• 제목/요약/키워드: impedance ratio

검색결과 566건 처리시간 0.027초

CoFeSiBNi 아몰퍼스 합금의 자기-임피던스 효과 (Magneto-impedance effect of CoFeSiBNi amorphous magnetic films)

  • 이승훈;박병규;황성우;문성욱
    • 센서학회지
    • /
    • 제16권5호
    • /
    • pp.389-393
    • /
    • 2007
  • Soft ferromagnetic materials are very useful for many sensors using magnetic materials demanding high permeability, low coercivity and low hysteresis loss. Among them, FeCoSiBNi amorphous magnetic films show a good impedance change (about 5.01 %/Oe, at 10 MHz) by the exterinal magnetic field in this experiment. The magnetic films are produced by melt-spun method, one of the rapid solidification process. Ribbon shape wires were made from the films, and let them annealed in DC magnetic field to increase the maximum Giant Magneto Impedance ratio. Field annealing decreases the stress and changes the effective anisotropy. Thus, we can find that the impedance change (200.47 %) is improved and the fabricated magnetic wire has characteristics of good sensor element.

가진 음압 및 설계 인자에 따른 미세 천공판 흡음 기구의 흡음 특성 (Absorption Characteristics of Micro-perforated Panel Absorber According to Incident Pressure Magnitude and Its Geometric Parameters)

  • 박순홍;서상현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.178-185
    • /
    • 2011
  • The micro-perforated panel absorber (MPPA) is one of promising noise control elements because of its applicability to extreme environments where general porous materials cannot be used. Since the MPPA is inherently non-porous sound absorber, it can be a good candidate of acoustic protection system of a space launcher. The overall sound pressure level inside payload fairings of commercial launch vehicles is so high (around 140 dB OASPL) that the conventional linear impedance model cannot be directly applied to the design of the acoustic protection systems. In this paper an acoustic impedance models of a micro-perforated panel absorber at high sound pressure environment were reviewed and the use of the impedance on the practical design of MPPAs was addressed. The variation of absorption characteristics of MPPA was discussed according to the design parameters, e.g., perforation ratio, the minute hole diameter, the thickness of MPP and the incident sound pressure level.

  • PDF

Super-giant Magneto-Impedance Effect of a LC-resonator Using a Glass-Coated Amorphous Microwire

  • Lee, Heebok;Kim, Yong-Seok;Yu, Seong-Cho
    • Journal of Magnetics
    • /
    • 제7권4호
    • /
    • pp.160-164
    • /
    • 2002
  • A new discovery of the super-giant magneto-impedance (SGMI) effect was found out in a LC-resonator consisted of a glass-coated amorphous $CO_{83.2}B_{3.3}Si_{5.9}Mn_{7.6}$ microwire. The measurement was carried out at high frequency range from 100 MHz up to 1 GHz of an ac-current flowing along the wire and at varying axial dcmagnetic field in its range of $\pm$120 Oe. The wires, about 16${\mu}m$ in diameter, were fabricated by a glass-coated melt spinning technique. The shape of the impedance curves plotted vs. a dc-field is changing dramatically with the frequency. The phase angle was also strongly dependent on this field. The external dc-magnetic field changes the circumferential permeability as well as the penetration depth, both in turn change the impedance of the sample. The drastic increments of SGMI at high frequency can be understood in terms of the LC-resonance phenomena. The sudden change of the phase angle, as large as $180^{\circ}$ evidenced the occurrence of the resonance at a given intensity of the external dc-field. The maximum ratio of SGMI reached in the experiment by precise tuning frequency equals 450,000% at the frequency of around 551.9075 MHz.

임피던스 변화를 이용한 선형 대기압 DBD 플라즈마 밀도 측정 (Plasma Density Measurement of Linear Atmospheric Pressure DBD Source Using Impedance Variation Method)

  • 신기원;이환희;권희태;김우재;서영철;권기청
    • 반도체디스플레이기술학회지
    • /
    • 제17권2호
    • /
    • pp.16-19
    • /
    • 2018
  • The development speed of semiconductor and display device manufacturing technology is growing faster than the development speed of process equipment. So, there is a growing need for process diagnostic technology that can measure process conditions in real time and directly. In this study, a plasma diagnosis was carried out using impedance variation due to the plasma discharge. Variation of the measurement impedance appears as a voltage change at the reference impedance, and the plasma density is calculated using this. The above experiment was conducted by integrating the plasma diagnosis system and the linear atmospheric pressure DBD plasma source. It was confirmed that plasma density varies depending on various parameters (gas flow rate, $Ar/O_2$ mixture ratio, Input power).

가소제 혼합비에 따른 PAN/PVDF계 고분자 전해질의 이온 전도 특성 (Conductivity of PAN/PVDF based Polymer Electrolyte as a Function of Plasticizer Mixed Ratio)

  • 이재안;김종욱;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.261-264
    • /
    • 2000
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li polymer battery. This paper describes temperature dependence of conductivity, impedance spectroscopy, electrochemical properties of PAN/PVDF electrolytes as a function of a mixed ratio. PAN/PVDF based polymer electrolyte films were prepared by thermal gellification method of preweighed PAN/PVDF, plasticizer and Li salt. By adding PVDF and as a function of plasticizer mixed ratio to PAN-LiClO4 electrolyte, its conductivity was higher than that of PAN-$LiClO4_4$ electrolyte. The conductivity of PAN/PVDF electrolytes was $10^{-3}S/cm$. $10PAN10PVDFLiClO_4PC_5EC_5$ electrolyte shows the better conductivity of the others. Steady state current method and ac impedance used for the determination of transference numbers in PAN/PVDF electrolyte film. The transference number of $10PAN10PVDFLiClO_4PC_5EC_5$ electrolyte is 0.45.

  • PDF

캐패시터가 주기적으로 병렬 연결된 전송선로를 이용한 비대칭 분배기 (An Unequal Divider based on Transmission Line with Periodic Capacitor Shunt Connection)

  • 김영;윤영철
    • 한국항행학회논문지
    • /
    • 제16권5호
    • /
    • pp.781-786
    • /
    • 2012
  • 본 논문에서는 캐패시터가 주기적으로 병렬 연결된 전송선로를 이용한 높은 분배 비율을 갖는 비대칭 분배기의 설계와 성능을 제안하였다. 높은 분배 비율을 갖는 분배기에서 요구되는 높은 임피던스 값은 마이크로스트립 선로로 구현 가능한 값으로 제한하였고, 낮은 임피던스 값은 캐패시터가 주기적으로 병렬 연결된 전송선로를 이용하여 설계하였다. 이러한 설계 방법은 선로 임피던스 값이 $10{\Omega}$ 이하의 전송선로를 마이크로 스트립으로 구현 가능하게 하였다. 이러한 설계 방법을 증명하기 위해서 중심주파수 1 GHz이고, 분배 비율이 10:1인 비대칭 분배기를 구현하였으며, 그 결과는 시뮬레이션과 1dB 이내에서 일치함을 보였다.

A new damage identification approach based on impedance-type measurements and 2D error statistics

  • Providakis, Costas;Tsistrakis, Stavros;Voutetaki, Maristella;Tsompanakis, Yiannis;Stavroulaki, Maria;Agadakos, John;Kampianakis, Eleftherios;Pentes, George
    • Structural Monitoring and Maintenance
    • /
    • 제2권4호
    • /
    • pp.319-338
    • /
    • 2015
  • The electro-mechanical impedance (EMI) technique makes use of surface-bonded lead zirconate titanate (PZT) patches as impedance transducers measuring impedance variations monitored on host structural components. The present experimental work further evaluate an alternative to the conventional EMI technique which performs measurements of the variations in the output voltage of PZT transducers rather than computing electromechanical impedance (or admittance) itself. This paper further evaluates a variant of the EMI approach presented in a previous work of the present authors, suitable, for low-cost concrete structures monitoring applications making use of a credit card-sized Raspberry Pi single board computer as core hardware unit. This monitoring approach is also deployed by introducing a new damage identification index based on the ratio between the area of the 2-D error ellipse of specific probability of EMI-based measurements containment over that of the 2-D error circle of equivalent probability. Experimental results of damages occurring in concrete cubic and beam specimens are investigated under increasing loading conditions. Results illustrate that the proposed technique is an efficient approach for identification and early detection of damage in concrete structures.

임피던스법을 이용한 혈압 및 혈류 변화량 검출 시스템 구현 (Implementation of the Blood Pressure and Blood Flow Variation Rate Detection System using Impedance Method)

  • 노정훈;배진우;예수영;신범주;전계록
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.1926-1938
    • /
    • 2009
  • 본 연구에서는 혈압 측정 시 생체 임피던스가 변화하는 현상을 이용하여 혈류량 변화를 검출하는 시스템을 구현하였다. 혈압의 측정은 오실로메트릭법을 적용하였으며, MAA 알고리즘을 이용하여 평균 동맥압을 산출한 후 평균 동맥압에 대한 여러 가지 특성비율을 설정하여 수축기 및 이완기 혈압을 추정하였다. 인체 임피던스 측정은 교류 정전류원과 락인-증폭기를 이용하였으며, 측정 부위에 인가되는 커프 압력에 의해 생체 임피던스 변화량을 이용하여 혈류량 변화를 측정하였다.

스텝 Perturbation의 영향에 따른 주기적 스텝 임피던스 링 공진기의 해석 및 이중 모드 대역 통과 필터의 적용 (Analysis of Periodic Stepped Impedance Ring Resonator by the Effect of Step Perturbation and Application of Dual-Mode Bandpass Filter)

  • 이주갑;이우성;류재종;문연관;김하철;최현철
    • 한국전자파학회논문지
    • /
    • 제18권7호
    • /
    • pp.739-747
    • /
    • 2007
  • 스텝 임피던스 비를 조정한 스텝 perturbation을 가지는 주기적 스텝 임피던스 링 공진기를 이용하여 이중 모드 대역 통과 필터를 설계하였다. 주기적 스텝 임피던스 링 공진기는 특성 임피던스의 비를 변경함으로써 크기 감소와 2차 하모닉 억압 효과를 얻을 수 있다. 이중 모드의 발생을 위한 perturbation 또한 특성 임피던스의 비로 쉽게 조정하였으며, 그 영향에 따른 이중 모드 공진 주파수 및 감쇄 극 주파수의 변화를 분석하였다. 입출력 결합은 칩 커패시터를 사용하였으며, 결합 커패시턴스와 스텝 perturbation의 영향에 따른 중심 주파수의 변화 또한 고려되었다. 그 결과로부터 $14{\times}14mm^2$ 크기 내에서 서로 다른 감쇄 극과 대역폭을 가지는 두 종류의 2 GHz 이중 모드 대역 통과 필터들을 제작하였다 제안된 대역 통과 필터들의 측정 결과는 계산된 예상과 매우 유사함을 보였으며 각각 2.52, 0.52 dB의 삽입 손실과 4.03, 15.02 %의 3 dB 대역폭을 가진다.

출력 전력 백-오프 기반 비대칭 도허티 전력 증폭기 (Output Power Back-Off (OPBO) Based Asymmetric Doherty Power Amplifier)

  • 전상현;장동희;김지연;김종현
    • 한국ITS학회 논문지
    • /
    • 제9권2호
    • /
    • pp.51-59
    • /
    • 2010
  • 본 논문에서는 입력신호의 Peak to Average Power Ratio (PAR) 에 따라 원하는 출력전력 백-오프 (Output Power Back-Off, OPBO) 구간에서 최적의 효율특성을 가지는 반전 타입의 비대칭 도허티 전력증폭기의 설계 방법을 제안하였다. 원하는 OPBO 구간에서 비대칭 도허티 전력증폭기의 최적 효율특성을 얻기 위해 주 증폭기와 피킹 증폭기의 피크 전력비를 결정하였고 피크 전력비에 따른 $90^{\circ}$ 임피던스 변환기의 정확한 임피던스 값을 도출 하였다. 또한 비대칭 도허티 전력증폭기 설계시 최적의 성능을 얻기 위해 오프셋 라인의 길이와 전력 분배비를 계산하였다. 측정결과, 비대칭 도허티 전력증폭기는 CDMA 2000 1x 3-FA 테스트 신호에 대해서 평균 출력 전력 48.7 dBm에서 40%의 전력 효율과 -35 dBc의 인접 채널전력비를 얻었다.