• 제목/요약/키워드: impact-load

검색결과 1,587건 처리시간 0.03초

Biomechanical Analysis of Muscle Fatigue and Ground Reaction Force for the Development of Outdoor Walking Shoes

  • Jang, Young-Min;Lee, Joong-Sook;Yang, Jeong-Ok;Lee, Bom-Jin
    • 한국운동역학회지
    • /
    • 제26권4호
    • /
    • pp.413-420
    • /
    • 2016
  • Objective: The purpose of this study was to analyze and compare different kinds of outdoor walking shoes in terms of muscle fatigue and ground reaction force on walking, and to provide foundational data for developing and choosing outdoor walking shoes that fit the users. Method: The study subjects were 30 healthy men. The experiment was conducted by using outdoor walking shoes with different inner and outer harnesses of the midsole, and shapes of the outsole. For data collection, electromyography was used to measure the muscle fatigue of the anterior tibial muscle and gastrocnemii, which contribute to the dorsiflexion and plantarflexion of the ankle joint, and the biceps muscle of the thigh and lateral great muscles, which contribute to the flexion and extension of the knee joint. A GRF measurement device was used to measure the X, Y, and Z axes. Results: In the type A outdoor walking shoes, regarding the hardness of the midsole, the inner part was soft, while the outer part was hard. The vertical ground reaction force was the lowest, which means least impact while walking and light load to the knees and ankles. The type C outdoor walking shoes were intended to provide a good feel in wearing the shoes. The tibialis anterior, biceps femoris, and gastrocnemii indicate low fatigue, which means that during a long-distance walk, it will minimize the fatigue in the muscles of the lower limbs. Conclusion: To sum up the study results, the different types of outdoor walking shoes indicate their unique characteristics in the biomechanical comparison and analysis. However, the difference was not statistically significant. Thus, a systematic and constant follow-up research should be conducted to cope with expanding market for outdoor walking shoes. Lastly, this study is expected to present foundational data and directions for developing outdoor walking shoes.

통행차량 특성을 반영한 강교량 피로설계트럭의 피로파괴 신뢰도해석 (Reliability Analysis of Fatigue Truck Model Using Measured Truck Traffic Statistics)

  • 신동구;권태형;박영석
    • 한국강구조학회 논문집
    • /
    • 제19권2호
    • /
    • pp.211-221
    • /
    • 2007
  • 교량의 피로파괴에 대한 Miner의 피로손상법칙을 적용하여 여러 확률변수로 표현된 피로파괴 한계상태함수에 대한 신뢰도해석을 국내에서 측정된 통행차량의 통계적 특성을 반영하여 수행하였다. 신뢰도지수의 산정에 필요한 확률변수 가운데 등가모멘트, 충격계수비, 등가하중비는 국내의 최근 측정자료를 분석하여 통계치를 산정하였으며, 피로강도, 활하중 횡분배비, 연행하중비는 국외에서 측정된 문헌자료의 통계치를 적용하였다. 신뢰도해석을 통하여 피로설계트럭의 종류, 교량수명, ADTT, 피로상세, 등가하중비, 피로설계트럭의 총중량 등의 피로손상에 관련된 여러 파라미터가 신뢰도지수에 미치는 영향을 분석하였다. 본 논문의 피로파괴에 대한 신뢰도해석 결과는 국내 LRFD 설계기준의 피로설계트럭모형과 피로한계상태의 하중계수를 결정할 때 기초 자료로 이용할 수 있을 것으로 판단된다.

FIRES IN REAL SCENARIOS

  • Ghosh, B-K
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.439-449
    • /
    • 1997
  • Studies have been carried out to determine the effect of sprinklers on fires typical of a number of occupancies including simulated of office furniture, supermarkets, carpet displays, libraries, video stores and liquor stores. After surveys of actual fire loads, the experiments were conducted in a specially designed sprinklered fire-calorimeter with a collecting hood 6 m x6 m leading to a vertical duct 1 m in diameter. Details of the rig are given elsewhere [1]. Only well ventilated fires were studied. Rate of heat release and production of various toxic chemicals were monitored during the tests. Both sprinklered and unsprinklered fires were used. The results were used to establish the unsprinklered burning behaviour and the fire-control effects of sprinklers. Before sprinkler operation, the rate of fire growth could be modelled as 12_fires as given in NFPA 92B (1991 Edition) [2]. It was found that operation of sprirnklers controlled but did not extinguish the fires. This was expected as parts of the fire load were shielded from the spray. Also there were significant increases in the concentration of carbon monoxide when the sprinklers operated. Sprinklers had little effect on the concentrations of other toxic products measured. The results from the tests were extrapolated to large single storey buildings for the same occupancy classes and the results used to compare the required and the available escape times for different occupancies, particularly whether the use of sprinklers would improve the chances of escape from those premises. It was found that in most of the cases studied, adequate escape times will be available without any special measures. For very rapid fire growths, however, special measures, such as availability of trained staff may be needed. Standard response sprinklers will have little impact.

  • PDF

Type III 고압수소저장용기의 설계 안전성 연구 (A Study on the Design Safety of Type III High-Pressure Hydrogen Storage Vessel)

  • 박우림;전상구;김송미;권오헌
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.7-14
    • /
    • 2019
  • The type III vessel, which is used to store high-pressure hydrogen gas, is made by wrapping the vessel's liner with carbon fiber composite materials for strength performance and lightening. The liner seals the internal gas and the composite resists the internal pressure. The properties of the fiber composite material depends on the angle and thickness of the fiber. Thus, engineers should consider these various design variables. However, it significantly increases the design cost due to the trial and error under designing based on experience or experiments. And, for aluminum liners, fatigue loads due to using and charging could give a huge impact on the performance of the structure. However, fatigue failure does not necessarily occur in the position under the highest load in use. Therefore, for hydrogen storage vessel, fatigue evaluation according to design patterns is essential because stress distribution varies depend on composite layer patterns. This study performed an optimization analysis and evaluated a high-pressure hydrogen storage vessel to minimize these trial and error and improve the reliability of the structure, while simultaneously conducting fatigue assessment of all patterns derived from the optimization analysis process. The results of this study are thought to be useful in the strength improvement and life design of composite reinforced high-pressure storage vessels.

우수유출량 및 오염부하량을 고려한 LID 최적위치 결정 (Determination of Optimal LID Location Considering Runoff and Pollutant Load)

  • 전상훈;이의훈;권순호;조덕준;김중훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.480-480
    • /
    • 2017
  • 급격한 도시화 및 산업화는 주차장, 건물 및 도로 등 유역의 불투수 면적을 증가시켜 강우에 의한 침수피해 및 비점오염원에 따른 하천의 수질오염을 유발하고 있다. 최근 국내에서는 이러한 문제점을 개선하기 위해 유출저감 시설인 저영향개발 (Low Impact Development, LID)을 도입하여 연구를 진행하고 있다. LID 기술은 우수의 침투 및 저류를 통해 도시화에 따른 영향을 최소화하여 개발 이전의 토지 상태에 최대한 가깝게 만들기 위한 도시개발 기법이다. 대표적인 LID 요소기술로는 옥상녹화, 투수성포장 및 생태저류장치 등이 있으며 도로변, 건물주변, 건물옥상 등에 설치되어 강우유출량과 비점오염물질의 오염부하량을 저감시키는 역할을 한다. 본 연구에서는 안양천에 위치한 가산 1 빗물펌프장 유역에 LID 기법을 적용하였으며, LID 요소기술은 옥상녹화 및 투수성포장으로 선정하였다. LID의 설치위치를 변경하여 적용시키면서 유출지점에서의 우수유출량 및 오염부하량을 산정하고 이를 최대로 저감시킬 수 있는 최적위치를 결정하였다. 최적위치에 LID를 설치하였을 때 우수유출량은 옥상녹화의 경우 약 2.20 %, 투수성포장의 경우 약 2.28 %의 저감효과를 나타내었다. 또한, 오염부하량은 두 가지 경우에서 약 4.74 %의 저감효과를 나타내었다. 최적위치를 결정하는 과정에서 우수유출량과 오염부하량의 저감효과가 서로 독립적으로 거동한다는 것을 확인할 수 있었다. 추후 연구에서는 LID 요소기술을 복합적으로 설치한 경우의 저감효과에 대한 분석이 필요할 것으로 판단된다.

  • PDF

Wind tunnel investigation of correlation and coherence of wind loading on generic tall twin buildings in close proximity

  • Lim, Juntack;Bienkiewicz, Bogusz
    • Wind and Structures
    • /
    • 제18권4호
    • /
    • pp.443-456
    • /
    • 2014
  • A popular modern architectural form for tall buildings is two (or more) towers which are structurally linked through such features as a shared podium or sky-bridges. The fundamental features of the wind loading and the structural links of such buildings can be studied by measuring load components on the individual unlinked towers along with their correlations. This paper describes application of dual high frequency force balance (DHFFB) in a wind tunnel study of the base wind loading exerted on generic tall twin buildings in close proximity. Light models of two identical generic tall buildings of square plan were mounted on DHFFB and the base wind loading exerted on the buildings was simultaneously acquired. The effects of the relative positions of the buildings on the correlations and coherences involving loading components on each building and on the two buildings were investigated. For some relative positions, the effects of the building proximity on the wind loading were significant and the loading was markedly different from that exerted on single buildings. In addition, the correlations between the loadings on the two buildings were high. These effects have potential to significantly impact, for example, the modally-coupled resonant responses of the buildings to the aerodynamic excitations. The presented results were not meant to be recommended for direct application in wind resistant design of tall twin buildings. They were intended to show that wind loading on tall buildings in close proximity is significantly different from that on single buildings and that it can be conveniently mapped using DHFFB.

시뮬레이션을 통한 지열 히트펌프 시스템과 VRF 시스템의 에너지 성능비교 (Comparison of Energy Performance between Ground-Source Heat Pump System and Variable Refrigerant Flow(VRF) Systems using Simulation)

  • 손병후;임효재;강성재
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.30-40
    • /
    • 2021
  • This paper compares the annual energy performance of four different types of air-conditioning systems in a medium-sized office building. Chiller and boiler, air-cooled VRF, ground-source VRF, and ground-source heat pump systems were selected as the systems to be compared. Specifically, the energy performance of the GSHP system and the ground-source VRF system were compared with each other and also with conventional HVAC systems including the chiller and boiler system and air-cooled VRF system. In order to evaluate and compare the energy performances of four systems for the office building, EnergyPlus, a whole-building energy simulation program, was used. The EnergyPlus simulation results show that both the GSHP and the ground-source VRF systems not only save more energy than the other two systems but also significantly reduce the electric peak demand. These make the GSHP and the VRF systems more desirable energy-efficient HVAC technologies for the utility companies and their clients. It is necessary to analyze the impact of partial load performance of ground-source heat pump and ground-source VRF on the long-term (more than 20 years) performance of ground heat exchangers and entire systems.

Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw

  • Arbash, Mahmood Ali;Parambathkandi, Ashik Mohsin;Baco, Abdul Moeen;Alhammoud, Abduljabbar
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1053-1059
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To detect the effect of cannulated (poly-axial head) and solid (mono-axial head) screws on the local kyphotic angle, vertebral body height, and superior and inferior angles between the screw and the rod in the surgical management of thoracolumbar fractures. Overview of Literature: Biomechanics studies showed that the ultimate load, yield strength, and cycles to failure were significantly lower with cannulated (poly-axial head) pedicle comparing to solid core (mono-axial head). Methods: The medical charts of patients with thoracolumbar fractures who underwent pedicle screw fixation with cannulated or solid pedicle screws were retrospectively reviewed; the subjects were followed up from January 2011 to December 2015. Results: Total 178 patients (average age, $36.1{\pm}12.4years$; men, 142 [84.3%]; women, 28 [15.7%]) with thoracolumbar fractures who underwent surgery and were followed up at Hamad Medical Corporation were classified, based on the screw type as those with cannulated screws and those with solid screws. The most commonly affected level was L1, followed by L2 and D12. Surgical correction of the local kyphotic angle was significantly different in the groups; however, there was no significant difference in the loss of correction of the local kyphotic angle of the groups. Surgical correction of the reduction in the vertebral body height showed statistical significance, while the average loss of correction in the reduction of the vertebral body height was not significantly different. The measurement of the angles made by the screws on the rods was not significantly different between the cannulated (poly-axial head) and solid (mono-axial head) screw groups. Conclusions: Solid screws were superior in terms of providing increased correction of the kyphotic angle and height of the fractured vertebra than the cannulated screws; however, no difference was noted between the screws in the maintenance of the superior and inferior angles of the screw with the rod.

A Case Study of Decreasing Environment Pollution Caused by Energy Consumption of a Dormitory Building Which Only Using Electricity by Efficiently Simulating Applying Residential SOFC (Solid Oxide Fuel Cell)

  • Chang, Han;Lee, In-Hee
    • Architectural research
    • /
    • 제21권1호
    • /
    • pp.21-29
    • /
    • 2019
  • Recent years in Korea, some new developed buildings are only using electricity as power for heating, cooling, bathing and even cooking which means except electricity, there is no natural gas or other kinds of energy used in such kind of building. In vehicle industry area, scientists already invented electric vehicle as an environment friendly vehicle; after that, in architecture design and construction field, buildings only using electricity appeared; the curiosity of the environment impact of energy consumption by such kind of building lead me to do this research. In general, electricity is known as a clean energy resource reasoned by it is noncombustible energy resource; however, although there is no environmental pollution by using electricity, electricity generation procedure in power plant may cause huge amount of environment pollution; especially, electricity generation from combusting coal in power plant could emit enormous air pollutants to the air. In this research, the yearly amount of air pollution by energy using under traditional way in research target building that is using natural gas for heating, bathing and cooking and electricity for lighting, equipment and cooling is compared with yearly amount of air pollution by only using electricity as power in the building; result shows that building that only uses electricity emits much more air pollutants than uses electricity and natural gas together in the building. According to the amount of air pollutants comparison result between two different energy application types in the building, residential SOFC (Solid oxide fuel cell) is simulated to apply in this building for decreasing environment pollution of the building; furthermore, high load factor could lead high efficiency of SOFC, in the scenario of simulating applying SOFC in the building, SOFC is shared by two or three households in spring and autumn to increase efficiency of the SOFC. In sum, this research is trying to demonstrate electricity is a conditioned environment friendly energy resource; in the meanwhile, SOFC is simulated efficiently applying in the building only using electricity as power to decrease the large amount of air pollutants by energy using in the building. Energy consumption of the building is analyzed by calibrated commercial software Design Builder; the calibrated mathematical model of SOFC is referred from other researcher's study.

교량 케이블시스템의 모드변수에 관한 연구 (A Study on the Modal Parameters for Cable System of Bridge)

  • 이현철;조영훈;김진수;박경호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권5호
    • /
    • pp.48-59
    • /
    • 2019
  • 최근 들어 장대교량의 건설에 현수교, 사장교 등과 같은 케이블이 주 요소인 교량 형식이 급증하고 있다. 이와 같은 구조물에서 케이블이 미치는 영향은 매우 크며, 구조해석을 위해서 케이블에 대한 연구 및 케이블의 모드 특성에 따른 구조계의 변화를 연구해 볼 필요가 있다. 특히, 케이블은 거더에 가해지는 하중효과를 주탑으로 전달하는 캠버조절과 직결되고 전체 구조에서 중요한 부재로서, 가설시 가해지는 초기 장력과 시간이 경과후 장력을 비교하므로서 교량의 노후상태와 이상유무를 파악하는 데 기여하고자 본 연구를 수행하였다. 따라서 본 연구에서는 충격해머를 통한 모드 해석으로부터 케이블의 질량과 케이블의 길이변화에 따른 모드의 특성을 파악할 수 있었고, 공용중에 있는 케이블에서는 위상각의 변화가 비례관계임을 확인하였다. 또한 저차모드에서 지배모드가 결정되는 특성을 MAC분석을 통하여 알 수 있었다.