• Title/Summary/Keyword: image magnetic

Search Result 1,147, Processing Time 0.028 seconds

Susceptibility Weighted Image for Stem Cell Tracking in Rat Photothrombotic Infarction (흰쥐 광 혈전 뇌경색 모델에서 줄기세포 추적을 위한 자화강조영상)

  • Ha, Bon-Chul;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.249-256
    • /
    • 2010
  • To the detect of SPIO-labelled hMSC, in vitro study on various cell concentration and in vivo molecular magnetic resonance imaging(MRI) technique using T2, $T2^*$ and SWI are compared with pathology. Cell concentration was $1.56{\times}10^4$, $3.13{\times}10^4$, $6.25{\times}10^4$, $1.25{\times}10^5$, $2.5{\times}10^5$, $5{\times}10^5\;cells/m{\ell}$ and for control $5{\times}10^5\cells/m{\ell}$. MRI technique using T2, $T^2$ and SWI. Photothrombotic infarction was located 2.5mm from bregma right, posterior. Cell injected through the tail vein of rat for 8 rats. MRI performed pre injection and post injection of 1, 3, 7 and 14days and sacrifice for pathology. MRI analysed on quantitatively. In vitro result, SWI was highest CNR as compared with $T2^*WI$, T2WI and $2.5{\times}10^5\;cells/m{\ell}$ cell concentration. In vivo result among the T2WI, $T2^WI$, SWI, T2WI is highest CNR between normal and infarction. CNR in normal-SPIO and infarction-SPIO is high score in SWI. Therefore, T2WI is good distinguish between normal and infarction, SWI are well detect SPIO-labelled hMSC from normal and infarction. Nowaday, SWI are mostly used on hemorrhage, calcification etc. in clinically, but for the future, stem cell therapy is commonly application at all disease which is good observing tool for SPIO-labelled stem cells.

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

Early and Midterm Results of the Extracardiac Fontan Operation and the Change of Internal Diameter of the Conduit (심외도관 폰탄수술후 중단기 성적 및 심외도관의 내경의 변화)

  • 성시찬;김시호
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.177-181
    • /
    • 2002
  • Background: Follow-up studies have shown that although outcomes have improved substantially over time, results of the Fontan operation and its modifications remain suboptimal. In this study, we reviewed our experience with the extracardiac conduit Fontan operation, with a focus early and midterm change of internal diameter of PTFE conduit. Material and Method: Between April 1997 and July 2000 were reviewed. Twelve patients (M:6, F:6, mean age 42.04 $\pm$ 12.43months, mean body weight 13.80$\pm$ 1.94kg) underwent extracardiac conduit Fontan operation with expanded PTFE graft. Mean cardiopulmonary bypass time was 109.7$\pm$26.99minute and mean operation time was 455$\pm$89.51minute. Intraoperative fenestration was performed in 10 patients. The aortic cross clamping was not performed in all patients. Result: There was no early deaths and no postoperative dysrhythmia. Postoperative protein losing enteropathy and prolonged pleural effusion occurred in 1(8.3%) and 4 patients(33.3%). Conduit patency was evaluated by magnetic resonance imaging studies. A 9.84$\pm$3.84% mean reduction in conduit internal diameter and there was no statistical correlation between the change of internal diameter of conduit and the postoperative duration after partial correlation analysis(r=0.019, p=0.955). Conclusion: These results demonstrate that the extracardiac conduit Fontan operation provies good early and midterm results and may reduce the prevalence of late arrhythmia. And there is no correlation between the change of internal diameter of conduit and the postoperative duration after extracardiac conduit Fontan operation with the expanded PTFE graft conduit.

Brain Activation Pattern and Functional Connectivity during Convergence Thinking and Chemistry Problem Solving (융합 사고와 화학문제풀이 과정에서의 두뇌 활성 양상과 기능적 연결성)

  • Kwon, Seung-Hyuk;Oh, Jae-Young;Lee, Young-Ji;Eom, Jeung-Tae;Kwon, Yong-Ju
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.3
    • /
    • pp.203-214
    • /
    • 2016
  • The purpose of this study was to investigate brain activation pattern and functional connectivity during convergence thinking based creative problem solving and chemistry problem solving to identify characteristic convergence thinking that is backbone of creative problem solving using functional magnetic resonance imaging(fMRI). A fMRI paradaigm inducing convergence thinking and chemistry problem solving was developed and adjusted on 17 highschool students, and brain activation image during task was analyzed. According to the results, superior frontal gyrus, middle frontal gyrus, inferior frontal gyrus, medial frontal gyrus, cingulate gyrus, precuneus and caudate nucleus body in left hemisphere and cuneus and caudate nucleus body in right hemisphere were significantly activated during convergence thinking. The other hand, middle frontal gyrus, medial frontal gyrus and caudate nucleus in left hemisphere and middle frontal gyrus, lingual gyrus, caudate nucleus, thalamus and culmen of cerebellum in right hemisphere were significantly activated during chemistry problem solving. As results of analysis functional connectivity, all of areas activated during convergence thinking were functionaly connected, whereas scanty connectivity of chemistry problem solving between right middle frontal gyrus, bilateral nucleus caudate tail and culmen. The results show that logical thinking, working memory, planning, imaging, languge based thinking and learning motivation were induced during convergence thinking and these functions and regions were synchronized intimately. Whereas, logical thinking and inducing learning motivation functioning during chemistry problem solving were not synchronized. These results provide concrete information about convergence thinking.

Radiographic, MRI and Histopathologic Assessment to Standardize Canine Spinal Cord Injury Model (척수손상 모델 견 표준화를 위한 방사선, 자기공명영상 및 조직 병리 평가)

  • Seong, Yun-Sang;Yun, Sung-Ho;Park, Jai-Soon;Kim, Hee-Kyung;Chang, Yong-Min;Ku, Sae-Kwang;Park, Hyun-Jeong;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.546-552
    • /
    • 2010
  • Previous studies could not offer available guideline to decide size of balloon and grade of injury before induction of spinal cord injury (SCI) because grade of SCI was assessed after inserting a catheter and each experimental animal were different in body size and weight as well as in species. This study was performed to provide guideline for standardized SCI model. Eight healthy adult beagle dogs that had 8 mm of spinal canal height were assigned to four groups according to the diameter of balloon and compression time: 4 mm/3hrs, 4 mm/6hrs, 4 mm/12hrs and 6 mm/3hrs group. Radiography was performed to standardize between experimental animal and balloon before selecting balloon diameter to induce SCI. Behaviors outcomes, somatosensory evoked potentials (SEPs), magnetic resonance imaging (MRI) and histopathological examination were evaluated. Behaviors outcomes and SEPs were not available to assess grade of SCI and those only indicate SCI. The damaged area was revealed clear hyperintensity on STIR image and T2WI after induction of SCI. The hyperintense area on MRI was cranially and caudally expanded with increasing of the diameter of balloon or the compression time. Well corresponded to expanding of hyperintense area on MRI, the damaged region and the numbers of caspase-3 and PARP immunoreactive cells were increased on histopathological findings. Therefore, these results will be considered fundamental data to induce standardized SCI model in experimental animal that has various weight and size.

Multi-purpose Geophysical Measurements System Using PXI (PXI를 이용한 다목적 물리탐사 측정 시스템)

  • Choi Seong-Jun;Kim Jung-Ho;Sung Nak-Hun;Jeong Ji-Min
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.3
    • /
    • pp.224-231
    • /
    • 2005
  • In geophysical field surveys, commercial equipments often fail to resolve the subsurface target or even sometimes fail to be applied because they do not fit to the various field situations or the physical properties of the medium or target. We developed a geophysical measurement system, which can be easily adapted for the various field situations and targets. The system based on PXI with A/D converter and some stand alone equipment such as Network Analyzer was applied to borehole radar survey, borehole sonic measurement and electromagnetic noise measurement. The system for borehole radar survey consists of PXI, Network Analyzer, dipole antennas, GPIB interface is used for PXI to control Network Analyzer. The system for borehole sonic measurement consists of PXI, 24 Bit A/D converter, high voltage pulse generator, transmitting and receiving piezoelectric sensors. The electromagnetic noise measurement system consists of PXI, 24 Bit A/D converter, 2 horizontal component electric field sensors and 2 horizontal and 1 vertical component magnetic filed sensors. The borehole radar system has been successfully applied to detect the width of the artificial tunnel through which the borehole pass and to image buried steel pipe, while the commercial borehole radar equipment failed. The borehole sonic system was tested to detect the width of artificial tunnel and showed a reasonable result. The characteristic of electromagnetic noise was grasped at an urban area with the data from the electromagnetic noise measurement system. The system is also applied to characterize the signal distortion by induction between the electric cables in resistivity survey. The system can be applied various geophysical problems with a simple modification of the system and sensors.

Development of Rabbit Brain Tumor Model Using VX2 Cells and Verification with the MRI in Neuroradiologic Research (Neuroradiology 연구를 위한 VX2 세포를 이용한 토끼 뇌종양 모델 제작과 MRI를 이용한 검증)

  • Yong-Woo Kim;Seon Hee Choi;Hak Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.441-453
    • /
    • 2023
  • Purpose To evaluate the development, location, and volume of a VX2 carcinoma using four inoculation methods in a rabbit brain. Materials and Methods Inoculation of a VX2 cell suspension was performed 1) on the appointed day, 2) seven days after storing a VX2 carcinoma in a freezer or 3) seven days after storing a VX2 carcinoma in a deep freezer after sacrificing the donor rabbits. 4) Without sacrificing the rabbits, the VX2 cell suspension was obtained using a gun biopsy, inoculation was performed on the appointed day. MR imaging was performed 10 days after inoculation. Brain tissues were obtained the day after. The development, location, and volume of the tumor were evaluated. Results Seventeen of the 18 rabbits inoculated on the appointed day developed tumors (average tumor volume, 106.32 mm3). One of five inoculated seven days after storing the VX2 tumor in the freezer, and three of five inoculated seven days after storing the VX2 tumor in the deep freezer developed tumors. Inoculation with a VX2 cell suspension obtained with a gun biopsy from five rabbits revealed development of tumors in only two rabbits. The tumors mostly developed in the superficial cortex. Conclusion TVX2 rabbit brain tumor model is easy to develop and revealed variable reproducibility. This model can be applicable in radiologic imaging, treatment planning, interventional treatment and drug delivery research. VX2 cell can be successfully innoculated into the brain using variable methods under researcher's variable conditions.