• Title/Summary/Keyword: implant failure

Search Result 302, Processing Time 0.026 seconds

A Study on the Stress Distribution of Tooth/Implant Connected with Konus Telescope Denture Using 3-Dimensional Finite Element Method (이중관으로 연결된 자연치와 임플랜트의 악골 내응력분포에 관한 3차원 유한요소분석)

  • Lee, Su-Ok;Choi, Dae-Gyun;Kwon, Kung-Rock;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.381-395
    • /
    • 2008
  • Purpoose: For decades dental implants have been used widely in the field of prosthetic dentistry. However there is confusion when establishing treatment plans in cases where some teeth are remained but an insufficient number of implants can be used due to limited anatomical status and ecomomical problems. Many clinicians have tried to connect natural teeth and implants, and it still has controversy. But, there have been few studies on mechanical analysis of connecting natural teeth and implants with konus telescopic removable partial dentures. The purpose of this study was to analyze the stress distribution of prosthesis, abutment and alveolar bone when teeth and implants were connected with the konus telescopic denture, by means of 3-dimensional finite element analysis. Material and methods: The assumption of this study was that there were 2 mandibular canine (11 mm in length, 4 mm in diameter) and 2 implants(10 mm in length, 4 mm in diameter) which are located in the second premolar region. The mandible, teeth, implants, abutments, and connectors are modeled, and analyzed with the commercial software, ANSYS Version 8.1(Swanson, Inc., USA). The control group used implants instead of natural teeth. 21038 elements, 23544 nodes were used in experimental group and 107595 elements, 21963 nodes were used in control group, Stress distribution was evaluated under 150 N vertical load on 3 experimental conditions - between teeth and implants (Load case 1), posterior to implants (Load case 2), between natural teeth (Load case 3). Results: 1. In all load cases, higher von mises stress value was observed in the experimental group. 2. Maximum von miss stress observed in all load cases and all locations were as follows ; a. 929.44 Mpa in the experimental group, 640.044 Mpa in the control group in outer crown and connector - The experimental group showed 1.45 times high value compared with the control group. b. 145,051 Mpa in the experimental group, 142.338 Mpa in the control group in abutment - The experimental group showed 1.02times high value compared with the control group. c. 32.489 Mpa in the experimental group, 25.765 Mpa in the control group in alveolar bone - The experimental group showed 1.26times higher value compared with the control group. 3. All maximum von mises stress was observed in load case 2, and maxim von mises stress in alveolar bone was 32.489 Mpa at which implant failure cannot occur. 4. If maximum von mises stress is compared between two groups, the value of the experimental group is 1.02 times higher than the control group in abutment, 1.26 times higher than the control group in alveolar bone. Conclusion: If natural teeth and implants are connected with the konus telescopic denture, maximum stress will be similar in abutment, 1.26 times higher in alveolar bone than the control group. With this result, there may be possible to make to avoid konus telescopic dentures where natural teeth and implants exist together.

Long-Term Survival Analysis of Unicompartmental Knee Arthroplasty (슬관절 부분 치환술의 장기 생존 분석)

  • Park, Cheol Hee;Lee, Ho Jin;Son, Hyuck Sung;Bae, Dae Kyung;Song, Sang Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.427-434
    • /
    • 2019
  • Purpose: This study evaluated the long term clinical and radiographic results and the survival rates of unicompartmental knee arthroplasty (UKA). In addition, the factors affecting the survival of the procedure were analyzed and the survival curve was compared according to the affecting factors. Materials and Methods: Ninety-nine cases of UKA performed between December 1982 and January 1996 were involved: 10 cases with Modular II, 44 cases with Microloc, and 45 cases with Allegretto prostheses. The mean follow-up period was 16.5 years. Clinically, the hospital for special surgery (HSS) scoring system and the range of motion (ROM) were evaluated. Radiographically, the femorotibial angle (FTA) was measured. The survival rate was analyzed using the Kaplan-Meier method. Cox regression analysis was used to identify the factors affecting the survival according to age, sex, body mass index, preoperative diagnosis, and type of implant. The Kaplan-Meier survival curves were compared according to the factors affecting the survival of UKA. Results: The overall average HSS score and ROM was 57.7 and 134.3° preoperatively, 92.7 and 138.4° at 1 year postoperatively, and 79.1 and 138.4° at the last follow-up (p<0.001, respectively). The overall average FTA was varus 0.8° preoperatively, valgus 4.1° at postoperative 2 weeks, and valgus 3.0° at the last follow-up. The overall 5-, 10-, 15- and 20-year survival rates were 91.8%, 82.9%, 71.0%, and 67.0%, respectively. The factors affecting the survival were the age and type of implant. The risk of the failure decreased with age (hazard ratio=0.933). The Microloc group was more hazardous than the other prostheses (hazard ratio=0.202, 0.430, respectively). The survival curve in the patients below 60 years of age was significantly lower than those of the patients over 60 years of age (p=0.003); the survival curve of the Microloc group was lower compared to the Modular II and Allegretto groups (p=0.025). Conclusion: The long-term clinical and radiographic results and survival of UKA using old fixed bearing prostheses were satisfactory. The selection of appropriate patient and prosthesis will be important for the long term survival of the UKA procedure.

Limb Salvage Using a Combined Distal Femur and Proximal Tibia Replacement in the Sequelae of an Infected Reconstruction on Either Side of the Knee Joint (슬관절 주위 재건물 감염 후유증 시 슬관절 상하부 종양인공관절을 이용한 사지 구제술)

  • Jeon, Dae-Geun;Cho, Wan Hyeong;Park, Hwanseong;Nam, Heeseung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • Purpose: Tumor infiltration around the knee joint or skip metastasis, repeated infection sequelae after tumor prosthesis implantation, regional recurrence, and mechanical failure of the megaprosthesis might require combined distal femur and proximal tibia replacement (CFTR). Among the aforementioned situations, there are few reports on the indication, complications, and implant survival of CFTR in temporarily arthrodesed patients who had a massive bony defect on either side of the knee joint to control infection. Materials and Methods: Thirty-four CFTR patients were reviewed retrospectively and 13 temporary arthrodesed cases switched to CFTR were extracted. All 13 cases had undergone a massive bony resection on either side of the knee joint and temporary arthrodesis state to control the repeated infection. This paper describes the diagnosis, tumor location, number of operations until CFTR, duration from the index operation to CFTR, survival of CFTR, complications, and Musculoskeletal Tumor Society (MSTS) score. Results: According to Kaplan-Meier plot, the 5- and 10-year survival of CFTR was 69.0%±12.8%, 46.0%±20.7%, respectively. Six (46.2%) of the 13 cases had major complications. Three cases underwent removal of the prosthesis and were converted to arthrodesis due to infection. Two cases underwent partial change of the implant due to loosening and periprosthetic fracture. The remaining case with a deep infection was resolved after extensive debridement. At the final follow-up, the average MSTS score of 10 cases with CFTR was 24.6 (21-27). In contrast, the MSTS score of 3 arthrodesis cases with failed CFTR was 12.3 (12-13). The average range of motion of the 10 CFTR cases was 67° (0°-100°). The mean extension lag of 10 cases was 48° (20°-80°). Conclusion: Although the complication rates is substantial, conversion of an arthrodesed knee to a mobile joint using CFTR in a patient who had a massive bony defect on either side of the knee joint to control infection should be considered. The patient's functional outcome was different from the arthrodesed one. For successful conversion to a mobile joint, thorough the eradication of scar tissue and creating sufficient space for the tumor prosthesis to flex the knee joint up to 60° to 70° without soft tissue tension.

APPLICATION OF CAD/CAM FOR ORAL REHABILITATION IN A PATIENT WITH DOWN SYNDROME (CAD/CAM을 이용한 다운 증후군 환자의 구강 재건)

  • Chung, Hyunjin;Shim, Joon-Sung;Choi, Byung-Jai;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.13 no.2
    • /
    • pp.95-98
    • /
    • 2017
  • Due to hypodontia, poor oral hygiene, and significantly more prevalent periodontal disease, patients with Down syndrome show higher incidence of edentulism. Oral rehabilitation of such patients is imperative but challenging as high rates of prosthesis failure are reported due to malocclusion, high masticatory force, and parafunctional habits. As CAD/CAM(Computer-Aided Design and Computer Aided Manufacturing) is the recent trend in prosthodontics, this report discusses the application of CAD/CAM in a Down syndrome patient. A 25-year-old patient with Down syndrome was presented to the Department of Pediatric Dentistry, Yonsei University Dental Hospital for oral examination. 5 maxillary teeth were missing, 3 were fully impacted, and 4 had grade III mobility. The patient underwent general anesthesia for extraction of impacted and mobile teeth, implant surgery, and final impression for prosthesis. Afterwards, CAD/CAM was used to design and manufacture a 10-unit zirconia bridge. However the bridge was fractured after 18 months due to the patient's bruxism and high masticatory force. Final impression taking, bite registration, cast fabrication, cast scanning, and prosthesis designing were not needed as CAD/CAM data remained. Previous CAD/CAM design was used to remanufacture the zirconia bridge. Down syndrome patients have malocclusion, high masticatory force, and parafunctional habits which increase the possibility of prosthesis fracture. CAD/CAM is beneficial for Down syndrome patients as previous digital records can be utilized for prosthesis repair or remake. In detail, application of CAD/CAM in remanufacturing decreases patient's discomfort of impression taking, shortens and simplifies dental laboratory procedures, and reduces clinician's effort of taking detailed final impressions or accurate bite registration. In conclusion, oral rehabilitation using CAD/CAM provides not only satisfactory levels of comfort, stability, and esthetics, but also easier repair or remake compared to conventional prostheses.

Aseptic Humeral Nonunion: What Went Wrong? What to Do? A Retrospective Analysis of 20 Cases

  • Kim, Jinil;Cho, Jae-Woo;Cho, Won-Tae;Cho, Jun-Min;Kim, Namryeol;Kim, Hak Jun;Oh, Jong-Keon;Kim, Jin-Kak
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.129-138
    • /
    • 2016
  • Purpose: Due to recent advances in internal fixation techniques, instrumentation and orthopedic implants there is an increasing number of humeral shaft fracture treated operatively. As a consequence, an increased number nonunion after operative fixation are being referred to our center. The aim of this study is to report the common error during osteosynthesis that may have led to nonunion and present a systematic analytical approach for the management of aseptic humeral shaft nonunion. Methods: In between January 2007 to December 2013, 20 patients with humeral shaft nonunion after operative procedure were treated according to our treatment algorithm. We could analysis x-rays of 12 patients from initial treatment to nonunion. In a subgroup of 12 patients the initial operative procedure were analyzed to determine the error that may have caused nonunion. The following questions were used to examine the cases: 1) Was the fracture biology preserved during the procedure? 2) Does the implant construct have enough stability to allow fracture healing? Results: In 19 out of 20 patients have showed radiographic evidence of union on follow up. One patient has to undergo reoperation because of the technical error with bone graft placement but eventually healed. There were 2 cases wherein the treatment algorithm was not followed. All patients had problems with mechanical stability, and in 13 patients had biologic problems. In the analysis of the initial operative fixation, only one of 12 patients had biologic problems. Conclusion: In our analysis, the common preventable error made during operative fixation of humeral shaft fracture is failure to provide adequate stability for bony union to occur. And with these cases we have demonstrated a systematic analytic management approach that may be used to prevent surgeons from reproducing the same fault and reduce the need for bone grafting.

Factors affecting treatment outcomes in patients with oral lichen planus lesions: a retrospective study of 113 cases

  • Park, Shin-Young;Lee, Hyo-Jung;Kim, So-Hyun;Kim, Sung-Beom;Choi, Yong-Hoon;Kim, Young-Kyun;Yun, Pil-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.213-223
    • /
    • 2018
  • Purpose: Oral lichen planus (OLP) is a chronic oral mucosal disease that has been recognized as an immune condition. The purpose of this study was to evaluate factors affecting the clinical outcomes of topical corticosteroid application on OLP lesions using dexamethasone gargle and ointment. Methods: The charts of patients who were clinically diagnosed with OLP and treated with dexamethasone from July 2003 to August 2017 at the Section of Dentistry of Seoul National University Bundang Hospital were thoroughly evaluated to identify subjects who were suitable for this retrospective study. For each patient, age at the index date, gender, medical history, and dental records related to OLP lesions and dexamethasone treatment were reviewed. Results: In total, 113 of the 225 patients were included in the present study. Among them, 79 patients were female (69.9%) and 34 were male (30.1%), with a mean age of 57.6 years. The average duration of dexamethasone treatment was 4.7 months and the mean follow-up period was 2.24 years. Improvements were observed within 1 year after dexamethasone treatment in most cases, and 17.7% of patients had a new OLP lesion after treatment. New OLP lesions were more frequently gingival than mucosal, although mucosal OLP lesions were more common than gingival OLP lesions in all age groups. In age- and gender-adjusted multivariate logistic regression, a history of malignant disease was found to be a significant factor affecting the formation of new lesions. Gingival OLP lesions and intermittent use of dexamethasone showed near-significant associations. In Kaplan-Meier failure analysis, history of malignancy, menopausal status, age, and the site of the OLP lesion were significant factors affecting clinical outcomes. Conclusions: The treatment outcomes of OLP were significantly influenced by age, history of malignancy, menopausal status, and the site of the OLP lesion, but not by factors related to dexamethasone treatment.

Clinical Experiences and Usefulness of Cervical Posterior Stabilization with Polyaxial Screw-Rod System

  • Hwang, In-Chang;Kang, Dong-Ho;Han, Jong-Woo;Park, In-Sung;Lee, Chul-Hee;Park, Sun-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.311-316
    • /
    • 2007
  • Objective : The objective of this study is to investigate the safety, surgical efficacy, and advantages of a polyaxial screw-rod system for posterior occipitocervicothoracic arthrodesis. Methods : Charts and radiographs of 32 patients who underwent posterior cervical fixation between October 2004 and February 2006 were retrospectively reviewed. Posterior cervical polyaxial screw-rod fixation was applied on the cervical spine and/or upper thoracic spine. The surgical indication was fracture or dislocation in 18, C1-2 ligamentous injury with trauma in 5, atlantoaxial instability by rheumatoid arthritis (RA) or diffuse idiopathic skeletal hyperostosis (DISH) in 4, cervical spondylosis with myelopathy in 4, and spinal metastatic tumor in 1. The patients were followed up and evaluated based on their clinical status and radiographs at 1, 3, 6 months and 1 year after surgery. Results : A total of 189 screws were implanted in 32 patients. Fixation was carried out over an average of 3.3 spinal segment (range, 2 to 7). The mean follow-up interval was 20.2 months. This system allowed for screw placement in the occiput, C1 lateral mass, C2 pars, C3-7 lateral masses, as well as the lower cervical and upper thoracic pedicles. Satisfactory bony fusion and reduction were achieved and confirmed in postoperative flexion-extension lateral radiographs and computed tomography (CT) scans in all cases. Revision surgery was required in two cases due to deep wound infection. One case needed a skin graft due to necrotic change. There was one case of kyphotic change due to adjacent segmental degeneration. There were no other complications, such as cord or vertebral artery injury, cerebrospinal fluid leak, screw malposition or back-out, or implant failure, and there were no cases of postoperative radiculopathy due to foraminal stenosis. Conclusion : Posterior cervical stabilization with a polyaxial screw-rod system is a safe and reliable technique that appears to offer several advantages over existing methods. Further biomechanical testings and clinical experiences are needed in order to determine the true benefits of this procedure.

Intercalary Tricortical Iliac Bone Graft in the Surgical Treatment of Nonunion of Midshaft Clavicular Fractures (쇄골 간부 불유합에서의 개재 삼면피질 장골 이식술)

  • Cho, Chul-Hyun;Jang, Hyung-Gyu
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.32-36
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the radiologic and clinical outcomes after intercalary tricortical iliac bone graft with plate fixation for the nonunion of midshaft clavicular fractures. Material and Methods: Between September 2007 and May 2011, 10 patients who were treated by the intercalary tricortical iliac bone graft, with plate fixation for clavicle nonunion, were studied. The mean follow-up period was 30.7 (12~57) months. After the sclerotic bone was excised to the bleeding cortical bone, we interposed the tricortical iliac bone to provide structural support and restore clavicle length, and then fixed the plate and screws. The radiologic outcomes on the serial plain radiographs and clinical outcomes, according to UCLA, ASES and Quick DASH scores, were analyzed. Results: Bony union was obtained in all cases (100%) and the average union time was 18.4 (14~24) weeks. The average respective UCLA and ASES scores improved from 16.7 and 52.1 preoperatively to 27.4 and 83.6 postoperatively (p<0.05). The average Quick DASH score was 40.5, at the final follow-up. Complications were 2 shoulder stiffness, and one case had removal of device and arthroscopic surgery at 11 months, postoperatively. There were no implant failure or infection. Conclusion: Intercalary tricortical iliac bone graft, with plate fixation for the nonunion of midshaft clavicular fractures, is a good option that can provide structural support and restore clavicle length, as well as high union rate.

Full mouth rehabilitation with a few remaining teeth and implants for a patient with chronic periodontitis: a case report (만성 치주염 환자에서 소수 잔존치와 임플란트를 이용한 전악 수복: 증례 보고)

  • Shin, Eun-Jung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.253-261
    • /
    • 2015
  • Chronic periodontitis involves subsequent loss of teeth, and if left untreated, can lead to adjacent teeth drifting and supraeruption of the rest dentition. Careful consideration has to be given when deciding extraction of remaining teeth in treatment of periodontally compromised dentitions. For tooth-supported fixed partial dentures or removable partial dentures, periodontally compromised teeth are extracted due to possible early failure from functional overload, but for implant restoration, the teeth could be used as supports for fixed partial dentures because implants can reduce overload on teeth. The remaining natural teeth can help clinicians restoring vertical dimension and normal occlusal plane in full mouth rehabilitation because it conserves patients' proprioceptive response. This clinical report describes treatment of a patient who has a few remaining teeth and supraeruption of the rest dentition from severe chronic periodontitis. Satisfactory clinical result was achieved with full mouth rehabilitation using a few teeth and implants.

Mandibular reconstruction with a ready-made type and a custom-made type titanium mesh after mandibular resection in patients with oral cancer

  • Lee, Won-bum;Choi, Won-hyuk;Lee, Hyeong-geun;Choi, Na-rae;Hwang, Dae-seok;Kim, Uk-kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.35.1-35.7
    • /
    • 2018
  • Background: After the resection at the mandibular site involving oral cancer, free vascularized fibular graft, a type of vascularized autograft, is often used for the mandibular reconstruction. Titanium mesh (T-mesh) and particulate cancellous bone and marrow (PCBM), however, a type of non-vascularized autograft, can also be used for the reconstruction. With the T-mesh applied even in the chin and angle areas, an aesthetic contour with adequate strength and stable fixation can be achieved, and the pores of the mesh will allow the rapid revascularization of the bone graft site. Especially, this technique does not require microvascular training; as such, the surgery time can be shortened. This advantage allows older patients to undergo the reconstructive surgery. Case presentation: Reported in this article are two cases of mandibular reconstruction using the ready-made type and custom-made type T-mesh, respectively, after mandibular resection. We had operated double blind peer-review process. A 79-year-old female patient visited the authors' clinic with gingival swelling and pain on the left mandibular region. After wide excision and segmental mandibulectomy, a pectoralis major myocutaneous flap was used to cover the intraoral defect. Fourteen months postoperatively, reconstruction using a ready-made type T-mesh (Striker-Leibinger, Freibrug, Germany) and iliac PCBM was done to repair the mandible left body defect. Another 62-year-old female patient visited the authors' clinic with pain on the right mandibular region. After wide excision and segmental mandibulectomy on the mandibular squamous cell carcinoma (SCC), reconstruction was done with a reconstruction plate and a right fibula free flap. Sixteen months postoperatively, reconstruction using a custom-made type T-mesh and iliac PCBM was done to repair the mandibular defect after the failure of the fibula free flap. The CAD-CAM T-mesh was made prior to the operation. Conclusions: In both cases, sufficient new-bone formation was observed in terms of volume and strength. In the CAD-CAM custom-made type T-mesh case, especially, it was much easier to fix screws onto the adjacent mandible, and after the removal of the mesh, the appearance of both patients improved, and the neo-mandibular body showed adequate bony volume for implant or prosthetic restoration.