• Title/Summary/Keyword: immersion technique

Search Result 171, Processing Time 0.021 seconds

Application of Laser-based Ultrasonic Technique for Evaluation of Corrosion and Defects in Pipeline (배관부 부식 및 결함 평가를 위한 레이저 유도 초음파 적용 기술)

  • Choi, Sang-Woo;Lee, Joon-Hyun;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.95-102
    • /
    • 2005
  • There are many tube and pipeline in nuclear power plant under high temperature and high pressure. Erosion and corrosion defects were expected on these tube and pipe-line by environmental and mechanical factors. These erosion and corrosion defects ran be evaluated by ultrasonic technique. In these study, Scanning Laser Source(SLS) technique was applied to detect defect and construct image. This technique also makes detection possible on rough and curved surfaces such as tube and pipe-line by scanning. Conventional ultrasonic scanning technique requires immersion of specimen or water jet for transferring ultrasonic wave between transducer and specimen. However, this SLS technique does not need contacting and couplant to generate surface wave and to get flaw images. Therefore, this SLS technique has several advantages, for complicated production inspection, non-contact, remote from specimen, and high resolution. In this study, SLS images were obtained with various conditions of generation laser ultrasound and receiving in order to enhance detectability of flaws on the tube. Stress corrosion cracks were produced on tube and images of stress corrosion cracks were constructed by using SLS technique.

Changes of the surface roughness depending on immersion time and powder/liquid ratio of various tissue conditioners (수종의 조직 양화재의 침수시간과 분액비에 따른 표면 거칠기의 변화)

  • Kim, Kyung-Soo;Moon, Hong-Suk;Shim, June-Sung;Jung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.108-118
    • /
    • 2009
  • Statement of problem: Volume stability, microstructure reproducibility and fluidity along with compatibility with dental stone must be in consideration in order to use tissue conditioner as a material for functional impression. There are few studies concerning the influence of time factor in oral condition on surface roughness of the stone and optimal retention period in the oral cavity considering such changes in surface roughness. Purpose: The purpose of this study was to find out the influence of various kinds of tissue conditioner, its powder/liquid ratio and immersion time on surface roughness of the stone. Material and methods: Materials used in this study were the three kinds of tissue conditioners(Coe-Comfort, Visco-Gel, Soft-Liner) and were grouped into three: group R-mixed with standard powder/liquid ratio that was recommended by the manufacturers, group M-mixed with 20% more powder, group L-mixed with 20% less powder. Specimens were made with the size of 20 mm diameter and 2 mm width. Each tissue conditioner specimens were subdivided into 5 groups according to the immersion time(0 hour, 1 day, 3 days, 5 days, 7 days), completely immersed into artificial saliva and were stored under $37^{\circ}C$. Specimens of which the given immersion time elapsed were taken out and were poured with improved stone, making the stone specimens. Surface roughness of the stone specimens was measured by a profilometer. Results: Within the limitation of this study, the following results were drawn. 1. Major influencing factor on surface roughness of the stone model made from tissue conditioner was the retention period(contribution ratio($\rho$)=62.86%, P<.05) of the tissue conditioner in oral cavity to make functional impression. 2. In case of Coe-Comfort, higher mean surface roughness value of the stone model with statistical significance was observed compared to that of Soft-Liner and Visco-Gel as immersion time changes(P<.05). 3. In case of group L(less), higher mean surface roughness value of the stone model with statistical significance was observed compared to that of R(recommended) and M(more) group as immersion time changes(P<.05). Conclusion: We may conclude that as the retention period of time in oral cavity influences surface roughness of the stone model the most and as the kind of tissue conditioner and its P/L ratio may influence also, clinician should well understand the optimal retention period in oral cavity and choose the right tissue conditioner for the functional impression, thus making the functional impression with tissue conditioner usefully.

A Study on the Directorial Approaches of by Juan Mayorga (후안 마요르가 작 <하멜린> 연출적 접근방법 연구)

  • Lee, Seo-A;Cho, Joon-Hui
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.8
    • /
    • pp.161-180
    • /
    • 2021
  • The purpose of this study is to define Juan Mayorga's play Hamelin as a Post-Epic Theatre and to study the practical directing technique for Hamelin as a Post-Epic Theatre. Post-Epic Theatre, which appeared after the Post-drama, has the purpose of presenting social issues, communicating interactively between the actors and the audience, and making the audience think about the issues presented by the techniques of immersion and alienation. To this end, after examining the theoretical background of the Post-Epic Theatre, the characteristics of the Post-Epic Theatre of Hamelin were identified and based on these features, '1. Building a visual image based on a Cubistic multifocal concept' and '2. The concept of directing was derived from reinforcing Meta-drama through role-playing'. Next, the actual directing technique was discussed, focusing on the chain action of immersion and alienation that occurs in the form of communication between actors and audiences. '1. Presenting the characteristics of the work through Post-Epic Theatre scenography', '2. Co-existence of actors and characters', '3. Building and utilizing body-centered gestus' are them. As a result, demanding an active attitude from the audience, various experiences such as critical thinking of the audience, strengthening the characteristics of post-epic dramas, and active meaning creation were made possible.

Game Design Education using PIT(Product Innovation Test) Technique (PIT 기법을 활용한 게임 디자인 교육)

  • Yoon, Seon-Jeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1531-1537
    • /
    • 2021
  • The quality of the game can be evaluated by its fun and functional stability. Among them, the quality area for fun is the essence of the game, so it is a very important factor to be considered from the point of view of a game designer. Usually, fun games with high originality and immersion are designed in the early stages of development, such as idea generation and concept setting. At this time, making it possible to verify the fun factor of the game has an important influence on the success of the game. In this study, the case of using PIT technique when teaching fun element design to students who are starting to study game design was introduced and the effect was analyzed. It is expected that the PIT technique will be used more actively in the game design education field for high-quality and fun game design.

Implementation of High-definition Digital Signage Reality Image Using Chroma Key Technique (크로마키 기법을 이용한 고해상도 디지털 사이니지 실감 영상 구현)

  • Moon, Dae-Hyuk
    • Journal of Industrial Convergence
    • /
    • v.19 no.6
    • /
    • pp.49-57
    • /
    • 2021
  • Digital Signage and multi-view image system are used as the 4th media to deliver stories and information due to their strong immersion. A content image displayed on large Digital Signage is produced with the use of computer graphics, rather than reality image. That is because the images shot for content making have an extremely limited range of production and their limitation to high resolution, and thereby have difficulty being displayed in a large and wide Digital Signage screen. In case of Screen X and Escape that employ the left and right walls of in the center a movie theater as a screen, images are shot with three cameras for Digital Cinema, and are screened in a cinema with multi-view image system after stitching work is applied. Such realistic images help viewers experience real-life content. This research will be able to display high-resolution images on Digital Signage without quality degradation by using the multi-view image making technique of Screen X and Chroma key technique are showed the high-resolution Digital Signage content making method.

Measurement of the Shape in the Radioactive Area by Ultrasonic Wave Sensor

  • Park, Koon-Nam;Sim, Chuel-Muu;Park, Chang-Oong;Lee, Chang-Hee;Park, Jong-Hark
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.7
    • /
    • pp.927-934
    • /
    • 2002
  • The HANARO ( High-flux Advanced Neutron Application Reactor) has been operated since 1995. The Cold Neutron (CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure exactly the size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersed ultrasonic technique is considered as the best way to measure the thickness and the diameter of the CN hole. The 4-Axis manipulator was designed and fabricated for locating the ultrasonic sensors. The transducer of an ultrasonic sensor having 10 MHz frequency leads to high resolution as much as 0.03mm. The inside diameter and thickness of 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results show that the thickness and inside diameter of the CN hole is in the range of 3.3∼6.7mm and 156∼ 165mm, respectively. This data will be a good reference for the design of the cold neutron source facility.

${\beta}-Ag_3SI$ Single Crystal Membrane Electrode (${\beta}-Ag_3SI$ 단결정막 전극에 관한 연구)

  • Sin Doo-Soon;Seon-Cheon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.2
    • /
    • pp.86-94
    • /
    • 1984
  • The single crystal ion-selective electrode,$ {\beta}-Ag_3SI/PVC-THF $membrane electrode has showed a linear potential response to the activities of iodide ion (10-1${\sim}$10-7M). The $ {\beta}-Ag_3SI$ membrane electrode was compared with AgI/PVC-THF membrane and copper metal plate membrane electrodes. In order to measure the selectivity coefficient of the electrodes toward $Cl^-$ and $Br^-$, the separation and mixed solution method were employed. The potential-time curve was obtained by the usual immersion technique and pH effect was also examined. The orders of selectivity for $Br^-$, $Cl^-$ and stability of response time are ${\beta}-Ag_3SI/PVC-THF $membrane > AgI/PVC-THF membrane > copper metal plate membrane. These electrodes could be used as indicating electrodes in the potentiometric titration of a single halide and mixed halides with the standard solution of silver nitrate.

  • PDF

An Experimental Study on the Behavior of Twin-Spray with Flow Interaction in a Condensable Environment (주위기체내에서의 두 액체분무간의 유동간섭현상에 대한 정상적 고찰)

  • 이상룡;정태식;한기수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.326-334
    • /
    • 1986
  • The effects of flow interaction between adjacent sprays in twin-spray system on the spatial distribution of injected liquid (water) and drop size distribution in condensable (steam) environment were carefully observed through experiments. The spatial distribution of injected liquid in twin-spray system appears to be more uniform than the simple superposition of the spatial distributions of liquid obtained from each individual spray. Drop size distribution was obtained by using the immersion sampling technique. It was found that, in the twin-spray, the larger numbers of small drops are collected throughout the spraying region due to the increase of entrainment velocity of ambient steam compared with the case of simple superposition of each individual spray. Moreover, in the overlapped portion of the twin-spray, the drop size distribution was changed also due to the collision between large drops. As a result, the behavior of twin-spray system (and eventually multiple-spray system) can not be predicted precisely by simple superposition of the behaviors of each constituting spray. Hence, for the design of multiple spray system, the effect of flow interaction between sprays should be taken into account seriously.

Paddling Posture Correction System Using IMU Sensors

  • Kim, Kyungjin;Park, Chan Won
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.86-92
    • /
    • 2018
  • In recent times, motion capture technology using inertial measurement unit (IMU) sensors has been actively used in sports. In this study, we developed a canoe paddle, installed with an IMU and a water level sensor, as a system tool for training and calibration purposes in water sports. The hardware was fabricated to control an attitude heading reference system (AHRS) module, a water level sensor, a communication module, and a wireless charging circuit. We also developed an application program for the mobile device that processes paddling motion data from the paddling operation and also visualizes it. An AHRS module with acceleration, gyro, and geomagnetic sensors each having three axes, and a resistive water level sensor that senses the immersion depth in the water of the paddle represented the paddle motion. The motion data transmitted from the paddle device is internally decoded and classified by the application program in the mobile device to perform visualization and to operate functions of the mobile training/correction system. To conclude, we tried to provide mobile knowledge service through paddle sport data using this technique. The developed system works reasonably well to be used as a basic training and posture correction tool for paddle sports; the transmission delay time of the sensor system is measured within 90 ms, and it shows that there is no complication in its practical usage.

Tribological Properties of DLC for Die Applications

  • Lee, Kyu-Yong;Liu, Zhen-Hua
    • Design & Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.24-28
    • /
    • 2012
  • Friction and wear affect all processes involved in the extraction of materials and their conversion into finished products in the die applications such as drawing, extrusion etc. Originating phenomenon from the contact surface between the tool and workpiece, they are usually a hindrance to materials process operations which usually result in damaging the tools, increasing energy consumption, the contamination of processed material by wear particles and also some problems associated with technologies to control friction and wear. The most well established method to control friction and wear is by the application of lubricant such as fluorocarbon. Besides, a surface technique so-called surface modification can be applied to solve the tribology problems of the die applications for both the economical and ecological reasons. In this article, we applied DLC(diamond-like carbon) thin film on alumina ceramic for HT test using the PIID(plasma ion immersion deposition), 4 groups of test specimens were tested up to $200^{\circ}C$ which is a little higher than the normal working temperature of die application. Pin-on-disc tribo-tester was used to test the friction and surfaces were characterized by SEM and EDS and else, the morphology changes of DLC coatings were studied. The present work indicated that the DLC had a great potential to reduce the friction and wear in the alumina die application without lubricants.

  • PDF