• Title/Summary/Keyword: image center

Search Result 4,289, Processing Time 0.037 seconds

Antiferroelectric Liquid Crystal Display with High Image Quality

  • Chang, Young-Joo;Yu, Jeong-Seon;Yoo, Jeong-Geun;Jeong, Dong-Jin;Park, Sung-Chon;Chae, Su-Yong;Yang, Hong-Geun
    • Journal of Information Display
    • /
    • v.3 no.4
    • /
    • pp.1-3
    • /
    • 2002
  • The antiferroelectric liquid crystal display (AFLCD) is a unique display that can at demonstrate a moving image perfectly the passive matrix driving scheme. We optimised driving the waveform and introduced a dual-driving method. Also, by improving this driving method and using line inversion method, we realize the AFLC display of high image quality with $160(RGB){\times}240$, 32768 colors, crosstalk free and flicker free contrast ratio is greater than 60:1, and the brightness is above 200 $cd/m^2$.

Antiferroelectric Liquid Crystal Display with High Image Quality

  • Yu, Jeong-Seon;Chang, Young-Joo;Yoo, Jeong-Geun;Jeong, Dong-Jin;Park, Sung-Chon;Chae, Su-Yong;Yang, Hong-Geun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.545-547
    • /
    • 2002
  • The antiferroelectric liquid crystal display (AFLCD) is unique display that can show the perfect moving image using the passive matrix driving scheme. We optimized the driving waveform and introduced the dual driving method. Also, by improving this driving method and using line inversion method, we realized AFLC display with high image quality, which has 160(RGB)${\times}$240, 32768colors, crosstalk free and flicker free. The contrast ratio is greater than 60:1, and the brightness is above 200cd/$m^2$.

  • PDF

Compensation of OLED Degradation by AMOLED Pixel Circuit

  • Choi, Sang-Moo;Goo, Bon-Seok;Kang, Jin-Goo;Kim, Keum-Nam;Kim, Yang-Wan;Choi, Woong-Sik;Kim, Byung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.466-469
    • /
    • 2009
  • The life time of AMOLED displays has been dependent on OLED materials up to this point. In particular, image sticking (burn-in) has been one of the most critical issues for AMOLEDs. This paper proposes image sticking compensation AMOLED pixel circuits to address the problem without requiring process or material improvements to the OLED itself. We verified the performance of those circuits by simulation and actual panel implementation.

  • PDF

Adaptive Directional Filtering Techniques for Image Sequences (동영상을 위한 적응 방향성 필터링 기술)

  • 고성제
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.7
    • /
    • pp.922-934
    • /
    • 1993
  • In this paper, statistical properties of the spatiotemporal center weighted median(CWM) filter for image sequences are investigated. It is statistically shown that the CWM filter preserves image structures under motion at the expense of noise suppression. To improve the CWM filter, a filter which can be effectively used in image sequence processing, the adaptive directional center weighted median filter (ADCWM), is proposed. This filter utilizes a multistage filtering structure based on adaptive symmetric order statistic(ASOS) operators which produce a pall of order statistics symmetric about the median. The ASOS's are selected by using adaptive parameters adjusted by local image statistics. It is shown experimentally that the proposed filter can preserve image structures while attenuating noise without the use of motion estimation.

  • PDF

New Evaluation System of Cosmetic Effects on Morphology of Skin Surface Using TSRLM with Image Analyser

  • Kim, Jong-Il;Lee, Joa-Hoon;Lee, Yoo-Young;Kim, Chang-Kew
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.16 no.1
    • /
    • pp.47-63
    • /
    • 1990
  • Image analyser was used to understand the condition of skin surface and to evaluate the efficacy of cosmetic treatment. It was unsatisfactory to analyse skin surface structure although several methods using image analyser had been presented. We developed the new system composed of image analyser and Tandem Scanning Reflected Light Microscope (TSRLM) having the remarkable optical sectioning property as image input device. By using this new system, we quantitatively measured the change of skin surface, the depth and width of furrow in micron unit, resulted by cosmetic treatments. And also three dimensional image of skin was reconstructed with serial sectioned images, which were captured through TSRLM, for better understanding of the effect of cosmetic treatment. It was found that skin relief was more easily understood and the change of skin surface caused by cosmetic treatment was more accurately measured by using this system. In addition, we was also aware of the possibility of in vivo direct measurement of skin furrow without replica. It was conceivable that our system could be applicable for study of cosmetic effects further.

  • PDF

Vision Inspection and Correction for DDI Protective Film Attachment

  • Kang, Jin-Su;Kim, Sung-Soo;Lee, Yong-Hwan;Kim, Young-Hyung
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.2
    • /
    • pp.153-166
    • /
    • 2020
  • DDI(Display Driver IC) are used to drive numerous pixels that make up display. For stable driving of DDI, it is necessary to attach a protective film to shield electromagnetic waves. When the protective film is attached, defects often occur if the film is inclined or the center point is not aligned. In order to minimize such defects, an algorithm for correcting the center point and the inclined angle using camera image information is required. This technology detects the corner coordinates of the protective film by image processing in order to correct the positional defects where the protective film is attached. Corner point coordinates are detected using an algorithm, and center point position finds and correction values are calculated using the detected coordinates. LUT (Lookup Table) is used to quickly find out whether the angle is inclined or not. These algorithms were described by Verilog HDL. The method using the existing software requires a memory to store the entire image after processing one image. Since the method proposed in this paper is a method of scanning by adding a line buffer in one scan, it is possible to scan even if only a part of the image is saved after processing one image. Compared to those written in software language, the execution time is shortened, the speed is very fast, and the error is relatively small.

Medical image control process improvement based on Cardiac PACS (Cardiac PACS 구축에 따른 의료영상 관리 프로세스 개선)

  • Jung, Young-Tae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • Heart related special images are classified as Cardiac US, XA, CT, MRI. Several Problem is caused by image compression, control and medical support point, so most big hospitals have created a Cadiac PACS differentially in past years. For this reason, create a conflict in inner colleague and patient, protector that result from 2 data processing server operating independently in 1 medical center area. For this reason, we sugges an alternative model of best medical control process together with understand the current situation on medical facility.

  • PDF

Extraction of location of 3-D object from CIIR method based on blur effect of reconstructed POI

  • Park, Seok-Chan;Kim, Seung-Cheol;Kim, Eun-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1363-1366
    • /
    • 2009
  • A new recognition method is used to find the three-dimensional target object on integral imaging. For finding the location of a target image, amount of reconstructed reference image is needed. This method is giving accurate information of target image by correlated among reconstructed target images and reference images.

  • PDF

Center Determination for Cone-Beam X-ray Tomography

  • Narkbuakaew, W.;Ngamanekrat, S.;Withayachumnankul, W.;Pintavirooj, C.;Sangworasil, M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1885-1888
    • /
    • 2004
  • In order to render 3D model of the bone, the stack of cross-sectional images must be reconstructed from a series of X-ray radiographs, served as the projections. In the case where the distance between x-ray source and detector is not infinite, image reconstruction from projection based on parallel-beam geometry provides an error in the cross-sectional image. In such case, image reconstruction from projection based on conebeam geometry must be exercised instead. This paper is devoted to the determination of detector center for SART conebeam Technique which is critically effect the performance of the resulting 3D modeling.

  • PDF

Development of multi-object image processing algorithm in a image plane (한 이미지 평면에 있는 다물체 화상처리 기법 개발)

  • 장완식;윤현권;김재확
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.555-555
    • /
    • 2000
  • This study is concentrated on the development of hight speed multi-object image processing algorithm, and based on these a1gorithm, vision control scheme is developed for the robot's position control in real time. Recently, the use of vision system is rapidly increasing in robot's position centre. To apply vision system in robot's position control, it is necessary to transform the physical coordinate of object into the image information acquired by CCD camera, which is called image processing. Thus, to control the robot's point position in real time, we have to know the center point of object in image plane. Particularly, in case of rigid body, the center points of multi-object must be calculated in a image plane at the same time. To solve these problems, the algorithm of multi-object for rigid body control is developed.

  • PDF