• 제목/요약/키워드: impeller pump

검색결과 339건 처리시간 0.023초

극저비속도 원심펌프의 성능과 내부유동특성에 관한 연구 (A Study on the Performance and Internal Flow Characteristics of a Very Low Specific Speed Centrifugal Pump)

  • 쿠로카와준이치;이영호;최영도
    • 대한기계학회논문집B
    • /
    • 제29권7호
    • /
    • pp.784-794
    • /
    • 2005
  • In the very low specific speed range ($n_s=0.24$ < 0.25, non-dimensional), the efficiency of centrifugal pump designed by a conventional method is very low in common. Therefore, positive-displacement pumps have long been used widely. Recently, since the centrifugal pumps are becoming higher in rotational speed and smaller in size, there expects to develop a new centrifugal pump with a high performance to replace the positive-displacement pumps. The purpose of this study is to investigate the internal flow characteristics of a very low specific speed centrifugal pump and to examine the effect of internal flow pattern on pump performance. The results show that the theoretical head definition of semi-open impeller should be revised by the consideration of high slip factor in the semi-open impeller, and the leakage flow through the tip clearance results in a large effect on the impeller internal flow. Strong reverse flow at the outlet of semi-open impeller reduces the absolute tangential velocity considerably, and the decreased absolute tangential velocity increasese the slip factor with the reduction of theoretical head.

Exit Flow Measurements of a Centrifugal Pump Impeller

  • Hong, Soon-Sam;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제16권9호
    • /
    • pp.1147-1155
    • /
    • 2002
  • Discharge flows from a centrifugal pump impeller with a specific speed of 150 [rpm, m$^3$/min, m] were experimentally investigated. A large axisymmetric collector instead of a volute casing was installed to obtain circumferentially uniform flow, i.e. without interaction of the impeller and the volute. The unsteady flow was measured at the impeller exit and vaneless diffuser using a hot film probe and a pressure transducer. The flow at impeller exit showed pronounced jet-wake flow patterns. The wake, which was on the suction/hub side at high flow rate, became enlarged pitchwisely on both the hub and the shroud side as the flow rate decreases. The pitchwise non-uniformity of the flow rapidly decreased along the downstream and the non-uniformity almost disappeared at radius ratio of 1.18 for medium flow rate. The mean vaneless diffuser flow was reasonably predicted using a one dimensional analysis when an empirical constant was used to specify the skin friction coefficient. The data can be used for a centrifugal pump impeller design and validation of CFD codes and flow modeling.

초저온 산업용 액중펌프 임펠러 설계에 관한 연구 (A Study on the Impeller Design of a Submerged Cryogenic Pump)

  • 권병수;이치우;이중섭
    • 한국기계가공학회지
    • /
    • 제15권6호
    • /
    • pp.136-141
    • /
    • 2016
  • The purpose of this study is to examine the basic design of a submerged cryogenic pump, which is a two stage impeller pump. We limited this study to the impeller design of the submerged pump. We calculated its velocity triangle based on the impeller blade configuration and, in order to check its natural frequency, we carried out a modal test using a finite element method (FEM) analysis. Basically, modal test results had quite similar to FEM analysis.

자오면 고정 형상에서 사류펌프 임펠러 및 디퓨져 날개형상 설계 (Blade Shape Design of Mixed-flow Pump Impellers and Diffusers in a Fixed Meridional Geometry)

  • 김성;최영석;이경용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1203-1208
    • /
    • 2009
  • In this paper, the flow characteristics of the mixed-flow pump impellers and diffusers were numerically predicted by commercial CFD software and DOE(design of experiments). We also discussed how to improve the performance of the mixed-flow pump by designing the impeller and diffuser in the mixed-flow pump. Geometric design variables were defined by the vane plane development which indicates the blade-angle distributions and length of the impeller and the diffusers. Firstly, the design optimization of the defined impeller geometric variables has been done. After that, the flow characteristics were analyzed in the point of incidence angle at the diffuser leading edge for the optimized impeller. Then design of the defined diffuser shape variables has been performed. The reason for the performance improvement was discussed by examining the flow characteristics through the diffuser.

  • PDF

Hydraulic Force and Impeller Evaluation of a Centrifugal Heart Pump

  • Timms, D.L;Tan, A.C.C;Pearcy, M-J;Mcneil, K;Galbraith, A
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.376-381
    • /
    • 2004
  • A rig was constructed to test the performance characteristics and compare the hydraulic forces exerted on a centrifugal type artificial heart impeller. A conventional shaft. seal and bearing system. while driven by a small electric motor. supported the impeller which was separated from the pump casing by a six degree of freedom force transducer (JR3 Ine). Radial (x. y) and axial (z) hydraulic forces were recorded and compared. At physiological operating conditions. the results indicate that the double entry/exit centrifugal pump encounters a smaller radial force and significantly reduced axial thrust. These experimental results are valuable in the design of a magnetic bearing system to suspend the impeller of a centrifugal artificial heart pump. This experimental technique may also be applied to evaluate the required capacity and predict the lifetime of contact bearings in marine pumps.

소형 재생펌프의 3차원 성능 해석에 관한 연구 (3 Dimensional Flow Analysis of Small Regenerative Pump)

  • 강신형;임형수;류수현;심창열
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1600-1607
    • /
    • 2004
  • Performance of a regenerative pump is evaluated based on the calculated through flows using the CFX-TASCflow code. Flow calculations are performed in one vane to vane space of the impeller and side channel. The flow is very complex three dimensional with a strong radial vortex due to centrifugal force and an axial vortex due to re-circulating flow between the impeller and the side channel. Momentum exchange on the plane between the impeller and the side channel are evaluated to estimate design parameters and viscous losses in the pump. The present study contributes to showing the capability of flow simulation of complex flow in the regenerative pump by comparing the calculated performance with the measured value.

원심펌프 임펠러의 성능에 대한 전산해석적 연구 (Computational Study on the Performance of the Impeller in Centrifugal Pump)

  • 김원갑;강신형
    • 한국유체기계학회 논문집
    • /
    • 제3권1호
    • /
    • pp.10-18
    • /
    • 2000
  • This paper reports the impeller performance of centrifugal pump, modified HES65-250. Developed CFD code uses SIMPLE algorithm, power-law scheme, standard $k-{\espilon}$ turbulence model in curvilinear coordinate system. The calculations are conducted for 5 cases, from 0.6 to 1.4 of flow rate ratio with 0.2 increment. The flow characteristics inside of impeller are analysed. The results show that reversal flows exist at the inlet of impeller which have small rotary stagnation pressure. The obtained results are compared with the experimental data at impeller exit and shows good qualitative agreement.

  • PDF

임펠러/벌류트의 상호작용을 이용한 원심펌프의 성능예측 (Performance Analysis on Centrifugal Pump Using Impeller/Volute Interaction)

  • 이기수;최창호;김진한;양수석
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2001년도 춘계 학술대회논문집
    • /
    • pp.203-208
    • /
    • 2001
  • Any circumferential variations of the impeller exit flow conditions influences on the volute inlet flow conditions. All these interactions are strongly coupled phd affect consequently the performance of centrifugal pumps. In this paper, a commercial CFD code, which solves three-dimensional quasi-steady Wavier-Stokes equations with an impeller/volute interaction, is used for the prediction of a centrifugal pump performance. The simplified model of an impeller/volute interaction requires affordable computing time and provides relevant results. As a result, detailed flow structures such as pressure rise, recovery and loss mechanism on the centrifugal pumps are obtained. Especially, hydraulic performances are compared between the case of impeller only and the case of impeller with volute configuration. In addition, pump performance at off-design operation are observed and discussed.

  • PDF

역설계 방법을 적용한 사류펌프의 임펠러 및 디퓨저 설계 (Design of Impeller and Diffuser for Mixed Flow Pump with Inverse Design Method)

  • 이경용;최영석;김준호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1322-1325
    • /
    • 2009
  • The impeller and vane diffuser for the mixed flow pump(NS550) was designed by using meridional selection program and inverse design method. We decided the meridional shape of the impeller from the meridional design parameter, such as the specific speed and maximum diameter at the impeller exit. The meridional shape of vane diffuser was set from the impeller shape, distribution of cross sectional area and maximum diffuser diameter. The angle of impeller blade and diffuser vane was designed by using inverse design method. The predicted overall performance by using commercial CFD code(ANSYS CFX-11) shown good agreement with design goals.

  • PDF

원심펌프 회전차의 성능해석에 대한 전산해석적 연구 (Computational Study on the Performance of the Impeller Centrifugal Pump)

  • 김원갑;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.125-133
    • /
    • 1999
  • This paper reports the impeller performance of centrifugal pump, modified HES65-250. Developed CFD code uses SIMPLE algorithm, power-law scheme, standard k-$\epsilon$ turbulence model in curvilinear coordinate system. The calculations are conducted for 5 cases, from 0.6 to 1.4 of flow rate ratio with 0.2 increment. The flow characteristics inside of impeller are analysed. The results show that reversal flows exist at the inlet of impeller which have small rotary stagnation pressure. The obtained results are compared with the experimental data at impeller exit and shows good qualitative agreement.

  • PDF