• Title/Summary/Keyword: impact imaging

Search Result 265, Processing Time 0.023 seconds

Risk Factors for Prevertebral Soft Tissue Swelling Following Single-level Anterior Cervical Spine Surgery

  • Junsang Park;Sang Mook Kang;Yu Deok Won;Myung-Hoon Han;Jin Hwan Cheong;Byeong-Jin Ha;Je Il Ryu
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.6
    • /
    • pp.716-725
    • /
    • 2023
  • Objective : Anterior cervical spine surgery (ACSS) is a common surgical procedure used to treat cervical spinal degenerative diseases. One of the complications associated with ACSS is prevertebral soft tissue swelling (PSTS), which can result in airway obstruction, dysphagia, and other adverse outcomes. This study aims to investigate the correlation between various cervical sagittal parameters and PSTS following single-level ACSS, as well as to identify independent risk factors for PSTS. Methods : A retrospective study conducted at a single institution. The study population included all patients who underwent single-level ACSS between January 2014 and December 2022. Patients with a history of cervical spine surgery or trauma were excluded from the study. The presence and severity of PSTS was assessed by reviewing pre- and postoperative imaging studies. The potential risk factors for PSTS that were examined include patient age, sex, body mass index, tobacco use, comorbidities, serum albumin levels, operative time, implant type, implanted level, and various cervical spine sagittal parameters. Multivariate linear regression analysis was performed to identify the independent risk factors for PSTS. Results : A total of 62 consecutive patients who underwent single-level ACSS over a 8-year period at a single institution were enrolled in this study. Only preoperative segmental angle showed positive correlation with PSTS among various cervical spine sagittal parameters (r=0.36, p=0.005). Artificial disc replacement showed a negative correlation with PSTS (β=-0.38, p=0.002), whereas the use of demineralized bone matrix (DBM) had a positive impact on PSTS (β=0.33, p=0.009). We found that male sex, lower preoperative serum albumin, and implantation of upper cervical level (above C5) were independent predictors for PSTS after single-level ACSS (β=1.21; 95% confidence interval [CI], 0.27 to 2.15; p=0.012; β=-1.63; 95% CI, -2.91 to -0.34; p=0.014; β=1.44; 95% CI, 0.38 to 2.49; p=0.008, respectively). Conclusion : Our study identified male sex, lower preoperative serum albumin levels, and upper cervical level involvement as independent risk factors for PSTS after single-level ACSS. These findings can help clinicians monitor high-risk patients and take preventive measures to reduce complications. Further research with larger sample sizes and prospective designs is needed to validate these findings.

Study of Confidence Ranges for Field Phase Difference Measurement Data Collected using Geophones (지오폰을 활용한 현장 위상각차 계측 데이터 신뢰 구간에 관한 기초 연구)

  • Kim, Gunwoong
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.3
    • /
    • pp.41-54
    • /
    • 2024
  • Regular monitoring plays a crucial role in ensuring the safety of geotechnical structures. Currently, nondestructive methods are employed to monitor such structures to minimize the impact, e.g., sensor-based accelerometers, displacement meters, image-based lasers, and drone imaging. These technologies can observe surface changes; however, they frequently suffer difficulties in terms of identifying changes in internal properties. To monitor changes in internal properties, in situ geotechnical investigations can be employed. A nondestructive test that can be used for this purpose is the spectral analysis of surface wave (SASW) test using geophones. The SASW test is a nondestructive method; however, due to the time required for data interpretation and the difficulty in analyzing the data, it is challenging to use the SASW test for monitoring applications that require frequent observations. However, it is possible to apply the first-step analysis, which yields the dispersion curve, for monitoring rather than the complete SASW analysis, which yields the shear wave velocity. Thus, this paper presents a fundamental study on the phase difference that derives the dispersion curve to utilize the SASW test for monitoring. The reliability of each phase difference interval is examined to determine the boundary to the subjected monitor. The study used phase difference data obtained using a geophone from a single-layered, homogeneous ground site to evaluate reliable boundaries. The findings of this study are expected to improve the utility of monitoring by identifying the ideal boundary for phase difference data.

Role of Dedicated Subspecialized Radiologists in Multidisciplinary Team Discussions on Lower Gastrointestinal Tract Cancers

  • Sun Kyung Jeon;Se Hyung Kim;Cheong-il Shin;Jeongin Yoo;Kyu Joo Park;Seung-Bum Ryoo;Ji Won Park;Tae-You Kim;Sae-Won Han;Dae-Won Lee;Eui Kyu Chie;Hyun-Cheol Kang
    • Korean Journal of Radiology
    • /
    • v.23 no.7
    • /
    • pp.732-741
    • /
    • 2022
  • Objective: To determine the impact of dedicated subspecialized radiologists in multidisciplinary team (MDT) discussions on the management of lower gastrointestinal (GI) tract malignancies. Materials and Methods: We retrospectively analyzed the data of 244 patients (mean age ± standard deviation, 61.7 ± 11.9 years) referred to MDT discussions 249 times (i.e., 249 cases, as five patients were discussed twice for different issues) for lower GI tract malignancy including colorectal cancer, small bowel cancer, GI stromal tumor, and GI neuroendocrine tumor between April 2018 and June 2021 in a prospective database. Before the MDT discussions, dedicated GI radiologists reviewed all imaging studies again besides routine clinical reading. The referring clinician's initial diagnosis, initial treatment plan, change in radiologic interpretation compared with the initial radiology report, and the MDT's consensus recommendations for treatment were collected and compared. Factors associated with changes in treatment plans and the implementation of MDT decisions were analyzed. Results: Of the 249 cases, radiologic interpretation was changed in 73 cases (29.3%) after a review by dedicated GI radiologists, with 78.1% (57/73) resulting in changes in the treatment plan. The treatment plan was changed in 92 cases (36.9%), and the rate of change in the treatment plan was significantly higher in cases with changes in radiologic interpretation than in those without (78.1% [57/73] vs. 19.9% [35/176], p < 0.001). Follow-up records of patients showed that 91.2% (227/249) of MDT recommendations for treatment were implemented. Multiple logistic regression analysis revealed that the nonsurgical approach (vs. surgical approach) decided through MDT discussion was a significant factor for patients being managed differently than the MDT recommendations (odds ratio, 4.48; p = 0.017). Conclusion: MDT discussion involving additional review of radiology examinations by dedicated GI radiologists resulted in a change in the treatment plan in 36.9% of cases. Changes in treatment plans were significantly associated with changes in radiologic interpretation.

Impact of Collateral Circulation on Futile Endovascular Thrombectomy in Acute Anterior Circulation Ischemic Stroke

  • Yoo Sung Jeon;Hyun Jeong Kim;Hong Gee Roh;Taek-Jun Lee;Jeong Jin Park;Sang Bong Lee;Hyung Jin Lee;Jin Tae Kwak;Ji Sung Lee;Hee Jong Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.1
    • /
    • pp.31-41
    • /
    • 2024
  • Objective : Collateral circulation is associated with the differential treatment effect of endovascular thrombectomy (EVT) in acute ischemic stroke. We aimed to verify the ability of the collateral map to predict futile EVT in patients with acute anterior circulation ischemic stroke. Methods : This secondary analysis of a prospective observational study included data from participants underwent EVT for acute ischemic stroke due to occlusion of the internal carotid artery and/or the middle cerebral artery within 8 hours of symptom onset. Multiple logistic regression analyses were conducted to identify independent predictors of futile recanalization (modified Rankin scale score at 90 days of 4-6 despite of successful reperfusion). Results : In a total of 214 participants, older age (odds ratio [OR], 2.40; 95% confidence interval [CI], 1.56 to 3.67; p<0.001), higher baseline National Institutes of Health Stroke Scale (NIHSS) scores (OR, 1.12; 95% CI, 1.04 to 1.21; p=0.004), very poor collateral perfusion grade (OR, 35.09; 95% CI, 3.50 to 351.33; p=0.002), longer door-to-puncture time (OR, 1.08; 95% CI, 1.02 to 1.14; p=0.009), and failed reperfusion (OR, 3.73; 95% CI, 1.30 to 10.76; p=0.015) were associated with unfavorable functional outcomes. In 184 participants who achieved successful reperfusion, older age (OR, 2.30; 95% CI, 1.44 to 3.67; p<0.001), higher baseline NIHSS scores (OR, 1.12; 95% CI, 1.03 to 1.22; p=0.006), very poor collateral perfusion grade (OR, 4.96; 95% CI, 1.42 to 17.37; p=0.012), and longer door-to-reperfusion time (OR, 1.09; 95% CI, 1.03 to 1.15; p=0.003) were associated with unfavorable functional outcomes. Conclusion : The assessment of collateral perfusion status using the collateral map can predict futile EVT, which may help select ineligible patients for EVT, thereby potentially reducing the rate of futile EVT.

A Study on Monitoring Surface Displacement Using SAR Data from Satellite to Aid Underground Construction in Urban Areas (위성 SAR 자료를 활용한 도심지 지하 교통 인프라 건설에 따른 지표 변위 모니터링 적용성 연구)

  • Woo-Seok Kim;Sung-Pil Hwang;Wan-Kyu Yoo;Norikazu Shimizu;Chang-Yong Kim
    • The Journal of Engineering Geology
    • /
    • v.34 no.1
    • /
    • pp.39-49
    • /
    • 2024
  • The construction of underground infrastructure is garnering growing increasing research attention owing to population concentration and infrastructure overcrowding in urban areas. An important associated task is establishing a monitoring system to evaluate stability during infrastructure construction and operation, which relies on developing techniques for ground investigation that can evaluate ground stability, verify design validity, predict risk, facilitate safe operation management, and reduce construction costs. The method proposed here uses satellite imaging in a cost-effective and accurate ground investigation technique that can be applied over a wide area during the construction and operation of infrastructure. In this study, analysis was performed using Synthetic Aperture Radar (SAR) data with the time-series radar interferometric technique to observe surface displacement during the construction of urban underground roads. As a result, it was confirmed that continuous surface displacement was occurring at some locations. In the future, comparing and analyzing on-site measurement data with the points of interest would aid in confirming whether displacement occurs due to tunnel excavation and assist in estimating the extent of excavation impact zones.

Effects of Environmental Conditions on Vegetation Indices from Multispectral Images: A Review

  • Md Asrakul Haque;Md Nasim Reza;Mohammod Ali;Md Rejaul Karim;Shahriar Ahmed;Kyung-Do Lee;Young Ho Khang;Sun-Ok Chung
    • Korean Journal of Remote Sensing
    • /
    • v.40 no.4
    • /
    • pp.319-341
    • /
    • 2024
  • The utilization of multispectral imaging systems (MIS) in remote sensing has become crucial for large-scale agricultural operations, particularly for diagnosing plant health, monitoring crop growth, and estimating plant phenotypic traits through vegetation indices (VIs). However, environmental factors can significantly affect the accuracy of multispectral reflectance data, leading to potential errors in VIs and crop status assessments. This paper reviewed the complex interactions between environmental conditions and multispectral sensors emphasizing the importance of accounting for these factors to enhance the reliability of reflectance data in agricultural applications.An overview of the fundamentals of multispectral sensors and the operational principles behind vegetation index (VI) computation was reviewed. The review highlights the impact of environmental conditions, particularly solar zenith angle (SZA), on reflectance data quality. Higher SZA values increase cloud optical thickness and droplet concentration by 40-70%, affecting reflectance in the red (-0.01 to 0.02) and near-infrared (NIR) bands (-0.03 to 0.06), crucial for VI accuracy. An SZA of 45° is optimal for data collection, while atmospheric conditions, such as water vapor and aerosols, greatly influence reflectance data, affecting forest biomass estimates and agricultural assessments. During the COVID-19 lockdown,reduced atmospheric interference improved the accuracy of satellite image reflectance consistency. The NIR/Red edge ratio and water index emerged as the most stable indices, providing consistent measurements across different lighting conditions. Additionally, a simulated environment demonstrated that MIS surface reflectance can vary 10-20% with changes in aerosol optical thickness, 15-30% with water vapor levels, and up to 25% in NIR reflectance due to high wind speeds. Seasonal factors like temperature and humidity can cause up to a 15% change, highlighting the complexity of environmental impacts on remote sensing data. This review indicated the importance of precisely managing environmental factors to maintain the integrity of VIs calculations. Explaining the relationship between environmental variables and multispectral sensors offers valuable insights for optimizing the accuracy and reliability of remote sensing data in various agricultural applications.

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.

Classification of submitted KSNMT dissertation (대한핵의학기술학회 투고 논문 분류)

  • Han, Dong-Chan;Lee, Hyuk;Hong, Gun-Chul;Ahn, Byeong-Ho;Choi, Seong-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.65-69
    • /
    • 2017
  • Purpose KSNMT(Korea Society of Nuclear Medicine Technology) stepping first step in 1997, has published first journal related with nuclear medicine technology in 1985. With classifying In Vivo Session Dissertation reported in the entire journal, trend of the Dissertation will be studied. Materials and Methods Dissertations which published from 1985 to first half of 2016 in the journal are classified with presentation form and with scanner, And all the data is organized with Excel program. Through the data, the number of dissertations published in each year, the number of dissertation published in details, and keyword distributions in each period are analyzed. Results The number of In-vivo section dissertations was 1151 and the number of In-vivo section dissertations that have common subject with In-vitro section was 28. The number of In-vivo section dissertation in 1980s was 46, in 1990s was 149, in 2000 was 467 and from 2010 to the first half of 2016 was 517. The number of dissertation with original articles was 571, with abstract was 529, with symposium was 31, with special lecture was 25, with review was 11, with interesting image was 7, with poster was 3 and with case report was 2. With symposium and special lecture excluded, which count 56, the number of dissertation with PET was 319, with Planar was 302, with SPECT was 172, with radiopharmaceutical was 113, with guard and safety management 103, with BMD was 28, etc. was 86. The number of dissertation about oncology was 201, about scanner was 179, about cardiovascular and circulatory system was 102, about safe environment was 82, about musculoskeletal system was 76, about nervous nuclear medicine was 66, about quality assurance was 61, about genitourinary system was 56, about endocrine system was 49, about digestive system was 44, about Therapy, about industrial safety was 24, about molecular imaging was 15, infection and inflammation was 9, about respiratory system was 8 and etc. was 108. The mostly used keyword through 1999 to 2005 was PET and through 2006 to 2016 was PET/CT. Conclusion To encourage various dissertations to be submitted, Korea Society of Nuclear Medicine should analyze date about not only about dissertations that are already published, but also about various research materials. Moreover, Korea Society of Nuclear Medicine also have to provide technical support such as sharing big data from homepage and systematical support to its member to publish dissertation that has high impact factor. It is important each individual researcher to have continuing effort as well as each organization cooperation.

  • PDF

The Usability Evaluation According to the Application of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Nam-Kung, Sik;Kim, Ji Hyeon;Lee, Ju young;Park, Hoon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.36-42
    • /
    • 2013
  • Purpose: Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we want to identify the quality of the image and the impact on the SUV. Materials and Methods: In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mmPb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. Results: When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Conclusion: Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose be considered. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference is more decreased as gab of shields and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep or other organs should be a priority rather than superficial disease. Through this study, when applying identified to clinical examination, the reduction of unnecessary exposure is considered.

  • PDF

Different $^{18}$F-FDG Uptake According to Tumor location and Morphology of Cholangiocarcinoma and Its Clinical Implication (담관암의 위치와 형태에 따른 $^{18}$F-FDG 섭취량의 차이와 임상적 의의)

  • Lee, Won-Seok;Lee, Yoon-Jae;Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.317-322
    • /
    • 2009
  • Purpose: $^{18}$F-flurodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of $^{18}$F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. Materials and Methods: From April 2005 to May 2008, eighty two patients (M:F = 55:27, age 66.2$\pm$9.6 yrs) with CC underwent $^{18}$F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV$_{max}$) was obtained from the primary tumor. The difference of SUV$_{max}$ according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Results: Overall sensitivity of PET scan was 81.7% in CC. SUV$_{max}$ on PET scan in intrahepatic CC was significantly higher compared to extrahepatic CC. In extrahepatic CC, polypoid type showed significantly higher SUV$_{max}$ compared to scirrhous type. Conclusion: $^{18}$F-FDG PET may have a significant impact on clinical decision-making and on the management of intrahepatic cholangiocarcinoma. And it is related to the shape of the tumor and the sensitivity of detection is higher in the mass-forming type than in the scirrhous type.