• Title/Summary/Keyword: hysteresis curves

Search Result 233, Processing Time 0.027 seconds

Experimental and analytical investigation on RC columns with distributed-steel bar

  • Ye, Mao;Pi, Yinpei;Ren, Min
    • Structural Engineering and Mechanics
    • /
    • v.47 no.6
    • /
    • pp.741-756
    • /
    • 2013
  • Distributed-Steel Bar Reinforced Concrete (DSBRC) columns, a new and innovative construction technique for composite steel and concrete material which can alleviate the difficulty in the arrangement of the stirrup in the column, were studied experimentally and analytically in this paper. In addition, an ordinary steel Reinforced Concrete (SRC) column was also tested for comparison purpose. The specimens were subjected to quasi-static load reversals to model the earthquake effect. The experimental results including the hysteresis curve, resistance recession, skeleton curves and ductility ratio of columns were obtained, which showed well resistant-seismic behavior for DSBRC column. Meanwhile a numerical three-dimensional nonlinear finite-element (FE) analysis on its mechanical behavior was also carried out. The numerically analyzed results were then compared to the experimental results for validation. The parametric studies and investigation about the effects of several critical factors on the seismic behavior of the DSBRC column were also conducted, which include axial compression ratios, steel ratio, concrete strength and yield strength of steel bar.

Domain Contribution in the Electric-field-induced Strain of PZT Ceramics

  • Tsurumi, Takaaki
    • The Korean Journal of Ceramics
    • /
    • v.7 no.1
    • /
    • pp.30-35
    • /
    • 2001
  • The contribution of the non-$180^{\circ}C$ domains to the electric-field-induced strains (EFI-strains) of PZT ceramics was evaluated by an XRD method and by an interferometric method. The XRD intensity ratio of 200 and 002 diffraction peaks of tetragonal PZT was measured under strong electric fields. The amount of the $90^{\circ}$ domain reorientation was evaluated and the strain due to the domain reorientation was calculated. It was confirmed that the EFI-strain of PZT ceramics was equal to the sum of the strain calculated from the d$_33$ constant determined by the resonance-antiresonance method and the strain due to the $90^{\circ}$ domain reorientation. The amount of the $90^{\circ}$domain reorientation has a linear relation with the c/a ratio in the "soft" PZT ceramics. A Mech-Zehnder interferometer was constructed to measure the EFI-strains vs. electric-field curves of PZT ceramics as a function of frequency. The EFI-strain vs. electric-field curve showed a hysteresis due to the effect of the non-$180^{\circ}$ domain reorientation when the applied voltage was high and its frequency was low. The apparent piezoelectric constant increased from the d$_33$ value determined by the resonance-antiresonance method with decreasing frequency. This deviation was attributed to the non-$180^{\circ}$ domain contribution.tribution.

  • PDF

A Study on the Fabrication $Na_0.5$$K_0.5$$NbO_3$ Volatile Material Thin Film by Pulsed Laser Deposition and he Confirmation of C-axis Orientation by X-ray Diffraction (PLD 기법에 의한 $Na_0.5$$K_0.5$$NbO_3$ 휘발성 물질의 박막 제작 및 XRD에 의한 c축 배향성 확인에 관한 연구)

  • 최원석;김장용;장철순;문병무
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.4
    • /
    • pp.269-273
    • /
    • 2001
  • W fabricated thin film using Na$_{0.5}$K$_{0.5}$NbO$_3$ volatile material by pulsed laser deposition (PLD) and studied characterization from EM, XRD, P-E. The density and scale of droplet, which is the defect of PLD, was investigated by SEM but large droplet was not found. The degree of assemble oriented C-axis measured with X-ray diffraction suggests that this film oriented C-axis achieved by $\theta$-2$\theta$ scan and rocking curves shows good self-assemble phenomenon, finally $\phi$-scan does that all of the four directions of the lattice in film equals to those of substrate. P-E hysteresis loop shows residual remnant polarization or saturation polarization value, but it is applicable to memories.ies.

  • PDF

The Passivation of GaAs Surface by Laser CVD

  • Sung, Yung-Kwon;Song, Jeong-Myeon;Moon, Byung-Moo;Rhie, Dong-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1242-1247
    • /
    • 2003
  • In order to passivate the GaAs surface, silicon-nitride films were fabricated by using laser CVD method. SiH$_4$ and NH$_3$ were used to obtain SiN films in the range of 100∼300$^{\circ}C$ on p-type (100) GaAs substrate. To determine interface characteristics of the metal-insulator-GaAs structure, electrical measurements were performed such as C-V curves and deep level transient spectroscopy (DLTS). The results show that the hysteresis was reduced and interface trap density was lowered to 1,012 ∼ 1,013 at 100 ∼ 200$^{\circ}C$. According to the study of surface leakage current, the passivated CaAs has less leakage current compared to non-passivated substrate.

Experimental and numerical study on innovative seismic T-Resisting Frame (TRF)

  • Ashtari, Payam;Sedigh, Helia Barzegar;Hamedi, Farzaneh
    • Structural Engineering and Mechanics
    • /
    • v.60 no.2
    • /
    • pp.251-269
    • /
    • 2016
  • In common structural systems, there are some limitations to provide adequate lateral stiffness, high ductility, and architectural openings simultaneously. Consequently, the concept of T-Resisting Frame (TRF) has been introduced to improve the performance of structures. In this study, Configuration of TRF is a Vertical I-shaped Plate Girder (V.P.G) which is placed in the middle of the span and connected to side columns by two Horizontal Plate Girders (H.P.Gs) at each story level. System performance is improved by utilizing rigid connections in link beams (H.P.Gs). Plastic deformation leads to tension field action in H.P.Gs and causes energy dissipation in TRF; therefore, V.P.G. High plastic deformation in web of TRF's members affects the ductility of system. Moreover, in order to prevent shear buckling in web of TRF's members and improve overall performance of the system, appropriate criteria for placement of web stiffeners are presented in this study. In addition, an experimental study is conducted by applying cyclic loading and using finite element models. As a result, hysteresis curves indicate adequate lateral stiffness, stable hysteretic behavior, and high ductility factor of 6.73.

Improvement of Rheological and Functional Properties of Salmon FPC by Enzymatic Partial Hydrolysis 2. Rheological and functional properties of salmon FPC hydrolysates

  • LEE Jong-Ho;LEE Keun-Tai;PARK Seong-Min;PARK Chan-kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.6
    • /
    • pp.956-963
    • /
    • 1997
  • To enhance application of FPC in food industry, salmon FPC hydrolysates were produced and their functional properties were investigated. Hydrolysates of salmon FPC showed high solubilities ranged from approximately $80\~95\%$. Emulsifying activity index (EAI) values of hydrolysates were higher than that of egg white, however sugar ester showed the highest EAI value of 32.5. Though sugar ester had the best emulsifying stability value $({\Delta}EAI)$ of 9.65, hydrolysates showed better ${\Delta}EAI$ value than that of egg white. Foam Activity of hydrolysates was predominantly better than those of controls and also foam stability value showed similiar trend. Osmolality of hydrolysates was increased with the increase of degree of hydrolysis (DH) and concentration of protein, but it showed very lower osmolality than that of NaCl. Flow property of hydrolysates showed different upward-downward curves, and hysteresis loop increased with the increase of DH. ACE inhibitory activity showed similiar value ranged from $21.1\~24\%$ at all DH values.

  • PDF

Ferroelectric Properties of PZT Thin Films by RF-Magnetron sputtering (RF 마그네트론 스퍼터링 법을 이용한 PZT 박막의 강유전 특성)

  • Park, Young;Joo, Pil-Yeoun;Yi, Ju-Sin;Song, Jun-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.341-344
    • /
    • 1999
  • The effects of post annealing treatments of ferroelectrlclty in PZT(P $b_{1.05}$(Z $r_{0.52}$, $Ti_{0.48}$) $O_3$ thin film deposited on Pt/ $SiO_2$/Si substrate by RF-Magnetron sputtering methode was Investigated. Analyses by RTA(Rapid Thermal Annealing) treatments reveled that the crystallization process strongly depend on the healing temperature. The Perovskite structure with strong PZT (101) plan was obtained by RTA treatments at 75$0^{\circ}C$ With increasing RTA temperature of PZI thin films, the coercive field and remanent Polarization decreased, while saturation polarization( $P_{r}$) was decreased. P-E curves of Pt/PZT/Pt capacitor structures demonstrate typical hysteresiss loops. The measure values of $P_{r}$,. $E_{c}$ and dielectric constants by post annealed at 75$0^{\circ}C$ were 38 $\mu$C/$\textrm{cm}^2$ 35KV/cm and 974, respectively. Switching polarization versus fatigue characteristic showed 12% degradation up to 10$^{7}$ cycles.s.s.s.s.s.s.

  • PDF

Enhancing seismic performance of ductile moment frames with delayed wire-rope bracing using middle steel plate

  • Ghalandari, Akram;Ghasemi, Mohammad Reza;Dizangian, Babak
    • Steel and Composite Structures
    • /
    • v.28 no.2
    • /
    • pp.139-147
    • /
    • 2018
  • Moment frames have considerable ductility against cyclic lateral loads and displacements; however, sometimes this feature causes the relative displacement to exceed the permissible limits. This issue can bring unfavorable hysteretic behavior on the frame due to the reduction in the stiffness and resistance against lateral loads. Most of common bracing systems usually control lateral displacements through increasing stiffness while result in decreasing the capacity for energy absorption. This has direct effect on hysteresis curves of moment frames. Therefore, a system that is capable of both having the capacity of energy absorption as well as controlling the displacements without a considerable increase in the stiffness is quite important. This paper investigates retrofitting of a single-storey steel moment frame using a delayed wire-rope bracing system equipped with the ductile middle steel plate. The steel plate is considered at the middle intersection of wire ropes, where it causes cables to be continuously in tension. This integrated system has the advantage of reducing considerable stiffness of the frame compared to cross bracing systems as a result of which it could also preserve the frame's energy absorption capacity. In this paper, FEM models of a delayed wire-rope bracing system equipped by steel plates with different geometries have been studied, validated, and compared with other researchers' laboratory test results.

Seismic upgrading of reinforced concrete frames with steel plate shear walls

  • Korkmaz, Hasan H.;Ecemis, Ali S.
    • Earthquakes and Structures
    • /
    • v.13 no.5
    • /
    • pp.473-484
    • /
    • 2017
  • The objective of this paper is to report on a study of the use of unstiffened thin steel plate shear walls (SPSWs) for the seismic performance improvement of reinforced concrete frames with deficient lateral rigidity. The behaviour of reinforced concrete frames during seismic activities was rehabilitated with an alternative and occupant-friendly retrofitting scheme. The study involved tests of eight 1/3 scale, one bay, two storey test specimens under cyclic quasi-static lateral loadings. The first specimen, tested in previous test program, was a reference specimen, and in seven other specimens, steel infill plates were used to replace the conventional infill brick or the concrete panels. The identification of the load-deformation characteristics, the determination of the level of improvement in the overall strength, and the elastic post-buckling stiffness were the main issues investigated during the quasi-static test program. With the introduction of the SPSWs, it was observed that the strength, stiffness and energy absorption capacities were significantly improved. It was also observed that the experimental hysteresis curves were stable, and the composite systems showed excellent energy dissipation capacities due to the formation of a diagonal tension field action along with a diagonal compression buckling of the infill plates.

Magnetizing Analysis of a Convergence Purity Magnet using Preisach model and Finite Element Method (프라이자흐 모델과 유한요소법을 이용한 C.P.M의 착자 특성 해석)

  • Yoon, Tae-Ho;Kwon, Byung-Il;Park, Seung-Chan;Woo, Kyung-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.11
    • /
    • pp.729-736
    • /
    • 2000
  • This paper deals with the characteristic analysis of magnetizer for convergence purity magnet by the finite element method. The analysis utilizes combined method of the time-stepped finite element analysis and the Preisach model with hysteresis phenomena. In the finite element analysis, the non-linearity and the eddy current of the magnetizing fixure and permanent-magnet are taken account. The magnetization distribution in the permanent magnet is determined by using Preisach model which are composed of Everett function table and the first order transition curves is obtained by the Vibrating Sample Magnetometer. The calculated flux density values on the surface of the permanent magnet are led to the approximated gauss density values measured by the gauss meter. As a result, winding current, copper loss, eddy current loss of the magnetizing yoke, flux plot, surface gauss plot, temperature rise of the coil and resistor variation, vector diagram of magnetization distribution are shown.

  • PDF