• Title/Summary/Keyword: immediate implant loading

Search Result 91, Processing Time 0.023 seconds

Clinical application of a new systematic implant planning concept: A Clinical Report

  • Jeong, Seung-Mi;Chung, Chae-Heon;Engelke, Wilfried
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.6
    • /
    • pp.814-820
    • /
    • 2000
  • Statement of Problem. Commonly used classification systems do not inform for dentists the dimension of the available bone at a potential implant site although regarding a variety of morphologic and pathophysiologic aspects using schematic graphs. However, for the implantologist the availability of bone substance is most important independent whether it concerns the jaw basis or the alveolus. Purpose of Study. The present article refers to a new evaluation form, to analyze the available bone with regard to optional immediate loading site by site. According to a new systematic implant planning concept will be presented in two case reports. Results. The feasibility of the classification for planning and documentation of immediately loaded implants is presented in two case reports. Conclusion. The factor of bone support for immediate functional stability is important in dental implantology. The new systematic implant planning helps to systematically estimate the dimension (ASCIi classification) of the alveolus site by site to evaluate the possibility of immediate loading. The Gottingen classification thus aids to determine the degree of stability that can be expected for the planned solution.

  • PDF

Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study

  • Leesungbok, Richard;Seo, Jin-Ho;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.163-166
    • /
    • 2018
  • PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.

Evaluation of Bone Uptake on Tc-99m-MDP in Immediate and Delayed Dental Implants (즉시형과 지연형 치아 임플란트에서 Tc-99m-MDP의 Bone Uptake 평가)

  • 김중현;김명환;이원국;이재영;강성수;최석화
    • Journal of Veterinary Clinics
    • /
    • v.20 no.2
    • /
    • pp.207-211
    • /
    • 2003
  • This investigation aimed to determine the relative merit of osseointegration in immediate and delayed implantation in the dog mandible using radiography and bone scintigraphy. five adult mongrel dogs with a mean weight of 8.5 kg were used in this investigation. During the entire study period. all dogs were fed with a soft commercial diet and water ad libitum to minimize functional loading of the implant. Twenty titanium alloy systems 4 mm in diameter and 10 mm in length blasted with calcium phosphate were prepared for insertion. The second and third left mandibular premolars in each dog were extracted for the delayed implant insertion. Twelve weeks later, the second and third right mandibular premolars were extracted for the immediate implant insertion. Before the delayed and immediate implantation procedures and 0, 4, 8, and 12 weeks after the insertions, radiography and bone scintigraphy were conducted. Bone scans were obtained using a large field of view gamma camera equipped with a collimator about 3 hours after intravenous injection of Tc-99m-MDP to the dogs. All the dogs were evaluated weekly for inflammation, necrosis, and other of the bone or sort tissue. Significant macroscopic lesions were not detected. Radioisotope scintigraphy with Tc-99m-MDP hat proved to be a reliable method for measuring increased bone activity at specific skeleton tissue sites. In conclusion, osseointegration in peri-implant bone did not differ significantly between the immediate and delayed implant procedures during the experimental period. The immediate implant may be an alternative treatment of implant insertion in animals.

Guidance and rationale for the immediate implant placement in the maxillary molar

  • Kezia Rachellea Mustakim;Mi Young Eo;Ju Young Lee;Hoon Myoung;Mi Hyun Seo;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.1
    • /
    • pp.30-42
    • /
    • 2023
  • Objectives: While the reliability of immediate implant placement in the maxillary molar has been discussed, its significance is questionable. There have been no guidelines for case selection and surgical technique for successful treatment outcomes of immediate maxillary molar implants. Therefore, in this study, we classified alveolar bone height and socket morphology of the maxillary molar to establish guidelines for immediate implant placement. Materials and Methods: From 2011 to 2019, we retrospectively analyzed 106 patients with 148 immediate implants at the Department of Oral and Maxillofacial Surgery, Seoul National University Dental Hospital. Inclusion and exclusion criteria were applied, and patient characteristics and treatment results were evaluated clinically and radiologically. Results: A total of 29 tapered, sand-blasted, large-grit, and acid-etched (SLA) surfaces of implants were placed in 26 patients. The mean patient age was 64.88 years. Two implants failed and were reinstalled, resulting in a 93.10% survival rate. Fluctuating marginal bone level changes indicating bone regeneration and bone loss were observed in the first year following installation and remained stable after one year of prosthesis loading, with an average bone loss of 0.01±0.01 mm on the distal side and 0.03±0.03 mm on the mesial side. Conclusion: This clinical study demonstrated the significance of immediate implant placement in maxillary molars as a reliable treatment with a high survival rate using tapered SLA implants. With an accurate approach to immediate implantation, surgical intervention and treatment time can be reduced, resulting in patient satisfaction and comfort.

Hydroxyapatite-coated implant: Clinical prognosis assessment via a retrospective follow-up study for the average of 3 years

  • Jung, Jun-Hong;Kim, Sang-Yun;Yi, Yang-Jin;Lee, Bu-Kyu;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.85-92
    • /
    • 2018
  • PURPOSE. This research evaluated clinical outcomes of two types of hydroxyapatite (HA)-coated implants: OT (Osstem TS III-HA, Osstem implant Co., Busan, Korea) and ZM (Zimmer TSV-HA, Zimmer dental, Carlsbad, USA). MATERIALS AND METHODS. The research was conducted on 303 implants (89 of OT, 214 of ZM), which were placed from January 16, 2010 to December 20, 2012. The prognosis was evaluated in terms of success rates, survival rates, annual marginal bone loss, and implant stability quotients (ISQ). The samples were classified into immediate, early, conventional, and delayed groups according to the loading time. RESULTS. Overall, there were no significant differences between OT and ZM in success rates, survival rates, and annual marginal bone loss, except for the result of secondary stability. OT showed $77.83{\pm}8.23ISQ$, which was marginally higher than $76.09{\pm}6.90ISQ$ of ZM (P<.05). In terms of healing periods, only immediate loading showed statistically significant differences (P<.05). Differences between OT and ZM were observed in terms of two indices, the annual marginal bone loss ($0.17{\pm}0.58mm/year$ < $0.45{\pm}0.80mm/year$) and secondary stability ($84.36{\pm}3.80ISQ$ > $82.48{\pm}3.69ISQ$) (P<.05). OT and ZM did not have any statistically significant differences in early, conventional, and delayed loading (P>.05). CONCLUSION. OT (97.75%) and ZM (98.50%) showed relatively good outcomes in terms of survival rates. In general, OT and ZM did not show statistically significant differences in most indices (P>.05), although OT performed marginally better than ZM in the immediate loading and 1-stage surgery (P<.05).

Development of implant loading device for animal study about various loading protocol: a pilot study

  • Yoon, Joon-Ho;Park, Young-Bum;Cho, Yuna;Kim, Chang-Sung;Choi, Seong-Ho;Moon, Hong-Seok;Lee, Keun-Woo;Shim, June-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.227-234
    • /
    • 2012
  • PURPOSE. The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS. Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method, simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (${\mu}{\varepsilon}$) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS. The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION. Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study.

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

CT and scintigraphic evaluation of osseointegration following immediate versus delayed implantation in dogs (개에서 즉시형과 지연형 인공치아 식립후 골유합에 대한 CT와 신티그라피 평가)

  • Kim, Juoog-Hyun;Lee, Jae Yeong;Lee, Won-Guk;Oh, Won Young;Kim, So-Seob;Kang, Seong Soo;Choi, Seok Hwa
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.131-136
    • /
    • 2004
  • Osseointegration involves anchoring dental implants to stable bone rather than to soft-tissue. Clinical osseointegration is currently defined as the process whereby alloplastic material is asymptomatically and rigidly fixed and maintained in bone during functional loading. Full osseointegration is necessary for the success of long-term dental implants. Recent developments in computer assisted measurement of bone formation have improved maxillofacial examination and osseointegration. Computer assisted examination has also proved effective in dental implantology. This investigation was aimed to determine osseointegration in immediate and delayed implantation in the dog mandible using dental computed tomography (CT) and bone scintigraphy. Five adult (mean age of 2 years) mongrel dogs with a mean weight of 9.1 kg were used in this investigation. Titanium alloy implant systems with 4 mm in diameter and 10 mm in length were chosen for insertion. The second and third left mandibular premolars in each dog were extracted for the delayed implant insertion. Twelve weeks later, the second and third right mandibular premolars were extracted for the immediate implant insertion. Before the delayed and immediate implantation procedures and 0, 4, 8, and 12 weeks after the insertions, dental CT and scintigraphy were conducted. The CT and scintigraphic images indicate that reconstruction of bone surrounding of the immediate implant can be as successful as reconstruction of bone surrounding of the delayed implant.