• Title/Summary/Keyword: impedance study

Search Result 2,029, Processing Time 0.031 seconds

A Study on the Fabrication of the 4 Port In-Phase High Power Combiner (4포트 동위상 고출력 전력결합기의 구현에 관한 연구)

  • Lee, Young-Sub;Jeon, Joong-Sung;Lee, Seok-Jeong;Ye, Byeong-Duck;Kim, Dong-Il;Hong, Tchang-Hee
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.289-294
    • /
    • 2002
  • The broadband high power 3-way combiner was designed and fabricated for the digital TV repeater. To achieve increase of the bandwidth and the high power capability, Wilkinson type power divider was adopted in our research. First of all, Wilkinson type power divider of equal-split and unequal-split were combined, and the characteristics of the four port in-phase power combiner was simulated for each thickness of dielectric substrates. As the results of simulation, the power combiner fabricated by using dielectric substrate of 120 mil-thickness has the characteristics as follows: insertion loss of less than -651 dB, reflection coefficient of less than -13 dB, isolation among the output ports of less than -15 dB, and pose difference among the output ports of smiler than 13$^{\circ}$. Therefore, this power combiner was possible to improve the limit of microstrip line width due to high impedance, the problem of power loss due to interaction between strip lines in a high power combiner and narrow bandwidth simultaneously. Furthermore, making broadband and high power could be achieved since the fabricated 3-way combiner has good characteristics of insertion loss, the reflection coefficient, separation between ports, and phase difference.

Analysis of Current Limiting Characteristics According to Fault Angles in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (일체화된 삼상 자속구속형 고온초전도 전류제한기의 사고각에 따른 전류제한 특성 분석)

  • Park, Chung-Ryul;Du, Ho-Ik;Yim, Seong-Woo;Hyun, Ok-Bae;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Nam, Gueng-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.255-256
    • /
    • 2006
  • In this paper, we investigated the. characteristics of fault current limiting according to fault angle in the integrated three-phase flux-lock type SFCL in fault types such as the single-line-to-ground fault, the double-line-to-ground fault and the three-line-to-ground fault. When the SFCL is operating under normal condition, the magnetic flux generated between primary and secondary coils of each single phase is canceled out perfectly, so that the impedance of the SFCL is also not generated and the power system can be operated normally without any loss, However, if a fault occurs even in any phase out of three phases, quench happened in SFCL elements and the current flowing secondary coil is restricted abruptly. Finally, the balance of magnetic flux in whole SFCL system is destroyed, and the fault currents in every phase could be limited at the same time irrespective of the fault types. As a result, the developed SFCL in this study were operated normally as expected and the purpose of the integration of 3 phase current limiting was also achieved successfully. However, the fault current limiting characteristics of the SFCL was dependant on the quench characteristics of HTSC elements in each phase, and it was expected that the improvement of the SFCL could be possible through the introduction of HTSC elements which have better critical characteristics.

  • PDF

Effect of Sb/Bi Ratio on Sintering and Grain Boundary Properties of ZnO-Bi2O3-Sb2O3-Mn3O4-Co3O4 Varistor (Sb/Bi비가 ZnO-Bi2O3-Sb2O3-Mn3O4-Co3O4 바리스터의 소결과 입계 특성에 미치는 영향)

  • Hong, Youn-Woo;Lee, Young-Jin;Kim, Sei-Ki;Kim, Jin-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.11
    • /
    • pp.878-885
    • /
    • 2012
  • In this study we aims to examine the co-doping effects of 1/3 mol% $Mn_3O_4+Co_3O_4$ (1:1) on the reaction, microstructure, and electrical properties such as the bulk defects and grain boundary properties of $ZnO-Bi_2O_3-Sb_2O_3$ (ZBS; Sb/Bi=0.5, 1.0, and 2.0) varistors. The sintering and electrical properties of Mn,Co-doped ZBS, ZBS(MCo) varistors were controlled by Sb/Bi ratio. Pyrochlore ($Zn_2Bi_3Sb_3O_{14}$) was decomposed and promoted densification at lower temperature on heating in Sb/Bi=1.0 by Mn rather than Co. Pyrochlore on cooling was reproduced in all systems however, spinel (${\alpha}$- or ${\beta}$-polymorph) did not formed in Sb/Bi=0.5. More homogeneous microstructure was obtained in $Sb/Bi{\geq}1.0$ In ZBS(MCo), the varistor characteristics were improved drastically (non-linear coefficient, ${\alpha}$=30~49), and seemed to form $Zn_i^{..}$(0.17 eV) and $V_o^{\bullet}$(0.33 eV) as dominant defects. From impedance and modulus spectroscopy (IS & MS), the grain boundaries have divided into two types, i.e. the one is tentatively assign to $ZnO/Bi_2O_3(Mn,Co)/ZnO$ (0.47 eV) and the other ZnO/ZnO (0.80~0.89 eV) homojunctions.

Synthesis and Conductive Properties of Li1+xAlxTi2-x(PO4)3 (x = 0, 0.3, 0.5) by Sol-Gel Method (Sol-Gel법에 의한 Li1+xAlxTi2-x(PO4)3 (x = 0, 0.3, 0.5)의 합성 및 전도특성)

  • Moon, Jung-In;Cho, Hong-Chan;Song, Jeong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.22 no.7
    • /
    • pp.346-351
    • /
    • 2012
  • $Li_{1+x}Al_xTi_{2-x}(PO_4)_3$(LATP) is a promising solid electrolyte for all-solid-state Li ion batteries. In this study, LATP is prepared through a sol-gel method using relatively the inexpensive reagents $TiCl_4$. The thermal behavior, structural characteristics, fractured surface morphology, ion conductivity, and activation energy of the LATP sintered bodies are investigated by TG-DTA, X-ray diffraction, FE-SEM, and by an impedance method. A gelation powder was calcined at $500^{\circ}C$. A single crystalline phase of the $LiTi_2(PO_4)_3$(LTP) system was obtained at a calcination temperature above $650^{\circ}C$. The obtained powder was pelletized and sintered at $900^{\circ}C$ and $1000^{\circ}C$. The LTP sintered at $900{\sim}1000^{\circ}C$ for 6 h had a relatively low apparent density of 75~80%. The LATP(x = 0.3) pellet sintered at $900^{\circ}C$ for 6 h was denser than those sintered under other conditions and showed the highest ion conductivity of $4.50{\times}10^{-5}$ S/cm at room temperature. However, the ion conductivity of LATP (x = 0.3) sintered at $1000^{\circ}C$ decreased to $1.81{\times}10^{-5}$ S/cm, leading to Li volatilization and abnormal grain growth. For LATP sintered at $900^{\circ}C$ for 6 h, x = 0.3 shows the lowest activation energy of 0.42 eV in the temperature range of room temperature to $300^{\circ}C$.

Development of a Multichannel Eddy Current Testing Instrument(I) (다중채널 와전류탐상검사 장치 개발(I))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoon, Byung-Sik;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.155-161
    • /
    • 2010
  • Recently, the electromagnetic techniques of the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In this study, the synthesizer module and the analog module which are essential to the ECT system were primarily developed. The developed ECT system is basically a multifrequency type which is able to inject the maximum four frequencies based on the frequency and time domain multiplexing method. Conclusively, we confirmed that the EC signal was processed appropriately in each circuit modules, and the Lissajous EC signal was displayed in the impedance plane.

Assessment of Nutritional Status and Factors Related to Smoking in Adolescent Males -1.Dietary Intakes and Nutritional Assessment of Serum Lipids and Antioxidant Vitamins in Adolescent Male Smokers- (남자 고등학생 흡연장의 영양상태 판정 및 흡연관련 요인분석 -1.식이 섭취 실태와 체내 지질 및 항산화 비타민 영양상태-)

  • 김정희;임재연;김경원
    • Korean Journal of Community Nutrition
    • /
    • v.3 no.3
    • /
    • pp.349-357
    • /
    • 1998
  • This study was done to investigate the effect of adolescent smoking on dietary intakes and nutritional status of serum lipids and antioxidant vitamins. Subjects were 82 somkers whose average pack-year was 0.73, and 85 nonsmokers of male technical high school students in Seoul. Anthropometric measurement was performed and % body fat was also analyzed by Bioelectrical Impedance Fatness Analyzer(GIF-891). Dietary intakes and habits were examined through questionnaires and nutrient intakes were analyzed by Computer Aided Nutritional (CAN) analysis programs. Serum TG and total cholesterol levels were measured by Spotchem sp-4410 and serum HDL-cholesterol levels were measured by test kit. serum vitamin C level was measured by 2,4-dinitrophenylhydrazine method and serum levels of vitamin A and vitamin E were measured by HPLC. All data were statistically analyzed by SAS PC package program. There was a significant difference in body fat percentage and systolic blood pressure while other anthropometric measurements were not different between smokers and monsmokers. Caloric intakes(2335㎉) in adolescent smokers tended to be higher than that of nonsmokers (2,175㎉) but the difference was not statistically significant. Intakes of protein(76.67g) and niacin(16.49㎎) in adolescent male smokers were significantly higher(P<0.05) than those of nonsmokers although other nutrient intakes were not significantly different. Analysis of serum lipids showed that serum HDL-cholesterol level of smokers was significantly different. Analysis of serum lipids showed that serum HDL-cholesterol level of smokers was significantly lower(p<0.05) than that of nonsmokers, whereas other lipid levels were not significantly different. Serum vitamin C level was also significantly lower(p<0.05) in adolescent smokers than in nonsmokers. In addition, serum vitamin E level, which was 7.85㎎/1 in smokers, was lower than that of 9.20㎎/1 in nonsmokers(p<0.05) while serum vitamin A level was not significantly different between the two groups. These results indicate that cigarette smoking in adolescence decreases serum levels of HDL-cholesterol, vitamin C and vitamin E even thoughth their smoking history is very short. (Korean J Community Nutrition 3(3) : 349∼357, 1998)

  • PDF

Comparative Study on Body Fat Distribution in Korean and Japanese Young Female Subjects (한국과 일본여자의 체지방 분포에 관한 연구)

  • 김향숙
    • Journal of Nutrition and Health
    • /
    • v.26 no.5
    • /
    • pp.615-624
    • /
    • 1993
  • The body fat distribution and nutritional state of the Korean and Japanese young female subjects were compared. Three-day individually weighed, dietary intakes and anthropometric measurements were determinded in 48 Korean and 60 Japanese female students. 19 to 23 yr of age, from the divisions of nutritions. The body composition estimates were measured by bioeletrical impedance-total body water(BI-TBW) method. There were no significant difference between the Korean and Japanese young females in body size and body shape. The Korean young females had lower estimated total body fat and internal fat that calculated by BI-TBW method, but there was no great difference between the Korean and the Japanese in subcutaneous fat. In contrast, the Korean young females are reported to have the same total energy expenditure per day as the Japanes young females and the total energy intakes and carbohydrate energy intake ratio per day were significantly higher than those of the Japanese young females. The difference in body fat distribution and energy intakes in Korean, and the role of capsaicin in red pepper are discussed as a possible determinant of the internal fat in the Korean vs the Japanese.

  • PDF

Nutritional Status of Chronic Obstructive Pulmonary Disease Patients according to the Severity of Disease (만성 폐쇄성 폐질환 환자에서 병기에 따른 영양상태 평가)

  • Park, Young-Mi;Yoon, Ho-Il;Sohn, Cheong-Min;Choue, Ryo-Won
    • Journal of Nutrition and Health
    • /
    • v.41 no.4
    • /
    • pp.307-316
    • /
    • 2008
  • The purpose of the study was to investigate nutritional status of chronic obstructive pulmonary disease (COPD) patients and to find out the differences according to the stages of disease. From March to October, 2006, 41 stable male patients of mild to severe COPD patients were recruited from Seoul National University hospital. The patients' of body weight and fat free mass were assessed by bioelectrical impedance analysis. The nutritional status of the patients was also assessed by 3-day recall, index of nutritional quality (INQ), dietary diversity score (DDS), dietary variety score (DVS), food group index pattern and dietary quality index (DQI). The total of 41 patients were classified into three groups, stage I, stage II and stage III groups according to the classification of Global Initiative for Chronic Obstructive Lung Disease (GOLD) standard. The mean age of the patients in each stage were 67.2-66.9 years showing no significant difference. The ratio of $FEV_1$/FVC were $57.5{\pm}7.3$, $46.9{\pm}7.6$ and $38.2{\pm}6.8%$, respectively showing significant differences according to the stages of disease. The fat free mass of the stage II ($48.2{\pm}4.7kg$) and III ($47.3{\pm}4.5kg$) was significantly lower than that of stage I ($53.1{\pm}6.9kg$) patients. There were significant correlation of fat free mass with $FEV_{1}$, and BMI (body mass index) with $FEV_{1}$/FVC ratio (p < 0.05). COPD patients showed the diet-related clinical symptoms of anorexia, dyspnea, dyspepsia, and chewing difficulty. Daily intakes of calorie, K, vitamin $B_2$ and folate of the patients were very low ($83.8{\pm}20.7%$, $58.9{\pm}14.4%$, $70.7{\pm}19.6%$ and $74.4{\pm}10.2%$, respectively) however, they did not significantly different according to the stages of disease. Daily intake of calcium was significantly lower in the stage III patients (p < 0.05). The mean scores of dietary variety score was significantly lower in the stage III patients (p < 0.001). Dietary quality index of the patients were not different among the stages of disease and the scores indicated poor quality of diet. As a summary, we found that body fat free mass, regularity of exercise, frequency of having snacks and dietary variety score were significantly associated with the severity of chronic obstructive pulmonary disease.

Effect of Period of Immersion on Corrosion Potential, Anodic Polarization, and Impedance Characteristics of Reinforced Steel in Mortar (W/C: 0.6) (모르타르(W/C:0.6)의 철근의 부식전위와 양극분극 및 임피던스 특성에 미치는 재령 년수)

  • Jeong, Jae-Hyun;Moon, Kyung-Man;Lee, Sung-Yul;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.327-333
    • /
    • 2016
  • Reinforced concrete structures have found wide usage in land and maritime applications. However, the corrosion of reinforced concrete has been recognized as a serious problem from economic and safety standpoints. In previous studies, the corrosion behavior of the inner steel bar embedded in mortar (W/C: 0.4, 0.5) was investigated using electrochemical methods. In this study, multiple mortar test specimens (W/C: 0.6) with six different cover thicknesses were prepared and immersed in flowing seawater for five years. Subsequently, equations related to the cover thickness, period of immersion, and corrosion characteristics of the embedded steel bar were evaluated using electrochemical methods. Prior to immersion, the corrosion potentials indicated an increase with increasing cover thickness, and after five years, all corrosion potentials demonstrated a trend in the positive direction irrespective of the cover thickness. However, the relationships between the corrosion potential and cover thickness were not in complete agreement. Furthermore, after five years, all of the corrosion potentials indicated values that were nobler compared to those obtained prior to immersion, and their corrosion current densities also decreased compared to their values obtained prior to immersion. It was considered that the embedded steel bar was easily corroded because of the aggression of water, dissolved oxygen, and chloride ions; a higher W/C ratio also assisted the corrosion process. The corrosive products deposited on the surface of the steel bar for five years cast a resistance polarizing effect shifting the corrosion potential in the nobler direction. Consequently, it was considered that the W/C ratio of 0.6 showed nearly same results as those of W/C of 0.4 and 0.5. Therefore, the corrosion potential as well as various parameters such as the cover thickness, period of immersion, and W/C ratio must be considered at once for a more accurate evaluation of the corrosion property of reinforced steel exposed to marine environment for a long period.

Evaluation of Characteristics of Welding Zones Welded with Inconel 718 Filler Metal to Piston Crown Forged Material (피스톤 크라운용 단강에 인코넬 718 용접재료로 용접된 용접부의 특성 평가)

  • Lee, Sung-Yul;Moon, Kyung-Man;Jeong, Jae-Hyun;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.334-340
    • /
    • 2016
  • The combustion chamber of a diesel engine is often exposed to a more serious wear and corrosion environment than other parts of the engine because its temperature increases as a result of using heavy oil of low quality. Therefore, repair and built-up welding methods must be performed on worn or corroded parts of the piston crown, exhaust valve, etc. from an economical point of view. In this study, Inconel 718 filler metal was used in repair welding on the groove of a forged steel specimen for a piston crown, along with built-up welding on the surface of another forged steel specimen. Then, the corrosion characteristics of the weld metal zone for the repair welding and the deposited metal zone for the built-up welding were investigated using electrochemical methods in a 35% H2SO4 solution. The deposited metal zone indicated better corrosion resistance than the weld metal zone, showing a nobler corrosion potential, higher impedance, and smaller corrosion current density. It is considered that metal elements with good corrosion resistance were generally included in the filler metal, and these elements were also greatly involved in the deposited meta by built-up welding, whereas the weld metal consisted of metal elements mixed with both the filler metal and base metal elements because of the molten pool produced by the repair welding. Finally, it is considered that the hardness of the weld metal was increased by the repair welding, whereas the built-up welding improved the corrosion resistance of the deposited metal.