• Title/Summary/Keyword: hygiene management standard

Search Result 154, Processing Time 0.026 seconds

Evaluation of the Input Status of Exposure-related Information of Working Environment Monitoring Database and Special Health Examination Database for the Construction of a National Exposure Surveillance System (국가노출감시체계 구축을 위한 작업환경측정과 특수건강진단 자료의 노출 정보 입력 실태 평가)

  • Choi, Sangjun;Koh, Dong-Hee;Park, Ju-Hyun;Park, Donguk;Kim, Hwan-Cheol;Lim, Dae Sung;Sung, Yeji;Ko, Kyoung Yoon;Lim, Ji Seon;Seo, Hoekyeong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.3
    • /
    • pp.231-241
    • /
    • 2022
  • Objectives: The purpose of this study is to evaluate the input status of exposure-related information in the working environment monitoring database (WEMD) and special health examination database (SHED) for the construction of a national exposure surveillance system. Methods: The industrial and process code input status of WEMD and SHED for 21 carcinogens from 2014 to 2016 was compared. Data from workers who performed both work environment monitoring and special health examinations in 2019 and 2020 were extracted and the actual status of input of industrial and process codes was analyzed. We also investigated the cause of input errors through a focus group interview with 12 data input specialists. Results: As a result of analyzing WMED and SHED for 21 carcinogens, the five-digit industrial code matching rate was low at 53.5% and the process code matching rate was 19% or less. Among the data that simultaneously conducted work environment monitoring and special health examination in 2019 and 2020, the process code matching rate was very low at 18.1% and 5.2%, respectively. The main causes of exposure-related data input errors were the difference between the WEMD and SHED process code input systems from 2020, the number of standard process and job codes being too large, and the inefficiency of the standard code search system. Conclusions: In order to use WEMD and SHED as a national surveillance system, it is necessary to simplify the number of standard code input codes and improve the search system efficiency.

The Factor Analysis of Airborn Fiber Concentrations at Parking Lots in Seoul (서울 시내 일부 주차장의 공기중 섬유농도에 영향을 미치는 인자 분석)

  • Moon, Ji Young;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.157-167
    • /
    • 1994
  • This study was conducted to analyze the relationship between the types of fiber and its content and the levels of airborne fiber concentrations at eight parking lots where sprayed insulation material was found on the walls and ceilings. Also this study was designed to find the relationship between the levels of airborne fiber concentrations and such variables as air current, humidity, total exhaust volume, surface condition of insulation material and building age. The results obtained were as follows : 1. No significant correlation was found between the levels of airborne tiber concentration and the building age, air current, humidity, total exhaust volume, space and the number of traffics. 2. A significant correlation was found between the levels of airborne fiber concentration and the MMMF content of the insulation material(r=0.7594). However, no significant correlation was found between the levels of airborne fiber concentration and total fiber content of insulation material. 3. The differences of the airborne fiber concentrations among Cateogory 1, 2 and 3 classified by the degrees of surface insulation material maintenance were very significant. 4. Two bulk samples contained 30% crodicolite and 1% anthophylite. The MMMFs, in all parking lots, included mineral wool, cellulose fiber, trace cellulose fiber, trace tiber glass and vermiculite. 5. The mean value and the range of airborne fiber concentrations at 8 parking lots were $0.0239{\pm}0.0095f/cc$ and 0.0054-0.0447 f/cc, respectively. The fiber concentrations of 35 out of 38 samples(92%) were over 0.01 f/cc which is the Environment Administration's recommended asbestos level for the underground space. This study suggests that most of building insulation materials used in Korea, contain MMMF and sometimes asbestos. Currently, MMMF pollution levels may exceed the Environment Administration's recommended level for underground space. It has been found that airborne fiber concentrations increased significantly with MMMF content and with the maintenance condition of surface material. Therefore, it is recommended that a proper management technique should be developed and immediately implemented since the conditions of surface material will be gradually deteriorated due to building age and usage. Since health hazards of the MMMF, similar to those of asbestos, are being gradually acknowledged, a proper management technique which is applicable to control total airborne fiber concentrations, both asbestos and MMMF, be developed and an acceptable indoor air standard be promulgated as early as possible.

  • PDF

A study on the criteria and supply status of information for managing carcinogens in domestic and foreign (국내외 발암성물질의 관리기준과 정보제공 현황에 관한 연구)

  • Lee, Kwon Seob;Lee, Jong Han;Lee, Hye Jin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.1
    • /
    • pp.40-48
    • /
    • 2011
  • This study was intended to resolve problems caused by different classification criteria and management methods of carcinogenicity, which have made industrial safety & health institutions and business employers difficult to execute projects or to carry out occupational safety and health related works, and have affected how civic groups perceive carcinogens. The content of this study contained the comparison of management and categorization standards for carcinogens between Korea and other countries as well as the current carcinogenicity-related information supply status of each professional institution. Furthermore, this research examined the current state of supplying information on carcinogenicity among major institutional information supply according to the categorization standard for carcinogens by UN GHS, Ministry of Employment and Labor in Korea(KMoEL), and GHS MSDS provided by Korea Occupational Safety & Health Agency(KOSHA). Now, professional agency provide 927 kinds of IARC, 237 kinds of NTP, 351 kinds of ACGIH and 1,006 kinds of EU ECHA information on carcinogenic agents. KMoEL provides carcinogenicity-related information of 58 chemical agents in accordance with the category of carcinogens guided by ACGIH. KOSHA offers 13,232 kinds of GHS MSDS information including 2,484 carcinogenic substances. Therefore, carcinogenicity-related information of chemical substances, which are not available on the existing GHS MSDS DB, should be updated for the future reference.

A Study on the Management & Utilization of School Drinking Water (학교음용수 관리 및 이용실태)

  • Hong, Jung-Ha;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.2
    • /
    • pp.87-104
    • /
    • 2000
  • The purpose of this study was to obtain the basic data as a improvement method through the fact-revealing concerning the drinking water management of school and utilization of student. The problems of the research are as follows: First, to investigate status of management of drinking water by area and school. Second, to investigate student's utilization of drinking water by area and school. 1,400 students was selected at 45 elementary and middle-high schools located in Kang-won province, and this study was constituted of two questionnaires(for school's questionnaire and student's questionnaire). The results was analyse through the frequency analysis, $x^2$-test on the basis of the above research problem by SPSS program. The findings of this research are as follows; 1) The Management of School Drinking Water First, the source of school drinking water was mostly piped water. Inspection of water quality has been fulfilled under four times a year, in the other hands, from the result inspection, the schools which was given inadequate determination was 22.2%. Second, reservoir cleaning and hygiene inspection failed far short of the regulations. Especially, reservoir cleaning was managed by exterior consignment industry not low-level officials. Third, school water drinking was the most supplied through the type of water purifier. Water purifier has been distributed to city-located and middle-high school highly, factually the water from water purifier was served with water cup. Fourth, the selection standard of water drinking manager showed slightly differently by school, accordingly there need to develope integrated system with the respective to its effective systematic management. Fifth, water cup was mostly treated by only water clear, which is to vindicate the problems concerning hygiene management. 2) Utilization of school student on Drinking Water First, Disbelief on drinking water of school student was very high. Especially, proportion of middle-high school student's disbelief of drinking water was higher than elementary school student, also girls higher than boys. Many of student have heard to don't drink water from around people. And there were showed meaningful differences by area and school. Second, It was showed many student recognize had to utilize water purifier, boiled water. However, they have still drunken the tap water or portable water from their home. Third, Many of student showed negative response with the respective to the management conditions of drinking water in classroom, There were showed meaningful differences by area and school. From the fact-revealing of water cup management, Students mostly answered to 'only water clear' and the answer of 'None use' or 'With personal cup' was higher. Fourth, In bad experience of Drinking Water, student mostly answered to 'occasionally' and there were showed meaningful differences by school. student's disease experience with school drinking water was few and there were showed meaningful differences by area and gender.

  • PDF

Performance of elderly oral health management and related factors among care workers in long-term-care hospitals (요양병원 요양보호사의 노인 구강건강관리 수행도 관련요인)

  • Choi, Se-Eun;Han, Mi-Ah;Park, Jong;Ryu, So-Yeon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.5
    • /
    • pp.791-803
    • /
    • 2017
  • Objectives: Oral health management is important to improve the quality of life among the elderly. This study investigated the performance of elderly oral health management among some care workers in long-term-care hospitals. Methods: The study subjects were 174 care workers in 10 long-term-care hospitals. Data on general characteristics of care workers, attitude, recognition and knowledge of elderly health, performance of elderly oral health management were collected by a self-administered questionnaire. Data were analyzed through descriptive analysis, t-test, ANOVA, correlation and multiple regression analysis by using a SPSS version 23.0 statistical program. Results: The performance score of oral health management was $4.34{\pm}0.64$ on the 5-point Likert scale. The subjects who exercised more than 2 times a month were significantly higher in their performance of elderly oral health management compared to subjects who did not exercise (${\beta}=0.232$, p=0.035). And, the subjects who cared 10-19 persons were significantly higher in performance of elderly oral health management compared to subjects who cared more than 20 elderly (${\beta}=0.246$, p=0.020). The oral health behavior of care worker (${\beta}=0.271$, p<0.001) and the knowledge of oral health care (${\beta}=0.055$, p=0.008) were positively related to the performance of elderly oral health management. Conclusions: The educational program designed to improve knowledge of care workers in accordance with the standard textbook for training care workers should be developed, and the long term education program should be reinforced to improve the performance for elderly oral health care. If care workers can care a proper number of old persons, they will give oral health care to them.

Pretreatment method of urinary thiodiglycolic acid as metabolite of vinyl chloride (염화비닐의 요중 대사물질인 thiodiglycolic acid의 분석을 위한 전처리 조건)

  • Hong, Joo Youn;Kim, Chi Nyon;Jung, Jae Hoon;Chang, Jung Hwan;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.23-40
    • /
    • 1999
  • The analysis of thiodiglycolic acid in urine has been used as an index of biological exposure to vinyl chloride. Unfortunately thiodiglycolic acid has a strong hydrophilic character, because it has two carboxylic groups, so that it can only be extracted with organic solvent with a great difficulty. Underivatized thiodiglycolic acid tends to tail because of non-specific interaction with the inert support. Therefore, esterification is the obvious first choice for derivatization of thiodiglycolic acid, particularly for gas chromatography. In this study, the focus of interest is to compare two method of esterifications (methylation and silylation). Methylation is to make the methyl ester of thiodiglycolic acid by reaction with diazomethane. Silylation is to make the trimethylsilyl ester of thiodiglycolic acid by reaction with N-trimethylsily-ldiethylamine. The results and conclusions are as the following: 1. The detection limit (sensitivity) of methylated thiodiglycolic acid was $5.00{\mu}g/m{\ell}$ and silylated thiodiglycolic acid was $3.07{\mu}g/m{\ell}$ by gas chromatography with flame ionization detector. 2. The optimal liquid-liquid extraction of thiodiglycolic acid was as following: To each of the tubes, $15m{\ell}$ of urine, concentrated sulfuric acid (pH 1 - 2) and 5 gsodium sulfate were added. The samples was extracted three times with $5m{\ell}$ ethylacetate each time. 3. The methylated thiodiglycolic acid was more stable than silylated thiodiglycolic acid in extractional solvent which contained humidity. 4. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.07324 in methylated thiodiglycolic acid with external standard calibration, and 0.07033 in methylated thiodiglycolic acid with internal standard calibration. 5. The precision (pooled coefficient of variation for 4 days) of the analysis was 0.10914 in silylated thiodiglycolic acid with external standard calibration, and 0.13602 in silylated thiodiglycolic acid with internal standard calibration. From the above results, the analysis of methylated thiodiglycolic acid was more sensitive (limit of detection) than silylated thiodiglycolic acid by gas chromatography. However, the methylated thiodiglycolic acid was stable in the humidity and was separated sharply on chromatogram. Also, analysis of methylated thiodiglycolic acid was more precise (pooled coefficient of variation for 4 days) than silylated thiodiglycolic acid. In conclusion, it is established that the analysis of methylated thiodiglycolic acid is appropriate for biological monitoring of exposure to vinyl chloride.

  • PDF

Improvement of Analysis Methods for Fatty Acids in Infant Formula by Gas Chromatography Flame-Ionization Detector (GC-FID를 이용한 조제유류 중 지방산 분석법 개선 연구)

  • Hwang, Keum Hee;Choi, Won Hee;Hu, Soo Jung;Lee, Hye young;Hwang, Kyung Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • The purpose of this research is to improve analysis methods of determining the contents of fatty acids in infant formulas and follow-up formulas. A gas chromatography (GC) method was performed on a GC system coupled to flame ionization detector, with a fused silica capillary column (SP2560, 100 m×0.25 mm, 0.20 ㎛). The method was validated using standard reference material (SRM, NIST 1849a). Performance parameters for method validation such as specificity, linearity, limits of detection (LOD) and quantification (LOQ), accuracy and precision were examined. The linearity of standard solution with correlation coefficient was higher than 0.999 in the range of 0.1-5 mg/mL. The LOD and LOQ were 0.01-0.06 mg/mL and 0.03-0.2 mg/mL, respectively. The recovery using standard reference material was confirmed and the precision was found to be between 0.8% and 2.9% relative standard deviation (RSD). Optimized methods were applied in sample analysis to verify the reliability. All the tested products had acceptable contents of fatty acids compared with component specification for nutrition labeling. The result of this research will provide efficient experimental information and strengthen the management of nutrients in infant formula and follow-up formula.

The Classification of Standard Nursing Activities in Korea (한국 표준 간호행위 분류)

  • 박정호;성영희;송미숙;조정숙;심원희
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.6
    • /
    • pp.1411-1426
    • /
    • 2000
  • A nursing activity classification for hospitalized patients was performed based on an article review regarding nursing definition and nursing activity classification system. The study was conducted as follows: 1) Taxonomy was developed by the research team through the Delphi process and review article. The taxonomy consists of four nursing processes, (assessment, diagnosis, intervention and evaluation) and twelve nursing activity domains space (resperation, nutrition, elimination, exercise/alignment maintenance, comfort, hygiene, safety, spiritual support, counseling/ education, medication, communication, patient and information management). 2) First, nursing activities of the intervention process were listed and then classified by the nursing process of assessment, diagnosis, intervention and evaluation. The list consists of twelve nursing activity domains and 136 nursing activities. 3) A pilot study was conducted in two hospitals to verify validity and appropriateness of nursing activities. 4) The content validity index, which was calculated by 6 clinical practice experts, was 0.95. Also, a nursing activity classification system should also be developed in the department of community nursing and home health care nursing.

  • PDF

Simultaneous Analysis and Survey for Contamination of Nivalenol, Deoxynivalenol, T-2 toxin and Zearalenone in Feed (사료 중 Nivalenol, Deoxynivalenol, T-2 foxin과 Zearalenone의 동시분석과 오염도조사)

  • Kim, Dong-Ho;Kim, Hyun-Jung;Jang, Han-Sub;Kim, Yeong-Min;Choi, Heng-Bo;Ahn, Jong-Sung
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • Nivalenol (NIV), deoxynivalenol (DON), T-2 toxin (T-2) and zearalenone (ZEN) are mycotoxins produced by some Fusarium species known to be very frequently contaminated in feed. The study for simultaneous analysis and contamination survey in animal feed carried out. All mycotoxins were analysed by using high performance liquid chromatography tandem mass with internal standard. The limits of detection (LOD) were $2.0\;{\mu}g/kg$, $1.0\;{\mu}g/kg$, $1.0\;{\mu}g/kg$ and $0.1\;{\mu}g/kg$ for NIV, DON, T-2 and ZEN, respectively. Two hundred and thirty nine samples of feed were collected. The average concentration of DON was $212.3\;{\mu}g/kg$, $207.8\;{\mu}g/kg$ and $812.1\;{\mu}g/kg$ in chicken, pig and cattle feed, respectively. The average concentration of ZEN was $31.2\;{\mu}g/kg$, $35.6\;{\mu}g/kg$ and $147.2\;{\mu}g/kg$ for them, respectively. Especially, the levels of contamination for DON and ZEN were higher than those of NIV or T-2. And, the levels of contamination for four Fusarium mycotoxins in cattle feed appeared higher than those of pig and chicken feed. It was investigated that the high level of mycotoxin contamination in cattle feed was caused by com gluten feed of ingredients for feed, mainly.

Comparative Study of ISO Standards for an Effective Implementation of the Domestic Medical Device GMP System (ISO 국제표준의 비교 연구를 통한 국내 의료기기 GMP 제도의 효과적인 운영 방안)

  • Jung, Young A;Kim, Young Jin
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.2
    • /
    • pp.211-224
    • /
    • 2018
  • Purpose: It can easily be understood that more rules and regulations need to be imposed on the medical device industry due to its impact on public health and hygiene. Domestic medical device manufacturers are thus required to comply with the requirements specified in the good manufacturing practice (GMP) system, and it is essential to abide by the international standards as well to sustain their global competitiveness. The main purpose of this study is to review the guidelines of the medical device GMP system in Korea and propose future directions for further enhancement of the GMP system. Methods: Specific requirements prescribed in international standards, such as ISO 9001:2015, ISO 13485:2016, ISO 14971:2012, and ISO 14155:2011, are analyzed and compared with the domestic GMP system. Results: It has been observed that the generic international standard related to quality management system, ISO 9001:2015, lays out the foundations for the development of quality management system relevant to medical device industry, ISO 13485:2003, with which the domestic GMP system is fully compatible. Further, several important aspects of risk management and clinical trials of medical devices are also recognized and included in the domestic medical device GMP system. Conclusion: Even though specific requirements of individual ISO standards are slightly different from each other, their overall structure and framework may contribute to the development and enhancement of globally competitive GMP system of the domestic medical device industry.