• 제목/요약/키워드: imaging property

검색결과 154건 처리시간 0.034초

Research on Multiple-image Encryption Scheme Based on Fourier Transform and Ghost Imaging Algorithm

  • Zhang, Leihong;Yuan, Xiao;Zhang, Dawei;Chen, Jian
    • Current Optics and Photonics
    • /
    • 제2권4호
    • /
    • pp.315-323
    • /
    • 2018
  • A new multiple-image encryption scheme that is based on a compressive ghost imaging concept along with a Fourier transform sampling principle has been proposed. This further improves the security of the scheme. The scheme adopts a Fourier transform to sample the original multiple-image information respectively, utilizing the centrosymmetric conjugation property of the spatial spectrum of the images to obtain each Fourier coefficient in the most abundant spatial frequency band. Based on this sampling principle, the multiple images to be encrypted are grouped into a combined image, and then the compressive ghost imaging algorithm is used to improve the security, which reduces the amount of information transmission and improves the information transmission rate. Due to the presence of the compressive sensing algorithm, the scheme improves the accuracy of image reconstruction.

구리 잉크의 소성 특성 향상 (Improve the sintering property of copper inks.)

  • 송영아;김동훈;김성진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.66-66
    • /
    • 2010
  • 잉크젯용 저온 Cu ink의 소성 특성을 향상 시키기 위해 소성 분위기롤 조절 하였다. 일반적으로 Cu는 산화가 잘되는 물질로 환원 분위기에서 소성이 이루어져야만 하기 때문에 acid, alcohol, aldehyde, ether와 같은 환원제를 소성시 사용하였다. 또한 1종의 환원제가 아닌 2종의 환원제롤 일정 비율로 섞음으로써 환원력를 조절하여 소성 품질을 향상 시킬 수 있었으며, 이러한 환원 분위기 조절을 통하여 300도 이하 저온에서 소성이 가능하였다. 또한 optical microscopy와 field emission scanning electron microscopy를 통해 막 품질과 미세조직의 치밀도를 확인하였고 배선 재료로써의 적용을 위해 resistance를 측정 비교하였다.

  • PDF

선형 파면을 이용한 새로운 합성구경 기법 (A New Synthetic Aperture Technique Using Linear Wave Fronts)

  • 장진호;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권4호
    • /
    • pp.321-330
    • /
    • 2001
  • In this paper, we propose a new synthetic aperture focusing scheme for improving the lateral resolution which is one of the most important factors determining the quality of ultrasound imaging. The proposed scheme enables full round-trip dynamic focusing with approximately limited property. This properties are obtained through transmitting plane waves of which the traveling angle varies with the receive subaperture position, as opposed to stepping the spherical wave source across an array in other synthetic aperture focusing schemes, and employing dynamic focusing in receive. In this paper, the properties of the proposed scheme is analyzed in which a hypothetical infinite line source is used to transmit the plane waves and verified through computer simulation results. Also, we show that the proposed scheme is realizable with an array transducer with a finite aperture size. In summary, it is shown through comparison between the field contours of the proposed scheme and the conventional scheme that the proposed scheme can improve greatly the lateral resolution of ultrasound imaging.

  • PDF

Neural Network Image Reconstruction for Magnetic Particle Imaging

  • Chae, Byung Gyu
    • ETRI Journal
    • /
    • 제39권6호
    • /
    • pp.841-850
    • /
    • 2017
  • We investigate neural network image reconstruction for magnetic particle imaging. The network performance strongly depends on the convolution effects of the spectrum input data. The larger convolution effect appearing at a relatively smaller nanoparticle size obstructs the network training. The trained single-layer network reveals the weighting matrix consisting of a basis vector in the form of Chebyshev polynomials of the second kind. The weighting matrix corresponds to an inverse system matrix, where an incoherency of basis vectors due to low convolution effects, as well as a nonlinear activation function, plays a key role in retrieving the matrix elements. Test images are well reconstructed through trained networks having an inverse kernel matrix. We also confirm that a multi-layer network with one hidden layer improves the performance. Based on the results, a neural network architecture overcoming the low incoherence of the inverse kernel through the classification property is expected to become a better tool for image reconstruction.

관절염 진단용 광음향 이미징 시스템 개발을 위한 선행 연구 (A Preliminary Study on Developing a Photoacoustic Imaging System for Inflammatory Arthritis Diagnosis)

  • 윤종인;박지원
    • The Journal of Korean Physical Therapy
    • /
    • 제22권4호
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The goal of this study was to investigate the feasibility for the early diagnosis of inflammatory arthritis by the reconstruction of three-dimensional photoacoustic imaging with a tissue phantom. Methods: Q-switched Nd:YAG laser (l = 532 nm) was applied to a tissue phantom to generate photoacoustic waves, and the acquired photoacoustic signals at different positions around the sample were used to recombine the distribution of the optical absorption and the images were subsequently generated through a reconstruction algorithm. Results: From the acquired photoacoustic signals, the surface andinner core of the phantom was clearly distinguished. Furthermore, the back-projection algorithm was able to reconstruct two-dimensional and three-dimensional photoacoustic images that contained the optical absorption property information of the tissue phantom. Conclusion: The results indicate that the photoacoustic imaging technique has many advantages such as high optical contrast and high acoustic resolution. The acquired images can be used for the early diagnosis of inflammatory arthritis by the structural information obtained from the region of interest.

테라헤르츠 이미징 기술 및 그 응용 분야 (Terahertz Imaging Technology and Applications)

  • 김무건;이의수;박동우;최다혜;이일민;신준환;김영호;김정수;조진철;김영훈;곽동용;박경현
    • 전자통신동향분석
    • /
    • 제36권3호
    • /
    • pp.97-105
    • /
    • 2021
  • The terahertz wave (THz wave) is a band between infrared and microwaves and is defined as an electromagnetic wave having a frequency of 0.1 to 10 THz band. THz waves have the property of transmitting nonpolar materials, which the visible light cannot be transmitted, such as ceramics, plastics, and paper; and the photon energy is low, such as several meV. For this reason, non-destructive testing equipment based on THz imaging technology can be applied to the industrial field. Recently, THz imaging technology was applied in wide industrial fields, such as automobiles, batteries, food, medical, and security, and being actively studied. In this paper, we describe the research trends of terahertz imaging technology and experimental results. Furthermore, we summarize the recent commercialized terahertz camera. Finally, we present the research results in the field of the human security scanner system.

Measurement of Imaging Property of Flat-Panel Detector

  • Matsumoto, Masao;Suekane, Kouji;Maeda, Kouji;Ogata, Yuji;Inamura, Kiyonari;Kanai, Kouzo;Kanamori, Hitoshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.385-388
    • /
    • 2002
  • We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curves, Modulation Transfer Function (MTF), Wiener spectra (WS), Noise Equivalent Quanta (NEQ) and Detective Quantum Efficiency (DQE)) for the direct type and indirect type of Flat-Panel Detector (FPD). First, the digital and overall characteristic curves of the both types of FPD had more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of the direct-type FPD were superior to those of the indirect-type FPD. Third, for identical exposures, the digital and overall WS of the direct-type FPD were similar or worse than those of the indirect-type FPD, and for larger exposure, the digital WS of the both types of FPD were smaller, but overall WS of the both types of FPD were larger. Fourth, the digital and overall NEQ and DQE of the direct-type FPD were worse than both NEQ and DQE of the indirect-type FPD at lower spatial frequencies, but were better at higher spatial frequencies.

  • PDF

자기공명 탄성계수 영상법을 위한 진동기의 개발 및 기초실험 (Development of Vibrator for Magnetic Resonance Elastography)

  • 이태휘;서용선;김영태;이병일;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.75-83
    • /
    • 2007
  • Elasticity is an important physical property of biological tissues. Differences in elasticity can help facilitate the diagnosis of tumors and their extent. Magnetic Resonance Elastography (MRE) tries to visualize images of tissue elasticity by externally applying shear stress on the surface of an imaging object. Applied shear stress induces internal displacements that can be measured from MR phase images. In order to conduct MRE imaging experiments, we need to first develop a vibrator. We found that there does not exist enough technical information to design the MRE vibrator. In this paper, we describe the theory, design and construction of an MRE vibrator. We report the performance of the developed vibrator using two different test methods. We found that the vibrator successfully induces enough internal displacements that can be imaged using an MRI scanner. We suggest future studies of numerous MRE imaging experiments using the vibrator.

Wood Identification of Historical Architecture in Korea by Synchrotron X-ray Microtomography-Based Three-Dimensional Microstructural Imaging

  • HWANG, Sung-Wook;TAZURU, Suyako;SUGIYAMA, Junji
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권3호
    • /
    • pp.283-290
    • /
    • 2020
  • For visual inspection-based wood identification, optical microscopy techniques typically require a relatively large sample size, and a scanning electron microscope requires a clean surface. These novel techniques experience limitations for objects with highly limited sampling capabilities such as important and registered wooden cultural properties. Synchrotron X-ray microtomography (SR-µCT) has been suggested as an effective alternative to avoid such limitations and various other imaging issues. In this study, four pieces of wood fragments from wooden members used in the Manseru pavilion of Bongjeongsa temple in Andong, Korea, wereused for identification. Three-dimensional microstructural images were reconstructed from these small wood samples using SR-µCT at SPring-8. From the analysis of the reconstructed images, the samples were identified as Zelkova serrata, Quercus sect. Cerris, and Pinus koraiensis. The images displayed sufficient spatial resolution to clearly observe the anatomical features of each species. In addition, the three-dimensional imaging allowed unlimited image processing.

POLAR EXPONENTIAL GRID와 장방형격자 영상시스템의 영상분해도 및 영상처리능력 비교 (A Comparison of System Performances Between Rectangular and Polar Exponential Grid Imaging System)

  • Jae Kwon Eem
    • 전자공학회논문지B
    • /
    • 제31B권2호
    • /
    • pp.69-79
    • /
    • 1994
  • The conventional machine vision system which has uniform rectangular grid requires tremendous amount of computation for processing and analysing an image especially in 2-D image transfermations such as scaling, rotation and 3-D reconvery problem typical in robot application environment. In this study, the imaging system with nonuiformly distributed image sensors simulating human visual system, referred to as Ploar Exponential Grid(PEG), is compared with the existing conventional uniform rectangular grid system in terms of image resolution and computational complexity. By mimicking the geometric structure of the PEG sensor cell, we obtained PEG-like images using computer simulation. With the images obtained from the simulation, image resolution of the two systems are compared and some basic image processing tasks such as image scaling and rotation are implemented based on the PEG sensor system to examine its performance. Furthermore Fourier transform of PEG image is described and implemented in image analysis point of view. Also, the range and heading-angle measurement errors usually encountered in 3-D coordinates recovery with stereo camera system are claculated based on the PEG sensor system and compared with those obtained from the uniform rectangular grid system. In fact, the PEC imaging system not only reduces the computational requirements but also has scale and rotational invariance property in Fourier spectrum. Hence the PEG system has more suitable image coordinate system for image scaling, rotation, and image recognition problem. The range and heading-angle measurement errors with PEG system are less than those of uniform rectangular rectangular grid system in practical measurement range.

  • PDF