A study on the compatibility of implant drivers (임플란트 드라이버의 호환성에 대한 연구)

  • Kim, Min-Soo;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.34-41
    • /
    • 2014
  • Purpose: In this study, the diameter of each implant driver was measured and compared to find out the compatibility of implant drivers. Materials and methods: Drivers from 12 implant systems being used in Dankook University Dental Hospital were included in this study. The shapes of the implant drivers were segregated, and the effective length and the diameter of upper, middle, lower part of driver tips were measured (n=10). The measured data were mathematically analyzed for its compatibility. Results: A driver with the smallest diameter (1.17 mm) had the highest compatibility at the upper part of driver tip. This driver could be used for a bigger driver up to 1.35 mm in diameter. There were several driver groups which had the same diameter so as to be interchangeable each other. In the middle part, the smallest diameter measured was 1.2 mm and this was able to replace a driver up to 1.40 mm diameter. Since the diameter generally became thicker from upper part (the tip of driver) to the lower part (the shank of driver), some drivers with bigger diameter at the upper part so which was failed to show any compatibility became compatible with a driver which had smaller diameter at the upper part but wider in the middle part. The compatibility of torx shape drivers were affected by the inner diameter of the drivers not only by the outer diameter. Furthermore, the inner diameter of torx drivers decided the compatibility between torx and hex drivers. Conclusion: From the study it was found that compatibility in drivers existed among certain implant systems and to check its compatibility the diameter at a certain effective length should be measured. However, there has been not enough studies about long-term use of compatible drivers, so effects of using compatible drivers on drivers and implants are unknown. Therefore, usage in inevitable cases only is recommended and further study is needed.

FINITE ELEMENT ANALYSIS OF FIN-TYPE IMPLANT FIXTURES (Fin type 임플랜트 고정체의 유한요소법적 분석)

  • Kim, Su-Gwan;Chon, Chang-Gil;Hwang, Gab-Woon;Kim, Byung-Ock
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.14-25
    • /
    • 2003
  • The purpose of this study was to analyze the stress pattern in different bone densities surrounding fin-type implant fixtures under the vertical and inclined loads ($30^{\circ}) of 200N. Von-Mises stress, the pricipal stress, and the displacement on the implant fixtures under the loads were calculated by using the finite element method. Four different types of bicon implant fixture were used for this study. The geometries of implant fixtures to develop the model were used by a sales brochure and profile project. Three-dimensional finite element model of the mandible was developed with 6.0 mm implant in diameter wurrounded by approximately 2.5 mm of bone. Bone densities were classified according to the elastic modulus of the tree. The finite element program MSC PATRAN (MSC, Software Corp., USA) were used for analysis of stress distribution. The value of the Von-Mises stress, the pricipal stress, and the displacement on the implant fixtures under the vertical and inclined loads were decreased when the diameter of implant fixture was increased, and increased when the elastic modulus was decreased. The stress on implant fixture under the vertical and inclined loads was distributed through the length of implant fixtures in D3 and D4. The distribution of stress was influenced by the direction of loads. In the wide diameter of implants, the stress was developed at outer surface of bone. In conclusion, this study suggest that stress developing on the peri-implant tissues might be influenced by the dimension of implant, elastic modulus of bone, and direction of loads.

Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study

  • Lee, Jungwon;Pyo, Se-Wook;Cho, Hyun-Jae;An, Jung-Sub;Lee, Jae-Hyun;Koo, Ki-Tae;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.1
    • /
    • pp.56-66
    • /
    • 2020
  • Purpose: A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Methods: Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six pork ribs and 216 bone-level implants measuring 10 mm in height were used. The implant beds were prepared using 1 of the following 3 drilling protocols: 10-mm drilling depth with a 3.5-mm-diameter twist drill, 5-mm drilling depth with a 4.0-mm-diameter twist drill, and 10-mm drilling depth with a 4.0-mm-diameter twist drill. The first 108 implants were external-connection implants 4.0 mm in diameter, while the other 108 implants were internal-connection implants 4.3 mm in diameter. The peak insertion torque (PIT) during implant placement, the stability values obtained with DCA and RFA devices after implant placement, and the peak removal torque (PRT) during implant removal were measured. Results: The intraclass correlation coefficients (ICCs) of the implant stability quotient (ISQ) results obtained using the RFA device at the medial, distal, ventral, and dorsal points were 0.997, 0.994, 0.994, and 0.998, respectively. The ICCs of the implant stability test (IST) results obtained using the DCA device at the corresponding locations were 0.972, 0.975, 0.974, and 0.976, respectively. Logarithmic relationships between PIT and IST, PIT and ISQ, PRT and IST, and PRT and ISQ were observed. The mean absolute difference between the ISQ and IST values on a Bland-Altman plot was -6.76 (-25.05 to 11.53, P<0.05). Conclusions: Within the limits of ex vivo studies, measurements made using the RFA and DCA devices were found to be correlated under a variety of stability conditions.

Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures

  • Shim, Hye Won;Yang, Byoung-Eun
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.423-430
    • /
    • 2015
  • PURPOSE. To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth $Ankylos^{(R)}$ implants. MATERIALS AND METHODS. This was a retrospective clinical study that analyzed 450 single $Ankylos^{(R)}$ implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. RESULTS. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05). CONCLUSION. The $Ankylos^{(R)}$ implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.

Case report of a newly designed narrow-diameter implant with trapezoid-shape for deficient alveolar bone (좁은 치조골에서 사다리꼴형 디자인으로 개발된 단폭경임플란트의 증례 보고)

  • Lee, Sa Ya;Goh, Mi-Seon;Ko, Seok-Yeong;Yun, Jeong-Ho
    • The Journal of the Korean dental association
    • /
    • v.56 no.5
    • /
    • pp.263-276
    • /
    • 2018
  • Long-term survival and prognosis of narrow-diameter implants have been reported to be adequate to consider them a safe method for treating a deficient alveolar ridge. The objective of this study was to perform case report of narrow-diameter implants with a trapezoid-shape in anterior teeth alveolar bone. A 50-year-old male patient presented with discomfort due to mobility of all of the maxillary teeth and mandibular incisors. Due to destruction of alveolar bone, four anterior mandibular teeth were extracted. Soft tissue healing was allowed for approximately 3 months after the extraction, and a new design of implant placement was planned for the mandibular incisor area, followed by clinical and radiological evaluation. Implant placement was determined using an R2GATE surgical stent. The stability of the implants was assessed by ISQ measurements at the first and second implant surgery and after prosthetic placement. At 1 and 3 months and 1 year after implantation of the prosthesis, clinical and radiological examinations were performed. Another 50-year-old male patient presented with discomfort due to mobility of the mandibular central incisors. For the same reason as in the first patient, implant placement was carried out in the same way after extraction. ISQ measurements and clinical and radiological examinations were performed as in the previous case. In these two clinical cases, 12 months of follow-up revealed that the implant remained stable without inflammation or additional bone loss, and there was no discomfort to the patient. In conclusion, computer-guided implant surgery was used to place an implant in an optimal position considering the upper prosthesis. A new design of a narrow-diameter implant with a trapezoid-shape into anterior mandibular alveolar bone is a less invasive treatment method and is based on the contour of the deficient alveolar ridge. Through all of these procedures, we were able to reduce the number of traumas during surgery, reduce the operation time and total treatment period, and provide patients with more comfortable treatment.

  • PDF

A 3 year prospective study of survival rate of narrow diameter implants (좁은 직경 임플란트 3년간의 생존율에 관한 후향적 연구)

  • Lee, Sung-Jo;Jung, Sae-Young;Shin, Hyun-Seung;Park, Jung-Chul;Song, Young-Gyun;Cho, In-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.32-38
    • /
    • 2018
  • Purpose: The purpose of present study was to retrospectively analyze the survival rate of narrow diameter implant less than 3.6 mm by initial stability and radiographic measurements. Materials and Methods: In total, 24 patients who received 38 narrow diameter implants (${\leq}3.6mm$ in diameter, ${\geq}7mm$ in length) were enrolled in this retrospective study. The cumulative survival rate was calculated and various factors were investigated according to the implant platform diameter, body diameter, length, position, concomitant use of guided bone regeneration in implant placement and final prosthesis type. Initial stability was investigated with implant stability quotient (ISQ) value. The mesial and distal marginal bone level (MBL) change was calculated with radiography. Results: The overall survival rate was 92.11%. Mean ISQ value and MBL change of survival implants was 66.26 and $0.14{\pm}0.31mm$, respectively. None of the implants with platform diameters larger than the body diameter failed. Conclusion: In conclusion, the findings of present study suggest that narrow diameter implant could be predictable treatment in narrow alveolar ridge.

THE EFFECT OF THE DIFFERENCE OF THE IMPLANT FIXTURE AND ABUTMENT DIAMETER FOR STRESS DISTRIBUTION (임프란트 고정체와 지대주 직경의 차이가 응력분포에 미치는 영향)

  • Jung Jong-Won;Lee Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.583-596
    • /
    • 2004
  • Statement of problem : Stress concentration on the neck bone affects the bone resorption, and finally the implant survival. Purpose: In order to examine the stress distribution on the neck bone and prosthesis abutment for implants, decreasing abutment sizes were used. Material and methods : Axisymmetric models were used to obtain the data required. These models were composed of 4mm implants with 3.4mm and 4mm abutments, 5mm implants with 3.4mm and 5mm abutments and 6mm implants with 3.4mm and 6mm abutments. All abutments were designed to received a 10mm high by 10mm diameter gold crown. Functional element analysis was used to obtain these results using data that consisted of 50 N vertical and 45 degree inclination forces. Results : 1. Changing the diameter of the abutment on the implant affects the effect of the inclination forces more than the effect of the vortical forces. 2. Changing the diameter of the abutment on the implant affect the effect of the inclination forces more than the effect of the vertical forces. 3. Experimentation showed that the larger diameter implants provided a decreased neck bone stress, whereas a larger diameter abutment provided a decrease marginal abutment stress. 4. Experimentation showed that the neck bone and abutment received more stress from inclination forces than vertical forces, Conclusions: By decreasing the size of the abutment on the implant we were able to diminishneck bone stress.

STRESS DISTRIBUTION PATTERN OF THE DIFFERENT DIAMETER AND LENGTH OF SHORT IMPLANTS ACCORDING TO THE BONE QUALITY : 3-D FINITE ELEMENTS ANALYSIS (상이한 골질과 제원에 따른 짧은 임프란트의 응력 분포: 3차원 유한 요소 분석)

  • Kim, Han-Koo;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.116-126
    • /
    • 2009
  • The use of short implants has been accepted risky from biomechanical point of view. However, short implants appear to be a long term viable solution according to recent clinical reports. The purpose of this study was to investigate the effect of different diameter and length of implant size to the different type of bone on the load distribution pattern. Stress analysis was performed using 3-dimensional finite element analysis(3D-FEA). A three-dimensional linear elastic model was generated. All implants modeled were of the various diameter(${\phi}4.0$, 4.5, 5.0 and 6.0 mm) and varied in length, at 7.0, 8.5 and 10.0 mm. Each implant was modeled with a titanium abutment screw and abutment. The implants were seated in a supporting D2 and D4 bone structure consisting of cortical and cancellous bone. An amount of 100 N occlusal load of vertical and $30^{\circ}$ angle to axis of implant and to buccolingual plane were applied. As a result, the maximum equivalent stress of D2 and D4 bones has been concentrated upper region of cortical bone. As the width of implant is increased, the equivalent stress is decreased in cancellous bone and stress was more homogeneously distributed along the implants in all types of bone. The short implant of diameter 5.0mm, 6.0mm showed effective stress distribution in D2 and D4 bone. The oblique force of 100N generated more concentrated stress on the D2 cortical bone. Within the limitations of this study, the use of short implant may offer a predictable treatment method in the vertically restricted sites.