• Title/Summary/Keyword: impact imaging

Search Result 262, Processing Time 0.025 seconds

Diagnostic Accuracy of Imaging Study and the Impact of Clinical Risk Factors on the Presence of Residual Tumor Following Unplanned Excision of Soft Tissue Sarcomas (악성 연부조직 종양에 대한 무계획적 절제술 후 잔여 종양의 영상학적 진단의 정확성과 임상적 위험인자)

  • Oh, Eunsun;Seo, Sung Wook;Jeong, Jeonghwan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.150-156
    • /
    • 2019
  • Purpose: This study examined the diagnostic accuracy of an imaging study to find the factors that affect the presence of residual tumors after an unplanned excision of sarcomas. Materials and Methods: Ninety-eight patients, who underwent a re-excision after unplanned surgery between January 2008 and December 2014, were enrolled in this study. Magnetic resonance imaging (MRI) was performed before reoperation in all patients. Positron emission tomography (PET)-computed tomography was performed on 54 patients. A wide re-excision and histology diagnosis were performed in all cases. The clinical variables were evaluated using univariate logistic regression and multivariate logistic regression. Results: The presence of a deep-seated tumor increases the risk of remnant tumors (odds ratio: 3.21, p=0.02, 95% confidence interval: 1.25-8.30). The sensitivity for detecting residual tumors is high in MRI (sensitivity 0.79). Conclusion: Deep-seated tumors have a significantly higher risk of remnant tumors. Because the negative predictive value of MRI and PET scans is very low, reoperation should be performed regardless of a negative result.

KYDISC program: The Impact of Mergers on the Evolution of Galaxies

  • Oh, Sree
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.30.1-30.1
    • /
    • 2017
  • In the hope to detect low-surface brightness features (${\mu}_{r^{\prime}}{\sim}27\;mag\;arcsec^{-2}$), we carried out KASI-Yonsei Deep Imaging Survey for Clusters (KYDISC) targeting 14 local clusters at 0.016 < z < 0.145 using Magellan/IMACS telescope and CFHT/MegaCam. Out of 1450 cluster galaxies, 18% of galaxies show the signatures of galaxy mergers. We explore merger-driven changes from various point-of-view. We first examine color-magnitude relations, and find that galaxies related to recent mergers are populated more on blue color than their counterparts. Besides, we find the extremely low frequency of mergers on low-mass red-sequence galaxies, suggesting a migration of red galaxies into the green-valley region through merger-driven star-formation. We also study the mass-size relation of our sample, finding a larger galaxy size in galaxies related to recent mergers. Our results suggest that mergers can simultaneously change properties of galaxies, making outliers on galactic scaling relations.

  • PDF

Probing Tidal Field Strength of Virgo Cluster Galaxies

  • Yoon, Hye-In;Chung, Ae-Ree
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.74.2-74.2
    • /
    • 2011
  • We probe the tidal perturbation parameter f of Virgo cluster galaxies. The goal is to measure the strength of tidal fields around individual galaxies to get better understanding gravitational processes that can affect galaxy evolution in the cluster environment. The f-value is defined as a logarithmic ratio between the net internal gravitational force within a galaxy and the external tidal force exerted by a neighboring galaxy. Hence, it provides one way to quantify the tidal field strength of galaxies, in particular, due to galaxy neighbors. In this study, we determine f-values of the VIVA galaxies, samples of the VLA Imaging study of Virgo galaxies in Atomic gas, using the Extended Virgo Cluster Catalog (EVCC) which is the most complete Virgo cluster catalog to date. With diagnostics based on the HI gas and R-band morphologies, we discuss the impact of the tidal fields on the evolution of the VIVA sample. Also, we compare the tidal field strength to the intra cluster medium (ICM) pressure for each sample galaxy to pin down environmental processes at work.

  • PDF

Operation of Night Vision Goggle for Aircraft (항공기 야간투시경 운용)

  • Kwon, Jong-Kwang;Kim, Whan-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.34-41
    • /
    • 2006
  • This paper describes the general considerations and operational applications of aircraft night vision goggle(NVG). The operators should recognize the NVG characteristics, natural night light sources and interoperability between them. And they have to keep attention to the method to take steps to avoid misperceptions, illusions during flight, and the negative impact on the effectiveness and safety of the mission. The considerations based on the interoperability between NVG and night operation suggest the evaluation items of NVG field test and flight test.

Analysis and 3D Reconstruction of a Cerebral Vascular Network Using Image Threshold Techniques in High-resolution Images of the Mouse Brain (쥐 뇌의 고해상도 이미지에서 임계화 기법을 활용한 뇌혈관 네트워크 분석 및 3D 재현)

  • Lee, Junseok
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.9
    • /
    • pp.992-999
    • /
    • 2019
  • In this paper, I lay the foundation for creating a multiscale atlas that characterizes cerebrovasculature structural changes across the entire brain of a mouse in the Knife-Edge Scanning Microscopy dataset. The geometric reconstruction of the vascular filaments embedded in the volume imaging dataset provides the ability to distinguish cerebral vessels by diameter and other morphological properties across the whole mouse brain. This paper presents a means for studying local variations in the small vascular morphology that have a significant impact on the peripheral nervous system in other cerebral areas, as well as the robust and vulnerable side of the cerebrovasculature system across the large blood vessels. I expect that this foundation will prove invaluable towards data-driven, quantitative investigations into the system-level architectural layout of the cerebrovasculature and surrounding cerebral microstructures.

HI gas properties of BAT-BASS AGN host galaxies

  • Kim, Jeein;Chung, Aeree;Baek, Junhyun;Oh, Kyuseok;Wong, O. Ivy;Koss, Michael J.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.69.1-69.1
    • /
    • 2021
  • We present preliminary results of the VLA archival HI data of local AGN hosts. The sample consists of the galaxies selected from the Swift-BAT hard X-ray survey. The main goal is to probe the gas environment of the sample in order to verify the role of gas accretion as one of the major AGN triggering mechanisms. HI, as a mostly diffuse and extended gas component in many galaxies, is a sensitive tracer to explore the impact of the surroundings on galaxies. In this work, we therefore probe the HI imaging data of a subsample of BAT-BASS AGN hosts, starting with the cases for which relatively high HI fluxes have been reported from the past single-dish observations. Based on their resolved HI properties, we will discuss the possibility of gas accretion and its role in powering AGNs in these examples.

  • PDF

A Study on the Post Processing of Flash Boiling Spray Image from Shadowgraphy (감압비등 분무의 역광이미지 후처리 기법에 관한 연구)

  • Hyunchang Lee
    • Journal of ILASS-Korea
    • /
    • v.29 no.2
    • /
    • pp.91-97
    • /
    • 2024
  • When investigating the droplet, spray, and impact of liquid on a solid plate, backlight imaging has been widely used to understand these phenomena. However, some previous studies have suffered from poor image quality. In this study, various combinations of image processing algorithms, such as white image correction, histogram equalization, CLAHE, Otsu's binarization, and multi-Otsu's binarization, have been applied to flash boiling spray images to enhance image quality for qualitative observation and semi-quantitative spray angle evaluation. To acquire images with high contrast for qualitative observation, applying CLAHE was effective, making small droplets and detailed shapes of the jet noticeable. However, when images were averaged to determine spray angle or penetration length based on intensity, this method induced artifact unphysical patterns, thus requiring careful consideration. Based on the algorithm proposed in this study, the spray angle variation according to injection pressure and temperature has been calculated, showing a reasonable trend.

Research on Measurement of Infrared Thermograpphy under High Temperature Condition (고온 환경에서의 적외선 열화상 측정에 관한 연구)

  • Jun-Sik Lee;Jae-Wook Jeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

Multiparametric MRI of Prostate Cancer after Biopsy: Little Impact of Hemorrhage on Tumor Staging

  • Choi, Moon Hyung;Jung, Seung Eun;Park, Yong Hyun;Lee, Ji Youl;Choi, Yeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.139-147
    • /
    • 2017
  • Purpose: To evaluate differences in staging accuracy of prostate cancer according to the extent of hemorrhage on multiparametric MRI performed after biopsy. Materials and Methods: We enrolled 71 consecutive patients with biopsy-proven prostate cancer. Patients underwent MRI followed by a prostatectomy at our institution in 2014. Two radiologists reviewed the MRI to determine the tumor stage. Correlation between biopsy-MRI interval and extent of hemorrhage was evaluated. Regression analyses were used to determine factors associated with accuracy of tumor staging. Results: The mean interval between biopsy and MRI was $17.4{\pm}10.2days$ (range, 0-73 days). The interval between prostate biopsy and MRI and the extent of hemorrhage were not significantly correlated (P = 0.880). There was no significant difference in the accuracy rate of staging between the small and large hemorrhage groups. Conclusion: Biopsy-induced hemorrhage in the prostate gland is not sufficiently absorbed over time. The extent of hemorrhage and the short interval between biopsy and MRI may not impair tumor detection or staging on multiparametric MRI.