• Title/Summary/Keyword: impedance of telecommunication line

Search Result 24, Processing Time 0.027 seconds

Analysis on the Effects of the Induced Noise Voltage with the Impedance Changes of Telecommunication Line in the Power Inducting Situation (전력 유도 장애 발생 시 통신 선로의 접지체 임피던스 크기가 유도 잡음 전압에 미치는 영향 분석)

  • Choi, Mun-Hwan;Lee, Sang-Mu;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.227-230
    • /
    • 2007
  • In this paper, we have analyzed the change characteristics of induced noise due to the impedance change of the ground in both ends of telecommunication line. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. In the result of measurement, we can see the noise level change due to the change of the ground impedance, that is, as the ground impedance at either end of the telecommunication line become grower, the noise level is increased, and as the ground impedance at either end of the telecommunication line become smaller, the noise level is decreased. However, we can't define the relation between ground impedance size and PIF in these measurement results, so we will have to carry out the measurement more deeply and more practically with various conditions in environmental viewpoint and/or experimental viewpoint to establish the definition between ground impedance size and PIF.

  • PDF

Measurement of Transfer Impedance on Shielded Multiconductor Telecommunication Cables using IEC 96-1 Line Injection Method (IEC 96-1 Line Injection Method를 이용한 다 도체 통신케이블 차폐층의 전달임피던스 측정)

  • 이현영;오호석;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.377-383
    • /
    • 2003
  • As the high-speed data communications such as xDSL using the existing copper cable come into wide use, the electromagnetic coupling characteristics of telecommunication cables become more significant. In order to describe the screening performance of telecommunication cable, the transfer impedance of cable shield is required. This paper describes the transfer impedance for two types of telecommunication cables using the line injection method of IEC 96-1. Results are analyzed to show how the materials of cable shields, the positioning of the injection line and of the inner conductor of the CUT(Cable Under Test) affect the value of transfer impedance. We then propose the transfer impedance model of telecommunication cable based on the measurements.

Analysis on the Effects of the Induced Noise with Change of the Separation Distance between Grounding Equipment at End of Telecommunication Line and the Inducting Facilities in Power Inducting Situation (전력 유도 장애 시 통신 선로 케이블의 접지체와 유도원간의 이격거리에 의한 유도 잡음 영향 분석)

  • Choi, Mun-Hwan;Lee, Sang-Mu;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.215-218
    • /
    • 2007
  • In this paper, we have analyzed the effects from the change of separation distance between grounding equipment at end of telecommunication line and the inducting facilities in power inducting situation. In the result of measurement, we can see that as the separation distance between grounding equipment ant end of telecommunication line and the inducting facility become longer, the induced noise level and PIF level is decreased. From the another experiment results about the effect of changing the impedance size in both ends of telecommunication line, however, we already knew that as the ground impedance at either end of the telecommunication line become grower, the noise level is increased, and as the ground impedance at either end of the telecommunication line become smaller, the noise level is decreased. Hence we can not define the relationship exactly between separation distance from inducting facility to inducted facility and the induced noise level because when the grounding equipment is moved, its impedance size is changed too. In conclusion, changing the separation distance between grounding equipment at end of telecommunication line and the inducting facilities have not influence on the induced noise level.

  • PDF

Impedance measurement and analysis of overhead medium voltage power lines for broad band power line communication (BPLC) ($1{\sim}30MHz$ 광대역 전력선 통신을 위한 고압 배전선의 임피던스 특성 측정 및 해석)

  • Park, Young-Jin;Lee, Jae-Jo;Kim, Kwan-Ho;Lee, Won-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2345-2347
    • /
    • 2005
  • In this paper, impedance characteristics of overhead medium-voltage (MV) power lines is reported for power line communication (PLC) over an MV power line network. For analysis, a two-port equivalent network model of MV power lines is derived. By applying the transmission line theory, reflection behavior and impedance of power lines are investigated. For verification, impedance of power lines is measured at a test field for an MV PLC. The results show that impedance of MV power lines is between $200{\Omega}$ and $300{\Omega}$ and converges to a half of their characteristic impedance.

  • PDF

A Slotted Triangular-Patch Type Artificial Transmission Line (슬롯을 가진 삼각패치형 인공전송선로)

  • Oh, Song-Yi;Choi, Kyung;Hwang, Hee-Yong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.9 no.4
    • /
    • pp.164-167
    • /
    • 2010
  • In this paper, an artificial transmission line of triangular-patch type with slots is proposed. This artificial transmission line is useful for miniaturizing the electrical lengths of conventional transmission lines. Also, this structure is easy to regulate the characteristic impedance and electrical lengths. The electrical lengths and the characteristic impedances of the proposed artificial transmission line with some parameters are researched and summarized The proposed artificial transmission line could be useful for compact designs for most of the passive microwave components. The optional-artificial transmission line is fabricated and measured at 2.45GHz.

  • PDF

A Study on the Degree of Line Balance to Noise and its Measurement Circuits (잡음평형도와 측정회로에 관한 연구)

  • Yeo, Sang-Kun;Kim, Chong-Tae
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.9 no.2
    • /
    • pp.35-41
    • /
    • 2010
  • The balance coefficients between telecommunication lines are specified in the technical standard and the power induction computation method varies in the order of 100 times in magnitude according to the amount of impedance. The results of actual balance measurements, differing from time to time with the measurement circuit or increasing proportionally as the induction voltage increases, appeared as a measurement error because of not using the standard measurement circuit. This article investigates such errors and proposes the use of a standard balance measurement circuit and a measurement device impedance under the domestic notification standard and the ITU-T international standard.

  • PDF

A Simple Model for a DGS Microstrip Line with Stepped Impedance Slot-Lines

  • Woo, Duk-Jae;Lee, Taek-Kyung;Nam, Sangwook
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.1
    • /
    • pp.26-30
    • /
    • 2015
  • In this paper, a simple equivalent circuit model for a defected ground structure (DGS) microstrip line with stepped impedance slot-lines in the ground plane is presented. In addition, an analytic expression for the resonance frequency of the proposed structure is derived. In equivalent circuit modeling, the capacitance and the inductance of the resonance circuit are evaluated from the dimensions of the etched pattern in the ground plane. The resonance frequencies calculated from the proposed method are compared with those obtained with an electromagnetic (EM) simulation.

Input Impedance Characteristic of Medium Voltage Power Line for High Speed Power Line Communications (고속 전력선 통신을 위한 고압 배전선로 입력 임피던스 특성 연구)

  • Lee, Jae-Jo;Lee, Won-Tae;Byun, Woo-Bong;Choi, Sung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2031-2032
    • /
    • 2006
  • 고압 배전선로를 전력선통신망으로 활용하기 위하여는 고압 배전선로에 대한 입력 임피던스에 대한 정확한 이론적 고찰과 실선로에서의 측정을 통한 검증이 요구된다. 본 논문에서는 고압 배전선로용 신호결합장치의 등가회로를 바탕으로 고압 전력선통신시스템의 입출력 모뎀을 제안한다. 제안된 시스템입출력 모델을 바탕으로 고압 배전선로의 고주파(2-30MHz) 대역의 입력 임피던스를 계산한다. 고압 배전선로 통신 입출력 모델에서 지면의 유전상수, 전력선의 길이, 지면의 도전율에 따른 배전선로 입력 임피던스의 이론적 분석과 실 선로에서의 입력 임피던스 측정 결과를 소개한다.

  • PDF

Development of the grounding monitoring system for intelligent buildings (정보화 건측물을 위한 접지감시시스템 개발)

  • Cha, Sung-Chul;Lee, Tae-Hyung;Earn, Ju-Hang
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.196-197
    • /
    • 2006
  • An effective method is described for monitoring the ground impedance of intelligent building and power system. Most of grounding system of buildings are interconnected to extensive grounding network of power line, signal and control line, telecommunication line, and etc. Therefore, the residual voltages of power frequency and its harmonics may have an significant influence on the accurate measurement of ground impedance. For eliminating the influence of residual voltage, we developed a test power source for generating the 110[Hz] square wave and used digital filtering method in this research.

  • PDF

Compact UWB Bandpass Filter as Cascaded Center-Tapped CRLH Transmission-Line ZORs for Improved Stopband

  • Lee, Boram;Kahng, Sungtek;Wu, Qun
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.371-375
    • /
    • 2013
  • The design of a new compact UWB bandpass filter is proposed, which has cascaded center-tapped microstrip composite right/left-handed transmission-line zeroth-order resonators (CRLH-TL ZORs). In an attempt to reduce the size, instead of the conventional half-wavelength resonators or periodic and multiple CRLH-TL cells, only one cell ZOR geometry is adopted as each resonator in the filter. Additionally, two center-tapped ZORs are coupled to increase the slope of the skirt. Besides, stepped impedance matching parts are placed in the paths to the input and output ports to enhance passband and stopband performances. The proposed filter is shown to have the overall size of $0.69{\lambda}_g{\times}0.70{\lambda}_g$, the insertion loss much less than 1 dB, and an acceptable return loss performance in the predicted and measured results.