• Title/Summary/Keyword: iPower

Search Result 5,721, Processing Time 0.044 seconds

Virtual Power Plant System using OpenADR2.0 and TASE.2 for Integrated Management of Distributed Energy Resource (분산자원 통합 관리를 위한 OpenADR2.0 및 TASE.2 기반 가상발전소 시스템)

  • Seo, Jong Kwan;Lee, Tae Il;Lee, Whee Sung;Park, Jeom Bae
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.311-318
    • /
    • 2020
  • A virtual power plant is a kind of software power plant that enables participation in power operation by integrally managing individual distributed resources. This paper proposes a common information communication architecture based on the TASE.2 standard and the OpenADR2.0 standard to operate a virtual power plant as a single power system. ESS is designed TASE.2 SBO devices that related objects are mapped to OpenADR2.0 services and composed as a single sequence type. Through simulation verification, it conforms data exchange and operation based on both standards.

A Novel Simple Method to Abstract the Entire Parameters of the Solar Cell

  • Park, Minwon;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.86-91
    • /
    • 2004
  • PV power generation, which directly converts solar radiation into electricity, contains numerous significant advantages. It is inexhaustible and pollution-free, silent, contains no rotating parts, and has size-independent electricity conversion efficiency. The positive environmental effect of photovoltaics is that it replaces the more polluting methods of electricity generation or that it provides electricity where none was available before. This paper highlights a novel simple method to abstract the entire parameters of the solar cell. In development, design and operation of PV power generation systems, a technique for constructing V-I curves under different levels of solar irradiance and cell temperature conditions using basic characteristic values of the PV module is required. Everyone who has performed manual acquisition and analysis of solar cell I versus V data would agree that the job is tedious and time-consuming. A better alternative is to use an automated curve tracer to print out the I versus V curves and compute the four major parameters; $V_{oc}$, $I_{sc}$, FF, and . Generally, the V-I curve tracer indicates only the commonly used solar cell parameters. However, with the conventional V-I curve tracer it is almost impossible to abstract the more detailed parameters of the solar cell; A, $R_{s}$ and $R_{sh}$ , which satisfies the user, who aims at the analysis of the development of the PV power generation system, that being advanced simulation. In this paper, the proposed method provides us with satisfactory results to enable us to abstract the detailed parameters of the solar cell; A, $R_s$ and $R_{sh}$.>.

Development of the Web based Power Quality Monitoring System (웹 기반의 전기품질 감시장치 개발)

  • Nam, Kee-Young;Kim, Ho-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.28-30
    • /
    • 2002
  • The increasing application of electronic equipment has heightened the interest in power quality in recent years because there are economic impacts on utilities, customers, and suppliers of load equipment. The power quality would impose result in severe damage on many industrial customers. As having been supplied many kinds of electronic devices such as computer and communication equipment, automation equipment and various kinds of control devices etc., it comes to be more and more difficult to maintain the clean power quality. According to the restructuring in electricity industry the power quality may be treated as goods as contract terms and regulation elements between power supplier and consumer in the near future. Under the above environment, the power quality should be monitored for all day long with appropriate devices which is possible to measure and record the associated power quality data to prove each responsibility for the impacts when disputes arise due to power quality problems power quality problems are occurred. In this paper the authors propose some functions to be considered and system configuration to monitor the associated power quality elements in developing the web based power quality monitoring system.

  • PDF

Generator Testing and Model Validation for Thermal Plant (전력계통 안정성 향상을 위한 발전기 제어계 특성시험 및 모델링)

  • Cha, S.T.;Kim, Y.H.;Oh, S.I.;Choi, J.H.;Shin, J.H.;Shim, E.B.;Kwak, N.H.;Son, H.I.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.473-474
    • /
    • 2007
  • The Jeju power grid experienced several major power disturbances over the last decade. The postmortem studies of the incidents indicated that some of the generating units did not respond as predicted by system analysis & studies. Consequently, the Korean Power Exchange (KPX) mandated that all units (generators, excitation, governor and turbine systems) in the Korean network greater than or equal to 20MVA be tested to verify the generator reactive power limits as well as the dynamic model data being used for system studies. This paper presents field experiences of the authors in testing and modeling of steam turbines and their associated governors during the generator and model validation.

  • PDF

The Fuzzy Power Function of a Test (검정에 관한 퍼지 검정력 함수의 성질)

  • Gang, Man-Gi;Jeong, Ji-Yeong;Park, Yeong-Rye;Choe, Gyu-Tak
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.11a
    • /
    • pp.183-186
    • /
    • 2007
  • We introduction some properties for fuzzy power function of performance of a test. First we define fuzzy type I error and type II error for the probability of the two types of error. And we show that an fuzzy error probability of one kind can only be reduced at cost of increasing the other fuzzy error probability.

  • PDF

Analysis of Insulation Diagnostic Test for High Voltage Motor(I) (고압전동기 절연진단 해석(I))

  • Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2104-2106
    • /
    • 1999
  • The insulation diagnostic tests was performed at local thermal power plants high voltage motor. The insulation diagnostic tests include measurements of insulation resistance, polarization index, AC current, $tan{\delta}$, partial discharges. This paper describes the difference of insulation characteristics for high voltage motor makers.

  • PDF

Design of Full-Order Observer-based Sliding Mode Controller for Power System Stabilizer : Part I (전력계통안정기를 위한 전-차수 관측기에 기준한 슬라이딩 모드 제어기 설계 : Part I)

  • Lee, Sang-Seung;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1156-1158
    • /
    • 1997
  • This paper presents the proposed full-order observer-based sliding mode power system stabilizer(FOOSMPSS) for finding unmeasurable state variables(torque angle, quadratic-axis transient voltage, exciter output voltage, voltage regulator output voltage and output voltage) by measuring angular velocity. The simulation results is shown by the comparison of the FOOPSS with the proposed FOOSMPSS.

  • PDF

Class E Amplifier in Push-Pull Configuration

  • Ma, Sui-Wah;Yam, Yu-On;Wong, Hei
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.941-944
    • /
    • 2000
  • This paper proposes, for the first time, the design of class I pull-push power amplifier. With the new design, the output power is increased by four times when compared to conventional single-end class I connection amplifier with the same supply voltage. The performance of the proposed amplifier is verified by with a 100-kHz power amplifier constructed using general-purpose NPN transistors.

  • PDF

Development of the 154kV, 800 MVA Cryogenic Power Transimission System (I) - Disign of Cryogenic Resistive Cable - (154kV, 800MVA급 극저온 송전시스템 개발(I)-극저온 저항 케이블 설계)

  • 류강식;안우희;홍원표
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.661-672
    • /
    • 1992
  • In this study, the 154kV 800 MVA cryogenic resistive cable and its power transmission system were designed and built in a purpose of suggestion a plan using high density and large power transportation systems in practice to solve the recent increase in demands of electrical energy. Cryogenic resistive cable uses the benefits of increasing the conductivity of matals in LNS12T. We describe the details of designs of cryogenic resistive cable consisting of main part in this system.

A Novel Parameter Extraction Method for the Solar Cell Model (새로운 태양전지 모델의 파라미터 추출법)

  • Kim, Wook;Kim, Sang-Hyun;Lee, Jong-Hak;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.372-378
    • /
    • 2009
  • With the increase in capacity of photovoltaic generation systems, studies are being actively conducted to improve system efficiency. In order to develop the high performance photovoltaic power system it is required to understand the physical characteristics of the solar cell. However, solar cell models have a non-linear form with many parameters entangled and conventional methods suggested to extract the parameters of the solar cell model require some kind of assumptions, which accompanies the calculation errors, thereby lowering the accuracy of the model. Therefore, in this paper a novel method is proposed to calculate the ideality factor and reverse saturation current of the solar cell from the I-V curve measured and announced by solar cell manufacturers, derive the ideal I-V curve, and then extract the series and shunt resistances value from the difference between the ideal and measured I-V curve. Also, validity of the proposed method is demonstrated by calculating the correlation between I-V curve based on modeling parameters and I-V curve actually measured through least squares method.