• Title/Summary/Keyword: impedance ratio

Search Result 571, Processing Time 0.024 seconds

Measurements of Radial In-plane Vibration Characteristics of Piezoelectric Disk Transducers (원판형 압전 변환기의 면내 방사 진동 특성 측정)

  • Kim, Dae Jong;Oh, Se Hwan;Kim, Jin Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.13-23
    • /
    • 2015
  • The paper experimentally deals with the radial in-plane vibration characteristics of disk-shaped piezoelectric transducers. The radial in-plane motion, which is induced due to Poisson's ratio in the piezoelectric disk polarized in the thickness direction, was measured by using an in-plane laser vibrometer, and the natural frequencies were measured by using an impedance analyzer. The experimental results have been compared with theoretical predictions obtained by simplified theoretical and finite-element analyses. It appears that the fundamental mode of a piezoelectric disk transducer is a radial mode and its radial displacement distribution from the center to the perimeter is not monotonic but shows maximum slightly apart from the perimeter. The theoretically-calculated fundamental frequencies agree well with the finite-element results for small thickness-to-diameter ratio, and they are accurate within 7 % error for the ratio up to 0.4.

Artificial Magnetic Conductor(AMC) Polarizer Backed Circular-Polarized(CP) Antenna (인공 자기 도체 편파 변환기를 이용한 원형 편파 안테나)

  • Chang, Ki-Hun;Ahn, Ji-Hwan;Yoon, Young-Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.5
    • /
    • pp.459-467
    • /
    • 2010
  • A new type of circularly polarized(CP) antenna that is characterized by having both low-profile and greater axial-ratio bandwidth(ARBW) beyond existing antennas is introduced through analysis of artificial magnetic conductor(AMC) polarizer, and experimentally demonstrated. Although it is made use of a linear-polarized dipole antenna with close proximity to ground plane, it is backed by AMC polarizer so as to efficiently radiate with circularly changed polarization whose ARBW is determined by the texture geometry, whereas existing antennas exhibit CP surface-current on radiators, which limit ARBW. The mechanism of the polarization conversion is theoretically analyzed for ARBW, and the experimental properties including the impedance matching, CP radiation pattern, axial-ratio pattern, ARBW, and two-port isolation are discussed.

Development of a Low-Noise Amplifier System for Nerve Cuff Electrodes (커프 신경전극을 위한 저잡음 증폭기 시스템 개발)

  • Song, Kang-Il;Chu, Jun-Uk;Suh, Jun-Kyo Francis;Choi, Kui-Won;Yoo, Sun-K.;Youn, In-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.45-54
    • /
    • 2011
  • Cuff electrodes have a benefit for chronic electroneurogram(ENG) recording while minimizing nerve damage. However, the ENG signals are usually contaminated by electromyogram(EMG) activity from the surrounding muscle, the thermal noise generated within the source resistance, and the electric noise generated primarily at the first stage of the amplifier. This paper proposes a new cuff electrode to reduce the interference of EMG signals. An additional middle electrode was placed at the center of cuff electrode. As a result, the proposed cuff electrode achieved a higher signal-to-interference ratio compared to the conventional tripolar cuff. The cuff electrode was then assembled together with closure, headstage, and hermetic case including electronic circuits. This paper also presents a lownoise amplifier system to improve signal-to-noise ratio. The circuit was designed based on the noise analysis to minimize the electronic noise. The result shows that the total noise of the amplifier was below $1{\mu}V_{rms}$ for a cuff impedance of $1\;k{\Omega}$ and the common-mode rejection ratio was 115 dB at 1 kHz. In the current study, the performance of nerve cuff electrode system was evaluated by monitoring afferent nerve signals under mechanical stimuli in a rat animal model.

Variance of Initial Fault Current Limiting Instant in Flux-lock Type SFCL (자속구속형 전류제한기의 초기 사고전류 제한시점 변화)

  • Park, Chung-Ryul;Lim, Sung-Hun;Park, Hyoung-Min;Choi, Hyo-Sang;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.3
    • /
    • pp.269-275
    • /
    • 2005
  • A flux lock-type SFCL consists of two coils which are wound in parallel each other through an iron core, and a HTSC thin film connects in series with coil 2. The operation of the flux-lock type SFCL can be divided into the subtractive polarity winding and the additive polarity winding operations according to the winding directions between coil 1, coil 2. When a fault occurs, the fault current in the HTS thin film exceeds the critical current so that resistance is generated in the HTS film, and thereby the fault current is limited by an instant rise in the impedance of the flux-lock type SFCL. We investigated he variances of initial fault current limiting instant according to the ratio of inductance of coil 1 and coil 2 in the flux-lock type SFCL. It was confirmed from experiments that the initial fault current limiting instant in the subtractive polarity and additive polarity windings were faster as the ratio of coil 2' inductance for coil 1's inductance increased. The 1st peak of fault current in case of the subtractive polarity winding was higher as the ratio of coil 2's inductance for coil 1's inductance increased. On the other hand, in case of the additive polarity winding, the 1st peak of fault current was lower.

Measurement Method of Noise Correlation Matrix Using Relative Noise Ratio (상대적인 잡음비를 이용한 잡음상관행렬 측정방법)

  • Lee, Dong-Hyun;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.430-437
    • /
    • 2016
  • In general, noise measurement results show larger random ripple than those of the network analyzer. The reason for the lager random ripple of the noise measurements is considered that the general noise measurements uses absolute measured noise powers, while the network analyzer measures using a ratio of the measured powers. In this paper, a novel measurement method of noise correlation matrix using relative noise ratios is proposed. Proposed method measures the five noise powers of DUT for the five input impedance variations and the four relative noise ratios are formed using the five measured noise powers. The four noise ratios are used to compute the noise correlation matrix and noise parameters. The resulting noise parameters for a 0.5 dB attenuator show good agreements with theoretical values calculated by S-parameters. Also, the noise parameters of an active DUT with a noise figure of less than 1 dB are measured and the measured results show a small random ripple as expected and their values are physically acceptable. In conclusion, the proposed method can be applied to the noise parameter measurements for DUT with a noise figure below 1 dB.

Study on Muscle Circumference Among Groups Divided by Body Mass Index(BMI) (Body Mass Index(BMI) 분류에 따른 그룹들 간 근육둘레비율의 상관성 연구)

  • Kim, Dong-Gun;Cha, Yun-Yeop;Park, Won-Hyung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.4
    • /
    • pp.1099-1103
    • /
    • 2005
  • This study aims to confirm the importance of behavior habit and exercise, especially leg exercise in obese. Out of 889 people, We divided Group A 50 (BMI<18.5), Group B 210 $(18.5{\leq}BMl<23)$, Group C 202 $(23{\leq}BMI<25)$, Group D212 $(25{\leq}BMI<30)$ and Group 1215 (30

Performance Analysis with Various Amounts of Electrolyte in a Molten Carbonate Fuel Cell

  • Kim, Yu-Jeong;Kim, Tae-Kyun;Lee, Ki-Jeong;Lee, Choong-Gon
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.234-240
    • /
    • 2016
  • The effect of initial electrolyte loading (IEL) on cell performance in a coin-type molten carbonate fuel cell (MCFC) was investigated in this work. Since the material of MCFC depends on the manufacturer, optimisation requires experimental investigation. In total, four IEL values, 1.5, 2.0, 3.0, and 4.0 g, were used, corresponding to a pore filling ratio (PFR) of 38, 51, 77, and 102%, respectively. The cell performance with respect to the PFR was analysed via steady-state polarisation, step-chronopotentiomtery, and impedance methods. The electrochemical analyses revealed that internal resistance and overpotential of the cell decreased with increasing PFR, and a large overpotential was observed when the PFR was 102%, probably due to the flooding phenomenon. After operation, cross-section of the cell was analysed via surface analysis of SEM and EDS methods, and the remaining electrolyte was estimated by dissolution of the cell in 10 wt% acetic acid. A linear relationship between IEL and the weight reduction ratio by dissolution was obtained. Thus, the remaining amount of electrolyte could be measured after operation. The results of SEM and EDS showed that a PFR of 38 and 102% showed a lack and flooding of electrolytes at the cell, respectively, which led to a large overpotential. This work reports that MCFC performance is allowed only in the narrow range of PFR.

Design of a Broadband Series-Fed Bow-tie Dipole Pair Antenna for Mobile Base Station (이동통신 기지국용 광대역 직렬 급전 보우타이 다이폴 쌍 안테나 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1445-1450
    • /
    • 2013
  • In this paper, a broadband series-fed bow-tie dipole pair (SBDP) antenna operating in the band of 1.7-2.7 GHz for mobile communication base station applications is proposed. The proposed antenna uses bow-tie-shaped dipole elements instead of straight strip dipole ones used in a conventional series-fed dipole pair (SDP) antenna. The simulation results show that the lowest operating frequency is shifted toward lower frequency as the flare angle increases, and so the lengths of the bow-tie dipole elements can be reduced in proportion to the frequency shift toward lower frequency. An SBDP antenna with a flare angle of 10 degrees is fabricated on an FR4 substrate (dielectric constant = 4.4 and thickness = 1.6 mm) and total width of the fabricated antenna is reduced by 10% compared to that of the conventional SDP antenna. The measured impedance bandwidth for voltage standing wave ratio (VSWR) < 2 is 48.8% (1.69-2.78 GHz), gain is 5.8-6.3 dBi, and the front-to-back ratio (FBR) is 14-17 dB.

Dual-Band Unequal Power Divider based on CRLH Transmission Line (CRLH 전송선로를 기반으로 한 이중대역 비대칭 전력 분배기)

  • Yoo, Jae-Hyun;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.909-915
    • /
    • 2010
  • In this paper, the unequal power divider based on CRLH (Composite Right/Left-Handed) transmission line with dual-band characteristic is proposed. They consist of dual-band branch line hybrid coupler, the connection between input and isolation port of hybrid coupler and ${\lambda}/4$ impedance transformer. When the transmission line between input and isolation port of hybrid coupler is asymmetrical connected, the divider is obtained the output results of the equal phase and unequal power dividing ratio. The simulation results of the divider represent the power ratio of 0 dB ~ 20 dB. To validate a function of divider, the hybrid coupler and transformer with 880 MHz and 1850 MHz is implemented. As a result, the proposed unequal divider obtains the power ratio of 3.2 dB ~ 8.8 dB at 880 MHz and 2.5 dB ~ 14.0 dB at 1850 MHz.

Damping of a taut cable with two attached high damping rubber dampers

  • Cu, Viet Hung;Han, Bing;Wang, Fang
    • Structural Engineering and Mechanics
    • /
    • v.55 no.6
    • /
    • pp.1261-1278
    • /
    • 2015
  • Due to their low intrinsic damping, stay cables in cable-stayed bridges have often exhibited unanticipated and excessive vibrations which result in increasing maintenance frequency and disruption to normal operations of the entire bridges. Mitigation of undesired cable vibration can be achieved by attaching an external damping device near the anchorage. High Damping Rubber (HDR) dampers have many advantages such as compact size, better aesthetics, easy maintenance, temperature stability, and cost benefits; therefore, they have been widely used to increase cable damping. Although a single damper has been shown to reduce cable vibrations, it is not the most effective method due to geometric constraints. This paper proposes the use of two HDR dampers to improve effectiveness and robustness in suppressing cable vibration. Oscillation parameters of the cable-dampers system were investigated in detail by modeling the stay cable as a taut string and each HDR damper as complex-valued impedance and by using an analytical formulation of the complex eigenvalue problem. The problem of two HDR dampers arbitrarily located along a cable is solved and the solution is discussed. Asymptotic formulas to calculate the damping ratios of the cable with two HDR dampers installed near the anchorage(s) are proposed and compared with the exact solutions. Further, a design example is presented in order to justify the methodology. The results of this study show that when the two HDR dampers are installed close to each other on the same end of the cable, some interaction between the dampers leads to reduced damping ratio. When the dampers are on the opposite ends of the cable, they are effective in increasing damping ratio and can provide better vibration reduction to multiple modes.