• 제목/요약/키워드: hysteresis performance

검색결과 449건 처리시간 0.019초

Experimental investigations of the seismic performance of bridge piers with rounded rectangular cross-sections

  • Shao, Guangqiang;Jiang, Lizhong;Chouw, Nawawi
    • Earthquakes and Structures
    • /
    • 제7권4호
    • /
    • pp.463-484
    • /
    • 2014
  • Solid piers with a rounded rectangular cross-section are widely used in railway bridges for high-speed trains in China. Compared to highway bridge piers, these railway bridge piers have a larger crosssection and less steel reinforcement. Existing material models cannot accurately predict the seismic behavior of this kind of railway bridge piers. This is because only a few parameters, such as axial load, longitudinal and transverse reinforcement, are taken into account. To enable a better understanding of the seismic behavior of this type of bridge pier, a simultaneous influence of the various parameters, i.e. ratio of height to thickness, axial load to concrete compressive strength ratio and longitudinal to transverse reinforcements, on the failure characteristics, hysteresis, skeleton curves, and displacement ductility were investigated. In total, nine model piers were tested under cyclic loading. The hysteretic response obtained from the experiments is compared with that obtained from numerical studies using existing material models. The experimental data shows that the hysteresis curves have significantly pinched characteristics that are associated with small longitudinal reinforcement ratios. The displacement ductility reduces with an increase in ratio of axial load to concrete compressive strength and longitudinal reinforcement ratio. The experimental results are largely in agreement with the numerical results obtained using Chang-Mander concrete model.

슬라이딩 모드와 Neural network 제어기를 이용한 Buck type DC-DC 컨버터의 출력전압제어 (The Output Voltage Control of Buck Type DC-DC Converter Using Sliding Mode and Neural Controller)

  • 황계호;남승식;김동희;배상준
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.95-100
    • /
    • 2004
  • 최근, 비선형시스템인 DC-DC 컨버터의 출력전압제어를 위해서 많은 제어방법들이 연구되고 있으며, 본 논문은 Buck type DC-DC 컨버터에 슬라이딩 모드 제어기와 뉴럴 네트워크 제어기를 이용한 제어 알고리즘을 제시하였고, 또한 컨버터의 이론해석을 통한 이론특성과 Psim을 이용한 시뮬레이션특성, DSP(TMS320C32)를 이용한 실험특성을 비교 검토하여 제안한 방법의 유용성을 입증하였다. 기존의 히스테리시스 제어기를 이용한 제어방법과 제안한 슬라이딩 모드 제어기와 뉴럴 네트워크 제어기를 이용한 제어방법과 비교한 결과 제안한 제어기가 우수한 특성을 얻었으며, 향후, 다른 전력변환장치에 유용하게 적용될 것으로 생각된다.

Improving cyclic behavior of multi-level pipe damper using infill or slit diaphragm inside inner pipe

  • Zahrai, Seyed Mehdi;Cheraghi, Abdullah
    • Structural Engineering and Mechanics
    • /
    • 제64권2호
    • /
    • pp.195-204
    • /
    • 2017
  • Analytical and experimental studies of the innovative pipe in pipe damper have been recently investigated by the authors. In this paper, by adding lead or zinc infill or slit diaphragm inside the inner pipe, it is tried to increase the equivalent viscous damping ratio improving the cyclic performance of the recently proposed multi-level control system. The damper consists of three main parts including the outer pipe, inner pipe and added complementary damping part. At first plastic deformations of the external pipe, then the internal pipe and particularly the added core and friction between them make the excellent multi-level damper act as an improved energy dissipation system. Several kinds of added lead or zinc infill and also different shapes of slit diaphragms are modeled inside the inner pipe and their effectiveness on hysteresis curves are investigated with nonlinear static analyses using finite element method by ABAQUS software. Results show that adding lead infill has no major effect on the damper stiffness while zinc infill and slit diaphragm increase damper stiffness sharply up to more than 10 times depending on the plate thickness and pipe diameter. Besides, metal infill increases the viscous damping ratio of dual damper ranging 6-9%. In addition, obtained hysteresis curves show that the multi-level control system as expected can reliably dissipate energy in different imposed energy levels.

Two Vector Based Direct Power Control of AC/DC Grid Connected Converters Using a Constant Switching Frequency

  • Mehdi, Adel;Reama, Abdellatif;Benalla, Hocine
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1363-1371
    • /
    • 2017
  • In this paper, an improved Direct Power Control (DPC) algorithm is presented for grid connected three phase PWM rectifiers. The new DPC approach is based on two main tasks. First the optimization of the look-up table, which is well-known in conventional DPC, is outlined for selecting the optimum converter output voltage vectors. Secondly a very simple and effective method is used to directly calculate their duty cycles from the power errors. Therefore, the measured active and reactive powers are made to track their references using hysteresis controllers. Then two vectors are selected and applied during one control cycle to minimize both the active and reactive power ripples. The main advantages of this method are that there is no need of linear current controllers, coordinates transformations or modulators. In addition, the control strategy is able to operate at constant switching frequencies to ease the design of the power converter and the AC harmonic filter. The control exhibits a good steady state performance and improves the dynamic response without any overshoot in the line current. Theoretical principles of the proposed method are discussed. Both simulation and experimental results are presented to verify the performance and effectiveness of this control scheme.

원전 EQS 면진장치의 성능개선을 위한 연구 (Study on the Performance Improvement of an EQS Device Applied Nuclear Power Plant)

  • 이유인;이유진;이홍표;조명석;지용수;백준호
    • 한국지진공학회논문집
    • /
    • 제19권1호
    • /
    • pp.13-19
    • /
    • 2015
  • This paper presents the performance improvement of an EQS (Eradic Quake System) device applied to a nuclear power plant. For the nuclear facility, the EQS device needs to be ensured to have high quality, flexibility of design and reliability. To improve the reliability of the design, the hysteresis of the device must be exactly predicted. The friction coefficient of PTFE (PolyTetraFluoroEthylene) and the stiffness of the MER-Spring are considered as the factors influencing the hysteresis curve. In this paper, those factors are analysed to predict the behavior of the device and to improve the equipment of the EQS device. The results of the improved EQS device have been verified via a tests to be comparable with the predicted results. The estimation results indicate that considering those factors is more appropriate than the results of the previous design and method.

Studies on restoring force model of concrete filled steel tubular laced column to composite box-beam connections

  • Huang, Zhi;Jiang, Li-Zhong;Zhou, Wang-Bao;Chen, Shan
    • Steel and Composite Structures
    • /
    • 제22권6호
    • /
    • pp.1217-1238
    • /
    • 2016
  • Mega composite structure systems have been widely used in high rise buildings in China. Compared to other structures, this type of composite structure systems has a larger cross-section with less weight. Concrete filled steel tubular (CFST) laced column to box-beam connections are gaining popularity, in particular for the mega composite structure system in high rise buildings. To enable a better understanding of the destruction characteristics and aseismic performance of these connections, three different connection types of specimens including single-limb bracing, cross bracing and diaphragms for core area of connections were tested under low cyclic and reciprocating loading. Hysteresis curves and skeleton curves were obtained from cyclic loading tests under axial loading. Based on these tested curves, a new trilinear hysteretic restoring force model considering rigidity degradation is proposed for CFST laced column to box-beam connections in a mega composite structure system, including a trilinear skeleton model based on calculation, law of stiffness degradation and hysteresis rules. The trilinear hysteretic restoring force model is compared with the experimental results. The experimental data shows that the new hysteretic restoring force model tallies with the test curves well and can be referenced for elastic-plastic seismic analysis of CFST laced column to composite box-beam connection in a mega composite structure system.

Structural health monitoring for pinching structures via hysteretic mechanics models

  • Rabiepour, Mohammad;Zhou, Cong;Chase, James G.;Rodgers, Geoffrey W.;Xu, Chao
    • Structural Engineering and Mechanics
    • /
    • 제82권2호
    • /
    • pp.245-258
    • /
    • 2022
  • Many Structural Health Monitoring (SHM) methods have been proposed for structural damage diagnosis and prognosis. However, SHM for pinched hysteretic structures can be problematic due to the high level of nonlinearity. The model-free hysteresis loop analysis (HLA) has displayed notable robustness and accuracy in identifying damage for full-scaled and scaled test buildings. In this paper, the performance of HLA is compared with seven other SHM methods in identifying lateral elastic stiffness for a six-story numerical building with highly nonlinear pinching behavior. Two successive earthquakes are employed to compare the accuracy and consistency of methods within and between events. Robustness is assessed across sampling rates 50-1000 Hz in noise-free condition and then assessed with 10% root mean square (RMS) noise added to responses at 250 Hz sampling rate. Results confirm HLA is the most robust method to sampling rate and noise. HLA preserves high accuracy even when the sampling rate drops to 50 Hz, where the performance of other methods deteriorates considerably. In noisy conditions, the maximum absolute estimation error is less than 4% for HLA. The overall results show HLA has high robustness and accuracy for an extremely nonlinear, but realistic case compared to a range of leading and recent model-based and model-free methods.

IGBT 인버터-유도전동기 구동시스템을 위한 전류제어기의 특성 연구 (A Study on Performance of Curent Regulations for IGBT Inverter-Fed Induction Motor Drive Systems)

  • 이동춘;김영렬;설승기
    • 대한전기학회논문지
    • /
    • 제43권2호
    • /
    • pp.215-225
    • /
    • 1994
  • In this paper, a performance evaluation of different current regulators for induction motor drive systems fed by IGBT inverter is presented. The twoparts of current regulation are considered : current error compensation part, voltage modulation part. The characteristics of hysteresis, synchronous PI, decoupled PI, predictive, deadbeat and stage feedback controllers are analyzed and the steady-state performances and transient responses of current regulation are well compared through the simulation and experimental results.

  • PDF

Mechanical performance analysis of an electromagnetic friction pendulum system based on Maxwell's principle

  • Mao Weikang;Li Xiaodong;Chen Enliang
    • Earthquakes and Structures
    • /
    • 제27권2호
    • /
    • pp.143-154
    • /
    • 2024
  • Friction pendulums typically suffer from poor uplift-restraining. To improve the uplift-restraining and enhance the energy dissipation capacity, this article proposed a composite isolation device based on electromagnetic forces. The device was constructed based on a remote control system to achieve semi-active control of the composite isolation device. This article introduces the theory and design of an electromagnetic chuck-friction pendulum system (ECFPS) and derives the theoretical equation for the ECFPS based on Maxwell's electromagnetic attraction equation to construct the proposed model. By conducting 1:3 scale tests on the electromagnetic device, the gaps between the practical, theoretical, and simulation results were analyzed, and the accuracy and effectiveness of the theoretical equation for the ECFPS were investigated. The hysteresis and uplift-restraining performance of ECFPS were analyzed by adjusting the displacement amplitude, vertical load, and input current of the simulation model. The data obtained from the scale test were consistent with the theoretical and simulated data. Notably, the hysteresis area of the ECFPS was 35.11% larger than that of a conventional friction pendulum. Lastly, a six-story planar frame structure was established through SAP2000 for a time history analysis. The isolation performances of ECFPS and FPS were compared. The results revealed that, under horizontal seismic action, the horizontal seismic response of the bottom layer of the ECFPS isolation structure is greater than that of the FPS, the horizontal vibration response of the top layer of the ECFPS isolation structure is smaller than that of the FPS, and the axial force at the bottom of the columns of the ECFPS isolation structure is smaller than that of the FPS isolation structure. Therefore, the reliable uplift-restraining performance is facilitated by the electromagnetic force generated by the device.

산림유역의 부유토사 동태 해석을 위한 이력현상 지수의 적용성 평가 (Assessing the Applicability of Hysteresis Indices for the Interpretation of Suspended Sediment Dynamics in a Forested Catchment)

  • 김기대;장수진;남수연;이재욱;김석우
    • 한국환경생태학회지
    • /
    • 제38권2호
    • /
    • pp.178-188
    • /
    • 2024
  • 산림유역의 부유토사 동태는 토지이용 변화, 산림사업, 산불, 산사태 등의 인위적 또는 자연적 교란에 따라서 다변화될 수 있다. 이러한 측면에서 산림유역의 부유토사 동태를 이해하는 것은 효과적인 수질 관리 대책을 수립하는 데에 중요하다. 이 연구는 부유토사 동태를 해석하기 위한 체계적인 조사 방법을 제안하고자 관측된 유출량-탁도 자료를 토대로 2가지의 이력현상 지수 산정 방법(Lawler의 방법과 Lloyd의 방법)과 5가지 추출 간격(50, 25, 10, 5, 1 퍼센타일)을 고려한 10개 산정기법의 적용성과 성능을 평가하였다. 그 결과, 1 퍼센타일의 추출 간격을 활용한 Lloyd의 방법이 분석 가능한 유출 사상이 가장 많았으며, 성능 역시 가장 뛰어난 것으로 확인되었다. 이 연구의 결과는 이력현상 지수를 활용함으로써 유출량과 부유토사의 이력현상을 정량화할 수 있을 뿐만 아니라 부유토사 동태를 해석하는 데에 유용한 정보를 제공할 수 있음을 시사한다.