• 제목/요약/키워드: image evaluation

검색결과 3,777건 처리시간 0.028초

내장신경차단에 관한 임상적 연구 (A Clinical Evaluation of Splanchnic Nerve Block)

  • 김수연;오흥근;윤덕미;신양식;이윤우;김종래
    • The Korean Journal of Pain
    • /
    • 제1권1호
    • /
    • pp.34-46
    • /
    • 1988
  • Intractable pain from advanced carcinoma of the upper abdomen is difficult to manage. One method used to control pain associated with these malignancies is to block off the splanchnic nerve. In 1919 Kappis described a technique by which the splanchnic nerve of the upper abdomen could be anesthetized, using a percutaneous injection. This method has been used for the relief of upper abdominal pain due to hematoma and cancer of the pancreas, stomach, gall bladder, bile duct, and colon. During the Period from November 1968 to January 1986, this method was used in 208 cases of malignancy at Severance Hospital and clinically evaluated. Patients were retroactively grouped according to the stage of development of technique used. Twelve patients who received the treatment in the period from November 1968 to March 1977 were designate4i as group 1, 26 patients from April 1977 to April 1979 as group 2, and 170 from May 1979 to January 1986 as group 3. The results are as follows: 1) The number of patients receiving splanchnic nerve block has been increasing since 1977. 2) A total of 208 patients, including 133 males and 75 females, ranging in age from 18 to 84 and averaging 51. 3) The causes of pain were stomach cancer 90, pancreatic cancer 69, and miscellaneous cancer 49 cases respectively. 4) There were 57.7% who had surgery. and 3.7% of whom had chemotherapy before the splanchnic nerve block was done. 5) These blocks were carried out with the patient in the prone position as described by Dr. Moore. For group 2 and 3, C-arm image intensifier was used. In group 1, a 22 gauze loom long needle was inserted at the lower border of the 12th rib on each aide about 7\;cm from the midline. The average distance from the midline was $6.60{\pm}0.61\;cm$ on the left side and $6.60{\pm}0.83\;cm$ on the right side in group 2, and $5.46{\pm}0.76\;cm$ on the left side and $5.49{\pm}0.69\;cm$ on the right side in group 3. The average depth to which the needle was inserted was $8.60{\pm}0.52\;cm$ on the left side and $8.74{\pm}0.60\;cm$ on the right side in group 2, and $8.96{\pm}0.63\;cm$ on the left side and $9.18{\pm}0.57\;cm$ on the right side in group 3. 6) The points of the inserted needles were positioned in the upper quarter anteriorly, 51.8% on the left side and 54.4% n the right side of the L1 vertebra by lateral roentgenogram in group 3. The inserted needle points were located in the upper and anterolateral part, of the L1 vertebra 68.5% on the left side and 60.6won the right side, on the anteroposterior rentgenogram in group 3. The needle tip was not advanced beyond the anterior margin of the vertebral body. 7) In some case of group 3, contrast media was injected before the block was done. It shows, the spread upward along the anterior mal gin of the vertebral body. 8) The concentration and the average amount of drug used in each group was as follows: In group 1, $39.17{\pm}6.69\;ml$ of 0.5% -l% lidocaine or 0.25% bupivacaine were injected for the test block and one to three days after the test block $40.00{\pm}4.26\;ml$ of 50% alcohol was injected for the semipermanent block. In group 2, $13.75{\pm}4.88\;ml$ of 1% lidocaine were used as the test block and followed by $46.17{\pm}4.37\;ml$ of 50% alcohol was injected as the semipermanent block. In group 3, $15.63{\pm}1.19\;ml$ of 1% lidocaine for test block followed by $15.62{\pm}1.20\;ml$ of pure alcohol and $16.05{\pm}2.58\;ml$ of 50% alcohol for semipermanent block were injected. 9) The result of the test block was satisfactory in all cases. However the semipermanent block was 83.3 percent of the patients in group 1 who received relief from pain for at least 2 weeks after the block, 73.1% in group 2, and 91.8% in group 3. In these unsuccessful cases, 2 cases in group 1 were controlled by narcotics but 7 cases in group 2 and 14 cases in group 3 received the same splanchnic nerve block 1 or 2 times again within 2 weeks. But, in some cases it was 3 to i months before the 2nd block and in 1 cases even 7 years. 10) The most common complications of splanchnic nerve block were hypotensino(25.5%) occasional flushing of the face, nausea, vomiting, and chest discomfort. 11) For the patients in group 3, the supplemental block most commonly used was a continuous epidural block; it was used as a diagnostic block and to afford relief from pain before the splanchnic nerve block was done. 12) The interval between the receiving of the alcohol block and discharge was from 5 to 8 days in 61 cases(31.1%) and from 1 to 2 days in 48 cases(24.5%). From the above results, it can be concluded that the splanchnic nerve block done in the prone position with pure and 50% alcohol immediately after an effective test block with 1% lidocaine under C-arm fluoroscopic control is satisfactory and reliable. How to minimize the repeat block is still a problem to be solved.

  • PDF

다중표적 뼈 전이암의 하이브리드 세기변조(modified hybrid-VMAT) 방사선치료계획 유용성 평가 (Evaluation of the Modified Hybrid-VMAT for multiple bone metastatic cancer)

  • 정일훈;조윤진;장원석;김세준;하진숙;전미진;정인호;김종대;신동봉;이익재
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.161-167
    • /
    • 2018
  • 목 적 : 동일 선상축(co-axial image)의 다발성 뼈 전이암에 대한 하이브리드 세기변조(modified hybrid-VMAT) 계획의 유용성을 평가하고자 한다. 대상 및 방법 : 동일 선상축의 다발성 뼈 전이암환자 총 5명을 대상으로 치료계획시스템(Ray station, 5.0.2.35, Sweden)을 이용하여 치료계획을 수립하였다. 치료계획용적(planning target volume, PTV) 처방 선량은 30 Gy로 설정하여 총 3가지 치료계획: 용적변조회전치료계획(volumetric modulated arc therapy, VMAT); 배경방사선(background)을 고려하지 않은 하이브리드 용적변조회전치료계획(hybrid VMAT, VMAT(h)); 배경방사선을 고려한 하이브리드 용적변조회전치료계획(modified hybrid VMAT, VMAT(mh))을 비교하였다. 선량용적히스토그램(dose volume histogram, DVH)을 이용하여 PTV의 maximum dose($D_{max}$), mean dose($D_{mean}$), 처방선량지수(conformity index, CI), 선량균질지수(homogeneity Index, HI) 및 손상위험장기(organ at risk, OAR)의 선량을 분석하였다. 또한 monitor unit(MU)와 치료시간(beam on time)을 분석하였다. 결 과 : VMAT, VMAT(h)과 VMAT(mh)의 PTV $D_{max}$는 3188.33 cGy, 3526 cGy, 3285.67 cGy이고, $D_{mean}$은 3081 cGy, 3252 cGy, 3094 cGy이고, CI는 $1.35{\pm}0.19$, $1.43{\pm}0.12$, $1.30{\pm}0.06$이고, HI는 $1.06{\pm}0.01$, $1.14{\pm}0.06$, $1.09{\pm}0.02$로 평가되었다. VMAT(h)과 VMAT(mh)의 OAR은 3 % 증가와 18 % 감소하는 것으로 평가되었다. 추가적으로 평균 MU는 904.90, 911.73, 1202.13 그리고 평균 Beam on time은 $128.67{\pm}10.97$초, $167.33{\pm}7.57$초, $190.33{\pm}4.51$초 소요되었다. 결 론 : 다중표적 치료 시에는 modified Hybrid-VMAT를 적용하면 선량의 겹침이 보정되어 과선량(over dose) 조사되는 것을 방지하는 다중표적을 치료할 수 있다. 그리고 PTV의 선량포함을 만족하면서 주위의 정상장기를 더 효과적으로 보호할 수 있는 치료계획이 가능하다. 또한 modified Hybrid-VMAT의 임상적 효능을 확인하기 위해 많은 수의 환자를 대상으로 한 장기 추적 관찰이 필요하다.

  • PDF

정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가 (Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT)

  • 안민우;강효석;최병준;박상준;정다이;이건호;이두상;전명수
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.201-208
    • /
    • 2018
  • 목 적 : 본 연구에서는 정위적체부방사선치료시 ExacTrac과 CBCT를 단계적으로 적용한 Combine IGRT를 사용하여 Set-up 오차를 비교 및 분석하여 Combine IGRT의 유용성을 평가하고자 한다. 대상 및 방법 : 2014년 5월에서 2017년 11월까지 본원에 내원하여 trueBEAM Stx(Varian medical System, USA)에서 정위적체부방사선치료를 받은 환자 중 부위별로 뇌(Brain) 3명, 척추(Spine) 9명, 골반(Pelvis) 3명으로 분류하였다. 치료전 ExacTrac을 사용하여 Lateral(Lat), Longitudinal(Lng), Vertical(Vrt) 방향과 Roll, Pitch, Yaw 방향으로 Set-up 오차를 보정하였고, ExacTrac 이동 값을 적용 후 CBCT를 추가적으로 수행하여 Lat, Lng, Vrt, Rotation(Rtn) 방향으로 보정하였다. 결 과 : ExacTrac 사용시 뇌 부위의 오차는 Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, 척추 부위는 Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, 골반 부위는 Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$로 나타났다. Couch 이동 후 CBCT를 하였을 때, 뇌 부위는 Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, 척추 부위는 Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, 골반 부위는 Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$ 오차가 발생하였다. 결 론 : 정위적체부방사선치료시 ExacTrac에 추가적으로 CBCT를 사용한 Combine IGRT의 경우는 ExacTrac만 사용한 경우보다 환자의 Set-up 오차를 줄일 수 있게 나타났다. 그러나 Combine IGRT를 적용함으로 환자 Set-up 확인시간, 영상획득을 위한 체내 흡수선량이 증가한다. 그러므로 환자 상황에 따라 Combine IGRT를 사용하여 환자의 Set-up 오차를 적게 함으로써 방사선치료 효과비를 증가시킬 수 있을 것으로 사료된다.

  • PDF

ICT 인프라 이상탐지를 위한 조건부 멀티모달 오토인코더에 관한 연구 (A Study of Anomaly Detection for ICT Infrastructure using Conditional Multimodal Autoencoder)

  • 신병진;이종훈;한상진;박충식
    • 지능정보연구
    • /
    • 제27권3호
    • /
    • pp.57-73
    • /
    • 2021
  • ICT 인프라의 이상탐지를 통한 유지보수와 장애 예방이 중요해지고 있다. 장애 예방을 위해서 이상탐지에 대한 관심이 높아지고 있으며, 지금까지의 다양한 이상탐지 기법 중 최근 연구들에서는 딥러닝을 활용하고 있으며 오토인코더를 활용한 모델을 제안하고 있다. 이는 오토인코더가 다차원 다변량에 대해서도 효과적으로 처리가 가능하다는 것이다. 한편 학습 시에는 많은 컴퓨터 자원이 소모되지만 추론과정에서는 연산을 빠르게 수행할 수 있어 실시간 스트리밍 서비스가 가능하다. 본 연구에서는 기존 연구들과 달리 오토인코더에 2가지 요소를 가미하여 이상탐지의 성능을 높이고자 하였다. 먼저 다차원 데이터가 가지고 있는 속성별 특징을 최대한 부각하여 활용하기 위해 멀티모달 개념을 적용한 멀티모달 오토인코더를 적용하였다. CPU, Memory, network 등 서로 연관이 있는 지표들을 묶어 5개의 모달로 구성하여 학습 성능을 높이고자 하였다. 또한, 시계열 데이터의 특징을 데이터의 차원을 늘리지 않고 효과적으로 학습하기 위하여 조건부 오토인코더(conditional autoencoder) 구조를 활용하는 조건부 멀티모달 오토인코더(Conditional Multimodal Autoencoder, CMAE)를 제안하였다. 제안한 CAME 모델은 비교 실험을 통해 검증했으며, 기존 연구들에서 많이 활용된 오토인코더와 비교하여 AUC, Accuracy, Precision, Recall, F1-score의 성능 평가를 진행한 결과 유니모달 오토인코더(UAE)와 멀티모달 오토인코더(Multimodal Autoencoder, MAE)의 성능을 상회하는 결과를 얻어 이상탐지에 있어 효과적이라는 것을 확인하였다.

가임기 여성의 방사선 치료 시 난소 선량 평가 (Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy)

  • 박성준;이영철;김선명;김영범
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.145-153
    • /
    • 2021
  • 목 적: 본 연구에서는 가임기 여성의 유방암 방사선 치료 시 난소 선량에 대해 실험을 통하여 평가해보고자 한다. 치료기법에 따른 치료계획시스템에서 계산된 선량과 열형광선량계를 이용한 측정선량을 비교·분석하여 난소 선량을 평가하고 납(Pb) 앞치마의 사용유무에 따른 선량 분석을 통해 임상에서의 유용성을 알아보고자 한다. 대상 및 방법: 측정에는 Rando humanoid phantom을 이용하였고, 치료기법으로는 쐐기필터치료기법, 3차원 입체조형치료, 세기변조방사선치료를 사용하였다. CT simulator를 이용하여 얻은 Rando humanoid phantom 3D 영상의 우측 유방에 처방선량의 95%가 전달될 수 있도록 치료계획을 세웠고, TLD를 Rando hunmanoid phantom의 가상 표적의 표면 및 심부에 삽입하고 방사선을 조사하였다. 측정위치는 치료 중심점과 Rando humanoid phantom의 정중앙을 중심으로 반대쪽 유방으로 2cm 이동한 지점과 치료 중심축 및 하방으로 우측 유방의 경계면에서 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm, 우측 난소 위치의 표면과 중심점을 포함하여 총 9개 지점에서 측정하였다. 치료계획시스템의 선량 비교에서는 쐐기필터치료기법 2가지와 3차원 입체조형치료, 세기변조방사선치료 등 총 4개의 치료 계획을 수립하여 비교하였다. 그리고 TLD를 이용한 측정값 비교는 세기변조방사선치료와 쐐기필터를 이용한 치료를 비교하였고, 납 앞치마의 사용유무에 따라서 세기변조방사선치료의 선량차이를 측정하여 비교·분석하였다. 측정값은 각 포인트마다 3개의 TLD값 평균을 내고 TLD 교정값을 이용하여 환산하였으며 이를 Point dose mean값으로 계산하였다. 치료계획값과 실제 측정값을 비교하기 위해 각 지점마다 절대선량값을 측정하여 %Diff 값으로 계산하였다. 결 과: 치료 중심점인 Point A에서는 치료계획시스템에서 최대 201.7cGy가 나왔고, 실제 TLD 측정값은 최대 200.6cGy가 나왔다. 모든 치료계획시스템에서 유방 경계면으로부터 하방으로 17.5cm 떨어진 지점인 Point G 부터는 0cGy로 계산이 되었다. 실제 TLD 측정 결과 Point G에서는 최대 2.6cGy가 나왔고, 난소선량인 Point J에서는 최대 0.9cGy로 나타났으며 %Diff값은 0.3%~1.3%였다. 납 앞치마의 사용유무에 따른 선량 차이는 최대 2.1cGy에서 최소 0.1cGy로 나타났으며 %Diff값은 0.1%~1.1%였다. 결 론: 치료계획시스템에서 3가지 치료계획에 따른 선량차이는 최저 0.85%에서 최고 2.45%로 큰 격차를 보이지 않았다. 난소에서 Rando humanoid phantom의 치료계획과 실제 측정한 선량차이는 0.9% 이내로 나타났으나 실제 측정에서 조금 더 높게 측정되었다. 이는 치료계획시스템에서 산란선의 영향을 정확하게 반영하지 못하였고, 실제 측정에서는 TLD를 삽입한 상태로 CBCT를 촬영한 선량과 산란선량이 반영된 것으로 사료된다. 납 앞치마의 유무에 따른 선량측정에서 납 앞치마를 사용했을 경우에 치료범위에서 가까운 거리일수록 차폐의 효과가 있었으며, 치료범위에서 15cm 이상 거리가 있는 경우에는 거의 영향을 미치지 않는 것으로 나타났다. 임상적으로 방사선 치료 중에는 임신이나 인공수정을 하기에는 적절하지 않지만, 치료 중 난소에 조사된 선량은 방사선 치료 후 가임기 여성의 생식 기능에 크게 영향을 주지 않을 것으로 생각된다. 하지만 가임 여성의 경우에는 지속적인 불안감을 가지고 있으므로 이번 결과를 통한 데이터를 제시함으로써 심리적인 안정을 도모할 수 있을 것으로 사료된다.

호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가 (Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT)

  • 홍성윤;이충환;박제완;송흥권;윤인하
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.61-72
    • /
    • 2022
  • 목 적: 기존의 CBCT(Cone-beam Computed-tomography)는 호흡에 의한 움직임의 영향을 받는 부위에서 장기의 움직임으로 표적용적에 오차가 발생했다. 본 논문의 목적은 호흡동조방사선치료를 시행할 때 오차를 감소시켜주는 Gated CBCT(Gated Cone-beam Computed-Tomography)기능을 이용하여 정확성과 소요시간의 각각 유용성을 평가하고 위상에 따른 적절성에 대해 고찰하고자 한다. 대상 및 방법: Gated CBCT의 유용성을 평가하기 위해 Truebeam STxTM에서 QUASARTM 호흡 움직임 팬텀과 납 표지자 삽입물(lead marker inserts)을 이용하여 전체 위상(Full Phase), 20~80% 위상, 30~70% 위상, 40~60% 위상마다 5회씩 Gated CBCT를 촬영하여 납 표지자의 번짐(Blurring) 길이를 측정하고 투시 촬영(fluoroscopy)의 Trigger mode를 사용하여 최고 위상(Top Phase)에서 구간이 끝나는 지점까지 납 표지자가 움직이는 거리를 5회씩 측정하여 비교하였다. 삼나무 고체 종양 삽입물(Cedar Solid Tumor Inserts)을 이용하여 4차원 전산화단층촬영(4-Dimentional Computed-tomography, 4DCT)을 촬영하여 전체 위상, 20~80% 위상, 30~70% 위상, 40~60% 위상마다 표적 용적을 설정하고 축 방향(S-I방향)으로 5회씩 길이를 측정하였고 동일하게 Gated CBCT를 5회씩 촬영하고 영상의 CT 값(CT number)을 분석하여 표적이 움직인 거리를 측정하여 비교하였다. 결 과: 납 표지자 삽입물을 이용하여 촬영한 Gated CBCT에서 전체 위상은 평균 4.46 cm, 20~80% 위상은 평균 3.11 cm, 30~70% 위상은 평균 1.94 cm, 40~60% 위상은 평균 0.90 cm가 측정되었다. 투시 촬영에서 납 표지자의 축방향 움직임 거리는 평균 4.38 cm였고 Trigger mode를 이용하여 최고 위상부터 Beam off 구간까지의 거리는 20~80% 위상은 평균 3.342 cm, 30~70% 위상은 평균 2.04 cm, 40~60% 위상은 평균 0.84 cm가 측정되었다. 두 결과를 비교하였을 때 전체 위상은 0.08 cm, 20~80% 위상은 0.23 cm, 30~70% 위상은 0.10 cm, 40~60% 위상은 0.07 cm의 차이가 확인되었다. 삼나무 고체 종양 삽입물을 이용하여 촬영한 4차원 전산화단층촬영 영상으로 윤곽 묘사(contouring)한 내부표적용적(Internal Target Volume, ITV)과 치료계획용적(Planning Target Volume, PTV) 윤곽의 길이는 전체 위상에서 6.40 cm, 7.40 cm, 20~80% 위상에서 4.96 cm, 5.96 cm, 30~70% 위상에서 4.42 cm, 5.42 cm, 40~60% 위상에서 2.95 cm, 3.95 cm가 측정되었고 촬영한 Gated CBCT에서 Full 위상은 평균 6.35 cm, 20~80% 위상은 평균 5.25 cm, 30~70% 위상은 평균 4.04 cm, 40~60% 위상은 평균 3.08 cm가 측정되었다. 두 결과를 비교하였을 때 내부표적용적에서 ±8.5% 이내의 오차로 일치하는 것을 확인하였다. 결 론: 기존의 CBCT는 호흡에 의한 움직임의 영향을 받는 부위에서 장기의 움직임으로 오차가 발생하는 문제가 있었지만 본 연구를 통해서 Gated CBCT를 이용하여 설정한 위상의 표적 용적과 비슷한 영상을 얻어 정확한 영상유도를 시행하여 유용성을 확인하였다. 하지만 설정한 위상이 줄어들수록 영상 촬영소요시간이 길어진다. 따라서, 촬영소요시간과 위상의 오차를 고려했을 때 30~70% 위상 이상의 넓은 위상을 사용하는 호흡동조 정위체부방사선치료 환자에게 적용하는 것이 적절하다고 생각한다.

온라인 커뮤니티 특성과 충성도 간의 관계에 대한 연구: 자아일치성, 소비자 체험, 상호작용성의 매개적 역할을 중심으로 (A Study on the Relationship Between Online Community Characteristics and Loyalty : Focused on Mediating Roles of Self-Congruency, Consumer Experience, and Consumer to Consumer Interactivity)

  • 김문태;옥정원
    • 마케팅과학연구
    • /
    • 제18권4호
    • /
    • pp.157-194
    • /
    • 2008
  • 온라인 커뮤니티에 대한 연구는 학자들과 실무자들의 많은 관심을 받아온 분야이다. 과거 많은 연구자들이 온라인 커뮤니티를 통해 큰 상업적 성과를 거둘 수 있다고 했지만 현실은 그렇지 못하며, 마케팅 연구 분야에서도 상업적 성공을 이끄는 변수들에 대한 연구가 많이 이루어지지 못한 것이 사실이다. 이러한 점에서 본 연구는 온라인 커뮤니티 사이트들이 콘텐츠 관련 마케팅 노력을 통해 소비자들의 자아일치성을 높이고, 긍정적 체험을 유도하면서 커뮤니티 사이트 내에서 소비자 간 상호작용성 등을 높여 결국, 커뮤니티 사이트의 방문충성도 및 구매충성도를 실현시킬 수 있는 프레임 웍을 제시하였다. 연구결과 온라인 커뮤니티 사이트에서 소비자 간 상호작용성이 방문충성도 그리고 특히 구매충성도의 구축에 매우 중요한 요인으로 밝혀졌고, 온라인 커뮤니티 사이트에 대한 자아일치성 지각 및 긍정적인 소비자 체험 또한 소비자의 상호작용성, 방문충성도 그리고 커뮤니티에 대한 애정에 상당히 중요한 요인임을 알 수 있었다. 또한 이러한 매개변수에 주된 영향요소로서 콘텐츠 우수성, 사이트 생동감, 네비게이션용이성, 고객화 등의 콘텐츠 관련 마케팅 노력의 역할의 중요성을 강조하였다.

  • PDF