk-Won;Leesungbok, Richard;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.388-395
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the resistance to deformation under static overloading by measuring yield and fracture strength, and to analyze the failure characteristics of implant assemblies made of different titanium grades and connections. MATERIALS AND METHODS. Six groups of implant assemblies were fabricated according to ISO 14801 (n=10). These consisted of the combinations of 3 platform connections (external, internal, and morse tapered) and 2 materials (titanium grade 2 and titanium grade 4). Yield strength and fracture strength were evaluated with a computer-controlled Universal Testing Machine, and failed implant assemblies were classified and analyzed by optical microscopy. The data were analyzed using the One-way analysis of variance (ANOVA) and Student's t-test with the level of significance at P=.05. RESULTS. The group $IT4_S$ had the significantly highest values and group IT2 the lowest, for both yield strength and fracture strength. Groups $IT4_N$ and ET4 had similar yield and fracture strengths despite having different connection designs. Group MT2 and group IT2 had significant differences in yield and fracture strength although they were made by the same material as titanium grade 2. The implant system of the similar fixture-abutment interfaces and the same materials showed the similar characteristics of deformation. CONCLUSION. A longer internal connection and titanium grade 4 of the implant system is advantageous for static overloading condition. However, it is not only the connection design that affects the stability. The strength of the titanium grade as material is also important since it affects the implant stability. When using the implant system made of titanium grade 2, a larger diameter fixture should be selected in order to provide enough strength to withstand overloading.

Oral rehabilitation of Papillon-Lefèvre syndrome patients by dental implants: a systematic review

  • Atarbashi-Moghadam, Fazele;Atarbashi-Moghadam, Saede;Kazemifard, Setare;Sijanivandi, Soran;Namdari, Mahshid
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권4호
    • /
    • pp.220-227
    • /
    • 2020
  • Objectives: Papillon-Lefèvre syndrome (PLS) is a rare autosomal recessive disorder. These patients lose their teeth at a young age and are in need of prosthetic rehabilitation. The aim of this systematic review was to assess the success of dental implant placement in these patients. Materials and Methods: An electronic search was performed in PubMed Central, Scopus, and Web of Science using the keyword "Papillon-Lefèvre syndrome" AND "dental implant" OR "prosthodontics". Articles reporting implant placement in patients with PLS until July 2019 were included. Results: Assessment of the included 11 articles reporting 15 cases showed 136 implant placements in these patients. Implant failure occurred in 3 patients (20 implants). The peri-implantitis and failure rate was higher in the maxilla. Meta-analysis showed the probability of failure to be 7% (95% confidence interval [CI] 0%-31%) for maxillary implants and 2% (95% CI 0%-9%) for mandibular implants. The follow-up time ranged between 1 and 20 years. Healing after bone graft and implant placement in these patients was uneventful. Conclusion: Dental implants may be a viable treatment option for PLS patients. Implantation can help preserve alveolar bone if the patients' immunological and growing conditions are well-considered and proper oral hygiene and compliance with the maintenance program are continued.

Cochlear Implant Failure in the Pediatric Population

  • Ozer, Fulya;Yavuz, Haluk;Yilmaz, Ismail;Ozluoglu, Levent N.
    • Journal of Audiology & Otology
    • /
    • 제25권4호
    • /
    • pp.217-223
    • /
    • 2021
  • Background and Objectives: In cochlear implant (CI) surgery, the results and causes of revision and reimplantation may guide surgeons in establishing surgical protocols for revision surgery with safe audiological outcomes. The aim of this study was to review our experience in terms of etiology, surgical strategy, and hearing outcomes in pediatric patients who underwent CI removal and reimplantation. Subjects and Methods: All patients received implants of the same brand. Pre and postoperative Categories of Auditory Performance score and aided free-field pure tone audiometry thresholds were noted. In vivo integrity tests were performed for each patient and the results of ex vivo tests of each implant were obtained from manufacturer. Results: A total of 149 CIs were placed in 121 patients aged <18 years. The revision rate in children was 6.7% (10/121 children). Six patients had a history of head injury leading to a hard failure. The causes of reimplantation in others were soft failure (n=1), electrode migration (n=1), infection (n=1), and other (n=1). All patients showed better or similar postreimplantation audiological performance compared with pre-reimplantation results. Conclusions: It is very important to provide a safe school and home environment and educate the family for reducing reimplantation due to trauma. Especially for active children, psychiatric consultation should be continued postoperatively.

Cochlear Implant Failure in the Pediatric Population

  • Ozer, Fulya;Yavuz, Haluk;Yilmaz, Ismail;Ozluoglu, Levent N.
    • 대한청각학회지
    • /
    • 제25권4호
    • /
    • pp.217-223
    • /
    • 2021
  • Background and Objectives: In cochlear implant (CI) surgery, the results and causes of revision and reimplantation may guide surgeons in establishing surgical protocols for revision surgery with safe audiological outcomes. The aim of this study was to review our experience in terms of etiology, surgical strategy, and hearing outcomes in pediatric patients who underwent CI removal and reimplantation. Subjects and Methods: All patients received implants of the same brand. Pre and postoperative Categories of Auditory Performance score and aided free-field pure tone audiometry thresholds were noted. In vivo integrity tests were performed for each patient and the results of ex vivo tests of each implant were obtained from manufacturer. Results: A total of 149 CIs were placed in 121 patients aged <18 years. The revision rate in children was 6.7% (10/121 children). Six patients had a history of head injury leading to a hard failure. The causes of reimplantation in others were soft failure (n=1), electrode migration (n=1), infection (n=1), and other (n=1). All patients showed better or similar postreimplantation audiological performance compared with pre-reimplantation results. Conclusions: It is very important to provide a safe school and home environment and educate the family for reducing reimplantation due to trauma. Especially for active children, psychiatric consultation should be continued postoperatively.

만성 치주염 환자에서 임프란트의 예후에 관한 후향적 연구 (The retrospective study of the prognosis of implants in chronic periodontitis patients)

  • 김지은;박광호;조규성;문익상
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.373-382
    • /
    • 2003
  • The successful use of osseointegrated implants to replace missing teeth has been demonstrated for both the completely and the partially edentulous patients. Many studies have confirmed an excellent long-term prognosis. The successful outcome of any implant procedure is surely dependent on the interrelationship of the various components that includes the following: biocompatibility of the implant material, macroscopic and microscopic nature of the implant surface, the status of the implant bed in both a health(noninfected) and a morphologic(bone quality) context, the surgical technique, the undisturbed healing phase, the subsequent prosthetic design, and long-term loading phase. Periodontally compromised patients have poor status of the implant bed and periodontal pathogen. No longitudinal data are available whether these factors affect the prognosis of implants. In this study, 102 machined $Br{{\aa}}nemark$ implants are inserted to analyze the success rate of 1-4 years and marginal bone loss in 49 chronic periodontitis patients. The following conclusions could be drawn from this study. 1. The cumulative success rate of implants at the 4-year of loading was 95.10%. 2. 5 failed implants have been removed. One implant have been removed due to infection, two implants were removed due to failure of osseointegration. and other two implants were removed due to mechanical failure caused by over-loading. 3. Mean marginal bone loss from the time of loading was 0.94mm at first year, 1.12mm at second year, 1.25mm at third year. These results suggest that implant therapy is good treatment modality in chronic periodontitis patients, and periodontal treatment including oral hygiene program is completed prior to insertion of implants.

내측연결 시스템에서 임플란트 고정체의 경부 형태에 따른 지지골에서의 유한요소 응력분석 (Finite Element Stress Analysis in Supporting Bone according to Crest Module Shape of Fixture in Internal Connection System)

  • 박영남;김희중;오상호;정재헌
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.55-74
    • /
    • 2006
  • The external contour of an implant can have significant effects on the load transfer characteristics and may result in different bone failure rates for different implant system. The purpose of this study was to investigate the effects of crest module shape and occlusal load direction on bone failure modes of five commercially available dental implant systems. Five different implant systems with internal connection; ITI (Model 1), Astra (Model 2), Bicon (Model 3), Friadent (Model 4), and Paragon (Model 5), comparable in size, but different in thread profile and cest module shapes, were compared using the finite element method. Conclusively, in the internal connection system of the implant-abutment connection methods, the stress-induced pattern at the supporting bone according to the abutment connection form had differenence among them, and implants with narrowing crestal module cross-sections at the top of the cortical bone created more favorable load transfer characteristics in this region. But it is considered that the future study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.

임상가를 위한 특집 3 - Conventional loading, 여전히 임상적으로 유용한가? (Conventional loading, is the concept still useful?)

  • 여인성
    • 대한치과의사협회지
    • /
    • 제51권4호
    • /
    • pp.204-209
    • /
    • 2013
  • Implant-supported restorations were connected to commercially pure titanium endosteal implants 3 months in mandible and 6 months in maxilla after the implants were inserted into patient jaws. Modifications of titanium implant surfaces have reduced the waiting time for osseointegration, resulting in the development of the early loading concept, which is defined at present as a restoration in contact with the opposing dentition and placed at least 1 week after implant placement, but no later than 2 months afterward. Nowadays, immediate loading protocols have also been introduced, using the implants that are designed to enhance initial stability. Immediate loading eliminates the edentulous period of a patient. Although dentists widely accept these concepts of early and immediate loading, they agree the conventional loading concept is still necessary, which describes loading protocols later than 2 months after implant insertion. The timing of loading is determined mainly by the factors of a patient. This paper considers for what dental clinicians should be careful in implant-supported restoration procedures, considering the implant late failure.