• Title/Summary/Keyword: identical

Search Result 5,183, Processing Time 0.037 seconds

Mechanically Modulated Nonlinear Digital Microactuators for Purified Digital Stroke and Nano-Precision Actuation (기계적 비선형 변조기를 이용한 디지털 구동의 안정화와 나노 구동정도 구현을 위한 디지털 마이크로액추에이터)

  • 이원철;진영현;조영호
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1990-1996
    • /
    • 2004
  • This paper presents a nonlinearly modulated digital actuator (NMDA) for producing nano-precision digital stroke. The NMDA, composed of a digital microactuator and a nonlinear micromechanical modulator, purifies the stroke of the digital actuator in order to generate the high-precision displacement output required for nano-positioning devices. The function and concept of the nonlinear micromechanical modulator are equivalent to those of the nonlinear electrical limiters. The linear and nonlinear modulators, having an identical input and output strokes of 15.2${\mu}{\textrm}{m}$ and 5.4${\mu}{\textrm}{m}$, are designed, fabricated and tested, respectively. The linear and nonlinear modulators are linked to identical digital actuators in order to compare the characteristics of the linearly modulated microactuator (LMDA) and NMDA. In addition, an identical linear modulator is attached to the output ports of LMDA and NMDA. The NMDA shows the repeatability of 12.3$\pm$2.9nm, superior to that of 27.8$\pm$2.9nm achieved by LMDA. When the identical linear modulator is connected to LMDA and NMDA, the final modulated output from NMDA shows the repeatability of 10.3$\pm$7.2nm, superior to that of 15.7$\pm$7.7nm from LMDA. We experimentally verify the displacement purifying capability of the nonlinear mechanical modulator, applicable to nano-precision positioning devices and systems.

Production of Identical Multiplets from Deep-Frozen Embryos (동결보존배를 이용한 일란성 다태생산에 관한 연구)

  • Shin Sang-Tae
    • Journal of Veterinary Clinics
    • /
    • v.10 no.2
    • /
    • pp.243-249
    • /
    • 1993
  • Although plenty of experiments for production of genetically identical twins have been reported, most of these reports were focused on microsurgical bisection of morula stage embryos, and little research has been performed for the production with frozen emb교os. The objective of these experiments were to assess the in vitro and in vitro developmental potential of blastomeres isolated from frozen-thawed 4-cell and 8-cell mouse embryos and to produce the identical multiplets from those embryos. The percentages of isolated 1/4, 2/4, 4/4, (control), 1/8, 2/8, 3/8, 4/8 and 8/8(control) blastomeres of 4-cell and 8-cell mouse emb교os which developed to normal blastocyst were 38.7%, 73.6%, 96.2(control), 15.1%, 40.1%, 65.9%, 88.3%, and 98.5%(control), respectively. The percentages of isolated 1/4, 2/4, 4/4(control), 1/8, 2/8, 3/8, 4/8 and 8/8(control) blastomeres of frozen-thawed 4-cell and 8-cell mouse embryos which developed to normal blastocyst were 35.6%, 68.5%, 100.0%(control), 16.1%, 50.6%, 71.7%, 90.9% and 100.0%(control), respectively. Normal 26 pups were obtained by transfer of 240 blastocyts developed 1, on 1/4 to 8/8 blastomeres. Those 26 pups obtained, 4 identical twins were produced from 2/4, 2/8, 3/8 and 4/8 blastomeres.

  • PDF

Frame Rate Up-Conversion Considering The Direction and Magnitude of Identical Motion Vectors (동일한 움직임 벡터들의 방향과 크기를 고려한 프레임율 증가기법)

  • Park, Jonggeun;Jeong, Jechang
    • Journal of Broadcast Engineering
    • /
    • v.20 no.6
    • /
    • pp.880-887
    • /
    • 2015
  • In this paper, frame rate up conversion (FRUC) algorithm considering the direction and magnitude of identical motion vectors is proposed. extended bilateral motion estimation (EBME) has higher complexity than bilateral motion estimation (BME). By using average magnitude of motion vector with x and y direction respectively, dynamic frame and static frame are decided. We reduce complexity to decide EBME. also, After we compare the direction and magnitude of identical motion vectors, We reduce complexity to decide motion vector smoothing(MVS). Experimental results show that this proposed algorithm has fast computation and better peak singnal to noise ratio(PSNR) results compared with EBME.

Some Special Cases of a Continuous Time-Cost Tradeoff Problem with Multiple Milestones under a Chain Precedence Graph

  • Choi, Byung-Cheon;Chung, Jibok
    • Management Science and Financial Engineering
    • /
    • v.22 no.1
    • /
    • pp.5-12
    • /
    • 2016
  • We consider a time-cost tradeoff problem with multiple milestones under a chain precedence graph. In the problem, some penalty occurs unless a milestone is completed before its appointed date. This can be avoided through compressing the processing time of the jobs with additional costs. We describe the compression cost as the convex or the concave function. The objective is to minimize the sum of the total penalty cost and the total compression cost. It has been known that the problems with the concave and the convex cost functions for the compression are NP-hard and polynomially solvable, respectively. Thus, we consider the special cases such that the cost functions or maximal compression amounts of each job are identical. When the cost functions are convex, we show that the problem with the identical costs functions can be solved in strongly polynomial time. When the cost functions are concave, we show that the problem remains NP-hard even if the cost functions are identical, and develop the strongly polynomial approach for the case with the identical maximal compression amounts.

Connection of Myofascial Release to Cupping (근막이완술과 부항의 접목)

  • Baek Seung-Ryong;Chung Hyung-Kuk;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.8 no.1
    • /
    • pp.109-119
    • /
    • 1996
  • Although the physical therapy of both East and West has been based on an identical philosophy, they have had their own therapy with difference in its form and pattern. In general, cupping is used to diagnose and treat viscera by means of acupuncture point, and myofascial release is also used for both diagnosis and orthopedic treatment on the basis of trigger point and myofascial however, when they have a lot of identical facts such as using both mental and physical aspects of human beings for treatment, keeping nervous action balanced, and recovering depressed nervous functions and relieving the pain. In addition. their identical fact includes that they tend to treat patients by using symptoms and reaction shown in their skin, and that both East and West try to consider myofascia as an integrated totality and as a unified body of organic functions with correlations. Among the principles of myofascial release, recently, it has been very identical that stimulus given to the skin results in synapse to sympathetic nerve through dosal horn cell has an effect on viscera, and that cupping is sued for diagnosis and treatment of viscera. It is required, therefore, to continue to carry out studying on this field.

  • PDF

Efficient Vibration Control Approach of Two Identical Adjacent Structures (동일한 인접구조물의 효율적 진동제어방안)

  • Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.56-63
    • /
    • 2014
  • This study proposes a new control approach for efficient vibration suppression of two identical adjacent structures. The conventional control approach of two adjacent structures is to interconnect the two structures with passive, semi-active or active control devices. However, when the two adjacent structures are identical to each other, their dynamical behaviors such as frequency and damping properties are also the same. In this case, the interconnected control devices cannot exhibit the dissipative control forces on the both structures as expected since the relative displacements and velocities of the devices become close to zero. In other words, the interconnection method does not work for the twin structures as enough as expected. In order to solve this problem, we propose several new control approaches to effectively and efficiently reduce the identically-fluctuating responses of the adjacent structures with minimum control efforts. In order to demonstrate the proposed control systems, the proposed several control systems are optimally designed and their control performances are compared with that of the conventional optimal control system where each TMD(tuned mass damper) is installed in each structure for independent control purpose. The simulated results show that one of the proposed control systems(System 04) is able to guarantee enhanced control performance compared with the conventional system.

Feasibility study on a stabilization method based on full spectrum reallocation for spectra having non-identical momentum features

  • Kilyoung Ko ;Wonku Kim ;Hyunwoong Choi;Gyuseong Cho
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2432-2437
    • /
    • 2023
  • Methodology for suppressing or recovering the distorted spectra, which may occur due to mutual non-uniformity and nonlinear response when a multi-detector is simultaneously operated for gamma spectroscopy, is presented with respect to its applicability to stabilization of spectra having the non-identical feature using modified full spectrum reallocation method. The modified full-spectrum reallocation method is extended to provide multiple coefficients that describe the gain drift for multi-division of the spectrum and they were incorporated into an optimization process utilizing a random sampling algorithm. Significant performance improvements were observed with the use of multiple coefficients for solving partial peak dislocation. In this study, our achievements to confirm the stabilization of spectrum having differences in moments and modify the full spectrum reallocation method provide the feasibility of the method and ways to minimize the implication of the non-linear responses normally associated with inherent characteristics of the detector system. We believe that this study will not only simplify the calibration process by using an identical response curve but will also contribute to simplifying data pre-processing for various studies as all spectra can be stabilized with identical channel widths and numbers.

Design of System for Avoiding upload of Identical-file using SA Hash Algorithm (SA 해쉬 알고리즘을 이용한 중복파일 업로드 방지 시스템 설계)

  • Hwang, Sung-Min;Kim, Seog-Gyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.10
    • /
    • pp.81-89
    • /
    • 2014
  • In this paper, we propose SA hash algorithm to avoid upload identical files and design server system using proposed SA hash algorithm. Client to want to upload file examines the value of SA hash and if the same file is found in server system client use the existing file without upload. SA hash algorithm which is able to examine the identical-file divides original file into blocks of n bits. Original file's mod i bit and output hash value's i bit is calculated with XOR operation. It is SA hash algorithm's main routine to repeat the calculation with XOR until the end of original file. Using SA hash algorithm which is more efficient than MD5, SHA-1 and SHA-2, we can design server system to avoid uploading identical file and save storage capacity and upload-time of server system.

The Types of Color Coordination and Their Characteristics In Contemporary Women′s Fashion (현대 여성 패션에 나타난 색채 코디네이션의 유형과 유형별 특성 분석)

  • Kwon Hae-Sook;Shim Eun-A
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.6 no.3
    • /
    • pp.139-152
    • /
    • 2004
  • The main objective of this research is to investigate the color coordination types and their characteristics of contemporary female fashion by reviewing 'pre-a-porter Collections' of four collections (i.e., cities) - Paris, Milan, New York, London - from the periods of 2000 S/S to 2002/3 A/W. Through the review of various books and articles written on the subject, the color coordination types and their characteristics were categorized and defined. The data was collected by reviewing 'pre-a-porter Collections' magazine and total 4,269 observations were made. These in turn were categorized into eight color coordination and three color tone categories through the content analysis. Frequency analysis was used to analyse the data. The findings are as follows; First of all, there were 8 observable color coordination categories in contemporary women's fashion. The most used color coordination was chromatic & achromatic color coordination. It was followed by chromatic identical, and then by achromatic identical color coordination. These three color coordinations were the majority, comprizing 73.4% of the total. The rest were in the order of complementary, gradation, similarity, accent. And the most used tone type was contrasting tone and followed by similar and identical. Next, the analysis of each coordination categories shows that; The chromatic identical coordination focused on presenting its own unity or break it using the contrasting color tone. Meanwhile, the achromatic identical coordination project a clean and strong feeling through black and white combination or a subtle feeling through the different material combination. The chromatic & achromatic coordination showed strong colors and contrasting tones of clear and bright colors. Meanwhile, the characteristics of complementary coordinations are that these coordinations seem to free the colors and show the subtle changes in tones very clearly. The gradation coordination was used to create a cool and lively feeling. Next, the similarity coordination seems to create feminine and warm feeling by taking advantage of similar color feelings, often through the use of warm to warm, cool to cool color matching. Lastly, the accent coordination, through the use of contrasting tones emphasizes the differences in colors, while separation coordination mostly uses black and white on various color coordinations.

  • PDF

Prediction of Post-Treatment Outcome of Pathologic Voice Using Voice Synthesis (음성합성을 이용한 병적 음성의 치료 결과에 대한 예측)

  • 이주환;최홍식;김영호;김한수;최현승;김광문
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.14 no.1
    • /
    • pp.30-39
    • /
    • 2003
  • Background and Objectives : Patients with pathologic voice often concern about recovery of voice after surgery. In our investigation, we give controlled values of three parameters of voice synthesis program of Dr. Speech Science. such as jitter, shimmer, and NNE(normalized noise energy) which characterize someone's voice from others and deviced a method to synthesize the predicted voice after performing operation. Subjects and Method : Values of vocal jitter, vocal shimmer, and glottal noise were measured with voices of 10 vocal cord Paralysis and 10 vocal Polyp Patients 1 week Prior to and 1 month after the surgery. With Dr. Speech science voice synthesis program we synthesized 'ae' vowel which is closely identical to preoperative and post-operative voice of the patients by controlling the values of jitter, shimmer, and glottal noise. then we analyzed the synthesized voices and compared with pre and post-operative voice. Results : 1) After inputting the preoperative and corrected values of jitter, shimmer, and glottal noise into the voice synthesis Program, voices identical to vocal Polyp Patients' Pre- and Postoperative voices withiin statistical significance were synthesized 2) After elimination of synergistic effects between three paramenter, we were able to synthesize voice identical to vocal paralysis patients' preoperative voices. 3) After inputting only slightly increased jitter, shimmer into the synthesis program, we were able to synthesize voice identical to vocal cord paralysis patients' postoperative voices. Conclusion : Voices synthesized with Dr. Speech science program were identical to patients' actual pre and postoperative voice, and clinicians will be able to give the patients more information and thus increased patients cooperability can be expected.

  • PDF