• Title/Summary/Keyword: imaging protocol

Search Result 204, Processing Time 0.031 seconds

Anatomy and morphology of the nasopalatine canal using cone-beam computed tomography

  • Thakur, Arpita Rai;Burde, Krishna;Guttal, Kruthika;Naikmasur, Venkatesh G.
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.273-281
    • /
    • 2013
  • Purpose: This study was performed to evaluate the general anatomy and morphology of the nasopalatine canal using cone-beam computed tomography (CBCT) and to determine the human anatomic variability of the nasopalatine canal in relation to age and gender. Materials and Methods: The study included 100 subjects aged between 20 and 86 years who were divided into the following 3 groups: 1) 20-34 years old; 2) 35-49 years old; 3) ${\geq}50$ years old. The subjects were equally distributed between the genders. CBCT was performed using a standard exposure and patient positioning protocol. The data of the CBCT images were sliced in three dimensions. Image planes on the three axes (X, Y, and Z) were sequentially analyzed for the location, morphology and dimensions of the nasopalatine canal by two independent observers. The correlation of age and gender with all the variables was evaluated. Results: The present study did not reveal statistically significant differences in the number of openings at the nasal fossa; diameter of the nasal fossa openings; diameter of the incisive fossa; shape, curvature, and angulation of the canal as viewed in the sagittal sections; antero-posterior dimensions and length of the canal in the sagittal sections; or the level of division of the canal in the coronal plane by age. However, males and females showed significant differences in the length of the canal in the sagittal sections and level of the division of the canal in the coronal plane. Conclusion: The present study highlighted important variability observed in the anatomy and morphology of the nasopalatine canal.

Influence of voxel size on cone-beam computed tomography-based detection of vertical root fractures in the presence of intracanal metallic posts

  • Yamamoto-Silva, Fernanda Paula;de Oliveira Siqueira, Claudeir Felipe;Silva, Maria Alves Garcia Santos;Fonseca, Rodrigo Borges;Santos, Ananda Amaral;Estrela, Carlos;de Freitas Silva, Brunno Santos
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.177-184
    • /
    • 2018
  • Purpose: This study was performed to evaluate the influence of voxel size and the accuracy of 2 cone-beam computed tomography (CBCT) systems in the detection of vertical root fracture (VRF) in the presence of intracanal metallic posts. Materials and Methods: Thirty uniradicular extracted human teeth were selected and randomly divided into 2 groups(VRF group, n=15; and control group, n=15). The VRFs were induced by an Instron machine, and metallic posts were placed in both groups. The scans were acquired by CBCT with 4 different voxel sizes: 0.1 mm and 0.16 mm (for the Eagle 3D V-Beam system) and 0.125 mm and 0.2 mm (for the i-CAT system) (protocols 1, 2, 3, and 4, respectively). Interobserver and intraobserver agreement was assessed using the Cohen kappa test. Sensitivity and specificity were evaluated and receiver operating characteristic analysis was performed. Results: The intraobserver coefficients indicated good (0.71) to very good (0.83) agreement, and the interobserver coefficients indicated moderate (0.57) to very good (0.80) agreement. In respect to the relationship between sensitivity and specificity, a statistically significant difference was found between protocols 1 (positive predictive value: 0.710, negative predictive value: 0.724) and 3 (positive predictive value: 0.727, negative predictive value: 0.632) (P<.05). The least interference due to artifact formation was observed using protocol 2. Conclusion: Protocols with a smaller voxel size and field of view seemed to favor the detection of VRF in teeth with intracanal metallic posts.

A Case of Systemic Lupus Erythematosus with Recurrent Transverse Myelitis (재발횡단척수염과 동반한 전신홍반루푸스 1예)

  • Lee, Jun-Hwan;Park, Ki-Jong;Lee, Sang-Il;Kwon, Oh-Young;Kang, Heeyoung;Kang, Jong-Su;Park, Eu-Jung;Choi, Nack-Cheon;Lim, Byeong Hoon
    • Annals of Clinical Neurophysiology
    • /
    • v.9 no.1
    • /
    • pp.29-32
    • /
    • 2007
  • Recurrent transverse myelitis is a rare manifestation of systemic lupus erythematosus. Recurrent transverse myelitis presents the biggest diagnostic problem, since it is common manifestation of multiple sclerosis. But it can also be the only feature or first manifestation in systemic lupus erythematosus. Neurological manifestations and magnetic resonance imaging can be indistinguishable, and there are no specific diagnostic tools. Here we describe a 59-year-old female having a systemic lupus erythematosus with recurrent transverse myeltitis. No uniform therapeutic protocol exists for systemic lupus erythematous with transverse myelitis, and the prognosis is usually poor. We suggest that aggressive treatment (usually with pulses of methylprednisolone and cyclophosphamide) might improve the prognosis of systemic lupus erythematosus with transverse myeltis.

  • PDF

Design and Implementation of Multimedia Sensor Networks with Image Sensor (이미지 센서를 이용한 멀티미디어 센서 네트워크의 설계 및 구현)

  • Lee, Joa-Hyoung;Jo, Young-Tae;Jung, In-Bum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.3
    • /
    • pp.615-622
    • /
    • 2009
  • Advances in wireless communication and hardware technology have made it possible to manufacture high-performance tiny sensor nodes. More recently, the availability of inexpensive CMOS cameras that are able to capture multimedia data from the environment has fostered the development of Wireless Multimedia Sensor Networks (WMSNs). WMSN with the CMOS imaging sensor which is cheaper and consumes lower power than the CCD will not only enhance existing sensor network but also enable several new application such as multimedia surveillance sensor network, multimedia environment monitoring. This paper presents the design of a multimedia sensor network with the image sensor mote developed by us using the CMOS. Given new multimeida sensor network, the new image collecting protocol was tested and analyzed.

Radiopharmaceuticals for the Therapy of Metastatic Bone Pain (뼈전이의 방사성동위원소 통증치료)

  • Ahn, Byeong-Cheol
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.2
    • /
    • pp.82-89
    • /
    • 2006
  • Bone metastasis is a common sequelae of solid malignant tumors such as prostate, breast, lung, and renal cancers, which can lead to various complications, including fractures, hypercalcemia, and bone pain, as well as reduced performance status and quality of life it occurs as a result of a complex pathophysiologic process between host and tumor cells leading to cellular invasion, migration adhesion, and stimulation of osteoclastic and osteoblastic activity. Several sequelae occur as a result of osseous metastases and resulting bone pain can lead to significant debilitation. A multidisciplinary approach is usually required not only to address the etiology of the pain and its complicating factors but also to treat the patient appropriately. Pharmaceutical therapy of bone pain, includes non-steroidal analgesics, opiates, steroids, hormones, bisphosphonates, and chemotherapy. While external beam radiation therapy remains the mainstay of pain palliation of a solitary lesions, bone seeking radiopharmaceuticals have entered the therapeutic armamentarium for the treatment of multiple painful osseous lesions. $^{32}P,\;^{89}SrCl,\;^{153}Sm-EDTMP,\;^{188}Re/^{186}Re-HEDP,\;and\;^{177}Lu-EDTMP$ can be used to treat painful osseous metastases. These various radiopharmaceuticals have shown good efficacy in relieving bone pain secondary to bone metastasis. This systemic form of metabolic radiotherapy is simple to administer and complements other treatment options. This has been associated with improved mobility in many patients, reduced dependence on narcotic and non-narcotic analgesics, improved performance status and quality of life, and, in some studios, improved survival. All of these agents, although comprising different physical and chemical characteristics, offer certain advantages in that they are simple to administer, are well tolerated by the patient if used appropriately, and can be used alone or in combination with the other forms of treatment. This article illustrates the salient features of these radiopharmaceuticals, including the usual therapuetic dose, method of administration, and indications for use and also describe about the pre-management checklists, and jndication/contraindication and follow-up protocol.

Prospective Multicenter Feasibility Study of Laparoscopic Sentinel Basin Dissection after Endoscopic Submucosal Dissection for Early Gastric Cancer: SENORITA 2 Trial Protocol

  • Eom, Bang Wool;Yoon, Hong Man;Min, Jae Seok;Cho, In;Park, Ji-Ho;Jung, Mi Ran;Hur, Hoon;Kim, Young-Woo;Park, Young Kyu;Nam, Byung-Ho;Ryu, Keun Won;Sentinel Node Oriented Tailored Approach (SENORITA) Study Group
    • Journal of Gastric Cancer
    • /
    • v.19 no.2
    • /
    • pp.157-164
    • /
    • 2019
  • Purpose: Although standard radical gastrectomy is recommended after noncurative resection of endoscopic submucosal dissection (ESD) for early gastric cancer in most cases, residual tumor and lymph node metastasis have not been identified after surgery. The aim of this study is to evaluate the feasibility of sentinel node navigation surgery after noncurative ESD. Materials and Methods: This trial is an investigator-initiated, multicenter prospective phase II trial. Patients who underwent ESD for clinical stage T1N0M0 gastric cancer with noncurative resections were eligible. Qualified investigators who completed the prior phase III trial (SENORITA 1) are exclusively allowed to participate. In this study, 2 detection methods will be used: 1) intraoperative endoscopic submucosal injection of dual tracer, including radioisotope and indocyanine green (ICG) with sentinel basins detected using gamma-probe; 2) endoscopic injection of ICG, with sentinel basins detected using a fluorescence imaging system. Standard laparoscopic gastrectomy with lymphadenectomy will be performed. Sample size is calculated based on the inferior confidence interval of the detection rate of 95%, and the calculated accrual is 237 patients. The primary endpoint is detection rate, and the secondary endpoints are sensitivity and postoperative complications. Conclusions: This study is expected to clarify the feasibility of laparoscopic sentinel basin dissection after noncurative ESD. If the feasibility is demonstrated, a multicenter phase III trial will be initiated to compare laparoscopic sentinel node navigation surgery versus laparoscopic standard gastrectomy in early gastric cancer after endoscopic resection.

P2P Based Telemedicine System Using Thermographic Camera (열화상 카메라를 포함한 P2P 방식의 원격진료 시스템)

  • Kim, Kyoung Min;Ryu, Jae Hyun;Hong, Sung Jun;Kim, Hongjun
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.32 no.3
    • /
    • pp.547-554
    • /
    • 2022
  • Recently, the field of telemedicine is growing rapidly due to the COVID-19 pandemic. However, the cost of telemedicine services is relatively high, since cloud computing, video conferencing, and cyber security should be considered. Therefore, in this paper, we design and implement a cost-effective P2P-based telemedicine system. It is implemented using the widely used the open source computing platform, Raspberry Pi, and P2P network that frees users from security problems such as the privacy leakage by the central server and DDoS attacks resulting from the server/client architecture and enables trustworthy identifying connection system using SSL protocol. Also it enables users to check the other party's status including body temperature in real time by installing a thermal imaging camera using Raspberry Pi. This allows several medical diagnoses that requires visual aids. The proposed telemedicine system will popularize telemedicine service and meet the ever-increasing demand for telemedicine.

Assessment of DRL for Computed Tomography in Local Hospital (지역병원에서의 전산화단층촬영 검사에 대한 DRL 평가)

  • Choi, Seok-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.619-625
    • /
    • 2022
  • In the field of imaging medicine, computed tomography is one of the most common test methods and one of the most frequently used test methods in hospitals. However, it is accompanied by a very high radiation exposure compared to other test methods. In order to reduce exposure, CT scans should be performed only when absolutely necessary, and even if the tests are performed because they are absolutely necessary, a protocol that serves the purpose of the test and allows the test to be performed in a small dose should be used. In this study, we wanted to learn about the most up-to-date radiation dose usage information used by the region's leading general hospitals and develop a diagnostic reference level (DRL). In the experimental results, the Head CT and Abdomen CT tests showed that DLP was higher than the NRPB (U.K) and Korean DRL. The DLP values used by Chest CT were low for all 3 types of CT devices. The hospital found that efforts to reduce exposure should be made during CT examinations, and in particular, Head CT and Abdomen CT determined that efforts to reduce exposure were necessary.

A Case Report of Traditional Korean Medicine-Based Integrative Oncology of Recurrent Cervical Cancer (재발된 자궁경부암 환자의 한의 기반 통합 암 치료에 대한 증례보고)

  • Joo, Han-eum;Park, Ji-hye;Song, Si-yeon;Cho, Young-min;Park, So-jeong;Yoo, Hwa-seung
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.4
    • /
    • pp.751-760
    • /
    • 2022
  • Objective: To show a decrease in tumor recurrence and improvement in quality of life in patients with recurrent cervical cancer. Method: A 58-year-old female patient diagnosed with recurrent cervical cancer in February 2021 was treated for 14 months with integrative cancer treatment (ICT) to decrease the tumor size and improve chemotherapy-induced peripheral neuropathy (CIPN) and nausea. The patient underwent chemotherapy or concomitant chemoradiation therapy (CCRT) with ICT. Radiologic outcomes were assessed by abdomen & pelvis computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography-computed tomography (PET-CT) based on the Response Evaluation Criteria in Solid Tumors (RECIST) protocol. Clinical outcomes were assessed by the National Cancer Institute Common Terminology Criteria for Adverse Event (NCI-CTCAE), Eastern Cooperative Oncology Group (ECOG), and a numeric rating scale (NRS). Result: During the 14 months of treatment, the size and metabolic activity of the recurrent tumor decreased and underwent partial remission based on RECIST. The NRS scores for CIPN and nausea were improved, and the ECOG score improved from grade 2 to 1. No serious side effects of grade 3 or higher were noted on the NCI-CTCAE test. Conclusion: This case suggests that ICT may have a synergetic effect with chemotherapy or radiotherapy for recurrent cervical cancer.

Somatosensory evoked potentials are abnormal with plagiocephaly

  • Harma, Maiju;Lauronen, Leena;Leikola, Junnu;Hukki, Jyri;Saarikko, Anne
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.2
    • /
    • pp.59-63
    • /
    • 2022
  • Background: Deformational plagiocephaly is usually managed conservatively, as it tends to improve over time and with the use of conservative measures. However, before the year 2017 we operated on patients with severe plagiocephaly and neurological symptoms at the Helsinki Cleft Palate and Craniofacial Center. Methods: Of the 20 infants with severe deformational plagiocephaly and neurological symptoms referred to us between 2014 and 2016, 10 underwent cranioplasty open reshaping of the posterior cranial vault. The parents of the last 10 patients were given information on the natural history of the condition and the patients were followed up with an outpatient protocol. The aim of this study was to gain information on the brain electrophysiology and recovery of patients after total cranial vault reconstruction by measuring the electroencephalogram (EEG) somatosensory evoked potentials (SEP; median nerve). Results: Of the 10 participants in the operation arm, six had abnormal SEP at least on the affected cerebral hemisphere and all SEPs were recorded as normal when controlled postoperatively. In the follow-up arm, eight out of 10 participants had abnormal SEP at the age of approximately 24 months, and all had normalized SEPs at control visits. Conclusion: Our data suggest that cranioplasty open reshaping of the posterior cranial vault did not affect abnormal SEP-EEG recordings. We have abandoned the operations in deformational plagiocephaly patients due to findings suggesting that expanding cranioplasty is not beneficial for brain function in this patient group.