• Title/Summary/Keyword: imaging methods

Search Result 4,718, Processing Time 0.031 seconds

Decreased White Matter Structural Connectivity in Psychotropic Drug-Naïve Adolescent Patients with First Onset Major Depressive Disorder (정신과적 투약력이 없는 초발 주요 우울장애 청소년 환아들에서의 백질 구조적 연결성 감소)

  • Suh, Eunsoo;Kim, Jihyun;Suh, Sangil;Park, Soyoung;Lee, Jeonho;Lee, Jongha;Kim, In-Seong;Lee, Moon-Soo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.25 no.2
    • /
    • pp.153-165
    • /
    • 2017
  • Objectives : Recent neuroimaging studies focus on dysfunctions in connectivity between cognitive circuits and emotional circuits: anterior cingulate cortex that connects dorsolateral orbitofrontal cortex and prefrontal cortex to limbic system. Previous studies on pediatric depression using DTI have reported decreased neural connectivity in several brain regions, including the amygdala, anterior cingulate cortex, superior longitudinal fasciculus. We compared the neural connectivity of psychotropic drug naïve adolescent patients with a first onset of major depressive episode with healthy controls using DTI. Methods : Adolescent psychotropic drug naïve patients(n=26, 10 men, 16 women; age range, 13-18 years) who visited the Korea University Guro Hospital and were diagnosed with first onset major depressive disorder were registered. Healthy controls(n=27, 5 males, 22 females; age range, 12-17 years) were recruited. Psychiatric interviews, complete psychometrics including IQ and HAM-D, MRI including diffusion weighted image acquisition were conducted prior to antidepressant administration to the patients. Fractional anisotropy(FA), radial, mean, and axial diffusivity were estimated using DTI. FMRIB Software Library-Tract Based Spatial Statistics was used for statistical analysis. Results : We did not observe any significant difference in whole brain analysis. However, ROI analysis on right superior longitudinal fasciculus resulted in 3 clusters with significant decrease of FA in patients group. Conclusions : The patients with adolescent major depressive disorder showed statistically significant FA decrease in the DTI-based structure compared with healthy control. Therefore we suppose DTI can be used as a bio-marker in psychotropic drug-naïve adolescent patients with first onset major depressive disorder.

Clinical Study of Renal Cystic Diseases in Children (소아의 낭포성 신질환에 대한 임상적 고찰)

  • Kim, Ja Hyung;Kim, You Jeong;Lee, Byeong Seon;Ko, Tae Sung;Park, Young Seo
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.232-239
    • /
    • 2002
  • Purpose : Renal cystic diseases comprise a mixed group of heritable, developmental and acquired disorders. Recently the use of imaging modalities such as ultrasonography and radionuclide scanning has increased the detection rate of renal cystic diseases. We studied to review the clinical features and treatment of renal cystic diseases in children. Methods : This study was performed in 95 children with renal cystic diseases in the Department of Pediatrics, Asan Medical Center from October 1989 to June 2001. Results : In 95 patients, there were 55 cases(58.0%) with multicystic dysplastic kidney(MCDK), 19 cases(20.0%) with simple renal cysts, 13 cases(13.7%) with hereditary polycystic kidney diseases( 7 with autosomal recessive type, 5 with autosomal dominant type, 1 with undetermined), 6 cases(6.3%) with renal cysts in tuberous sclerosis and 1 case(1.0%) with medullary cystic disease. All MCDK patients had no renal dysfunction and hypertension during the follow-up period. Three out of 13 with polycystic kidney diseases had progressed to end-stage renal disease during the follow-up period. One case with a simple cyst underwent laparoscopic malsupialization for decompression. Conclusion : Renal cystic diseases have diverse clinicopathologic features and variable prognosis. We emphasize that routine follow-up should be performed to prevent and to detect early treatable complication in renal cystic diseases. Therefore, their natural history and treatment need further investigation and long term follow-up is required.

Evaluate the implementation of Volumetric Modulated Arc Therapy QA in the radiation therapy treatment according to Various factors by using the Portal Dosimetry (용적변조회전 방사선치료에서 Portal Dosimetry를 이용한 선량평가의 재현성 분석)

  • Kim, Se Hyeon;Bae, Sun Myung;Seo, Dong Rin;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.167-174
    • /
    • 2015
  • Purpose : The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Materials and Methods : Test was used for TrueBeam STx$^{TM}$ (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). Results : The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Conclusion : Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  • PDF

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

The results of arthroscopic repair according to the delamination of rotator cuff (회전근 개 판분리 파열에 따른 관절경하 회전근 개 봉합술의 결과)

  • Ku, Jung Hoei;Cho, Hyung Lae;Park, Man Jun;Kim, Jeong Cheol
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • Purpose: We evaluated the clinical outcome after arthroscopic repair in full thickness rotator cuff tears with and without delamination. Materials and Methods: From March 2006 to October 2008, we included 48 consecutive shoulders (31 males, 17 females; mean age 57.6 years; 45~68) who had arthroscopic double row repair for fullthickness tears of the rotator cuff. Mean rotator cuff tear size was 2.8 cm (range: 1.2~3.6) and the techniques of tendon-to-bone fixation varied according to the presence of delamination; separate row fixations of bursal and articular layer were used in delaminated tear. The mean follow-up was 26 months (range: 18~33) and functional and structural results were evaluated by American Shoulder and Elbow Surgeons (ASES), University of California at Los Angeles (UCLA) scale, isokinetic strength testing and magnetic resonance imaging (MRI) obtained mean 8 months (range:6~13) postoperatively. The patterns of delamination, age, sex, symptom duration, size of tear, satisfaction rate, retear rate ware compared and significance was set at p values < 0.05. Results: Postoperative functional shoulder score improved significantly in 44 shoulders (91.7%). Delamination was observed in 15 shoulders (31%) and it extended proximally and posteriorly in the majority of shoulders, and the articular layer was thicker (8/15, 53%) and more retracted (9/15, 60%) compared with the superficial bursal layer. Final follow up functional shoulder scores showed no differences between non-delaminated and delaminated tears and the presence of delamination had no correlations with sex, symptom duration, tear size and satisfaction rate, however, older age had more delaminated tears (p=0.041). Follow up MRI in 29 shoulders revealed that fourteen (48%) shoulders had complete healing; nine (31%), partial healing; six (21%), complete retear but the half of the retear group showed favorable clinical results. 79% (15/19) in non-delaminated tear and 80% (8/10) in delaminated tear were judged as healed tendon on MRI and double-layer double row repairs in delaminated tears resulted in nearly same rate of structural integrity of single-layer double row repairs (p=0.165). Conclusion: The incidence of delamination in our series was 31% and older age had more delaminated tears. Sex, symptom duration, preoperative size of the tear, functional results and satisfaction rate had no significant correlations with the presence of delamination. Nearly the same postoperative structural integrity was noted in both delaminated and non-delaminated tears.

  • PDF

Use of Numerical Simulation for Water Area Observation by Microwave Radar (마이크로웨이브 레이더를 이용한 수역관측에 있어서의 수치 시뮬레이션 이용)

  • Yoshida, Takero;Rheem, Chang-Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.3
    • /
    • pp.208-218
    • /
    • 2012
  • Numerical simulation technique has been developed to calculate microwave backscattering from water surface. The simulation plays a role of a substitute for experiments. Validation of the simulation was shown by comparing with experimental results. Water area observations by microwave radar have been simulated to evaluate algorithms and systems. Furthermore, the simulation can be used to understand microwave scattering mechanism on the water surface. The simulation has applied to the various methods for water area observations, and the utilizations of the simulation are introduced in this paper. In the case of fixed radar, we show following examples, 1. Radar image with a pulse Doppler radar, 2. Effect of microwave irradiation width and 3. River observation (Water level observation). In addition, another application (4.Synthetic aperture radar image) is also described. The details of the applications are as follows. 1. Radar image with a pulse Doppler radar: A new system for the sea surface observation is suggested by the simulation. A pulse Doppler radar is assumed to obtain radar images that display amplitude and frequency modulation of backscattered microwaves. The simulation results show that the radar images of the frequency modulation is useful to measure sea surface waves. 2. Effect of microwave irradiation width: It is reported (Rheem[2008]) that microwave irradiation width on the sea surface affects Doppler spectra measured by a CW (Continuous wave) Doppler radar. Therefore the relation between the microwave irradiation width and the Doppler spectra is evaluated numerically. We have shown the suitable condition for wave height estimation by a Doppler radar. 3. River observation (Water level observation): We have also evaluated algorithms to estimate water current and water level of river. The same algorithms to estimate sea surface current and sea surface level are applied to the river observation. The simulation is conducted to confirm the accuracy of the river observation by using a pulse Doppler radar. 4. Synthetic aperture radar (SAR) image: SAR images are helpful to observe the global sea surface. However, imaging mechanisms are complicated and validation of analytical algorithms by SAR images is quite difficult. In order to deal with the problems, SAR images in oceanic scenes are simulated.

Assessment of the Breast-Firmming Effects of a Cosmetic Preparation with Moir$\acute{e}$ Tophography in Combination with 2D and 3D Digital Image Analyses (2D 및 3D 디지털 이미지 분석과 함께 Moir$\acute{e}$ Tophography 분석을 이용한 화장품의 가슴 탄력개선 효과 평가)

  • Seo, Young Kyoung;Yoo, Mi Ae;Ryu, Ja Hyun;Kim, So Jeong;Cho, Seong A;Nam, Gae Won;Cho, Jun-Cheol;Boo, Yong Chool;Koh, Jae-Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.4
    • /
    • pp.289-296
    • /
    • 2012
  • Cosmetic products which might augment the breast have attracted an attention and objective methods for the evaluation of such products are in high demand. This study was conducted to establish a method for assessing the breast-firmming effects of cosmetics. This study included a total of 30 healthy Korean females aged 20-50 years. A cosmetic product was applied by massaging it onto the breast twice a day for 8 weeks. Measurement of breast girth with a tape ruler, 2D and 3D digital image analyses, and Moir$\acute{e}$ topographic analysis were performed before and following the treatment. The application of a cosmetic onto the breast significantly increased breast girth at 2, 4 and 8 weeks without a significant change in underbreast girth, implicating the breast might be augmented. The 2D image analysis indicated that the arc length of the breast which represents the surface distance from the nipple to the periphery of the under-breast was significantly increased at 2, 4 and 8 weeks. The height of the breast which represents the perpendicular distance from the nipple to the periphery of the under-breast was also increased significantly at 4 and 8 weeks. The 3D image analysis of body surface also demonstrated a significant increase of breast volume at 2, 4 and 8 weeks. Moir$\acute{e}$ topographic analysis indicated that breast sagging was significantly reduced at 2, 4 and 8 weeks. The results of this study suggest that Moir$\acute{e}$ topography in combination with 2D and 3D digital image analyses may be useful for evaluating the breast-augmenting effects of cosmetics.

Retrospective Evaluation of Discrepancies between Radiological and Pathological Size of Hepatocellular Carcinoma Masses

  • Tian, Fei;Wu, Jian-Xiong;Rong, Wei-Qi;Wang, Li-Ming;Wu, Fan;Yu, Wei-Bo;An, Song-Lin;Liu, Fa-Qiang;Feng, Li;Liu, Yun-He
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9487-9494
    • /
    • 2014
  • Background: The size of a hepatic neoplasm is critical for staging, prognosis and selection of appropriate treatment. Our study aimed to compare the radiological size of solid hepatocellular carcinoma (HCC) masses on magnetic resonance imaging (MRI) with the pathological size in a Chinese population, and to elucidate discrepancies. Materials and Methods: A total of 178 consecutive patients diagnosed with HCC who underwent curative hepatic resection after enhanced MRI between July 2010 and October 2013 were retrospectively identified and analyzed. Pathological data of the whole removed tumors wereassessed and differences between radiological and pathological tumor size were identified. All patients were restaged using a modified Tumor-Node-Metastasis (TNM) staging system postoperatively according to the maximum diameter alteration. The lesions were classified as hypo-staged, iso-staged or hyper-staged for qualitative assessment. In the quantitative analysis, the relative pre and postoperative tumor size contrast ratio ($%{\Delta}size$) was also computed according to size intervals. In addition, the relationship between radiological and pathological tumor diameter variation and histologic grade was analyzed. Results: Pathological examination showed 85 (47.8%) patients were overestimated, 82 (46.1%) patients underestimated, while accurate measurement by MRI was found in 11 (6.2%) patients. Among the total subjects, 14 (7.9%) patients were hypo-staged and 15 (8.4%) were hyper-staged post-operatively. Accuracy of MRI for calculation and characterized staging was related to the lesion size, ranging from 83.1% to 87.4% (<2cm to ${\geq}5cm$, p=0.328) and from 62.5% to 89.1% (cT1 to cT4, p=0.006), respectively. Overall, MRI misjudged pathological size by 6.0 mm (p=0.588 ), and the greatest difference was observed in tumors <2cm (3.6 mm, $%{\Delta}size=16.9%$, p=0.028). No statistically significant difference was observed for moderately differentiated HCC (5.5mm, p=0.781). However, for well differentiated and poorly differentiated cases, radiographic tumor maximum diameter was significantly larger than the pathological maximum diameter by 3.15 mm and underestimated by 4.51 mm, respectively (p=0.034 and 0.020). Conclusions: A preoperative HCC tumor size measurement using MRI can provide relatively acceptable accuracy but may give rise to discrepancy in tumors in a certain size range or histologic grade. In pathological well differentiated subjects, the pathological tumor size was significantly overestimated, but underestimated in poorly differentiated HCC. The difference between radiological and pathological tumor size was greatest for tumors <2 cm. For some HCC patients, the size difference may have implications for the decision of resection, transplantation, ablation, or arterially directed therapy, and should be considered in staging or selecting the appropriate treatment tactics.

Cerebral Activity by Motor Task in Welders Exposed to Manganese through fMRI (fMRI를 이용한 망간 노출 용접공의 운동수행에 따른 뇌 활성도 평가)

  • Choi, Jae-Ho;Jang, Bong-Ki;Lee, Jong-Wha;Hong, Eun-Ju;Lee, Myeong-Ju;Ji, Dong-Ha
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.102-112
    • /
    • 2011
  • Objectives: The purpose of this study is to analyze the effects of chronic exposure by welders to manganese (Mn) through an analysis of the degree of brain activity in different activities such as cognition and motor activities using the neuroimaging technique of functional magnetic resonance imaging (fMRI). The neurotoxic effect that Mn has on the brain was examined as well as changes in the neuro-network in motor areas, and the usefulness of fMRI was evaluated as a tool to determine changes in brain function from occupational exposure to Mn. Methods: A survey was carried out from July 2010 to October 2010 targeting by means of a questionnaire 160 workers from the shipbuilding and other manufacturing industries. Among them, 14 welders with more than ten years of job-related exposure to Mn were recruited on a voluntary basis as an exposure group, and 13 workers from other manufacturing industries with corresponding gender and age were recruited as a control group. A questionnaire survey, a blood test, and an fMRI test were carried out with the study group as target. Results: Of 27 fMRI targets, blood Mn concentration of the exposure group was significantly higher than that of the control group (p<0.001), and Pallidal Index (PI) of the welder group was also significantly higher than that of the control group (p<0.001). As a result of the survey, the score of the exposure group in self-awareness of abnormal nerve symptoms and abnormal musculoskeletal symptoms was higher than those of the control group, and there was a significant difference between the two groups (p<0.05, respectively). In the correlation between PI and the results of blood tests, the correlation coefficient with blood Mn concentration was 0.893, revealing a significant amount of correlation (p<0.001). As for brain activity area within the control group, the right and the left areas of the superior frontal cortex showed significant activity, and the right area of superior parietal cortex, the left area of occipital cortex and cerebellum showed significant activity. Unlike the control group, the exposure group showed significant activity selectively on the right area of premotor cortex, at the center of supplementary motor area, and on the left side of superior temporal cortex. In the comparison of brain activity areas between the two groups, the exposure group showed a significantly higher activation state than did the control group in such areas as the right and the left superior parietal cortex, superior temporal cortex, and cerebellum including superior frontal cortex and the right area of premotor cortex. However, in nowhere did the control group show a more activated area than did the exposure group. Conclusions: Chronic exposure to Mn increased brain activity during implementation of hand motor tasks. In an identical task, activation increased in the premotor cortex, superior temporal cortex, and supplementary motor area. It was also discovered that brain activity increase in the frontal area and occipital area was more pronounced in the exposure group than in the control group. This result suggests that chronic exposure to Mn in the work environment affects brain activation neuro-networks.

Clinical Significance of Tumor Markers in Gastric Cancer Patients after Curative Resection (근치적 절제술을 시행한 위암 환자에서 종양 표지자의 임상적 의미)

  • Kim, Sa-Young;Ha, Tae-Kyung;Kwon, Sung-Joon
    • Journal of Gastric Cancer
    • /
    • v.9 no.3
    • /
    • pp.136-142
    • /
    • 2009
  • Purpose: This clinical study was conducted to evaluate the predictive value of tumor markers for recurrence and the clinical significance of false positive findings after curative gastrectomy in patients with gastric cancer. Materials and Methods: Two hundred ninety patients with gastric cancer who underwent gastrectomy with curative intent were evaluated retrospectively. We analyzed the correlations between changes in tumor markers (CEA, CA 19-9, AFP, and CA-125) and clinicopathologic data, and basis for changes in tumor markers without recurrence during the follow-up period. Results: The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of tumor markers for recurrence were 75.0%, 64.6%, 23.1%, 94.8%, and 65.9% respectively. Among 36 patients with recurrences, 10 patients (27.8%) had elevated tumor markers prior to positive findings on imaging studies, while 13 patients (36.1%) had concomitant elevation in tumor markers. At least 1 of the 4 tumor markers increased in 90 of 290 patients during the follow-up period; however, there was no evidence of tumor recurrence. Twenty patients had persistently elevated tumor markers, while the tumor marker levels in 70 patients returned to normal level within $9.08\pm7.2$ months. The patients with pulmonary disease, hepatobiliary disease, diabetes, hypertension, or herbal medication users had elevated tumor markers more frequently than patients without disease (P<0.001). Conclusion: Although detecting recurrence of gastric cancer with tumor markers may be useful, false positive findings of tumor markers are common, so surgeons should consider other chronic benign diseases and medical conditions when tumor markers increase without evidence of recurrence.

  • PDF