• Title/Summary/Keyword: illuminating power

Search Result 1,299, Processing Time 0.027 seconds

Design of New Current Full-Bridge Resonant Inverter for Induction Heating System (유도가열 시스템을 위한 새로운 전류형 풀-브릿지 공진형 인버터 설계)

  • Lee, Sang-Hun;Lim, Sang-Kil;Song, Seung-Gun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.59-69
    • /
    • 2012
  • There are two types of inverters that are generally used in induction heating systems: voltage type inverters and high-frequency half-bridge inverters. This paper proposes a new resonant inverter for induction heating systems using the current type full-bridge method. The proposed method can remove capacitors at the input end, and enables unity power factor operation by preventing phase differences of voltage and current. Furthermore, Zero Voltage Switching (ZVS) which is in tune with current type inverter can be adopted and continuous power adjustment is possible through duty ratio changes and frequency modulation in switching operation. Simulations and experiments showed that the proposed current type full-bridge resonant inverter could be used for unity power factor control and ZVS operation in induction heating systems.

A Study on the Wireless Power Transfer System using Magnetic Resonance at the 1[MHz] Frequency Band (1[MHz] 대역의 자계 공명을 이용한 무선 전력 전송 장치에 관한 연구)

  • Park, Jeong-Heum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed, analyzed by circuit analysis methode and the calculated transfer function was compared with the measured one. The self-resonant coil was made up of the commonly used capacitor which had the lumped capacitance and it enabled the stable magnetic resonance not to be affected by the circumstance. The transmission efficiency of this system was 70[%] at the 15[cm] between the transmission and receiving coil and the measured transfer function was similar to the calculated one, which means the circuit analysis methode is valid in this system. When the intermediate coils were added between the transmission and receiving coil, the transmission efficiency was increased, which produced the increase of transfer distance. In the case of the five intermediate coils adding, the 35[%] transmission efficiency was achived at the 90[cm] distance.

Profiles of Electric and Magnetic Fields around 22.9[kV] Distribution Lines (22.9[kV] 배전선로 주변의 전장과 자장의 분포)

  • ;李福熙
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.178-178
    • /
    • 1999
  • In recent years, the electromagnetic environments are varied with the increase of power consumption and the spread of household electric appliances. Most of the interests to date have concentrated in the area of human health effects associated with exposure to power frequency electric and magnetic fields, and thus the precise measurement and analysis are required. In this paper, the measurements and analysis of the extremely low frequency(ELF) electric and magnetic fields produced by actual 22.9[kV] distribution lines were performed. The experiments have been carried out by lateral profile, and the theoretical analyses were made by use of FIELDS program for the sate of comparison with the experimental data. Electric and magnetic field intensity were strong under power distribution lines, and were inversely proportional to lateral distance. The profiles of electric and magnetic fields were M and ∩ shapes, respectively, and the measured data were good in agreement with the theoretical results. Both the electric and magnetic field intensity were increased with increasing the measurement height.

A Study on Hight Efficiency Inverter Ballast using Microprocessor (마이크로프로세서를 사용한 고효율 인버터 안정기에 관한 연구)

  • ;鄭載倫
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.220-220
    • /
    • 1999
  • This paper describes the high efficiency inverter ballast circuit using very cheap microprocessor, which has been developed by the author. A variety of soft-switching techniques have been proposed to reduce the switching losses and EMI problems that occur with higher switching frequencies in switched inverter ballast. The inverter ballast circuit, which employs a temperature sensing circuits has been also proposed to improve starting performance of the fluorescent lamps. That is, the inverter ballast circuit, which employs a soft-starting circuit and soft-switching techniques to implement the power factor correction and to mitigate of power-loss and increase a life time of the fluorescent lamps, has become an attractive performance for ballasting the fluorescent lamps. In this paper, the operation and the control of the inverter ballast are described in detail and experimental results are presented. As the experimental results, when environment temperature is at -40℃, the inverter ballast circuit has low THD(4.8%) of the input current and large power factor(98%) of the lamp current. The proposed improved ballast circuit appears to be a good performance for ballasting fluorescent lamps.

Quantitative Evaluation of the Customers' Effect by Automatic Reclosing of Power Distribution System (배전시스템에서의 재폐로에 의한 수용가측 영향의 정량적 평가)

  • 임성정;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.7-14
    • /
    • 1998
  • This paper presents an approach to quantitatively evaluate customers' effect due to automatic reclosing of power distribution systems. This proposed approach assess the customers' effect on equip ment halt by predicting a momentary interruption and voltage sag and analyzing the impact of customers' equipment sensitive to electric disturbances. Simulation results show that the increment of the number of reclosing improves the service reliability, but deteriorates the power quality for customers. The proposed approach utilizes the determination of automatic reclosing scheme and distribution system planning.anning.

  • PDF

Series Arcing Fault Detection Method Using Harmonics Analysis of Supply Current (전원 전류 고조파 해석에 의한 직렬 아크 고장 검출 방안)

  • Ahn, Jeongwoon;Oh, Yong-Taek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.30-37
    • /
    • 2014
  • Recently, Concerns of imbalance for power supply has been raised by the increase of electric power consumption, but the interest of electric safety is still lacking due to the incompleteness of regulations. Particularly, Arcing fault, direct cause of electric fire accidents, is difficult to detect, interrupt due to unformal signal behaviour in previous research and apply to real system. In this paper, Arcing fault simulator device was fabricated to investigate the characteristics of series arcing fault and simulated the faults in various real load. Also, this study are analysed arcing fault signal by using the harmonic analysis of the acquired data from the current of the power supply and proposed the methods to prevent the series arcing fault accidents in advance.

A Study on the Signal Analysis of Corona Discharge on the Polymer Insulator using UV Sensor Array (UV 센서 어레이를 이용한 폴리머 애자의 코로나 방전 신호분석 연구)

  • Choi, Myeong-Il;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.16-20
    • /
    • 2014
  • To prevent any accident in electric power utilities, many researches for inspection and diagnosis deteriorations occurring by corona discharges have been continuously studying. Inspection and diagnosis of electric power utility is very important to prevent an accident. This paper studies a measurement of ultra-violet(UV) ray of corona discharges on polymer insulators using an UV sensor array with an optic lens. The detection of an UV signal begins at 60kV, which is about 37.5% of the breakdown voltage of the polymer insulator and the stronger the high voltage increased to the polymer insulator was. It can be determined that the polymer insulator mounted on a live part must be examined when the discharge risk exceeds approximately 40%. In conclusion, the status of power utilities can be checked using an UV sensor.

The Development of Transient Analysis Model and Performace Analysis of 345[kV] 100[MVA] STATCOM (345[kV] 100[MVA] STATCOM 과도해석 모델 개발 및 동특성 분석)

  • Yoon, Jong-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.28-34
    • /
    • 2011
  • This paper describes the development of the transient analysis model of 345[kV] 100[MVA] STATCOM and the result of the performance analysis. The Korea power utility company, KEPCO began a commercial operation of a 100[MVA] STATCOM(Static synchronous COMpensator) at 345[kV] Migeum substation in Seoul. In order to operate a new control device like STATCOM to the power system, suitable transient model is needed. Therfore, Korea Electric Power Coporation(KEPCO) developed a transient analysis models using EMTDC/PSCAD. The development of this transient analysis model is based on the actual STATCOM S/W algorithm and H/W specification that was provided by its manufacture. Through this model, the transient/dynamic performance of STATCOM at Migeum substation can be analyzed.

Applied Spherical Lens with Reflect Mirror for the CPV module (반사판 적용 구형렌즈를 갖는 집광형 태양전지모듈)

  • Lee, Kang-Yeon;Jeong, Byeong-Ho;Kim, Hyo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.83-90
    • /
    • 2011
  • There are two main types of concentrating optical systems in use today: refractive types that use Fresnel lenses, and reflective systems that use one or more mirrors. Regardless of the chosen optical system, the result is concentrated sunlight being aimed at the sensitive face of the cell, to produce more energy from less photovoltaic material. In this paper, for the achieve trackerless CPV system, CPV module included that the spherical lens with reflect mirror makes it possible to achieve high and stable power generation performance for the high concentration photovoltaic power generation system and cope with the needs for a variety of shapes and sizes in flexible manners and that the multiple cavity assemble method greatly reduces costs. Development of these high performance multi-junction CPV module promises to accelerate growth in photovoltaic power generation.

Analysis on Voltage Compensating Effect of DVR using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 DVR의 전압보상 효과분석)

  • Park, Sang-Ho;Choy, Young-Do;Park, Young-Shin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.165-171
    • /
    • 2010
  • There are many researches on Power Quality Device to protect the critical load and power system as the nonlinear load and precision load are adopted into the power system recently. To analyze the voltage compensation of voltage sag and voltage swell by DVR, which is connected to the important load in series, this paper shows PSCAD/EMTDC simulation and its verification by comparing with the actual DVR output of 2MVA. DVR control scheme in this paper is applicable to compensate single-phase, 2-phases or 3-phases voltage sag as well as DVR for distribution system.