Search Result 1,299, Processing Time 0.02 seconds

A Study on Comparative Analysis of Power Consumption Characteristics in long Tunnel Customers (장터널 수용가의 전력사용 특성 비교 분석)

  • Kim, Se-Dong;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.141-145
    • /
    • 2013
  • This paper shows a reasonable demand power, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 7 years of each tunnel customer as to AMR. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried by the linear and nonlinear regression analysis.

A Study on the Cost Effective DSM Method for Lighting Power Control through Pilot Test Based on Pre-Verified Methodologies (다양한 형태의 조명(형광등) 전력제어 실증시험을 통한 비용효과적인 전력수요관리방법 도출)

  • Yang, Seung-Kwon;Kim, Dae-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.7-13
    • /
    • 2013
  • The portion of lighting power consumption for our country is up to 20~30% of the total amount. Currently, most of the DSM(Demand side management) of lighting power is delivered in supply of high efficient lighting to customers. On the contrary, applications of lighting power to power load leveling are still rare. In this paper, the simulations for various control types of lighting power for load leveling are tried, and we obtained the cost effective and optimal control method through that. This simulation was executed in test office with fluorescent light by us based on applying 8 control types(on, off & dimming), considering customers' satisfaction, for instance, minimum intensity of illumination allowed. According to the result of this test, we found that mixed type(chessboard(on-off) plus dimming control(10%)) is most effective.

Power Control modeling and Simulation of Hybrid Power System for Building Microgrid Connected Application

  • Yoon, Gi-Cap;Cho, Jae-Hoon;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.84-93
    • /
    • 2009
  • In this paper, we propose to study the possibility of using a photovoltaic system combined with a high speed micro-turbine. This hybrid system can work as stand-alone system or grid connected system as it will be a part of a micro-grid. Initially, we propose Matlab/Simulink dynamic models of photovoltaic, micro turbine systems and supercapacitor. Then, we carry out a simulation comparison of the two systems, this is, with supercapacitor and without supercapacitor bank. We show that supercapacitor bank as short-term storage device was necessary to reduce the fast fluctuation of power in the case of sensitive loads. It is verified the simulation results of Matlab/Simulink based hybrid power system represent the effectiveness of the suggested hybrid power system.

Development of Multi-flat Reflector Sun Tracking System for Sun Photocell Maximum Power Generation (태양전지 최대전력 발생을 위한 다 평면 반사경 태양추적시스템 개발)

  • Lee, Kang-Sin;Lee, Hyun-Seog;Yoo, Seok-Ju;Park, Wal-Seo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.67-72
    • /
    • 2011
  • Recently, photovoltaic generator system is widely extended by energy policy of the government. Add to this, for high efficiency of power generation per natural light unit area is needed to sun tracking system. And it is needed to condensed light generator for reducer of equipment expense. As method of solving this problem, this paper is developed multi-flat reflector sun tracking system for sun photocell maximum power generation. The system is consisted of multi-flat reflector and two axes machinery and sun location perceiver and AVR controller. GaAs 3J cell generated 6.75 times power more than silicon cell by times condensing light system. As a result, condensing light system of multi-flat reflector generated maximum power and showed reducing costs to photovoltaic generator.

Evaluation of Discharge Characteristics Followed by the Development of Blumlein Pulsed Power Source (Blumlein 펄스파워 전원개발 및 방전특성 평가)

  • Han, Sang-Bo;Park, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.99-105
    • /
    • 2010
  • This paper discussed the theoretical simulation results for developing the blumlein pulsed power source and showed the circuit configuration and the discharge characteristics of the realistic manufactured pulsed power system. In the simulation, the output voltage characteristics at a load resistor showed the general impulse shape when the impedance of a single coaxial cable is matched with the that of a load resistor. In addition, it is confirmed that output values of the pulsed power can be easily controlled by the duplication of coaxial cables and the pulsed waveform showed the general impulse characteristics. Specifically, the inception discharge voltage in the gap distance of 5[mm] between needle and plane electrodes is about 20[kV] and which is lower than about 29[kV] in 9[mm] due to the difference of the reaching time of the inception voltage. Therefore, this paper showed that the output voltage of the blumlein pulsed power source can be easily controlled.

A Study on the Security-Constrained Economic Dispatch for Power System (전력계통의 안전도를 고려한 경제급전에 관한 연구)

  • 김경철;최홍규;원진희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.7-14
    • /
    • 2002
  • The economic dispatch is one of the major concerns in case of buying and selling generated powers between electric powers companies. This paper describes the power system security the optimal power flow, and the security-constrained economic dispatch and shows the EDSA\`s active optimal power flow software package is well suited through a simple case study.

Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company (금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석)

  • Chang, Hong-Soon;Han, Young-Sub;Hwang, Ik-Hwan;Seo, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.

Analysis of Effect of Designated New Technology of Electric Power on the Electrical Construction Industries (전력신기술 제도가 전기공사업계에 미치는 영향 분석)

  • Hwang, Min-Soo;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.106-113
    • /
    • 2012
  • Recently laws have been enacted to build and promote the use of smart grid. There are also increasing demands for the compliance with international trade agreements and the related international standards. Due to these rapid changes in electric power industry and the market expansion, importances of new technologies and processes have been being increased. To reflect these international trends, the government have carried out the designation of new technology for electric power industry to promote domestic industries and national competitiveness by inspiring technology developments in individual or private industry sectors. In this paper analysis of the current status of the designation of the new technology of electric power has been presented including its problem and effect on the related industries. The analysis is expected to be utilized to enhance sound development and to vitalize the electrical new technology regulation.

Power Quality Monitoring System Using DWB on Distribution Automation System (DWB를 이용한 배전자동화 기반의 전기품질 모니터링 시스템 구축)

  • Kang, Moon-Ho;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.86-93
    • /
    • 2011
  • The necessity of Power Quality(PQ) Management grow bigger because the disturbance strength in power system is increasing, on the other hand, the tolerance of electrical components is reducing with widely use of the IT and digital equipments. The domestic management standards on power quality are enacted based on the IEC standards in recent. Since the IEC standards defines the measurement and evaluation point on PQ as PCC(Point of Common Coupling) which is normally the point of penetration between customer and power company, the PQ monitoring system(PQMS) should be made to measure and manage the PQ of custom effectively. In this paper, therefore, the economical construction plan on PQMS using the wireless communication channel in distribution automation system is suggested, and the usefulness of the PQMS are shown by analyzing the PQM data with IEC standards.

Reliability Analysis of Power System with Dependent Failure (종속고장을 고려한 전력시스템의 신뢰도 평가)

  • Son, Hyun-Il;Kwon, Ki-Ryang;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.62-68
    • /
    • 2011
  • Power system needs to sustain high reliability due to its complexity and security. The reliability prediction method is usually based on independent failure. However, in practice, the Common Cause Failures(CCF) and Cascading failure occur to the facilities in power system as well as independent failures in many cases. The CCF and Cascading failure turn out the system collapse seriously in a wide range. Therefore to improve the reliability of the power system practically, it is required that the analysis is conducted by using the CCF and Cascading failure. This paper describes the CCF and Cascading failure modeling combined with independent failure. The incorporated model of independent failure, CCF and cascading failure is proposed and analyzed, and it is applied to the distribution power system in order to examine this method.