• Title/Summary/Keyword: imaging protocol

Search Result 204, Processing Time 0.03 seconds

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

Measurement and Analysis of Pediatric Patient Exposure Dose Using Glass dosimeter and a PC-Based Monte Carlo Program (Glass dosimeter와 PCXMC Program을 이용한 소아피폭선량 측정 및 분석)

  • Kim, Young-Eun;Lee, Jeong-Hwa;Hong, Sun-Suk;Lee, Kwan-Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 2012
  • Exposed dose of young child should be managed necessarily. Young child is more sensitive than adult of a Radioactivity, especially, and lives longer than adult. Must reduce exposed dose which follows The ALARA(As Low As Reasonably Achievable)rule is recommended by ICRP(International Commission on Radiological Protection)within diagnostic useful range. Therefore, We have to prepare Pediatric DRL(Diagnostic Reference Level) in Korea as soon as possible. Consequently, in this study, wish to estimate organ dose and effective dose using PCXMC Program(a PC-Based Monte Carlo Program), and measure ESD(Entrance surface dose)and organ dose using Glass dosimeter, and then compare with DRL which follows EC(European Commission)and NRPB(National Radiological Protection Board). Using glass dosimeter and PCXMC programs conforming to the International Committee for Radioactivity Prevention(ICRP)-103 tissue weighting factor based on the item before the organs contained in the Chest, Skull, Pelvis, Abdomen in the organ doses and effective dose and dose measurements were evaluated convenience. In a straightforward way to RANDO phantom inserted glass dosimeter(GD352M)by using the hospital pediatric protocol, and in a indirect way was PCXMC the program through a virtual simulation of organ doses and effective dose were calculated. The ESD in Chest PA is 0.076mGy which is slightly higher than the DRL of NRPB(UK) is 0.07mGy, and is lower than the DRL of EC(Europe) which is 0.1mGy. The ESD in Chest Lateral is 0.130mGy which is lower than the DRL of EC(Europe) is 0.2mGy. The ESD in Skull PA is 0.423mGy which is 40 percent lower than the DRL of NRPB(UK) is 1.1mGy and is 28 percent lower than the DRL of EC(Europe) is 1.5mGy. The ESD in Skull Lateral is 0.478mGy which is half than the DRL of NRPB(UK) is 0.8mGy, is 40 percent lower than the DRL of EC(Europe) is 1mGy. The ESD in Pelvis AP is 0.293mGy which is half than the DRL of NRPB(UK) is 0.60mGy, is 30 percent lower than the DRL of EC(Europe)is 0.9mGy. Finally, the ESD in Abdomen AP is 0.223mGy which is half than the DRL of NRPB(UK) is 0.5mGy, and is 20 percent lower than the DRL of EC is 1.0mGy. The six kind of diagnostic radiological examination is generally lower than the DRL of NRPB(UK)and EC(Europe) except for Chest PA. Shouldn't overlook the age, body, other factors. Radiological technician must realize organ dose, effective dose, ESD when examining young child in hospital. That's why young child is more sensitive than adult of a Radioactivity.

  • PDF

A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating (Non Breathe Hold Technique를 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction(PACE)기법과 Respiration Trigger Gating(RTG) 기법의 비교)

  • Goo, Eun-Hee;Jeong, Hong-Ryang;Im, Cheong-Hwan;Kweon, Dae-Cheol;Jo, Jeong-Keun;Lee, Man-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • Recently, MR Cholangiography used mainly bu controlling of patient's breathing. There is breathing hold techniques to get images within shopt time and gating technique adjusted to respiration cycle for high resolution image. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG thchniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to potimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ratio. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE, On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presence's artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnistic quality.

  • PDF

The Effect of Adding Kami-guibi-tang to Acetylcholinesterase Inhibitor Treatment on the Cognitive Function of Mild Alzheimer's Disease Patients: Study Protocol of a Randomized, Placebo-Controlled, Double-Blind Pilot Trial

  • Yang, Seung-bo;Kim, Ha-ri;Shin, Hee-yeon;Kim, Jeong-hwa;Lee, Chang-woo;Jahng, Geon-ho;Park, Seong-uk;Ko, Chang-nam;Park, Jung-mi
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.3
    • /
    • pp.326-338
    • /
    • 2020
  • Background: Alzheimer's disease (AD) is a chronic neurodegenerative disease that causes disorientation, mood swings, problems with language, and difficulty remembering recent events. Acetylcholinesterase inhibitors (AchEIs) and memantine have been used to slow the course of the disease, but they can neither modify its progression nor prevent disease onset. Previous studies have suggested that Kami-guibi-tang (KGT) could be beneficial for supporting cognitive function in AD patients, but few clinical trials have been published. This pilot study aimed to evaluate the effect of KGT in improving cognitive function in AD patients. Methods: The study will be a randomized, placebo-controlled, double-blind, single-center trial conducted using subjects diagnosed with mild AD by neurologists. Study subjects will be randomly assigned to either a treatment or control group. The treatment group will receive KGT granules for 24 weeks, while the control group will receive placebo granules. AchEI administration will be maintained in both groups during the entirety of the study. Subjects will be assessed using the following exams: the Seoul Neuropsychologic Screening Battery (SNSB) for cognitive function; brain magnetic resonance imaging (MRI) for brain metabolite, neurotransmitter, and cerebral blood flow (CBF) measurements; the Korean version of Quality of Life-Alzheimer's Disease (KQol-AD) for quality of life; the Caregiver-Administered Neuropsychiatric Inventory (CGA-NPI) for neurobehavioral symptoms; blood tests for amyloid and tau proteins and general blood parameters; and electrocardiography (ECG) before and after taking the medication. Discussion: Our findings will provide insight into the feasibility of large-scale trials to consolidate evidence for the efficacy of KGT for dementia treatment. Registration ID in CRIS: KCT0002904 (Clinical Research Information Service of the Republic of Korea).

Expert Opinions and Recommendations for the Clinical Use of Quantitative Analysis Software for MRI-Based Brain Volumetry (뇌 자기공명영상 뇌용적 분석 소프트웨어의 임상적 적용에 대한 전문가 의견과 권고안)

  • Ji Young Lee;Ji Eun Park;Mi Sun Chung;Se Won Oh;Won-Jin Moon;Aging and Neurodegeneration Imaging (ANDI) Study Group, Korean Society of Neuroradiology (KSNR)
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1124-1139
    • /
    • 2021
  • The objective assessment of atrophy and the measurement of brain volume is important in the early diagnosis of dementia and neurodegenerative diseases. Recently, several MR-based volumetry software have been developed. For their clinical application, several issues arise, including the standardization of image acquisition and their validation of software. Additionally, it is important to highlight the diagnostic performance of the volumetry software based on expert opinions. We instituted a task force within the Korean Society of Neuroradiology to develop guidelines for the clinical use of MR-based brain volumetry software. In this review, we introduce the commercially available software and compare their diagnostic performances. We suggest the need for a standard protocol for image acquisition, the validation of the software, and evaluations of the limitations of the software related to clinical practice. We present recommendations for the clinical applications of commercially available software for volumetry based on the expert opinions of the Korean Society of Neuroradiology.

Survey of Current Status of Quality Control of Gamma Cameras in Republic of Korea (감마카메라 정도관리 실태 조사)

  • Choe, Jae-Gol;Joh, Cheol-Woo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.314-322
    • /
    • 2008
  • Purpose: It is widely recognized that good quality control (QC) program is essential for adequate imaging diagnosis using gamma camera. The purpose of this study is to survey the current status of QC of gamma cameras in Republic of Korea for implementing appropriate nationwide quality control guidelines and programs. Methods: A collection of data is done for personnel, equipment and appropriateness of each nuclear medicine imaging laboratory's quality control practice. This survey is done by collection of formatted questionnaire by mails, emails or interviews. We also reviewed the current recommendations concerning quality assurance by international societies. Results: This survey revealed that practice of quality control is irregular and not satisfactory. The irregularity of the QC practice seems due partly to the lack of trained personnel, equipment, budget, time and hand-on guidelines. Conclusion: The implementation of QC program may cause additional burden to the hospitals, patients and nuclear medicine laboratories. However, the benefit of a good QC program is obvious that the hospitals can provide good quality nuclear medicine imaging studies to the patients. It is important to use least cumbersome QC protocol, to educate the nuclear medicine and hospital administrative personnel concerning QC, and to establish national QC guidelines to help each individual nuclear medicine laboratory.

Pericardial Tamponade following Perihepatic Gauze Packing for Blunt Hepatic Injury (둔상성 간손상 환자의 손상 통제술 후 발생한 심낭압전)

  • Ye, Jin Bong;Sul, Young Hoon;Go, Seung Je;Kwon, Oh Sang;Kim, Joong Suck;Park, ang Soon;Ku, Gwan Woo;Lee, Min Koo;Kim, Yeong Cheol
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.211-214
    • /
    • 2015
  • The primary and secondary survey was designed to identify all of a patient's injuries and prioritize their management. However 15 to 22.3% of patient with missed injuries had clinically significant missed injuries. To reduce missed injury, special attention should be focused on patients with severe anatomical injury or obtunded. Victims of blunt trauma commonly had multiple system involvement. Some reports indicate that inexperience, breakdown of estalished protocol, clinical error, and restriction of imaging studies may be responsible for presence of missed injury. The best way of reducing clinical significant of missed injuries was repeated clinical assessment. Here we report a case of severe blunt hepatic injury patient and pericardial injury that was missed in primary and secondary survey. After damage control surgery of hepatic injury, she remained hemodynamically unstable. Further investigation found cardiac tamponade during intensive care. This was managed by pericardial window operation through previous abdominal incision and abdominal wound closure was performed.

  • PDF

Dosimetric Verification for Primary Focal Hypermetabolism of Nasopharyngeal Carcinoma Patients Treated with Dynamic Intensity-modulated Radiation Therapy

  • Xin, Yong;Wang, Jia-Yang;Li, Liang;Tang, Tian-You;Liu, Gui-Hong;Wang, Jian-She;Xu, Yu-Mei;Chen, Yong;Zhang, Long-Zhen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.985-989
    • /
    • 2012
  • Objective: To make sure the feasibility with $^{18F}FDG$ PET/CT to guided dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma patients, by dosimetric verification before treatment. Methods: Chose 11 patients in III~IVA nasopharyngeal carcinoma treated with functional image-guided IMRT and absolute and relative dosimetric verification by Varian 23EX LA, ionization chamber, 2DICA of I'mRT Matrixx and IBA detachable phantom. Drawing outline and making treatment plan were by different imaging techniques (CT and $^{18F}FDG$ PET/CT). The dose distributions of the various regional were realized by SMART. Results: The absolute mean errors of interest area were $2.39%{\pm}0.66$ using 0.6cc ice chamber. Results using DTA method, the average relative dose measurements within our protocol (3%, 3 mm) were 87.64% at 300 MU/min in all filed. Conclusions: Dosimetric verification before IMRT is obligatory and necessary. Ionization chamber and 2DICA of I'mRT Matrixx was the effective dosimetric verification tool for primary focal hyper metabolism in functional image-guided dynamic IMRT for nasopharyngeal carcinoma. Our preliminary evidence indicates that functional image-guided dynamic IMRT is feasible.

Clinical Study of the Efficacy of Combined Western-Oriental Medicine for Gastric Cancer and Hepatocellular Carcinoma (위암 및 간암환자의 치료에 있어 양.한방 협진의 효과에 관한 임상시험)

  • Lee, Chong-In;Shim, Kwang-Yong;Kim, Ho-Young;Choi, Seo-Young;Bang, Dae-Geon;Cho, Kyung-Sook
    • THE JOURNAL OF KOREAN ORIENTAL ONCOLOGY
    • /
    • v.7 no.1
    • /
    • pp.117-129
    • /
    • 2001
  • Objectives: We compared the therapeutic response, the treatment-related toxicity, and the improvement of subjective symptoms between the chemotherapy alone group and the western-oriental combined treatment group and evaluated the role of oriental medicine for the improvement of chemotherapy-related toxicity in the advanced gastric cancer and hepatocellular carcinoma. Methods: We evaluated 36 gastric cancer or hepatocellular carcinoma patients(chemotherapy alone group 25 patients, combined treatment group 11 patients) who had been treated in Wonju Christian Hospital and Hana Hospital of Oriental Medicine between June 1999 and October 2000. Enrolled patients' general medical records, results of laboratory and imaging studies, treatment-related toxicities, and subjective symptoms were recorded regularly according to the planned protocol. Therapeutic responses were estimated according to the WHO response criteria and the changes of tumor marker value such as CEA, CA 72-4 and AFP. Results: 1. There was no significant difference of therapeutic response by the WHO response criteria between the two groups(p=.459). 2. There was a significant decrease of tumor marker value in the combined treatment group compared to the chemotherapy alone group(p=.023). 3. There was less comprehensive treatment-related toxicity in the combined treatment group compared to the chemotherapy alone group(p=.037), but there was not a significant difference of comprehensive improvement of subjective symptoms between the two groups(p=.091). Conclusions: Based on the above results, we could expect the possibility of improvements in therapeutic response and treatment-related toxicity with the western-oriental combined anticancer treatment.

  • PDF

How does duration of curing affect the radiopacity of dental materials?

  • Bejeh Mir, Arash Poorsattar;Bejeh Mir, Morvarid Poorsattar
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.89-93
    • /
    • 2012
  • Purpose : Clinicians commonly encounter cases in which it is difficult to determine whether adjacent radiopacities are normal or pathologic. The ideal radiopacity of composite resin is equal to or higher than that of the same thickness of aluminum. We aimed to investigate the possible effects of different curing times on the post-24-hour radiopacity of composite resins on digital radiographs. Materials and Methods : One mm thick samples of Filtek P60 and Clearfil resin composites were prepared and cured with three regimens of continuous 400 mW/$cm^2$ irradiance for 10, 20 and 30 seconds. Along with a 12-step aluminum step wedge, digital radiographs were captured and the radiopacities were transformed to the equivalent aluminum thicknesses. Data were compared by a general linear model and repeated-measures of ANOVA. Results : Overall, the calculated equivalent aluminum thicknesses of composite resins were increased significantly by doubling and tripling the curing times (F(2,8)=8.94, p=0.002). Notably, Bonferroni post-hoc tests confirmed that the radiopacity of the cured Filtek P60 was significantly higher at 30 seconds compared with 10 seconds (p=0.04). Although the higher radiopacity was observed by increasing the time, other comparisons showed no statistical significance (p>0.05). Conclusion : These results supported the hypothesis that the radiopacity of resin composites might be related to the duration of light curing. In addition to the current standards for radiopacity of digital images, defining a standard protocol for curing of dental materials should be considered, and it is suggested that they should be added to the current requirements for dental material.