• 제목/요약/키워드: image analyzer

검색결과 299건 처리시간 0.028초

Image Analyzer를 이용한 수삼등급의 자동판정 I. 수삼등급 별 체형과 중량분석 (Automatic Decision-Making on the Grade of 6-Year-Old Fresh Ginseng (Panax ginseng C.A. Meyer) by an Image Analyzer 1. Shape and Weight Analyses according to the Grade of Fresh Ginseng)

  • 강제용;이명구;김요태
    • Journal of Ginseng Research
    • /
    • 제20권1호
    • /
    • pp.65-71
    • /
    • 1996
  • This study was undertaken to evaluate the automatic decision-making on the grading of 6-year-old fresh ginseng (Panax ginseng C.A. Meyer) by an image analyzer. The best input method for the 6-year-old fresh ginseng was under condition of a low resolution (128u 128 pixel) and illumination direction from bottom to up (light box). It was possible to identify the main root, lateral root, and rhizome of fresh ginseng by application of OPEN process in a function of an image analyzer. Finally, we developed the grade decision-making programs, GinP-1. The fitness rates for the fresh ginseng standards which were classified by experts were 94.6, 80.6, 81.5, and 100.0% for 1st, 2nd, 3rd, and 4th grade of fresh ginseng, respectively, and the total time of decision-making was about 4.3 seconds per one root. The decision-making time was reduced to 0.8 seconds per one root by enhancemeat of the Image analyzer, which was tested by the technical company of the image analyzer,'Carl Zeiss (Germany). As a result of this study, the automatic decision-making on the grade of fresh gin send by image analyzer seems to have high possibility.

  • PDF

주파수 해석기와 M-mode 영상을 갖는 펄스 도플러 장치의 개발에 관한 연구 (A Study on the Pulse Doppler System with M-mode Image and Spectrum Analyzer)

  • 정택섭;박세현;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1217-1220
    • /
    • 1987
  • We have developed a Ultra Sound Pulsed Doppler System with two-dimensional M-mode image and Spectrum analyzer. The image of the M-mode is composed of time and depth axes. The Spectrum analyzer shows the spectrum of Doppler signal which represents the velocity component of time dependent blood-flow behavior. The spectrogram using Spectrum analyzer is composed of frequency and amplitude axes. The outputs of the system are audio signals, velocity curves, velocity profiles, M-mode images and spectrogram.

  • PDF

Image Analyzer를 이용한 수삼등급의 자동판정 II. 수삼의 적변판정 (Automatic Decision-Making on the Grade of 6 Year-Old Fresh Ginseng (Panax ginseng C. A. Meyer) by an Image Analyzer II. Decision of Rusty Root of Ginseng)

  • 강제용;이명구
    • Journal of Ginseng Research
    • /
    • 제26권1호
    • /
    • pp.6-9
    • /
    • 2002
  • 본 연구는 현재 수삼수납 시 품질검사요원의 관능검사로 판정되고 있는 6년근수삼의 적변판정에 대하여 영상분석기를 이용한 수삼의 적변 자동판정 시스템을 개발하고자 수행하였다. 영상분석기에 의한 수삼 총면적에 대한 grey valuequf 면적비율을 조사하여 이에 대한 회귀 및 판별분석을 실시한 결과, 정상삼과 적변삼을 구별할 수 있는 임계값은 총 면적에 대한 grey value 148에서의 면적비율(G148)로 분석되었으며, 임계값인 G(148)을 이용하여 다음과 같은 판별식을 구하였다. 적변삼의 판별식 : 6.67951$\times$G(148)+3.74122, 정상삼의 판별식 : 2.85942$\times$G(148)+9.95612, 본 판별식의 적중율은 89.8%로 이는 앞으로 계속적인 연구로 적변삼의 판정 적중율을 증가시킬 수 있을 것인 바, 컴퓨터 등 기계에 의한 적변 자동판정의 가능성은 매우 클 것으로 사료된다.

CCD image system을 갖는 유전체칩 분석장치를 위한 효율적인 광학시스템 설계 (Effective Optical System Design for Biochip Analyzer with CCD Image System)

  • 배수진;강욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.488-491
    • /
    • 2003
  • Biochip-based diagnostic technology is an effective, time- and money- saving way. But, biochip analyzer including CCD imaging system has a complete optical system. It is one of reasons that the cost of biochip analyzer is expensive with CCD imaging system. In this paper, We suggested the simple and effective optical system for biochip analyzer with CCD imaging system. It consists of two parts with the same structure but opposite direction. Each part consists of achromatic doublet and meniscus. Suggested optical system has less lenses than existing system and more efficiently.

  • PDF

MOFIA에 의한 두개 입자/기포간 상호작용에 관한 연구 (Characterization of Interaction between Two Particles/Bubbles Flow with Moving Object Flow Image Analyzer System)

  • 최해만;문자수명;송정강일
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.110-116
    • /
    • 2005
  • This paper deals with interaction between two bubbles or particles and flow around them, visualized by a moving object flow image analyzer(MOFIA) consisting of a three-dimensional (3D) moving object image analyzer(MOIA) and two-dimensional particle image velocimetry(PIV). The experiments were carried out for rising bubbles or particles of various densities, sizes, and/or shapes in stagnant water in a vertical pipe. In the MOFIA employed, 3D-MOIA was used to measure particles or bubbles motion and PIV was used to measure fluid flow, The experimental results showed that the interaction was characterized by the shape, size and density of two particles or bubbles.

이미지 분석기법을 이용한 SV30 자동감지방법 및 탁도 추정 모델 개발 (Development of SV30 Detection Algorithm and Turbidity Assumption Model using Image Analysis Method)

  • 최수정;김예진;염훈식;차재환;최재훈;김창원
    • 대한환경공학회지
    • /
    • 제30권2호
    • /
    • pp.168-174
    • /
    • 2008
  • 본 논문에서는 하수처리장의 자동 계측 제어 시스템을 구축함에 있어 제한 요소로 작용되는 2차 침전조의 침전 상태를 자동으로 진단하기 위해 이미지 분석 기법을 적용한 On-line SVI(Sludge Volume Index) analyzer를 이용하였다. 침전 상태를 알아보기 위해 카메라로 촬영한 디지털 이미지로부터 RGB(Red-Green-Blue) 프로파일을 얻었으며, 이를 통해 상등수와 슬러지층의 경계를 자동으로 감지할 수 있는 SV30 감지 알고리즘을 제안하였다. 개발된 SV30 감지 알고리즘은 벌킹, 핀플럭과 같은 침전 문제 발생 시에도 신뢰성 있는 감지능을 보여주었다. 또한 본 논문에서는 상등수 부분의 RGB 값과 실제 운전자에 의해 측정된 탁도 값 사이의 상관관계를 통하여, 탁도 추정 모델을 제안하였다.

신문지 재활용 공정의 일차 점착성 이물질 실시간 정량을 위한 새로운 방법 (New Method for Real-Time Analysis of Primary Stickies in ONP Recycling Process)

  • 김동호;류정용;김용환;송봉근
    • 펄프종이기술
    • /
    • 제35권4호
    • /
    • pp.23-33
    • /
    • 2003
  • The possibility of real time analysis about hot melt resins and pressure sensitive adhesives in newsprint stock was investigated by performing comparative tests using conventional image analysis method and real time contaminants analyzer. Based on the test results, the performance of real time contaminants analyzer in terms of detecting primary stickies in newsprint stock could be verified. Real time stickies analysis showed good precision and over-estimation of hot melt resins and under-estimation of pressure sensitive adhesives could be corrected by adapting new method. Real time analysis of primary stickies in the actual newsprint stock also showed good correlation with conventional image analysis and the performance of real time contaminants analyzer could be verified again. Adjustment of the contrast sensitivity of real time contaminants analyzer was enough to set the proper monitoring conditions for primary stickies in newsprint stock.

스트립의 컬러영상을 이용한 요 분석기에 관한 연구 (A Study on Urine Analyzer Using Color Images of Strip)

  • 조용현
    • 한국지능시스템학회논문지
    • /
    • 제17권7호
    • /
    • pp.919-923
    • /
    • 2007
  • 본 논문에서는 스트립의 컬러영상을 이용한 요 분석기의 개발을 제안하였다. 제안된 분석기에서 스트립의 컬러영상획득을 위해 이미지센서를 이용하였으며, 상이한 요성분에 반응하는 독립된 각 패드들의 영상을 한 번에 촬영하고, 촬영된 패드컬러를 분석하여 요성분의 측정값을 출력하는 특징을 가지도록 하였다. 특히 개발된 장치는 11개의 요 성분을 측정 분석하는 장치로 프로세서에 의하여 측정된 색상을 처리함으로써 복잡한 과정을 없앨 수 있어 빠른 동작과 가벼우며, 소형화되고, 가시적 판단 때보다 정확성을 매우 높일 수 있었다. 또한 유 무선의 통신인터페이스에 의하여 다른 검사기능을 가진 외부장비나 개인용 컴퓨터 및 의료기관이나 기타 요구하는 다른 곳으로 전송이 가능하도록 하였다.

치과용 고주파 주조기를 이용한 Co-Cr-Mo계 합금 용해과정의 적외선 열화상 분석 (Analysis of infrared thermal image for melting processes of Co-Cr-Mo based alloy using high frequency induction casting machine)

  • 강후원;박영식;황인;이창호;허용;원용관
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.149-158
    • /
    • 2014
  • Purpose: Dental casting Co-Cr-Mo based alloys of five kinds of ingot type and two kinds of shot type were analyzed the melting processes with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer. Methods: When Co-Cr-Mo based alloys were put about 30g/charge in the ceramic crucible of high frequency induction centrifugal casting machine and heat, Infrared thermal image analyzer and IR thermometer indicated these alloys in the crucible were set and operated. Results: The melting temperatures of alloys measuring infrared thermal image analyzer were deviated ${\pm}10^{\circ}C$ compared to those of manufacturing company. On the other hand, the melting time of alloys were differently appeared with the shape of alloys(ingot and shot type). Conclusion: The melting temperatures of dental Co-Cr-Mo based alloys were measured the degree of $1,360{\sim}1410^{\circ}C$ and the heating time with the alloys of ingot and shot type were deviated ${\pm}10sec$.