• Title/Summary/Keyword: illuminating power

Search Result 1,300, Processing Time 0.021 seconds

Design of Active Power Factor Corrector for Low Power Supply by Loss Free Resistor Concept (무손실 저항개념을 이용한 저전력 전원설비용 능동 역률보정기의 설계)

  • 임영철;정영국;최찬학;나석환;이건식;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.1
    • /
    • pp.30-36
    • /
    • 1993
  • A simple discontinuous conduction mode(DCM) flyback type active power factor corrector for low power supply resents an effective resistive load to its power input. It is therefore well suited as an inexpensive high power factor rectifier for office equipment. An equivalent circuit model for the Active Power Factor Corrector based on the "Loss Free Resistor" concept is presented. This simple model correctly describes the basic power processing properties of the Active Power Factor Corrector, including input port resistor emulation, output port power some characteristics.teristics.

  • PDF

Development of Start·Stop Control System at Water Turbine Generator for Tidal Power Plant (조력발전소를 위한 수차발전기의 기동·정지 제어시스템 개발)

  • Cho, Byong-Og;Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.106-112
    • /
    • 2014
  • Recently, tidal power generation has gained much attention. South Korea's tidal power generation systems were imported from abroad by turnkey type and have being operated. Therefore, for efficient operation and technological independence of a tidal power system, development of core technology is required. This paper deals with the start stop control system of water turbine generator in the tidal power plant, as one of our development project results. Using the SCADA system, the status and operations of water turbine generator in the tidal power plant, as well as simulation for calculation of maximum power were carried out. A small model type of start stop control device was also developed. In addition, the control system in Sihwa tidal power plant was modeled, and the results obtained by the dynamic simulation were given in graphics by 2D simulator.

Analysis for Voltage Fluctuation and Power Flow at the Grid-Connected Time of Squirrel-Cage Induction Generator (농형 유도발전기의 계통 연계시 전압 변동 및 전력 흐름 분석)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.45-51
    • /
    • 2014
  • Synchronous generators and induction generators are mainly used in hydroelectric power generation. Synchronous generator is mainly applied to large hydroelectric plants but induction generator is applied to the small hydro power plants. Stability of induction generator is slightly less than the synchronous generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So Induction generator is used primarily in small hydroelectric power station less than 1,000kW recently. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to reduce the voltage drop and to analyze the power flow, the analysis for operating characteristics of the induction generator should be reviewed in advance. In this study, we analyzed the voltage drop and power flow analysis when a 1500kW induction generator is connected to the grid. The voltage drop is slightly higher than the acceptable range of distributed power supply voltage and the power flow of the generator is performed well.

A Variable Step Size Incremental Conductance MPPT of a Photovoltaic System Using DC-DC Converter with Direct Control Scheme

  • Cho, Jae-Hoon;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.74-82
    • /
    • 2013
  • This paper presents a novel maximum power point tracking for a photovoltaic power (PV) system with a direct control plan. Maximum power point tracking (MPPT) must usually be integrated with photovoltaic (PV) power systems so that the photovoltaic arrays are able to deliver maximum available power. The maximum available power is tracked using specialized algorithms such as Perturb and Observe (P&O) and incremental Conductance (indCond) methods. The proposed method has the direct control of the MPPT algorithm to change the duty cycle of a dc-dc converter. The main difference of the proposed system to existing MPPT systems includes elimination of the proportional-integral control loop and investigation of the effect of simplifying the control circuit. The proposed method thus has not only faster dynamic performance but also high tracking accuracy. Without a conventional controller, this method can control the dc-dc converter. A simulation model and the direct control of MPPT algorithm for the PV power system are developed by Matlab/Simulink, SimPowerSystems and Matlab/Stateflow.

Database Construction to Compute Representative Model of Load Power Factor in Bulk Power System (대규모 전력계통의 부하역률 대표모델 산정을 위한 데이터베이스 구축)

  • Cho, Jong-Man;Lee, Hyo-Sang;Lee, Jung-He;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.83-89
    • /
    • 2004
  • The importance of the Load Power Factor(LPF) management is newly noticed from the voltage management and operation of the power system due to the rapidly increasing reactive power consumed. Therefore, this paper proposes the regional, seasonal and hourly Representative Model of Load Power Factor(RMLPF) considering load characteristics of all 154/22.9[kV] substations. The RMLPF is used to present a precision improvement of power system analysis and security. Computation of representative model of load utilizes the average flow method based on moving average method. The Energy Management System(EMS) data are used as the source to assess the load power factor.

The Effect of Geomagnetically Induced Current(GIC) on the Domestic Power Grids (국내 전력망에 대한 지자기 유도전류의 영향)

  • Shim, Haesup;Jeon, Taehyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.56-61
    • /
    • 2012
  • There have been a lot of reports about the effects of geomagnetically induced current(GIC) on the power grids. However there has been little domestic efforts made in this relatively urgent area which include academic research or risk assessments on GIC. There still exist a claim that domestic power grids might be in the safe state from GIC since our geomagnetic latitude is low and our power grid is relatively small scale. However it has been already demonstrated that GIC has an effect on power grids located at all latitudes. In this study, we have reviewed the transpiratory principle of the GIC, case studies of the major damage in various regions and we have calculated the GIC that can occur in domestic power grids. This paper presents some of the fundamental information about the risk assessment of domestic power grids from GIC although more thorough investigation should be made to ensure the safe operation of nationwide electric power infrastructure.

A Study on Power Flow Control of UPFC by Series and Shunt Voltage Source Model (직.병렬전압원 모델에 의한 UPFC 전력조류제어에 관한 연구)

  • 정인학;김경신;정재길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.21-30
    • /
    • 2001
  • In this paper, in the power system having UPFC(Unified Power Flow Controller) Power flow of certain line is controlled to desired value also power flow analysis algorithm is reposed considering power flow constraints which is capable of analysis power flow of all system. This algorithm is applied to controlling line-overloading problems and the method of is prosed. By applying this algorithm to controlling line-over loading the method of controlling UPFC is proposed and the effectiveness of controlling UPFC is proposed and the effectiveness of controlling UPFC is verified through the research of practical system. Also, the equation to set up an initial value of stories and shunt voltage source of UPFC is proposed for the effective power analysis.

  • PDF

Active Power Filter Type Uninterruptible Power Supply (UPS) (전력용 능동필터형 무정전 전원장치)

  • 김제홍;최재호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.100-105
    • /
    • 1998
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply (UPS) with the performance of active power filter which compensates the harmonics and reactive power. With only one power stage, it is working simultaneously as the AC/DC rectifier/battery charger and DC/AC inverter to the operation of battery charging or back-up power supplying. Therefore the operation of the proposed system can be divided into the modes, such as the active power filter mode and the battery back-up power mode. And a novel closed-loop control strategy is used to calculate the reference current. The performance of the proposed 5[kVA] system is verified by the simulation and experimental results.

  • PDF

A Comparative Study on the Bus Voltage Control Effect of STATCOM and UPFC in Power Flow Analysis of Power Systems (전력계통의 조류해석에서 STATCOM과 UPFC의 모선전압 제어효과에 대한 비교연구)

  • 김덕영;국경수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.41-45
    • /
    • 2001
  • This paper presents an comparative study on the effect of STATCOM and UPFC to power flow analysis of power systems. The effect of STATCOM can be analyzed with PSS/E program which is generally used in power system analysis, while UPFC model for power flow analysis is not provided yet. Thus, UPFC is equivalently represented as a synchronous condenser and load, while the active and reactive power of the specific transmission line and the voltage of the bus is controlled appropriately. This procedure is implemented by IPLAN which is an external macro program of PSS/E. The simulation results show that UPFC is more effective to control the bus voltage than STATCOM, because UPFC can control not only the bus voltage where the parallel inverter is installed but also the active and reactive power flow in the transmission line where the series inverter is installed.

  • PDF

A Study on High Precision and High Stability Digital Magnet Power Supply Using Second Order Delta-Sigma modulation (2차 델타 시그마 변조기법을 이용한 고 정밀 및 고 안정 디지털 전자석 전원 장치에 관한 연구)

  • Kim, Kum-Su;Jang, Kil-Jin;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.69-80
    • /
    • 2015
  • This paper is writing about developing magnet power supply. It is very important for power supply to obtain output current in high precision and high stability. As a switching noise and a power noise are the cause of disrupting the stability of output current, to remove these at the front end, low pass filter with 300Hz cutoff frequency is designed and placed. And also to minimize switching noise of the current into magnet and to stop abrupt fluctuations, output filter should be designed, when doing this, we design it by considering load has high value inductance. As power supply demands the stability of less than 5ppm, high precision 24bit(300nV/bit) analog digital converter is needed. As resolving power of 24bit(300nV/bit) analog digital converter is high, it is also very important to design the input stage of analog digital converter. To remove input noise, 4th order low pass filter is composed. Due to the limitation of clock, to minimize quantization error between 15bit DPWM and output of ADC having 24bit resolving power, ${\Sigma}-{\Delta}$ modulation is used and bit contracted DPWM is constituted. And before implementing, to maximize efficiency, simulink is used.