80-MW 클라이스트론 부하용 200-MW 펄스 트랜스포머의 성능시험 (Performance Test of 200-MW Pulse Transformer for 80-MW Klystron Load)

  • 장성덕;오종석;손윤규;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2167-2169
    • /
    • 1999
  • A pulse transformer producing pulses with the peak power of 200-MW (400 kV 500 A at load side with $4.4{\mu}s$ flat-top) is required to drive the 80-MW pulsed klystron in the PLS linac. We have designed and manufactured the high power pulse transformer with 1 : 17 turn ratio. Its primary functions are to match the impedance of klystron tube to the modulators, and to provide step-up of the voltage. To obtain a fast rise time of the pulse voltage. Low leakage inductance and low distributed capacitance design is very important. In this paper, we discuss the equivalent circuit analysis of the pulse transformer, and present the full power performance test results of pulse transformer.

  • PDF

펄스 플라즈마 반응기의 모델링 (Modelling of Pulsed Plasma Reactor)

  • 최영욱;이홍식;임근희;김태희;정종한;김종화;장길홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2013-2015
    • /
    • 1999
  • The pulsed plasma wire-plate reactor was modelled on the basis of experiment and EMTP simulation. The electrical phenomena in reactor is consistent with the model we suggested. Using this model, the influence of the reactor capacitance on the impedance matching between pulse generator and reactor can be analyzed. From this, we found that the energy of 95 % was delivered from pulse generator to reactor at the ratio of $C_p$/$C_r$ $\cong$ 30 %, where $C_p$ is pulse generator capacitance, $C_r$ is reactor capacitance.

  • PDF

유한차분 시간영역법을 이용한 갭 결합 마이크로 스트립 패치안테나의 설계 및 해석 (Design and Analysis of Gap Coupled Microstrip Patch Antenna using the FDTD method)

  • 신호섭
    • 디지털콘텐츠학회 논문지
    • /
    • 제10권3호
    • /
    • pp.389-393
    • /
    • 2009
  • 본 논문에서는 유한차분 시간영역법(Finite Difference Time Domain method)을 이용하여 단일 패치를 갖는 마이크로스트립 안테나와 2개의 패치를 갖는 광대역 갭 결합 마이크로스트립 패치안테나를 설계 및 해석하였다. 반사파를 최소로 하기 위해 Mur의 2차 흡수경계조건을 적용하였다. 이 안테나의 구동패치의 길이와 폭, 기생패치의 길이와 폭, 구동패치와 기생패치의 간격 등에 의한 반사손실, 전압정재파비, 입력 임피던스 등의 주파수 응답 특성을 해석하여 최적의 광대역 안테나의 설계치를 보여 주었고 이로부터 복사패턴을 제시하였다. 또한 광대역 안테나 특성이 일어나는 원인을 분석하였다.

  • PDF

EDLC용 폴리머 겔 전해질 (Polymer Gel Electrolytes for EDLCs)

  • 정세일;정현철;강안수
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2003년도 추계학술대회
    • /
    • pp.351-357
    • /
    • 2003
  • The optimum polymer gel electrolyte composition ratio was 23 : 66 : 11 wt% of P(VdF-co-HFP) : PVP =20 : 3), (PC: EC =44 : 22) and TEABF$_4$. And the optimal thickness of polymer gel electrolyte was 50 ${\mu}{\textrm}{m}$. The electrochemical characteristics result of unit cell were 31.41 Fig of specific capacitance, and 3.21$\times$10$^{-3}$ S/cm of ion conductivity. Ion conductivity of polymer gel electrolytes decreased according to added PVP through impedance analysis, and it was higher in 7 wt%, but electrochemical characteristics of unit cell were better in 3 wt% PVP. And for excellent ion conductivity of polymer gel electrolytes, the use of a thin layer electrolyte(20 $\mu\textrm{m}$) was an effective method, but with unit cell application, the best thickness was 50 $\mu\textrm{m}$. Unit cell showed higher capacitance and more stable electrochemical performance when hot pressed between polymer gel electrolyte and electrode. This results from enhancement of the physical contact between the electrode and the polymer gel electrolyte and good accessibility of the liquid electrolyte to the electrode surface.

  • PDF

Effect of Microstructure on Corrosion Behavior of TiN Hard Coatings Produced by Two Grid-Attached Magnetron Sputtering

  • Kim, Jung Gu;Hwang, Woon Suk
    • Corrosion Science and Technology
    • /
    • 제5권1호
    • /
    • pp.15-22
    • /
    • 2006
  • The introduction of two-grid inside a conventional process system produces a reactive coating deposition and increases metal ion ratio in the plasma, resulting in denser and smoother films. The corrosion behaviors of TiN coatings were investigated by electrochemical methods, such as potentiodynamic polarization test and electrochemical impedance spectroscopy (EIS) in deaerated 3.5% NaCl solution. Electrochemical tests were used to evaluate the effect of microstructure on the corrosion behavior of TiN coatings exposed to a corrosive environment. The crystal structure of the coatings was examined by X-ray diffractometry (XRD) and the microstructure of the coatings was investigated by scanning electron microscopy (SEM) and transmission electron spectroscopy (TEM). In the potentiodynamic polarization test and EIS measurement, the corrosion current density of TiN deposited by two grid-attached magnetron sputtering was lower than TiN deposited by conventional magnetron type and also presented higher Rct values during 240 h immersion time. It is attributed to the formation of a dense microstructure, which promotes the compactness of coatings and yields lower porosity.

An RFID Tag Using a Planar Inverted-F Antenna Capable of Being Stuck to Metallic Objects

  • Choi, Won-Kyu;Son, Hae-Won;Bae, Ji-Hoon;Choi, Gil-Young;Pyo, Cheol-Sig;Chae, Jong-Suk
    • ETRI Journal
    • /
    • 제28권2호
    • /
    • pp.216-218
    • /
    • 2006
  • This letter presents the design for a low-profile planar inverted-F antenna (PIFA) that can be stuck to metallic objects to create a passive radio frequency identification (RFID) tag in the UHF band. The designed PIFA, which uses a dielectric substrate for the antenna, consists of a U-slot patch for size reduction, several shorting pins, and a coplanar waveguide feeding structure to easily integrate with an RFID chip. The impedance bandwidth and maximum gain of the tag antenna are about 0.3% at 914 MHz for a voltage standing wave ratio (VSWR) of less than 2 and 3.6 dBi, respectively. The maximum read range is about 4.5 m as long as the tag antenna is on a metallic object.

  • PDF

Fully Integrated HBT MMIC Series-Type Extended Doherty Amplifier for W-CDMA Handset Applications

  • Koo, Chan-Hoe;Kim, Jung-Hyun;Kwon, Young-Woo
    • ETRI Journal
    • /
    • 제32권1호
    • /
    • pp.151-153
    • /
    • 2010
  • A highly efficient linear and compactly integrated series-type Doherty power amplifier (PA) has been developed for wideband code-division multiple access handset applications. To overcome the size limit of a typical Doherty amplifier, all circuit elements, such as matching circuits and impedance transformers, are fully integrated into a single monolithic microwave integrated circuit (MMIC). The implemented PA shows a very low idle current of 25 mA and an excellent power-added efficiency of 25.1% at an output power of 19 dBm by using an extended Doherty concept. Accordingly, its average current consumption was reduced by 51% and 41% in urban and suburban environments, respectively, when compared with a class-AB PA. By adding a simple predistorter to the PA, the PA showed an adjacent channel leakage ratio better than -42 dBc over the whole output power range.

폴디드 멀티스트립 모노폴 안테나 (Folded Multi-Strip Monopole Antenna)

  • 이윤호;정종호;박익모
    • 한국전자파학회논문지
    • /
    • 제14권11호
    • /
    • pp.1127-1133
    • /
    • 2003
  • 본 논문에서는 수직한 스트립의 끝을 ‘ㄷ’형태로 접어 안테나 높이를 줄인 새로운 구조의 폴디드 멀티스트립(folded multi-strip) 모노폴 안테나를 제안하였다. 안테나는 VSWR$\leq$2를 기준으로 하한 주파수 4.55 GHz에서 상한 주파수 8.4 GHz까지 1.85 : 1의 대역비를 갖는 광대역 특성을 나타내고 있다. 전방향으로 동일한 복사이득을 갖는 코니컬 빔의 수평단면 복사패턴을 가지며, 대역폭 내에서 왜곡 없는 안정된 복사패턴 특성을 유지하고 있다.

An Implantable Antenna for Wireless Body Area Network Application

  • Kim, Ui-Sheon;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.206-211
    • /
    • 2010
  • In this paper, an implantable planar inverted-F antenna (PIFA) for an artificial cardiac pacemaker is proposed. The antenna has a simple structure with a low profile and is placed on the top side of the pacemaker. The dimensions of the pacemaker system, including the antenna element, are $42{\times}43.6{\times}11$ mm. When the antenna is embedded in pig tissue, its $S_{11}$ value is -10.94 dB at 403 MHz and the -10 dB impedance bandwidth of the antenna is 6 MHz (399~406 MHz). The proposed PIFA in tissue has a peak gain of -20.19 dBi and a radiation efficiency of 1.12 % at 403 MHz. When the proposed antenna is placed in a flat phantom, its specific absorption ratio (SAR) value is 0.038 W/kg (1 g tissue). Performances of the proposed PIFA is sufficient to operate at the MICS band (402 ~ 405 MHz).

연계선로의 조건 변화에 따른 DFIG와 FSIG 풍력발전시스템의 운전특성 비교 (Comparison of Operating Characteristics for DFIG and FSIG wind Turbine Systems with Respect to Variable Interconnecting Line Conditions)

  • 노경수;김태호
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.8-15
    • /
    • 2010
  • This paper analyzes the steady-state output characteristics of variable-speed wind turbine systems using doubly-fed induction generators(DFIG) compared with fixed-speed induction generator(FSIG) wind turbine systems. It also presents simulations of a grid-connected wind turbine generation system for dynamics analysis on MATLAB/Simulink and compares the responses between DFIG and FSIG wind turbine systems with respect to wind speed variation, impedance changes and X/R ratio changes of interconnecting circuits. Simulation results show the variation of generator's active output, terminal voltage and fault currents at the interconnecting point. Case studies demonstrate that DFIG wind turbine systems illustrate better performance to 3-phase fault than FSIG's.