• Title/Summary/Keyword: imaging methods

Search Result 4,718, Processing Time 0.037 seconds

Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium (심근관류 SPECT의 정량적 분석에서 관류정량값 정상변이의 고려: 생존심근 평가에서의 유용성)

  • Paeng, Jin-Chul;Lim, Il-Han;Kim, Ki-Bong;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.285-291
    • /
    • 2008
  • Purpose: Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. Materials and Methods: In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F = 28:27) of low-likelihood for coronary artery disease were enrolled and $^{201}TI$ rest/$^{99m}Tc$-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. $^{201}TI$ rest/$^{99m}Tc$-MIBI stress / $^{201}TI$ 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, $Q_{delay}$ (perfusion measurement), ${\Delta}_{delay}$ ($Q_{delay}$ - m) and $Z_{delay}$ (($Q_{delay}$ - m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Results: Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was $51.8{\pm}6.5$ and the highest segmental perfusion was $87.0{\pm}5.9$, and they are $58.7{\pm}8.1$ and $87.3{\pm}6.0$, respectively in women. In the viability assessment $Q_{delay}$ showed AUC of 0.633, while those for ${\Delta}_{delay}$ and $Z_{delay}$ were 0.735 and 0.716, respectively. The AUCs of ${\Delta}_{delay}$ and $Z_{delay}$ were significantly higher than that of $Q_{delay}$ (p = 0.001 and 0.018, respectively). The diagnostic performance of ${\Delta}_{delay}$, which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. Conclusion: On automatic quantification of myocardial perfusion SPECT, the normal variation of perfusion measurements were considerable among segments. In the viability assessment, the parameters considering normal variation showed better diagnostic performance than the direct perfusion measurement. This study suggests that consideration of normal variation is important in the analysis of measurements on quantitative myocardial perfusion SPECT.

Difference in F-18 FDG Uptake According to the Patterns of CT-Based Diagnosed Pulmonary Lymphangitic Carcinomatosis in Patients with Lung Cancer (폐암환자에 있어 CT상으로 진단된 폐림프관성암종증의 형태에 따른 F-18 FDG 섭취의 차이)

  • Jun, Sung-Min;Kim, Yong-Ki;Kim, In-Ju;Kim, Seong-Jang;Nam, Hyun-Yeol;Kim, Bum-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.292-300
    • /
    • 2008
  • Purpose: Our purpose was to evaluate F-18 FDG uptake in pulmonary lymphangitic carcinomatosis (PLC) according to CT findings and histology of lung cancer. Materials and Methods: Thirty-three lung cancer patients with PLC were enrolled in this retrospective study. All the patients had a CT-based diagnosis of PLC. Chest CT findings of PLC were classified on the basis of involvement of axial interstitium. We categorized the involvement of axial interstitium as group 1, and the involvement of peripheral interstitium only as group 2. Visual and semiquantitative analyses by F-18 FDG PET/CT were performed in the PLC lesions. At first, we analyzed the F-18 FDG uptake in the PLC by visual assessment. If abnormal uptake was seen in the PLC, we drew regions of interest in the PLC lesions to obtain the maximum SUVs (maxSUVs). Results: Of the 33 patients, 22 had abnormal F-18 FDG uptake in the visual assessment. There was no significant difference in the frequency of abnormal F-18 FDG uptake between group 1 and group 2 (p=0.17), although the frequency of group 1 tended to be higher than group 2 (15/19 (78.9%) in group 1, 7/14 (50.0%) in group 2). However, group 1 had a higher maxSUV than group 2 (p<0.01, group 1: $2.9{\pm}1.4$, group 2: $1.5{\pm}0.6$). There was no significant difference in the frequency of abnormal F-18 FDG uptake and maxSUV among the histology of the lung cancers. Conclusion: The involvement of axial interstitium in the PLC by lung cancer has a higher maxSUV than the involvement of only peripheral interstitium.

Resolution Evaluation of a Pinhole Collimator according to the Aperture Diameter using Micro Deluxe Phantom (Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가)

  • An, Byung Ho;Yeon, Joon Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.3-11
    • /
    • 2015
  • Purpose It is hard to obtain high quality images of knee and T.M joint because of a lot of soft tissues in the knee and T.M joint area. Most conventional system for high resolution scintigraphy was used by 4 mm aperture pinhole collimator. Performance comparison of high-resolution pinhole SPECT for Micro deluxe phantom using conventional system. the aim of this study is to evaluate performance of each aperture according to the diameter size and the usefulness of 24-hour delayed bone scintigraphy. Materials and Methods In this study 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture and Micro Deluxe phantom was used for performance comparison of conventional SPECT system, Projection data were obtained with 9 degree increment per 30 second. Transverse images were reconstructed using dedicated OSEM algorithm with recovery of detector blurring. $^{99m}Tc-HDP$ source was used for 24-hour delayed bone scintigraphy. Results The knee joint images obtained with 24-hour delay were improved more than those obtained with 3-hour delay in our study. The 6 mm and 8 mm pinhole collimators FWHM have improved by 28% SNR and Uniformity have improved by 35%, Contrast has improved by 7% in 24-hour delayed knee joint image. While in 24-hour delayed T.M joint image of the 6 mm and 8 mm pinhole collimators FWHM have decreased by 60% SNR has decreased by 20% and Uniformity has decreased by 25%, Contrast has decreased significantly. Conclusion Pinhole collimators with 6 mm and 8 mm diameter could offer a superior performance for 24-hour delayed bone scintigraphy. The use of 24-hour delayed image provides additional benefits for pinhole scintigraphy of knee joint. Therefore, we expect that it is useful for precise diagnosis of knee joint and it is applicable to others joint imaging.

  • PDF

Classification of submitted KSNMT dissertation (대한핵의학기술학회 투고 논문 분류)

  • Han, Dong-Chan;Lee, Hyuk;Hong, Gun-Chul;Ahn, Byeong-Ho;Choi, Seong-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.65-69
    • /
    • 2017
  • Purpose KSNMT(Korea Society of Nuclear Medicine Technology) stepping first step in 1997, has published first journal related with nuclear medicine technology in 1985. With classifying In Vivo Session Dissertation reported in the entire journal, trend of the Dissertation will be studied. Materials and Methods Dissertations which published from 1985 to first half of 2016 in the journal are classified with presentation form and with scanner, And all the data is organized with Excel program. Through the data, the number of dissertations published in each year, the number of dissertation published in details, and keyword distributions in each period are analyzed. Results The number of In-vivo section dissertations was 1151 and the number of In-vivo section dissertations that have common subject with In-vitro section was 28. The number of In-vivo section dissertation in 1980s was 46, in 1990s was 149, in 2000 was 467 and from 2010 to the first half of 2016 was 517. The number of dissertation with original articles was 571, with abstract was 529, with symposium was 31, with special lecture was 25, with review was 11, with interesting image was 7, with poster was 3 and with case report was 2. With symposium and special lecture excluded, which count 56, the number of dissertation with PET was 319, with Planar was 302, with SPECT was 172, with radiopharmaceutical was 113, with guard and safety management 103, with BMD was 28, etc. was 86. The number of dissertation about oncology was 201, about scanner was 179, about cardiovascular and circulatory system was 102, about safe environment was 82, about musculoskeletal system was 76, about nervous nuclear medicine was 66, about quality assurance was 61, about genitourinary system was 56, about endocrine system was 49, about digestive system was 44, about Therapy, about industrial safety was 24, about molecular imaging was 15, infection and inflammation was 9, about respiratory system was 8 and etc. was 108. The mostly used keyword through 1999 to 2005 was PET and through 2006 to 2016 was PET/CT. Conclusion To encourage various dissertations to be submitted, Korea Society of Nuclear Medicine should analyze date about not only about dissertations that are already published, but also about various research materials. Moreover, Korea Society of Nuclear Medicine also have to provide technical support such as sharing big data from homepage and systematical support to its member to publish dissertation that has high impact factor. It is important each individual researcher to have continuing effort as well as each organization cooperation.

  • PDF

The Study On Quality Control of Magnetic Resonance Imaging System (자기공명영상장치의 정도관리에 관한 연구)

  • Jeong, Cheon-Soo;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.178-186
    • /
    • 2009
  • The quality control is needed to ensure the accuracy of medical information and achieved by evaluating the performance of and maintaining the system and practicing various measurements and evaluations. The Korean Institute for Accreditation of Medical Image, therefore, have held educational program for quality control of special medical equipments. The major of programs participants, however, are radiology specialists with only small number of radiological technologists from some hospitals, furthermore, the follow-up education and the share of information between participants and non-participants are insufficient in general, thus, the knowledge level of radiological technologists, regardless of their participation, is relatively low. This study carried out the questionnaire research for the 500 radiological technologists registered in Korean Society of MRI Technology, on the basis of 2008, and performed analysis for five months from May to Oct., 2008. The questionnaires were delivered by post to each radiological technologists and the response rate was 36%(n=180). The results of this revealed that the 86.7% of respondents felt the necessity of inspection on quality management, while only the 27.8% completed the educational program for manager of special medical equipment. and only the half(53.9%) had the knowledge about inspection on quality management. The completion of educational program had no correlations with sex, age, size of occupying hospital, the number of radiological technologists in occupying site and MRI laboratory, career year of general radiologist and in MRI laboratory, and the presence of biomedical engineering department in occupying hospital. The 78.0% of participants at the educational program for quality management held by the Korean Institute for Accreditation of Medical Image had the knowledge about inspection on quality management(p<.05) whereas the 43.9% of the hospitals held such program and the 54.4% of radiological technologists from those hospitals had related knowledge, which indicated that such programs held by hospitals had not effects on the knowledge level of radiological technologists. This indicates also that the contents, methods, and other conditional factors of educational programs are important for the outcome of them.

The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis (전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구)

  • Hwang, Sung Il;Lee, Hak Jong;Kim, Kil Joong;Chung, Jin-haeng;Jung, Hyun Sook;Jeon, Jong June
    • Ultrasonography
    • /
    • v.32 no.2
    • /
    • pp.132-142
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the correlations of various kinetic parameters derived from the time intensity curve in a xenograft mouse model injected with a prostate cancer model (PC-3 and LNCaP) using an ultrasound contrast agent with histopathologic parameters. Materials and Methods: Twenty nude mice were injected with human prostate cancer cells (15 PC-3 and five LNCaP) on their hind limbs. A bolus of $500{\mu}L$ ($1{\times}10^8$ microbubbles) of second-generation US contrast agent (SonoVue) was injected into the retroorbital vein. The region of interest was drawn over the entire tumor. The time intensity curve was acquired and then fitted to a gamma variate function. The maximal intensity (A), time to peak (Tp), maximal wash-in rate (washin), washout rate (washout), area under the curve up to 50 sec ($AUC_{50}$), area under the ascending slope ($AUC_{in}$), and area under the descending slope ($AUC_{out}$) were derived from the parameters of the gamma variate fit. Immunohistochemical staining for VEGF and CD31 was performed. Tumor volume, the area percentage of VEGF stained in a field, and the count of CD31 (microvessel density, MVD) positive vessels showed correlation with the parameters from the time intensity curve. Results: No significant differences were observed between the kinetic and histopathological parameters from each group. MVD showed positive correlation with A (r=0.625, p=0.003), washin (r=0.462, p=0.040), $AUC_{50}$ (r=0.604, p=0.005), and $AUC_{out}$ (r=0.587, p=0.007). Positive correlations were also observed between tumor volume and $AUC_{50}$ (r=0.481, p=0.032), washin (r=0.662, p=0.001), and $AUC_{out}$ (r=0.547, p=0.012). Washout showed negative correlations with MVD (r=-0.454, p=0.044) and tumor volume (r=-0.464, p=0.039). The area percentage of VEGF did not show any correlation with calculated data from the curve. Conclusion: MVD showed correlations with several of the kinetic parameters. CEUS has the potential for prediction of tumor vascularity in a prostate cancer animal model.

Age-Based Characteristics of West Syndrome in Patients with Mitochondrial Disease (미토콘드리아 질환에서 웨스트 증후군 환자의 경련 발생 연령에 따른 임상 양상 비교)

  • Choi, Young Ha;Baek, Min-Seong;Na, Ji-Hoon;Kang, Hoon-Chul;Lee, Joon Soo;Kim, Heung Dong;Lee, Young-Mock
    • Journal of the Korean Child Neurology Society
    • /
    • v.26 no.4
    • /
    • pp.197-204
    • /
    • 2018
  • Purpose: West syndrome is a severe form of age-specific epilepsy that typically affects infants younger than 2 years of age with mitochondrial disease. We aimed to examine age-specific characteristics of the syndrome in these patients. Methods: We retrospectively analyzed 54 patients with West syndrome diagnosed with mitochondrial disease between March 2006 and March 2016. We compared treatment strategies and diagnostic and clinical variables between patients with early-onset (<6 months of age) and late-onset (${\geq}6$ months of age) seizures. Results: Seizure was the first symptom in 30 (90.9%) and 13 (65%) patients of the early-onset and late-onset groups, respectively (P=0.046). Delayed development was observed in 3 (9.1%) and 7 (35%) patients of the early-onset and late-onset groups, respectively (P=0.023). Lactate levels were normal in 17 patients (55%) of the early-onset group and 5 (25%) of the late-onset group (P=0.036), while initial brain magnetic resonance imaging (MRI) findings were normal in 23 (67.6%) and 8 (40%) patients of the early-onset and late-onset groups, respectively. Final MRI findings were abnormal in 32 patients (94.1%) of the early-onset group and 18 (90%) of the late-onset group (P=0.036). Although ketogenic diets reduced seizure frequency in both groups, the difference was not significant. Conclusion: There is no significant difference in epilepsy-related variables when patients are divided based on a cut-off age of 6 months. However, differences in the first symptom at onset and MRI findings were observed. Although lactate levels were not of significant diagnostic value in the early-onset group, they may be in the late-onset group.

Automated patient set-up using intensity based image registration in proton therapy (양성자 치료 시 Intensity 기반의 영상 정합을 이용한 환자 자동화 Set up 적용 방법)

  • Jang, Hoon;Kim, Ho Sik;Choe, Seung Oh;Kim, Eun Suk;Jeong, Jong Hyi;Ahn, Sang Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.97-105
    • /
    • 2018
  • Purpose : Proton Therapy using Bragg-peak, because it has distinct characteristics in providing maximum dosage for tumor and minimal dosage for normal tissue, a medical imaging system that can quantify changes in patient position or treatment area is of paramount importance to the treatment of protons. The purpose of this research is to evaluate the usefulness of the algorithm by comparing the image matching through the set-up and in-house code through the existing dips program by producing a Matlab-based in-house registration code to determine the error value between dips and DRR to evaluate the accuracy of the existing treatment. Materials and Methods : Thirteen patients with brain tumors and head and neck cancer who received proton therapy were included in this study and used the DIPS Program System (Version 2.4.3, IBA, Belgium) for image comparison and the Eclipse Proton Planning System (Version 13.7, Varian, USA) for patient treatment planning. For Validation of the Registration method, a test image was artificially rotated and moved to match the existing image, and the initial set up image of DIPS program of existing set up process was image-matched with plan DRR, and the error value was obtained, and the usefulness of the algorithm was evaluated. Results : When the test image was moved 0.5, 1, and 10 cm in the left and right directions, the average error was 0.018 cm. When the test image was rotated counterclockwise by 1 and $10^{\circ}$, the error was $0.0011^{\circ}$. When the initial images of four patients were imaged, the mean error was 0.056, 0.044, and 0.053 cm in the order of x, y, and z, and 0.190 and $0.206^{\circ}$ in the order of rotation and pitch. When the final images of 13 patients were imaged, the mean differences were 0.062, 0.085, and 0.074 cm in the order of x, y, and z, and 0.120 cm as the vector value. Rotation and pitch were 0.171 and $0.174^{\circ}$, respectively. Conclusion : The Matlab-based In-house Registration code produced through this study showed accurate Image matching based on Intensity as well as the simple image as well as anatomical structure. Also, the Set-up error through the DIPS program of the existing treatment method showed a very slight difference, confirming the accuracy of the proton therapy. Future development of additional programs and future Intensity-based Matlab In-house code research will be necessary for future clinical applications.

  • PDF

Effects on the Thermal Change of the Face Follow Electroacupunctyre on Hapkok($LI_4$), Sangan($LI_3$) (合谷($LI_4$), 三間($LI_3$)의 電針刺戟이 顔面部 領域 溫度變化에 미치는 影響)

  • Yun, Jeong-hun;Kim, Jong-Han;Hwang, Chung-yeon;Lim, Kyu-sang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.12 no.2
    • /
    • pp.222-247
    • /
    • 1999
  • The back ground and purpose : The acupuncture of oriental medicine is very important in treatments. Until now it has been researched according to the meridian and qi xue(氣血) phenomenon of oriental medicine's theory. As electroacupuncture is one of acupuncture treatments, it will show more objective index to observe the meridian and qi xue(氣血) phenomenon. And then, I studied the effects on the thermal change of the face following electroacupuncture treatment. Objective and Methods : This study was performed from January 1999 to March 1999 on 10 healthy students. The objective was divided into three groups, those were the control group A(n=10), the group B(n=10) of electroacupuncture on Hapkok($LI_4$), Samgan($LI_3$) and the group C(n=10) of electroacupuncture on Shinmun($H_7$), T' ongni($H_5$). First, in the control group A, we took a picture for 10 men without any stimulation with the Digital Infrared Thermograph Imaging(D.I.T.I.) and did 3min after, 10min after, 15min after, 25min after, 45min after respectively. Second, in the electroacupuncture treatment group B, we took a picture for 10 men without any stimulation, and then treat electroacupuncture on Hapkok($LI_4$), Samgan($LI_3$) and took a picture immediately(3min after), 10min after, 15min after and remove needle and took a picture in the same way respectively. Third, in the electroacupuncture treatment group C, we took a picture for 10 men without any stimulation, and then treat electroacupuncture on Shinmun($H_7$), T'ongni($H_5$) and took a picture in the second way respectively. Results: 1. In healthy men, average skin temperture about Yonghyang($LI_{20}$) area was higher than Soryo($G_{25}$) or Chich'ang($S_4$) area. They were Soryo($G_{25}$) area $31.495{\pm}0.766^{\circ}C$, Rt. Yonghyang($LI_{20}$) area $31.664{\pm}0.936^{\circ}C$, Lt. Yonghyang ($LI_{20}$)area $31.686{\pm}0.767^{\circ}C$, Rt. Chich'ang($S_4$) area $31.226{\pm}0.875^{\circ}$, Lt. Chich'ang ($S_4$) area $31.453{\pm}0.855^{\circ}C$. 2. In the control group A, the skin temperature of Soryo($G_{25}$) showed the increase or decrease in below ${\Delta}0.1^{\circ}C\;except\;0.265{\pm}0.594^{\circ}C$ in 25min, but not significantly. 3. About Soryo($G_{25}$) area, the skin temperature decreased significantly after electroacupuncture immediately. ${\Delta}T $of the group B was $-0.970{\pm}0.87\;1^{\circ}C$, which was larger than one of the group C which was $-0.707{\pm}0.624^{\circ}C$ at 3min. And then ${\Delta}T$ of the group C was increase valuable at 25min, 45min. 4. About Yonghyang($L1_{25}$) area, the left ${\Delta}T$ of the group B showed below $0.2^{\circ}C$ or so in contrast to the right it. In the group C, on the both side showed continous increase of temperature as following times. 5. About Chich'ang($S_4$) area, the skin temperature increased valuable $0.3^{\circ}C$ or so on the both side and later inclined to decrease in the group B but not significantly. In the group C, it increased valuable on the both side. 6. The skin temperature of electroacupuncture treatment group B, C were more increase than the control group A except Lt. Yonghyang($LI_{20}$) area in the group B. The temperature of group C were more increase than the group B wholly. Conclusion : The above results indicate that D.I.T.I. is a useful method to observe and fallow-up the effects and the changes by electroacupuncture stimulation on objective evaluation of phenomenon for the meridian system and character. Thus, continuous thermographic study will be needed for more clinical application such as acupuncture and medicine or laser therapy according to oriental medicine.

  • PDF

Factors Associated with Conversion from Conservative to Surgical Treatment in Single-Level Lumbar Spinal Stenosis Patients (보존적 치료 중인 단분절 요추관 협착증 환자에서 수술적 치료로 전환과 관련된 연관 인자)

  • Ahn, Young-Joon;Im, Se-Hyuk;Park, Byung-Kyu
    • Journal of Korean Society of Spine Surgery
    • /
    • v.25 no.4
    • /
    • pp.160-168
    • /
    • 2018
  • Study Design: Retrospective study of prospectively-collected data. Objectives: To determine the factors associated with conversion from conservative to surgical treatment in single-level lumbar spinal stenosis patients. Summary of Literature Review: Various reports have presented clinical outcomes after the surgical and nonsurgical treatment of spinal stenosis. However, few reports have investigated factors predicting conversion to surgery during the course of conservative treatment. Materials and Methods: We analyzed 40 patients who visited our hospital from May 2010 to May 2015 and were traceable for at least 3 years after being advised to undergo surgery following 3 months of conservative treatment. Of these patients, 20 underwent surgery and 20 did not. We then investigated the factors associated with conversion to surgical treatment. Clinical assessments were conducted using a questionnaire, and the overall area of the spinal canal and the muscle area within the spinal canal were measured using magnetic resonance imaging. Results: The average area of the spinal canal was $81.40{\pm}53.61mm^2$ in the surgical group, compared to $127.75{\pm}82.55mm^2$ in the nonsurgical group (p=0.042). The muscle area in the spinal canal was $5.17{\pm}1.30cm^2$ in the surgical group, whereas it was $6.40{\pm}1.56cm^2$ in the nonsurgical group (p=0.010). The patients in the surgical group were more likely to have experienced repetitive strain and to have frequently visited health clubs (p=0.047, p=0.037, respectively). However, regular stretching was more common in the nonsurgical group (p=0.028). Conclusions: The factors associated with conversion to surgical treatment were a narrow spinal canal, a small muscle area within the spinal canal, visiting health clubs, repetitive sprain, and not stretching. A small muscle area within the spinal canal can be considered as a key factor related to surgical conversion.